Flow................................................................................................................................................................................... 2
Magnetic........................................................................................................................................................................ 2
Vortex............................................................................................................................................................................ 5
Coriolis.......................................................................................................................................................................... 9
Transmitters ................................................................................................................................................................ 11
Density ............................................................................................................................................................................ 11
Fork Density Meter..................................................................................................................................................... 12
Viscosity.......................................................................................................................................................................... 12
Fork Viscosity Meter.................................................................................................................................................. 12
Pressure ........................................................................................................................................................................... 12
Rosemount™ 2088 Gage and Absolute Pressure Transmitter ................................................................................ 12
Rosemount™ 2090F Hygienic Pressure Transmitter............................................................................................... 13
Rosemount™ 2051 Pressure Transmitter ................................................................................................................. 13
Rosemount™ 3051P In-Line Pressure Transmitter ................................................................................................. 14
Rosemount™ 3051S Series of Instrumentation ....................................................................................................... 15
Manifolds .................................................................................................................................................................... 16
Continuous Level............................................................................................................................................................ 16
Rosemount™ 1199 Diaphragm Seal System............................................................................................................ 16
Rosemount™ 2051L Level Transmitter ................................................................................................................... 17
Rosemount™ 3051L Level Transmitter ................................................................................................................... 17
Rosemount™ 3051SAL Level Transmitter .............................................................................................................. 17
Rosemount™ 3100 Level Transmitter – Ultrasonic ................................................................................................ 18
Rosemount™ 5300 Level Transmitter - Guided Wave Radar ................................................................................ 18
Rosemount™ 5400 Level Transmitter - Non-Contacting Radar............................................................................. 19
Point Level Detection..................................................................................................................................................... 20
Rosemount™ 2110 Level Switch - Vibrating Fork ................................................................................................. 20
Rosemount™ 2120 Level Switch - Vibrating Fork ................................................................................................. 20
Rosemount™ 2130 Level Switch - Vibrating Fork ................................................................................................. 20
Rosemount™ 2140 Level Detector - Vibrating Fork............................................................................................... 20
Temperature .................................................................................................................................................................... 21
Transmitters ................................................................................................................................................................ 21
Sensors ........................................................................................................................................................................ 21
Flow
Magnetic
Measures the volumetric flow of liquid and slurries only. Fluid must be conductive, conductivity of 5
microsiemens/cm or greater.
Magmeters offer no obstruction, which make them ideal for a range of applications, from clean and sanitary liquids to
slurries and abrasives and corrosives fluids.
These meters are vulnerable to electromagnetic interference.
Rosemount 8750W Magnetic Flow Meters for Utility Water and Wastewater (águas residuais)
Applications
For utility water and wastewater;
Flanged process connections Welded coil housing;
½-in. to 48-in.;
3-in. to 36-in.;
High current pulsed DC technology ideal for high solids or slurry applications;
Pulsed DC technology;
Standard, grounding, and bullet-nose electrodes available;
Table 7: Sizing guidelines
½-in. to 4-in.;
Pulsed DC technology;
Variety of industry standard process connections;
Suitable for CIP/SIP.
Table 9: Sizing guidelines
Not CE Marked.
Vortex
They are volumetric flowmeter, based on the principle of Von Kármán. The volumetric flow is in direct proportion of
the frequency of the vortex formed.
𝑓𝑓
𝑄𝑄 =
𝑘𝑘
Where 𝑄𝑄 is the volumetric flow, 𝑓𝑓 is the vortex shedding frequency, and 𝑘𝑘 is a factor dependent of the geometry and
Reynolds Number.
𝜌𝜌𝑣𝑣 𝐷𝐷
𝑅𝑅𝑅𝑅 =
𝜇𝜇
Where 𝑅𝑅𝑅𝑅 is Reynolds Number, 𝜌𝜌𝑣𝑣 flow velocity, 𝐷𝐷 is the diameter of the tube, and 𝜇𝜇 is the dynamic viscosity.
The flowmeter should be located in a place where vibration and electrical interference levels are low. Both of these
influences can decrease the signal-to-noise ratio at the input to the transmitter. This reduction can degrade the ability
of the meter to measure low flows.
Process fluids: liquid, gas, and steam applications.
Fluids m/s
Liquids �54/𝜌𝜌
Gases �54/𝜌𝜌
The 𝜌𝜌 is the process fluid density at flowing conditions in 𝑘𝑘𝑘𝑘/𝑚𝑚3 .
Table 12: Maximum Measurable Meter Velocities
Fluids m/s
Liquids �134,000/𝜌𝜌 or 7.6
Gases �134,000/𝜌𝜌 or 76
The 𝜌𝜌 is the process fluid density at flowing conditions in 𝑘𝑘𝑘𝑘/𝑚𝑚3 .
Fluids m/s
Liquids �54/𝜌𝜌
Gases �54/𝜌𝜌
The 𝜌𝜌 is the process fluid density at flowing conditions in 𝑘𝑘𝑘𝑘/𝑚𝑚3 .
Table 14: Maximum Measurable Meter Velocities
Fluids m/s
Liquids �134,000/𝜌𝜌 or 7.6
Gases �134,000/𝜌𝜌 or 91.4
The 𝜌𝜌 is the process fluid density at flowing conditions in 𝑘𝑘𝑘𝑘/𝑚𝑚3 .
Flange Rating: up to 1500#.
Fluids m/s
Liquids �54/𝜌𝜌
Gases �54/𝜌𝜌
The 𝜌𝜌 is the process fluid density at flowing conditions in 𝑘𝑘𝑘𝑘/𝑚𝑚3 .
Table 16: Maximum Measurable Meter Velocities
Fluids m/s
Liquids �134,000/𝜌𝜌 or 7.6
Gases �134,000/𝜌𝜌 or 91.4
The 𝜌𝜌 is the process fluid density at flowing conditions in 𝑘𝑘𝑘𝑘/𝑚𝑚3 .
Fluids m/s
Liquids �54/𝜌𝜌
Gases �54/𝜌𝜌
The 𝜌𝜌 is the process fluid density at flowing conditions in 𝑘𝑘𝑘𝑘/𝑚𝑚3 .
Table 19: Maximum Measurable Meter Velocities
Fluids m/s
Liquids �134,000/𝜌𝜌 or 7.6
Gases �134,000/𝜌𝜌 or 91.4
The 𝜌𝜌 is the process fluid density at flowing conditions in 𝑘𝑘𝑘𝑘/𝑚𝑚3 .
Turndown 38:1;
Line Size: Flanged ½-in to 12-in;
Fluids m/s
Liquids �54/𝜌𝜌
Gases �54/𝜌𝜌
The 𝜌𝜌 is the process fluid density at flowing conditions in 𝑘𝑘𝑘𝑘/𝑚𝑚3 .
Table 14: Maximum Measurable Meter Velocities
Fluids m/s
Liquids �134,000/𝜌𝜌 or 7.6
Gases �134,000/𝜌𝜌 or 91.4
The 𝜌𝜌 is the process fluid density at flowing conditions in 𝑘𝑘𝑘𝑘/𝑚𝑚3 .
Coriolis
Coriolis meters are mass flowmeters, and density meters.
Coriolis meters can measure more than one process variable. Besides mass flow, they can also measure density,
temperature, and viscosity.
They are virtually unaffected by changes in fluid pressure, temperature, viscosity, and density. As a result, Coriolis
meters can be used on a variety of process fluids without recalibration and without compensating for parameters
specific to a particular type of fluid.
Coriolis meters have the highest accuracy of all types of flowmeters. Because Coriolis meters measure mass flow
directly, they have fewer sources of errors.
The time difference between the waves is measured and is directly proportional to the mass flow rate.
A change in the mass of the fluid contained inside the tubes causes a corresponding change to the tube natural
frequency. The frequency change of the tube is used to calculate density.
Coriolis meters have no Reynolds number constraints, and can be applied to almost any liquid or gas flowing at a
sufficient mass flow to affect vibration of the flowmeter. Typical liquid applications include foods, slurries, harsh
chemicals, and blending systems.
Overview
ELITE
T-Series
HPC010P
Micro Motion R-Series General Purpose Coriolis Flow and Density Meters
They are ideally suited for general purpose applications that typically require repeatable, reliable, low-maintenance
measurements;
Basic liquid mass flow, volume flow, and density measurement performance in a compact design;
Line Size: 1/4" (DN6) - 2" (DN50);
Pressure Range: up to 1450 psig (100 barg);
Temperature Range: -100 to 150°C;
Turndown 20:1
Table 15: Maximum flow rate limits
Mass Volume
Liquids 87,100 kg/h 87,100 l/h;
Gases 18,137 kg/h 25,515 Nm3/h
Micro Motion F-Series Compact, Drainable Coriolis Flow and Density Meters
Delivering highly reliable and robust measurement, F-Series flow meters are the preferred choice for process control
applications.
Achieve highly accurate mass volume flow and density measurement in applications that require a compact, drainable
design
Line Size: 1/4" (DN6) - 3" (DN80);
Turndown: 20:01;
Table 16: Maximum flow rate limits
Mass Volume
Liquids 272,000 kg/h 272,000 l/h;
Gases 47,505 kg/h 66,829 Nm3/h
Transmitters
Density
Tuning Fork Densitometers
Where K is the system stiffness, M is the transducer mass, k is the system constant, and 𝜌𝜌 is the fluid density.
These densitometers make use of the natural frequency of low-mass tuning forks. In some cases, the fluid is taken into
a small chamber in which the electromechanically driven forks are situated. In other cases, the fork is inserted directly
into the liquid. Calibration is necessary in each application.
5. Programmable and computerized versions are available. Programmed versions make all the corrections
automatically. They provide the output of live density, density at reference conditions, relative density, specific
gravity, concentration, solid contents, etc.
The disadvantages include:
1. They do not relate directly to primary measurements; therefore, they must be calibrated.
2. They all have problems in measuring multiphase liquids.
Process Viscosity effect No effect for 0–50 cP (±4 kg/m3 (±0.004 g/cm3) for 50–200 cP)
Process Temperature Effect (Corrected) ±0.1 kg/m3 per °C (±0.0001 g/cm3 per °C)
Temperature Range –50 °C to +200 °C (–58 °F to +392 °F)
Pressure Range 207 bar (3000 psi)
Viscosity
• Dynamic viscosity
• Kinematic viscosity
• Referred viscosity
• Density
• Referred Density/Specific Gravity
• °API
Pressure
Rosemount™ 2088 Gage and Absolute Pressure Transmitter
Service: Liquid, gas, and vapor applications
Rangedown Up to 50:1
Communication Protocol 4-20 mA HART®, 1-5 V Low Power HART®
Measurement Range Up to 4,000 psig (275,8 bar) Gage, Up to 4,000 psia (275,8 bar) Absolute
Rangedown Up to 20:1
Communication Protocol 4-20 mA HART®
Measurement Range Up to 300 psig (20,7 bar) Gage, Up to 300 psia (20,7 bar) Absolute
Measurement Range Up to 20000 psig (1378,95 bar) Gage, Up to 20000 psia (1378,95 bar) Absolute
Process Wetted Material 316L SST, Alloy C-276
Diagnostics Basic Diagnostics, Power Advisory Diagnostics
Process Wetted Material 316L SST, Alloy C-276, Alloy 400, Tantalum, Gold-plated Alloy 400, Gold-plated 316L
SST
Diagnostics Basic Diagnostics, Power Advisory Diagnostics
Measurement Range Up to 300 psig (20,7 bar) Gage, Up to 150 psia (10,3 bar) Absolute
Process Wetted Material 316L SST mechanically polished and electropolished to Ra < 15 µ-in. (0.38 µ-m)
Measurement Range Up to 10000psi (689,47 bar) Gage, Up to 10000psia (689,47 bar) Absolute
Process Wetted Material 316L SST, Alloy C-276
Process Wetted Material 316L SST, Alloy C-276, Tantalum, Gold-plated 316L SST
Diagnostics Basic Diagnostics
Rangedown Up to 150:1
Communication Protocol 4-20 mA HART, WirelessHART®, FOUNDATION™ Fieldbus
Measurement Range Up to 150 psi (10.34 bar) Differential with maximum working pressure up to 15,000 psi (1034
bar)
Process Wetted Material Alloy C-276
Diagnostics Basic Diagnostics, Power Advisory Diagnostics, Advanced Diagnostics
Manifolds
Rosemount™ 304 Conventional Manifold
Attaches to a transmitter with a traditional or coplanar flange;
Designed for multivariable, static and differential pressure transmitters, this manifold allows instrument isolation,
controlled venting and protection from leaking to ensure measurement integrity;
2-,3- and 5-valve configuration for assembly to multi-variable, absolute, gage and differential pressure transmitters;
Maximum Operating Temperature 1000°F (538°C)
Manifold Material 316 SST/316L SST, Carbon Steel
2-,3- and 5-valve configuration for multivariable, absolute, gage and differential pressure transmitters;
Maximum Operating Temperature 1000°F (538°C)
Process Connections 1/4"�-18 NPT female, 1/2"�-14 NPT female, 1/2"�-14 female NPT flange adapter, 12 mm
ferrule tube flange adapter
Process Connection Orientation Parallel with transmitter, 90° to transmitter
Block-and-bleed and 2-valve configurations provide instrument isolation and drain/vent capabilities
Maximum Operating Temperature 1000°F (538°C)
Manifold Material 316 SST/316L SST, Alloy C-276, Alloy 400
Packing Material PTFE, Graphite-based
Continuous Level
Rosemount™ 1199 Diaphragm Seal System
eal System Type Direct Mount, Remote Mount, Tuned-System, Balanced System
�Hygienic
Process Wetted Material 316L SST, Alloy C-276, Alloy 400, Tantalum, Gold-plated Alloy 400, Gold-plated 316L
SST, see PDS for full list of materials
Process Temperature Range Based on fill fluid - Maximum 401°F (205°C), Minimum -157°F (-105°C)
Communication Protocol 4-20 mA HART®, WirelessHART®, FOUNDATION™ Fieldbus, PROFIBUS®, 1-5 V
Low Power HART®
Seal System Type Direct Mount, Tuned-System
�Hygienic
Process Wetted Material 316L SST, Alloy C-276, Alloy 400, Tantalum, Gold-plated Alloy 400, Gold-plated 316L
SST, see full specs for complete list of materials
Diagnostics Basic Diagnostics, Power Advisory Diagnostics, Advanced Diagnostics
Temperature compensation is integrated and you can equip the Rosemount 3100 with an external sensor for dynamic
temperature compensation.
Probe Types Rigid single lead, Segmented single lead, Flexible single lead, Flexible twin lead, Coaxial, PTFE coated
probes
3301 Guided Wave Radar Level Transmitter (interface available for fully submerged probe) ★
3302 Guided Wave Radar Level and Interface Transmitter
Rosemount™ 5300 Level Transmitter - Guided Wave Radar
The Rosemount 5300 Level Transmitter is ideal for challenging measurements on liquids, slurries, and solids, offering
state of the art reliability and safety features in level and interface applications.
5301 Guided Wave Radar Liquid Level or Interface Transmitter (interface available for fully
submerged probe)
5302 Guided Wave Radar Liquid Level and Interface Transmitter
5303 Guided Wave Solids Level Transmitter
Rosemount™ 5400 Level Transmitter - Non-Contacting Radar
The Rosemount 5400 Level Transmitter provides accurate level measurements of liquids, slurries, and solid materials.
It measures the level top down and is therefore unaffected by most fluid property changes, like density and viscosity.
Operating Pressure Full vacuum to 232 psi (Full vacuum to 16 bar)
Operating Temperature -40 to 302°F (-40 to 150°C), -67 to 392°F (-55 to 200°C) for parabolic antenna
Communication Protocol 4-20 mA/HART®, Foundation™ Fieldbus, Modbus®
Safety TÜV tested and WHG approved for overfill prevention
Antenna Type Cone antenna, Rod antenna, Process seal antenna, Parabolic antenna
Operating Frequency Low or high frequency options (6 GHz or 26 GHz)
Rosemount 5401
Rosemount 5401 is a low-frequency non-contacting radar designed for use in tough, challenging turbulence and foam
applications.
Characteristics include:
• Ideal for applications with obstacles, condensation, vapor, dust, and contamination, or where there is a risk
of deposits forming on the antenna
• Condensation-resistant cone or rod antennas
Rosemount 5402
Rosemount 5402 is a high-frequency non-contacting radar designed for outstanding performance in a wide range of
applications and process conditions.
Characteristics include:
Rosemount 5408
26 GHz FMCW with unique energy efficient radar chip
Accuracy ± 0.08 in. (± 2 mm)
Measurement Range 131 ft (40 m), 82 ft (25 m) for Rosemount 5408:SIS in Safety mode
Operating Pressure 1450 psi (100 bar)
Operating Temperature -76 to +482 °F (-60 to +250 °C)
Operating Pressure Full vacuum to 1450 psi (Full vacuum to 100 bar)
Operating Temperature -40 to 302 °F (-40 to 150 °C)
Can be operated using the sun or battery as a power source with the 12Vdc option
3-A and EHEDG certificates for hygienic applications. Compliance with FDA and ASME-BPE standards
Operating Pressure Full vacuum to 1450 psig at 122 °F psi (100 barg at 50 °C)
Operating Temperature -40 to 302 °F (-40 to 150 °C) as standard. -94 to 500 °F (-70 to 260 °C) as option
Certifications/Approvals TBD
Optional: Functional / partial proof test. Only Rosemount 2140:SIS: Remote partial proof-test
Temperature
Transmitters
Rosemount™ 248 Temperature Transmitter
Input Single sensor capability with universal sensor inputs (RTD, T/C, mV, ohms)
Output Signal 4-20 mA /HART® protocol
Housing DIN B head mount or rail mount
Diagnostics Basic diagnostics including open/short sensor diagnostics
Output Signal 4-20 mA /HART® protocol, FOUNDATION™ fieldbus protocol, PROFIBUS® PA protocol
Housing Field mount, DIN A head mount or rail mount
Display/Interface LCD Display or LCD Display with Local Operator Interface (LOI)
Diagnostics Basic diagnostics, Hot Backup™ capability, sensor drift alert, thermocouple degradation, min/max
tracking
Minimum and maximum temperature tracking observes temperature extremes for easy troubleshooting
Sensors
Rosemount™ 214C RTD Temperature Sensor
single or dual element resistant temperature detector (RTD) that covers a wide range of temperatures,
from -321 to 1112°F (-196 to 600°C).
Time Constant / Response 10.8 seconds maximum required to reach 50% sensor response when tested in flowing
water according to IEC 60751:2008
Sensor covers wide range of temperatures -328 to 572 °F (-200 ° to 300 °C) to meet application demands
Non-intrusive design eliminates need for process penetration of fluids with toxic properties for added safety
Cut-to-fit capability allows sensor to be shortened with a standard tube cutter to meet application specifications