Вы находитесь на странице: 1из 1

JVA Specifications

SPECIFICATIONS Z11 Z13 Z14 Z18 Z114 Z28 SOLAR PANEL SPEC Z11 Z13 Z14 Z18 Z114 Z28
Stored energy 3J 5J 6J 12J 17J 2x6J Recommended battery 50 Ah 50 Ah 50 Ah 105 Ah 105 Ah 105 Ah
Maximum Output energy 1.8J 3J 5J 8J 14J 2x4J Solar panel 75w 75w 75w 100w 100w 100w
Output voltage maximum 10kv 10kv 10kv 10kv 10kv 10kv Solar panel calculations based on an installation in Johannesburg, South Africa.
Location-specific recommendations available on request.
Output voltage LCD display Keypad Keypad ü ü ü
Return voltage LCD display Keypad Keypad ü ü ü ü WARRANTY Z11 Z13 Z14 Z18 Z114 Z28
Backup time maximum 24hrs 24hrs 18hrs 18hrs 16hrs 14hrs
Ext 16VAC transformer
ü ü ü ü ü ü
2-year warranty ü ü ü ü ü ü
Battery volts 12v 12v 12v 12v 12v 12v
Battery capacity 7Ah 7Ah 7Ah 7Ah 9Ah 7Ah CERTIFICATION Z11 Z13 Z14 Z18 Z114 Z28
Pulse frequency 0.8 Hz 0.8 Hz 0.8 Hz 0.8 Hz 0.8 Hz 0.8 Hz 2-year warranty
Compliant (IEC60335-2-76) ü ü ü ü ü ü
Pulse width 0.3ms 0.3ms 0.3ms 0.3ms 0.3ms 0.3ms
Alarm delay FEATURES
Siren time out
* * * * * * Z11 Z13 Z14 Z18 Z114 Z28

* * * * * * Fence monitor
ü ü ü ü ü ü
Bi-Polar Capability ü ü ü Gate (aux.) monitor
ü ü ü ü ü ü
Low voltage monitor
* Programmable by keypad ü ü ü ü ü ü
RECOMMENDED
Siren driver
ü ü ü ü ü ü
SERIES WIRE LENGTH Z11 Z13 Z14 Z18 Z114 Z28 Strobe driver ü ü ü ü ü ü
1.2mm s/steel 0.6km 0.8km 1km 1.5km 2km 2x1km Armed Response
ü ü ü ü ü ü
1.6mm s/steel 1.2km 1.4km 1.6km 2km 2.5km 2x1.6km On/Off reset key
ü ü ü ü ü ü
2mm s/steel 1.8km 2.1km 2.4km 3.3km 3.6km 2x2.4km Remote control option
ü ü ü ü ü ü
1.2mm braided galvanized 2km 3km 4km 8km 10km 2x4km Battery backup
ü ü ü ü ü ü
2mm braided galvanized 2.5km 3.5km 5km 8km 10km 2x5km Keypad LCD Optional
ü ü ü ü ü ü
2.24 galvanized HSS 3km 4km 6km 10km 14km 2x6km Multi-Keypad Compatible
ü ü ü ü ü ü
1.6mm aluminium wire 6km 8km 10km 20km 25km 2x10km Keypad Voltage Display
ü ü ü ü ü ü
Keypad tamper Alert
ü ü ü ü ü ü
DIMENSIONS Z11 Z13 Z14 Z18 Z114 Z28 Microprocessor
ü ü ü ü ü ü
Size (height, width, depth) mm Programmable
ü ü ü ü ü ü
Weight (without battery) 2.0kg 2.0kg 2.1kg 2.4kg 3kg 2.4kg
Earth Monitoring
ü ü ü ü ü ü
Security
ü ü ü ü ü ü
POWER CONSUMPTION Z11 Z13 Z14 Z18 Z114 Z28
Software Controllable
ü ü ü ü ü ü
Average current draw
Solar Power Option
ü ü ü ü ü ü
Number of Zones 1 1 1 1 1 2
Peak current draw 1400mA Multi-Zone Pulse Sync ü ü ü ü ü ü
All energizers in the Z-Range can be used in a Multi-Zone Network

JVA RANGE CATALOGUE JVA RANGE CATALOGUE