Вы находитесь на странице: 1из 5

EDIFICIO

C.S. = Coeficiente Sísmico


CORTANTES ESTATICOS

P. SISMICO = 1111.1942979
C.S. = ZUCS/R
C.S.X. = 0.1768

C.S.Y. = 0.1768
VE = Valores Estáticos
VEX = 196.44
VEY = 196.44

Z= 0.45
U= 1.00
S= 1.10
C= 2.50
Tn= 0.24

Tp= 1.00
Tl= 1.60
TABLA: MASA POR PISO
PISO UX UY H
tonf-s²/m tonf-s²/m m
Story6 1.05676 1.05676 2
Story5 16.42439 16.42439 2.45
Story4 23.31178 23.31178 2.45
Story3 23.31178 23.31178 2.45 1.05676 1.05676
Story2 23.28408 23.28408 2.45 16.42439 16.42439
Story1 23.44056 23.44056 2.55 23.31178 23.31178
Base 2.44224 2.44224 14.35 23.31178 23.31178
MASA TOTAL:113.27159 23.28408 23.28408
23.44056 23.44056
2.44224 2.44224

1.34389938
IRREGULARIDAD DE RIGIDEZ

RIGIDEZ X-X RIGIDEZ Y-Y


Story RELACIÓN 1 RELACIÓN 2 RELACIÓN 1 RELACIÓN 2
tonf/m tonf/m
Story8 23197.99 26017.34
Story7 47410.16 2.04 50603.62 1.94
Story6 65739.77 1.39 67658.75 1.34
Story5 81774.05 1.24 1.80 82084.13 1.21 1.71
Story4 99474.73 1.22 1.53 98959.19 1.21 1.48
Story3 125978.98 1.27 1.53 126173.19 1.28 1.52
Story2 174226.08 1.38 1.70 173682.58 1.38 1.70
Story1 312241.03 1.79 2.34 307053.64 1.77 2.31

IRREGULARIDAD TORSIONAL EXTREMA

DIRECCIÓN X-X

Deriva máx Deriva Prom Relación


Story Combinación Dirección
m m
Story8 DRIFT Max X 0.014 0.009 1.485 CUMPLE
Story7 DRIFT Max X 0.015 0.010 1.479 CUMPLE
Story6 DRIFT Max X 0.015 0.010 1.480 CUMPLE
Story5 DRIFT Max X 0.015 0.010 1.481 CUMPLE
Story4 DRIFT Max X 0.015 0.010 1.482 CUMPLE
Story3 DRIFT Max X 0.013 0.009 1.478 CUMPLE
Story2 DRIFT Max X 0.010 0.007 1.461 CUMPLE
Story1 DRIFT Max X 0.005 0.004 1.388 CUMPLE

DIRECCIÓN Y-Y

Story Combinación Dirección Deriva máx Deriva Prom Relación

m m
Story8 DRIFT Max Y 0.010 0.009 1.027 CUMPLE
Story7 DRIFT Max Y 0.010 0.010 1.026 CUMPLE
Story6 DRIFT Max Y 0.011 0.011 1.025 CUMPLE
Story5 DRIFT Max Y 0.012 0.011 1.023 CUMPLE
Story4 DRIFT Max Y 0.011 0.011 1.022 CUMPLE
Story3 DRIFT Max Y 0.010 0.010 1.021 CUMPLE
Story2 DRIFT Max Y 0.008 0.008 1.019 CUMPLE
Story1 DRIFT Max Y 0.004 0.004 1.019 CUMPLE

IRREGULARIDAD TORSIONAL

DIRECCIÓN X-X
Deriva máx Desplaz. D.A. CM D.R. CM
Story Combinación Dirección
m Relativo m m
Story8 DRIFT Max X 0.0056 0.0137 0.0624 0.0059
Story7 DRIFT Max X 0.0059 0.0145 0.0566 0.0093
Story6 DRIFT Max X 0.0062 0.0152 0.0473 0.0097
Story5 DRIFT Max X 0.0062 0.0153 0.0375 0.0098
Story4 DRIFT Max X 0.0060 0.0146 0.0277 0.0094
Story3 DRIFT Max X 0.0053 0.0129 0.0183 0.0084
Story2 DRIFT Max X 0.0040 0.0098 0.0099 0.0064
Story1 DRIFT Max X 0.0020 0.0051 0.0035 0.0035

DIRECCIÓN Y-Y

Deriva máx Desplaz. D.A. CM D.R. CM


Story Combinación Dirección
m Relativo m m
Story8 DRIFT Max X 0.0039 0.0096 0.0730 0.0090
Story7 DRIFT Max X 0.0042 0.0104 0.0640 0.0098
Story6 DRIFT Max X 0.0046 0.0112 0.0542 0.0105
Story5 DRIFT Max X 0.0047 0.0116 0.0437 0.0110
Story4 DRIFT Max X 0.0047 0.0114 0.0327 0.0109
Story3 DRIFT Max X 0.0042 0.0104 0.0218 0.0099
Story2 DRIFT Max X 0.0033 0.0081 0.0118 0.0078
Story1 DRIFT Max X 0.0016 0.0042 0.0040 0.0040
MAX/CM

2.3380 NO CUMPLE
1.5608 NO CUMPLE
1.5583 NO CUMPLE
1.5555 NO CUMPLE
1.5516 NO CUMPLE
1.5441 NO CUMPLE
1.5243 NO CUMPLE
1.4606 NO CUMPLE

MAX/CM

1.0631 CUMPLE
1.0618 CUMPLE
1.0573 CUMPLE
1.0523 CUMPLE
1.0477 CUMPLE
1.0437 CUMPLE
1.0402 CUMPLE
1.0381 CUMPLE