Академический Документы
Профессиональный Документы
Культура Документы
5 Bypass dust removed from kiln 0.00 0.000 0.000 0.000 0.000 0.0000 0.0
6a Dust (main filter) returned via kiln feed 0.00 0.000 0.000 0.000 0.000 0.0000 0.0
7 Dust (main filter) removed from kiln 0.00 0.000 0.000 0.000 0.000 0.0000 0.0
8 Emission - - 0.000 - - - - - - 0.0000 - - -
TOTAL OUTPUT 0.000 0.000 0.000 0.000 0.0000 0.000 0.0
Input - output 0.000 0.000 0.000 0.000 0.000 0.00
Diff.
1. "Calculated" Cl in clinker*/**: n/a g/t cli < 200-300 for all kilns
* "Calculated" value in clinker = Total inputs minus dust output and emission, referred to clinker.
** "calculated" CL value shows more reliable values than the real value in clinker (which is heavily depending
on the current circulation situation)
*** "Relevant Input= All Cl inputs minus Cl in dust reused (via kiln feed or returned directly) in the kiln process minus emission
Limiting criteria HGRS: Maximum possible Cl input when maximising Cl valves
Note: The Chlorine limit of 5000 g/t clinker for wet/long dry kilns is from the process point of view only.
If all dust goes to the cement, the chlorine limit is usually around 1000 gr/t clinker.
2.000
1.800
1.600
% Cl
1.400
1.200
1.000
0.800
0.600
0.400
0.200
0.000
0.000 0.500 1.000 1.500 2.000 2.500 3.000 3.500 4.000 4.500 5.000 5.500 6.000
% SO3