Вы находитесь на странице: 1из 2

MATERIALS: Earth, submerged soil 11.

0 KN/m3

Concrete, reinforced stone, including gravel 24 KN/m3

Steel, cold-drawn 77.3 KN/m3

II. LIVE LOADS:


I. DEAD LOAD Exit Facilities 4.80 kPa

Roofing Hallway 4.80 kPa

Deck, metal, 20 gage 0.12 kP Restrooms (T&B’s) 2.40 kPa

Ceiling Office 2.4 kPa

Suspended steel channel system 0.10 kPa Computer Use 4.8 kPa

Floor Finish Auditoriums 4.8 kPa

Ceramic or quarry tile(20mm) 1.10 kPa Classrooms 1.9 kPa


On 25mm mortar bed
Storage 1.9 kPa
Exterior Wall 3.3 kPa
Libraries 2.9 kPa

Interior Wall 3.17 kPa Roof Live Load 0.70 kPa


III. WINDLOAD Nearest Fault Line West Valley Fault System

Zone 4 0.40
Location: Imus, Cavite
Near Source Factor, Na 1.2
Zone 2 (Mid Wind Zone)
Near Source Factor, Nv 1.6
Exposure Coefficient, Kz 1.07
Seismic Coefficient, Ca 0.48
Wind directionally factor, Kd 0.85
Seismic Coefficient, Cv 0.64
Topographic Factor, Kzt 1.0 (Flat Terrain)
R 8.0
Velocity Pressure Coefficient, Kz 0.85
Importance Factor 1.5
Wind Speed, V 200 kph
Type of Soil Rock Soil
Importance Factor, Iw 1.15

Exposure C

Velocity Pressure, qz 1.98 kPa

REFERENCE:

NATIONAL STRUCTURAL CODE OF THE PHILIPPINES 2010

IV. EARTHQUAKE LOAD