SPECIFICATIONS SPECIFIC

INTERIM SECTION x.xxx

JARING WIRE (WIRE MESH)


AND
JARING CABLE (CABLE NET)
SAFETY AS A ROCK SLOPE

SKh-1.3.14.1 GENERAL
1. Overview

a) This specification covers for handling jobs falling rocks and debris with
active and passive methods.

b) Handling of debris falling rock and debris material with a passive method
can be done by installing wire mesh (wire mesh) or cable net (net cable)
that serves to cover the surface of the slope, so the rocks will fall
redirected to the bin at the foot of the slopes.

c) Handling of debris falling rock and debris material with an active method
can be done by installing a steel wire mesh (wire mesh) or cable net (net
cable) with reinforcement anchors diameter and a certain distance.

d) This work includes the preparation, supply and installation of steel wire
mesh (wire mesh) or cable net (net cable) and anchors.

e) Net steel wire (wire mesh) or cable net (net cable) must diangkurkan on the
upper slopes positions with various cable anchors alternating (wire rope
anchor). The length of this anchor is inserted as shown by drawing a plan
or determined byDirWork reflection, This could be a kind of anchor
material alternating cable (wire rope) or in the form of steel bars (bar
anchor) are in grouting.

f) Ja ring steel wire (wire mesh) or cable net (net cable) should be coated
with galvanized (zn); galvan (zn-al); aluminum (Al) or PVC.

g) Installation of wire mesh (wire mesh) or net cable (cable net) already
includes the necessary accessories and are not limited to the plate anchor
(anchor plate), a seam (clamp), clamp (clip), the cable cross (wire rope),
bolts (nuts), hog rings, as well as other accessories recommended by the
manufacturer).

h) Angkur form alternating cable (wire rope anchor) at the top which serves as
a barrier steel wire as well as the strengthening of the slopes are paid
separately from the installation work steel wire.

SKH-1.3.14 -1
2. Work-Related Other Sexy Sexy This

a) Management and Traffic Safety: Seksi 1.8


b) Kajian Technical Field: Seksi 1.9
c) Keselamatan and Health: Seksi 1:19
d) GAlian: Seksi 3.1

3. Reference Standard

american Society for Testing and Materials (USTM)

ASTM A-36: Standard specification for carbon steel structural


ASTMA 153-80: Standard Specification for Zinc Coating (hot-Dip) on
Iron and Steel Hardware.
ASTMA 615: Standard Specification for Deformed and
Plain Carbon-Steel Bars for Concrete
Reinforcement.
ASTMA 722: Standard Specification for Uncoated High Strength Steel
Bars for Prestressing Concrete.
ASTM A-975 97: Standard Specification for Double-Twisted
Hexagonal Revet Mesh Gabions and
Mattresses (Metallic-Coated Steel Wire or
Metallic-Coated Steel Wire With Poly (Vinyl
Chloride) (PVC) Coating).
ASTM A-641: Standard Specification for Zinc-Coated
(Galvanized) Carbon Steel Wire.
ASTMA 90 / A 90M: Test Method for Weight [Mass] of Coating on Iron
and Steel Articles with Zinc or Zinc-Alloy
Coatings.
ASTMA 325: Standard Specification for structural bolts, steel, heat
treated, 120/105 ksi minimum tensile strength.
Brirish Standard (BS-EN)

BS-EN-10223-3: Steel wire and wire products for fencing and netting.
Hexagonal Wire Mesh steel products for civil
engineering purposes.
BS-EN-10244-2: Steel wire and wire products - Non-ferrous metallic
coatings on steel wire.
BS-EN-10218-2: Steel wire and wire products. General. wire
dimensions and tolerances.
BS-8006-2: Code of practice for strengthened reinforced soils and
other fills, part 2: soil nail design.

SKH-1.3.14 -2
StNational andard Indoneisa (SNI)

SNI 2049-2015: Portland Cement


SNI 03-1968- : Metode sieve analysis testing fine and coarse
1990 aggregates

StReference andar Lainya

Tennessee

Tennessee SP707D: Special provision regarding slope rockfall drape.


Tennessee SP707E: Special provision regarding pinned slope rockfall
mesh.

4. Terms and Definitions

Untuk intended use of these guidelines, the following terms and definitions
used.

a) Net wire (wire mesh)

Susunan wire mesh made of a single steel wire with a certain diameter,
wire mesh has different forms depending on the strength of this wire
netting system.

b) Net cable (cable net)

Susunan cable nets made of woven wire that set up a certain diameter
steel cable, wire nets have various forms depending on the strength of this
wire netting system.

c) Angkur (wire rope anchor)

Angkur commonly used in the installation of steel wire


(wire mesh) Is the anchor in accordance with ASTM A325.

d) Material cement injection (grouting)

SEmen or a mixture of cement and sand to fill the anchor hole. Grouting
can also be added with aditife material approved by the Engineer.

5. Submission Work Readiness

SBefore the procurement of materials and begin the work, the Service
Provider shall submit the following information:

a) Certificate of Factory that includes the name of the manufacturer, product


name, product type number, nature - the nature of the steel wire.
b) Layout of the proposed steel wire including grafting techniques in the
field and its implementation details.
SKH-1.3.14 -3
SKh-1.3.14.2 MATERIAL

1. The steel wire nets

Wire mesh used in this specification is divided into four types:


a. Standard wire mesh (wire mesh);
b. Wire mesh with high strength (High Tensile);
c. Nets standard cable (cable net);
i, Cable nets standard for passive method
ii,Standard cable nets for the active method
d. High strength cable nets (High Strength cable net).

1.1 Standard Wire Mesh (wire mesh)

Standard wire netting should digalvanisir, can be a hexagonal shaped


ridden twice; nominal diameter of not less than 3 mm. Wire netting is
made of a soft tempered steel wire with a maximum tensile strength
517.11 MPa (equivalent to 75,000 psi) in accordance with ASTM A 975-
11. The maximum size of the largest opening dimension of 114 mm.
The minimum tensile strength steel nets 51.1 kN / m (equivalent to
3.500 lb / ft) that wrap in parallel.

1.2 Nets Wire with High Strength (High Tensile)

Besides shaped wire mesh and twist hexagonal twice used for high
tensile strength wire mesh. Material wire should be coated with a
metallic layer (zinc, galvan or aluminum) or layers of PVC or stainless
steel material (stainless steel) with a nominal diameter of not less than
3.0 mm. The maximum size of the largest opening dimension of 114
mm. Nets must have a minimum tensile strength of longitudinal or load
capacity of 145.94 kN / m (equivalent to 10,000 lbs / ft).

Steel wire with high strength must have a carrying capacity of the
skewer (bearing Resistance to puncturing) and the carrying capacity of
the shearing-off according to the planners. Splicing between panels of
woven wire mesh with the system (seaming) must wear a wire rope
with a minimum diameter of 8 mm (equivalent to 5/16 inch).

SKH-1.3.14 -4
1.3 Net Cabling Standard (cable net)

1.3.1 standard cable nets for passive method


Cable nets consist of the form of square panels, rectangular or
any other form that is connected to the limit so as to form a curtain
panel. Each panel of woven wire mesh incorporated in a uniform
grid with a square pattern, rectangular, omega or other forms,
openings no more than 60.96 cmkali 60.96 cm (equivalent to 24
inch time 24 inch) and wide openings no more than 3716.12 cm2
(equivalent to 576 inch2).

Sach cable that crosses perpendicular must be fastened securely


at an angle of approximately 90 °. The size of the steel woven wire
mesh that forms must have a minimum diameter of 8 mm (5/16
inch equivalent) and a minimum tensile strength minimum 40.92
kN (equivalent to 9,200 lbs). Woven wire mesh system must have
a minimum nominal tensile strength capacity of 116.753 kN / m
(equivalent to 8.000 lb / ft).

If the cable used nets have openings over 114 mm (4 inches),


then akan used steel wire mesh (wire mesh) applied to the cable
nets to prevent the escape of rocks larger than 114 mm. Annealing
wire meshas written Article 1.1 and 1.2, as written rekomendasi
manufacturer and approved by the Direkthe Works, The cost for
the steel wire is paid separately.

1.3.2 Net Cabling Standard for active methods

Cable nets consist of the form of square panels, rectangular or


any other form that is connected to the limit so as to form a curtain
panel. Each panel of woven wire mesh incorporated in a uniform
grid with square patterns, rectangular openings omega or other
forms of no more than 30.48 cmkali 30.48 cm (equivalent to 12
inch time 12 inch) and wide openings no more than 1858.06 cm2
(equivalent to 144 inch2). Each cable which crosses perpendicular
to be fastened securely at an angle of about 90o.

ukUran steel woven wire mesh that forms must have a minimum
diameter of 8 mm (5/16 inch equivalent) and a strong minimum
breaking up (breaking strength) 3792.12 MPa minimum (or
equivalent to 550,000 psi). Woven wire mesh system must have a
minimum nominal tensile strength capacity of 145.94 kN / m
(equivalent to 10,000 lb / ft).
If the cable used nets have openings over 114 mm (4 inches),
then akan used steel wire mesh (wire mesh) applied to the cable
nets to prevent the escape of rocks larger than 114 mm. Annealing
wire meshas written Article 1.1 and 1.2, as written rekomendasi
manufacturer and approved by the Direkthe Works, The cost for
the steel wire is paid separately.

Net 1.4 Cable with High Strength (High Strength cable net)

Cable nets with high power consists of a square panel shape,


rectangular, omega or other form that is connected to the limit so
as to form a curtain panel. Each panel of woven wire mesh
incorporated in a uniform grid with square patterns, rectangular
openings omega or other forms of no more than 30.48 cm
(equivalent to 12 inch). Woven wire mesh system must have a
minimum nominal tensile strength capacity of 218.91 kN / m
(equivalent to 15,000 lb / ft).

If the cable used nets have openings over 114 mm (4 inches),


then akan used steel wire mesh (wire mesh) applied to the cable
nets to prevent the escape of rocks larger than 114 mm. Annealing
wire meshas written Article 1.1 and 1.2, as written rekomendasi
manufacturer and approved by the Direkthe Works, The cost for
the steel wire is paid separately.

2 Angkur As Retaining Steel Wire Mesh

Bahan material used is new and unblemished. All defective materials must be
removed from the site without the added cost. The materials used in the work
anchors (wire rope anchor) include:

1) Anchor the form of alternating cable (wire rope anchor)

Angkur be alternately used to hang a steel wire or cable nets on


methods of active and passive methods. Cable anchors must be
possessed alternately as the minimum diameter
1.84 cm (¾ inch equivalent), with a minimum breaking strong
(breaking
strength) 235.40 kN (equivalent to 52 920 lbs). Anchors should be
folded and fastened each 0.60 m (equivalent to 2.0 ft) at the end of
the thimble given.

Angkur installed according to the plans or approval Direkthe


WorksBut spaced longitudinal direction of not more than 7.0 m
(equivalent to 23 ft). The minimum length of the pitch-grouting
(bonded length) Which is embedded is 3.0 m (equivalent to 10 ft).
Minimum drill hole of 6.35 cm (2.5 inch equivalent).

Penyedia services must make borlog in every hole drilled. Borlog


should include but not limited to; the location of the drill hole, the
hole diameter, hole length, angle from horizontal, the date / time of
drilling, a drill bit used, subsurface conditions encountered (the
groundwater table, stout, hollow, soil / rock weathered and others).
The service provider shall forthwith borlog on service users every
day.

2) Pin the form of steel bars (pinned anchor)

Pin the form of a threaded steel rod used to hold the rocks and wire
netting or mesh cable and is only used for the active method. Pins
are used in the form of a screw reinforcement or prestressing steel.
Threaded steel rods or prestressing steel rods must be continuous
without joints or welding, a new, straight, not broken, as shown in
the picture plan.

Bwrote reinforcing thread used from grade 75 steel with a minimum


tensile strength of 520 MPa in accordance with the ASTM A-615.
Prestressing steel used steel grade 150 with a minimum tensile
strength of 1,035 MPa in accordance with the ASTM A-722.

3) centralizers

Untuk put the wires cross in the middle of the centralizer installed
with a minimum distance of 0.60 m (equivalent to 2.0 ft).
Centralizer is made of PVC material in the fabrication or other
synthetic materials. Centralizer fitted on anchors allowing the
anchor rod in the middle of the drill holes with a maximum deviation
of 25 mm. Centralizer should be selected and installed such that
the stem tremie can sign up to bottom of the hole so that the grout
material fills the entire hole to the top.

3 Material Grouting

Material grouting is used to fill the gap created in the anchor holes and also to
fill in the gaps of rock fractures.

1) Grout
SEmen or a mixture of cement and sand at age 28 day
compressive strength of 21 MPa with cement water factor of 0.4 to
0.5.
2) chemical mixture used to control bleed on concrete, improve
flowability, reduce the water content extends the time set concrete.
Accelerator is not allowed to be used. Admixture should match the
grout material and mixed in accordance with the requirements of
the manufacturer (manufacturer).

3) Cement
Sesuai provision 2049 2015 SNI using cement type I, II or III
depending on the plan or determined by DirWork reflection, Semen
is stored so as not to hydration parsialatau humidity. The cement
has hardened or membongkah not be used. Aggregates are stored
separately in order agaregat not mixed with other materials.

4) Aggregate Fine
SSNI 03-1968-1990 esuai information regarding sieve analysis
testing method fine and coarse aggregates

SKh-1.3.14.3 EXECUTION

1. Preparation

a) Preparation of Material and Equipment

i, Bahan-steel wire netting material (wire mesh) for handling the


fallen rocks as indicated in the corresponding design drawings and
manufacturer's recommendations which meets the requirements
provided in the field.

ii, Peralatan required for the installation of anchors (wire rope anchor)
and steel wire (wire mesh) were prepared and examined in good
condition.

iii.Finger ng steel wire, steel woven wire mesh, anchor, alternating


cables anchoring wire mesh, wire ties, and galvanized steel ring
should be marked with numbered and labeled for identification
purposes before being transported to the workplace.

iv, Verify the location of the installation of wire mesh and location of each
anchor.

b) Preparation of the condition of the slopes

i, Pembersihan rock block potentially damaging nets or other parts


must be done before the installation of steel wire.
ii, Pembersihan by mechanical means can be performed using
excavators. To dispose of a very large stone can use a hydraulic
breaker tool that is inserted into the crevices of the rock open.
Pelandaian rock slope can be done manually or by means of
excavator adapted to the situation on the ground.

2. Installation of anchors

Tahapan installation of anchors in order are as follows:

i, Determination of the borehole

The location of the drill holes will be installed anchors adjusted by


drawing the plan and has been approved DireWork ksi,

ii, Drilling

Drilling holes have to be made at predetermined locations with


slope and depth as illustrated planner and has been approved
Direkthe Works, Determine drilling equipment and methods most
suited to the field conditions as shown in the picture plan. At the
time of drilling mud such as bentonite fluid usage is not allowed, if
the borehole wall landslides should be used casing.

Pemboran used is dry drilling (coring cleaning). Once drilling is


completed the drill holes are cleaned of all dirt before the anchor is
inserted. The finished hole should not be allowed more than three
hours. If the drilling is done on an existing slope / have been
extracted, it is necessary to use a strong scaffolding to stand
drilling machines as well as security and safety of the drilling team.

Numa need even need to drill machine tied with a rope connected
to the peg yan is in a position on the tool. Immediately doing the
temporary suspension and modification of drilling if found the
existence of early land subsidence. If there is damage on a slope
with the retrofitting of already installed, or on other structures, done
immediately attempt to re-stabilize and repair without added cost.

iii, PInstallation alternating cable (wire rope) or steel bars (bar anchor)
as anchors (wire rope anchor) at the position and depth as written
design.
Sfter drilling is completed, prior to the installation of anchors, drill
holes are cleaned of debris that are in the rest of drilling borehole
drilling depth check at the same time. Furthermore anchors placed
in the middle hole with the help of centralizers such that the
anchors are not warped and does not interfere with the grout hose
reaches the bottom of the hole, so that concrete can flow properly
to the top. Centralizers placed within 0.60 m from the bottom and
top of the hole. Rod position can be shifted with a tolerance of 25
mm from the center of the hole. Not allowed to suppress the
anchor when experienced difficulties at the time of entering into the
wellbore.

iv, Tolerance anchor placement


Deviasi allowed is 200 mm in all directions. The slope of the
anchor, the allowable deviation of + or - 3 degrees. Tolerance is
only valid for each anchor and does not apply cumulatively in the
entire area or a specific area.

Angkur who do not qualify deviation caused by the installation


method used by the Service Provider, to be replaced without the
added cost. The hole that is left over 3
Hours must be closed again (backfill) using tremie which reached
the bottom of the hole without the added cost. Drilling experiencing
unexpected difficultieswill transferred with the written consent
DirWork reflection, Displacement and closing back (backfill) on a
long hole counted as added work approved byDirekthe Works,

3. Grouting with concrete mix that meets the requirements to the full.

a) Mix Design Materials Grout

Gunakan cement or cement and sand mix as a grout material. Mix design
for grout material should be proposed in advance to be evaluated and
approved. Mix design should include results, compressive strength testing
showed that the proposed mix has a compressive strength of 28 days at
least 21 MPa with cement water factor of 0.4 to 0.5.

b) Grouting Equipment

Peralatan grout should produce a uniform grout mixture, do not


agglomerate, and can be stirred continuously. The pump used must be
equipped with a pressure gauge desired grout. Grout material can be
pumped into the drill hole after 60 minutes of mixing or in time
admixture recommended by the manufacturer. Grout that is inserted into
the drill hole does not match the required time will be rejected.

c) Methods of Grouting

grout ke boreholes conducted after the anchor is installed properly in every


hole and will be in the grout within a maximum of 3 hours after the hole is
completed. Enter the grout material began to bottom of the hole by using a
hose or pipe. The end of the hose or pipe must be maintained its position
is in the grout material while being pulled, to prevent pores.

Sach hole must be filled with grout material in one implementation, the
connection is not allowed. Grouting before inserted steel rods can be done
when after the unfilled hole grout, steel rods can be inserted easily. When
used casing, when the casing is revoked, the height of the grout in the
hole should be kept, in order to offset the pressures of groundwater or the
possibility of the collapse of the borehole wall.

Keep records of pressure grouting the anchors attached using pressure


grouting technique. Perform pressure setting grout to avoid excessive
damage to soil structure on the land or causing fractures.

4. Penghamparan

a) Net woven steel wire and steel wire seam with steel cinchn alternately such
that the cable entry through the individual cells in a part of woven wire
mesh in accordance with the design drawings.

b) Then they are tied together by wire ties.

c) Cable alternating horizontal rock anchoring nets tied to the top of the steel
woven wire mesh.

d) galvanized steel rings welded at the meeting alternating anchoring cables


and cable nets alternating horizontal rock retaining net vertical rock.

e) steel woven wire nets were hauled up the slope by using a crane.

f)Finger ng steel woven wire placed in such a way that covered the slopes
handled.

g) Cable alternating vertical rock anchoring nets attached to the anchor.


Kencangkan any alternate cable tie clip anchoring steel woven wire mesh.
h) Before and after installation, steel woven wire mesh should be checked to
make sure no damage (eg torn, broken or terkelupas).

i) J ika Direkthe Works menemukan steel woven wire mesh that is broken then
the Service Provider must immediately replace it.

5. Splicing

a) The Service Provider shall provide an explanation regarding the procedures


for grafting (overlap). The explanation includes the connecting material
and the density of connections. How grafting (overlap) refers to this
specification or approved byDirWork reflection by providing standard or
rule references cited.

b) The connection between steel wire mesh panel (overlap) can use
galvanized straps connection. The edges of the rolls of steel woven wire
mesh adjacent shouldreams (overlap) a minimum width of 30 cm or
incorporated in accordance with the plans. Overlap should be made in the
direction corresponding to the picture plan.

c) Cabling alternating lengthwise in pairs with a distance of 1.0 meters per

d) When steel woven wire mesh must be connected to the bottom, sheet steel
woven wire mesh on the bottom side to be clamped / anchored on its
upper side so as to guarantee sheet steel woven wire mesh does not
burden the bottom sheet steel woven wire mesh top.

SKh-1.3.14.4 QUALITY CONTROL

1. Certification

a) The Service Provider must submit a certificate of products validated by


certification bodies authorized to DirWork reflection yang include the name
of the manufacturer, product name, product type number, physical
properties, mechanical properties of steel wire, and other important
information that describes the overall steel wire.

b) The manufacturer is responsible to implement and sustain a quality control


program (ISO) to ensure the suitability of the material to the requirements
specified in the specification. Documentation that describes the quality
control program should be available if requested.
c) When the steel wire was broken before the installation (of the plant) and
during storage, it must be replaced qualify SKH-section 1.3.14.2 and the
Service Provider is responsible for replacing the damaged steel wire.

d) If damage occurs during the execution of the work, the replacement of steel
wire have to be continuous to establish the connection using the methods
specified in this specification or approved by Direkthe Works,

2. Testing

a) Testing Grout
Sver do the work, the Service Provider shall perform the testing of grout in
accordance with AASHTO T106 / ASTM C109 any
40 m3 of concrete used for grouting / grout that has
placed. The results of the testing must be submitted no later than 24 hours
after dliakukan testing.

b) Tensile Test

Sfter the installation of anchors, at least 28 days old concrete dliakukan


tensile test. Tensile test carried out with a hydraulic jack that has a
capacity of 50 tons, the anchor rod is pulled with a hydraulic jack and
observed whether anchors are interested or still does not move.

The number of anchors in the form of interlacing in the test at least 20% of
the total number of anchors. Angkur considered collapsed if the
movement exceeds 0.04 Inch between 1-10 minutes or 0.08 inch within a
period of 60 minutes. Anchor pins are tested at least 3% of the total
number of pins or a minimum of 5 points in accordance with BS-8006-2.

3. Shipping and Storage

a) Each roll of steel wire mesh (wire mesh) must be ensured by the Service
Provider quality with a condition covered with a material that can protect
her, including the ends of the roll, from damage during shipping, water,
sunlight and chemical contamination. Protective Wrap should be
maintained during the period of shipment and storage, and must be
accepted and approved by theDirWork reflection,

b) During storage, the Service Provider must ensure steel wire coils placed in
a dry and covered to protect from damage caused by the construction,
precipitation, chemical compounds strong acidic or alkaline, fire from spark
welding and other environmental conditions
can undermine the value of the physical properties of steel wire, and must
be accepted and approved by the DireWork ksi,

c) Raw steel wire (wire mesh), net steel woven wire (wire net), anchors (wire
rope anchor), binder clips, wire ties and other materials should be stored
under a roof that is waterproof, be separated from the soil surface and
must be protected from any possible damage and rust.

SKh-1.3.14.5 MEASUREMENT AND PAYMENT

1. Measurement

Cable wire mesh or netting is measured by the number of square meters of


the boundary line payment calculated on the picture or on the boundary line of
payment specified in writing by DirWork reflection, This measurement does
not include overlapping connection.

2. Payment

Kuantitas steel wire (wire mesh) or net cable (cable net) was measured as
described above, paid for unity each measurement of prices included in the
Bill of Quantities for the Pay Items listed below. Where the price is already full
compensation for the procurement, importation, installation of wire mesh or
netting cable, final completion and testing of materials, all other expenses
necessary or cost to completion as it should be on the work described in this
section.

NEye omor uraian Satuan


Pembayaran Pengukuran
SKH.1.3.14 (1) Standard wire mesh galvanized (zn) Mether Square
SKH.1.3.14 (2) Standard wire mesh coated galvan (zn-al) Mether Square
SKH.1.3.14 (3) PVC-coated wire mesh standard Mether Square
SKH.1.3.14 (4) Wire mesh with high strength coated Mether Square
galvanized (zn)
SKH.1.3.14 (5) Wire mesh with high strength coated Mether Square
galvan (zn-al)
SKH.1.3.14 (6) Wire mesh with high strength coated Mether Square
PVC
SKH.1.3.14 (7) Standard cable nets coated galvanized (zn) Mether Square
for passive method
SKH.1.3.14 (8) Standard cable nets coated galvan (zn-al) Mether Square
for passive method
SKH.1.3.14 (9) PVC coated cable nets standards for Mether Square
mpassive etode
NEye omor uraian Satuan
Pembayaran Pengukuran
SKH.1.3.14 (10) Standard cable nets coated galvanized (zn) Mether Square
for active methods
SKH.1.3.14 (11) Standard cable nets coated galvan (zn-al) Mether Square
for active methods
SKH.1.3.14 (12) PVC coated cable nets standards for Mether Square
mactive etode
SKH.1.3.14 (13) Cable nets with high strength coated Mether Square
galvanized (zn)
SKH.1.3.14 (14) Cable nets with high strength coated Mether Square
galvan (zn-al)
SKH.1.3.14 (15) Cable nets with high strength coated Mether Square
PVC
SKH.1.3.14 (16) Angkur threaded steel rod (threaded bar) MLong ether
grade 75 diameter ...... .mm
SKH.1.3.14 (17) Angkur prestressing steel rod (prestressed MLong ether
bar) Grade 150 diameter ...... .mm
SKH.1.3.14 (18) Angkur alternating steel (wire rope anchor) MLong ether
...... ... mm diameter

SKH-1.3.14 -15
LAMPIRAN

PeRetaining lat Iron Anchor (Anchor Plate)

Besi for the anchor rod (Bar Anchor)


Cable alternating (Wire Rope)

centralizers

SKH-1.3.14 -16