Вы находитесь на странице: 1из 1

Data sheet

11.10.2018

Three-phase motors with squirrel cage rotor, inverter feeding


inverter output voltage up to 500 V
Type IE3-WU1F 315 MX4 FBW B IGR PT HB NS LL IL HW
Mains supply
Duty type S1
Design output ( kW ) 160
Design torque ( Nm ) 1025
Design current (A) 229.6
Class IE (-) IE3-95,8%
Efficiency determination ( - ) EN 60034-2-1
Design frequency ( Hz ) 50
Design speed [rpm] 1490
Design voltage (V) 500
Connection (-) Y
Power factor (-) 0,84
Efficiency100/75/50 % (%) 95,8 / 95,5 / 95
Th. cl. 155(F)

inverter output voltage up to 500 V acc. to IEC TS 60034-25:2014 (pic. 40, curve A) û<1,8kV / du/dt<5,0kV/µs
Inverter input 50 Hz
Duty type S9
Design output ( kW ) 160
Design torque ( Nm ) 1025
Design current (A) 229.6
Max. torque (50Hz) ( Nm ) 2296
Max. current (A) 565.6
Coolant temperature ( °C ) -20°C...+40°C
Altitude above sea level (m) 1000m
Degree of protection IP IP55
Moment of inertia ( kgm2 ) 4,01
Motor weight ( kg ) 1153
Bearing, D-side 6320 C3
Bearing, N-side 6317 MC3 VL0241
Relubrication interval (h) 4000
Grease type ASONIC GHY 72
Grease amount (g) 78/57
Forced-ventilation FBW 315 ILI
Output (W) 505
Voltage ( V )200-400 / 346-525 D/Y
Current (at 400V) (A) 1,95 /0,83

Options
Type of mounting IM B3
Flange: -
Terminal box Standard
Position of terminal box on the top
Cable gland Sealing plug
Position of cable entry right
Shaft Standard, 1 shaft end
Bearing Relubrication device, easy bearing arrangement
Special details to bearings Fixed bearing, N-side
Insulated bearing, N-side
Winding protection 3xPt 100 (2 wire connection, special isolation)
Anti-condensation heating 230V
Dredger version
Limit values to vibration velocity Class A
Balancing with half key

Colour system 02 world wide (KK C2-C3),RAL 7031 blue-grey


Speed sensor HOG 10
Type of external ventilator IC416 unit of WISTRO

Delivery conditions and/or official regulations: IEC / EN 60034-1