MeQ-Pak TDI ANEXA 3

The MeQ-Pak utilises its self-powered turbine to provide


energy to drive the injection system.
The flow of product through the MeQ-Pak drives the turbine,
which in turn drives the positive displacement pump heads
via a gearbox. The number of pump heads is determined by
the ratio of additive injection required. As the main product
flow varies, the proportional change in speed of the turbine,
ensures that the rate of injection is adjusted accordingly.
The advantages of this self-contained system are its mechanical simplicity and rugged
design requiring minimum maintenance and operator interaction. This reliability makes the
MeQ-Pak extremely cost-effective during operation and installation.
General Arrangement

Benefits MeQ-Pak configurations. The actual Multiple Additives


quantity and size of pumps is dependent Multiple additives are capable of being
• Proven Technology on the number of additives and the injected via a single MeQ-Pak.
• Simple Installation injection rate(s) required. A maximum of 4 separate additives lines
• Proven Reliability are possible, dependent upon injection
• Low Maintenance Additive Supply rates required. Call factory for multiple
• Self Contained The MeQ-Pak requires a constant, additive pricing.
positive head, additive supply. Typically
Features this would be an appropriately sized Calibration
additive storage tank supplying a To facilitate the clean and safe
Arrangements minimum of 0.3 metres of positive head, calibration of the MeQ-Pak turbine,
The MeQ-Pak turbine driven injector and rigorously purged of all air. in-line calibration vessels are available as
is capable of being mounted both Call factory for range of additive supply an upgrade option. Approved, laboratory
horizontally and vertically. However to tanks available. certified, glass calibration vessels, sized
facilitate non-horizontal installation, to suit are pre-installed into the additive
certain components must be re- Operating Range supply line and can be utilised via a
orientated. The MeQ-Pak will therefore Each metering pump is supplied with a 3-way valve, to calibrate the injection
be supplied for standard horizontal fully adjustable stroke range, from rate without the need for additive
mounting as per General Arrangement 0-100% via a lockable vernier dial. exposure or operational rescheduling.
drawing, unless otherwise requested. The final MeQ-Pak configuration will
be engineered with the target injection
Pump Selection rate at the mid range point of the stroke
The Pump Selection Table is offered as a size, with upper and lower injection rates
guide for the pricing of different specified by Honeywell Enraf.
Technical Specification

Flow
Accuracy : Better than ± 1.5%
Repeatability : Better than ± 1.0%
Max Flow - Wildstream : 4” 35 - 135 M³/hr
: 6” 50 - 275 M³/hr
: 8” 90 - 500 M³/hr
: 10” 150 - 800 M³/hr
Max Flow - Additive : 4” 8.00 L/min 3500 ppm
: 6” 10.70 L/min 2500 ppm
: 8” 19.60 L/min 2300 ppm
: 10” 19.60 L/min 1500 ppm
Max Working Pressure : 15 Bar
Max Viscosity - Wildstream : 10 cst.
Max Viscosity - Additive : 2000 cst.
Pressue Drop - Wildstream : Less than 1 Bar
Additive Supply Pressure : 300mm Positive Head - Minimum
Environmental
Ambient Temperature : -25ºC to +65ºC
Humidity : 5 to 95% without condensation.
Approvals : ATEX, CE Marked for Zone 1
: PED 8” & 10” SEP 4” & 6”
T Rating : T4
Materials
Turbine Casing : Cast Steel - ASTM A216 WCB
Turbine Axial Flow Impeller : 304 Stainless Steel
Turbine Mechanical Seal : Stainless Steel, Carbon, Viton
Metering Pumps : 316 Stainless Steel
Metering Pump Seals : PTFE
Mechanical Drive Casing : Cast Iron - Grade 250
Paint Finish : Hammercote Enamel - Ref. H/126
Mechanical
Major Components : Strainer, Metering Pump(s), Turbine Unit, Mech Seal, Check Vv
Gearbox, Coupling & Spider, MGH Drive Mechanism, Relief V
Turbine Connections : ANSI 150 lb RF Flanged
Additive Inlet Connection(s) : 1/2”, 3/4” or 1”NPT - Arrangement depending
Weight
4” Turbine Assembly : Approx 150 kg (Depending on No. of Pumps fitted)
6” Turbine Assembly : Approx 240 kg (Depending on No. of Pumps fitted)
8” Turbine Assembly : Approx 380 kg (Depending on No. of Pumps fitted)
10” Turbine Assembly : Approx 560 kg (Depending on No. of Pumps fitted)
Options
Bypass : System Bypass Valve
Calibration : In-line calibration vessel ( 1, 2 & 5 Litre )
Reconciliation : Additive discharge line PD Meter
Additive Storage : Additive Supply Tanks - Various models

Pump Selection Table

Pump Selector - PPM Range

A B C D E EE EEE
Turbine Size

4” 0-50 51-200 201-450 451-800 801-1350 801-2700 N/A


6” 0-20 21-80 81-150 151-300 301-550 301-1100 301-1650
8” 0-10 11-40 41-90 91-175 171-280 171-560 171-840
10” 0-7 7-30 31-60 61-110 111-190 111-380 111-570
Identification Code

Pos 1, 2 Manufactured Product


6 9
Pos 3, 4 Product Family
1 0 Turbine Driven Injector
Pos 5, 6 Model
M Q MeQ-Pak
Pos 7, 8 Size
0 4 4” ( WildStream Flowrates 35 - 135 M³/hr )
0 6 6” ( WildStream Flowrates 50 - 275 M³/hr )
0 8 8” ( WildStream Flowrates 90 - 500 M³/hr )
1 0 10” ( WildStream Flowrates 150 - 800 M³/hr )
Pos 9 Pump Selection (See Pump Selector Table)
A Pump Package A
B Pump Package B
C Pump Package C
D Pump Package D
E Pump Package E
F Pump Package F
G Pump Package G
H Pump Package H
Pos 10 System Bypass Valve
0 Not required
1 Yes
Pos 11 Inline Calibration Vessel
0 Not Required
1 1 Litre
2 2 Litre
5 5 Litre
Pos 12 Flowmeter
0 Not Required
1 Yes
Pos 13 N/A
0 Not Required

6 9 1 0 M Q 0 4 A 0 0 0 0 Typical identification code

6 9 1 0 M Q 0 Your identification code

For More Information


To learn more about Honeywell Enraf’s
solutions, contact your Honeywell Enraf
account manager or visit
www.honeywellenraf.com.

Americas Asia Pacific


Honeywell Enraf Americas, Inc. Honeywell Pte Ltd.
2000 Northfield Ct. 17 Changi Business Park Central 1
Roswell, GA 30076 Singapore 486073
USA Phone: +65 6355 2828
Phone: +1 770 475 1900 Email: enraf-sg@honeywell.com
Email: enraf-us@honeywell.com

Europe, Middle East and Africa


Honeywell Enraf
Delftechpark 39
2628 XJ Delft
The Netherlands
EN-09-30-ENG
Phone: +31 (0)15 2701 100 August 2009
Email: enraf-nl@honeywell.com © 2009 Honeywell International Inc.
0 1 2 3 4 5 6 7 8 9

CusOrd. PrdOrd.
Quote Ref. StdOrd. Mat No.
TITLE/DESCRIPTION DRAWING No. FN1_H01a_BD-RMG ISSUE
This drawing is the property of MeqPak TDI __ SELF-POWERED TURBINE
Honeywell Process Solutions
and is protected by copyright.
This drawing and or it's Intellectual Honeywell Enraf SELF-POWERED,
05-00129 A
Property must not be redistributed,
modified, altered or copied without Enterprise Drive, Chesterfield TURBINE DRIVEN
express permission of Honeywell Process Solutions.
S42 5UZ
Honeywell Process Solutions
Terms and Conditions apply. ADDITIVE INJECTION
1 E400048 01/07/2014 Copies of those Terms and Conditions
are available on request. PERFORMANCE CHARACTERISTICS
ISSUE STATUS/DESCRIPTION DRN/MOD CHK'D APPR'D DATE TEL: +44 (0)1246 50150 FAX: +44 (0)1246 50150 MeqPaq TDI Performance Characteristics Sht. 1 of 5
0 1 2 3 4 5 6 7 8 9

THIRD ANGLE PROJECTION USED ON / REFERENCE DRG No'S


STK No's 69-10-xx-xx
BILL OF MATERIALS

DIM 'A+'

x"NB
TURBINES DIM'S ARE FOR ANSI.150 R.F. FLANGES.
ANSI.150
DIM 'A' X ALL DIMENSION's ARE FOR REFERENCE ONLY.
PRODUCT FLOW PRODUCT FLOW
+ ADDITIVE

T FLO
W TURBINE DIM 'A' DIM 'A+' DIM 'B' DIM 'C' DIM 'D'
PR ODUC

2" 370mm 371.5mm Ø153mm 217mm 580mm MIN

PSx

x:x 4" 503mm 504.5mm Ø230mm 290mm 580mm MIN

ADDITIVE IN
6" 703mm 704.5mm Ø280mm 320mm 610mm MIN

DIM 'D'
8" 803mm 804.5mm Ø343mm 415mm 610mm MIN
DIM 'B'

VERNIER 10" 933mm 934.5mm Ø407mm 480mm 620mm MIN

DIM 'A+':- INCLUDES WITCHES HAT STRAINER, WHEN FULLY INSERTED.

DIM 'C':- DEPENDING ON ADDITIONAL EQUIPMENT FITTED.

DIM 'D':- DEPENDING ON EQUIPMENT FITTED.

PLAN VIEW

NOTES
MeQ-Pak ATEX & PED LABELS
1. THIS DRG IS A TOP LEVEL REPRESENTATION OF THE MeQ-Pak.

FOR FULL DETAILS SEE DRG PACK SERIES MQP1/04/_ AND

TECHNICAL CONSTRUCTION FILE No.LPS-TF-001.


HONEYWELL ENRAF METERING PUMP LABEL
2. THE EQUIPMENT DOES NOT CONTAIN MORE THAN

7.5% MAGNESIUM BY MASS.


MeQ-Pak ATEX LABEL
3. A WITCHES HAT STRAINER IS SUPPLIED WITH THE TURBINE AND
x" SHOULD BE FITTED AT THE INLET TO THE TURBINE.
DIM 'C' x" THIS IS FABRICATED FROM 1.5mm STAINLESSS STEEL SHEET AND

WILL NEED TO HAVE A GASKET FITTED TO BOTH SIDES.

ALLOWANCES FOR THIS SHOULD BE MADE WHEN DETERMINING

THE SPACE REQUIRED TO FIT THE TURBINE INTO THE PIPELINE.


ADDITIVE IN

PRODUCT FLOW PRODUCT FLOW

ADDITIVE INLET (0.5"BSPT)


FRONT VIEW

VIEW ON ARROW 'X'


SHOWING PIPEWORK FROM PUMP HEAD
TO ADDITIVE INLET

CusOrd. PrdOrd.
Quote Ref. StdOrd. Mat No.
TITLE/DESCRIPTION DRAWING No. FN1_H01a_BD-RMG ISSUE
This drawing is the property of MeqPak TDI __ SELF-POWERED TURBINE
Honeywell Process Solutions
and is protected by copyright.
This drawing and or it's Intellectual Honeywell Enraf SELF-POWERED,
TURBINE DRIVEN
MQP1/04/001 A
Property must not be redistributed,
modified, altered or copied without Enterprise Drive, Chesterfield
A ORGINAL P.C. P.C. K.E. 26.07.10 express permission of Honeywell Process Solutions.
Honeywell Process Solutions S42 5UZ ADDITIVE INJECTION
E400048 01/07/2014
Terms and Conditions apply.
Copies of those Terms and Conditions ASSEMBLY
are available on request.
ISSUE STATUS/DESCRIPTION DRN/MOD CHK'D APPR'D DATE TEL: +44 (0)1246 50150 FAX: +44 (0)1246 50150 General Assembly Dimensions 4", 6", 8" ,10" Sht. 2 of 5
0 1 2 3 4 5 6 7 8 9

ASV
(ANTI-SYPHON CALIBRATION POINT
VALVE 3 BAR)

INJECTION
BYPASS VALVE RETURN TO TANK
(OPTION)

FLOWMETER
+ TOTALISER
(OPTION)
TOTLALISER

INJECTION
POINT

ANSI.150
PRODUCT FLOW
STRAINER
+ ADDITIVE
PRODUCT FLOW

CALIBRATION
JAR
(OPTION)

MEQPAK
DRIVE ASSEMBLY

(RETURN TO INLET
NOT PREFFERED OPTION)
RVP PLV
(RELIEF VALVE (PUMP LOADING
PUMP 15 BAR) VALVE 1 BAR)

PSxx
PUMP

x:x
GEAR BOX

Single pump & single additive shown


options for multiple additve and
ADDITIVE IN
pump congfiguration availble

CusOrd. PrdOrd.
(NO ISOLATION OR CHECK VALVES Quote Ref.
TO BE INSTALLED IN THIS LINE) StdOrd. Mat No.
TITLE/DESCRIPTION DRAWING No. FN1_H01a_BD-RMG ISSUE
This drawing is the property of MeqPak TDI __ SELF-POWERED TURBINE
Honeywell Process Solutions
and is protected by copyright.
This drawing and or it's Intellectual Honeywell Enraf MeqPak
2
Property must not be redistributed,

1 Under design 15/11/2013


modified, altered or copied without
express permission of Honeywell Process Solutions.
Honeywell Process Solutions
Terms and Conditions apply.
Enterprise Drive, Chesterfield
S42 5UZ
General Assembly Overview P&ID
(c/w Options)
MeqPak-GA-P&ID
2 UNDER DESIGN + FM & CJ OPTION E400048 14/07/2014 Copies of those Terms and Conditions
are available on request.
ISSUE STATUS/DESCRIPTION DRN/MOD CHK'D APPR'D DATE TEL: +44 (0)1246 50150 FAX: +44 (0)1246 50150 MeqPek General Assembly + Options Information P&ID Sht. 3 of 5