INSTALLATION mark your planned opening (as (saber) saw with a sharp coarse blade
1. Determine approximately where on you established position when on to cut shingles and roof boards at
your roof you will place your Power roof ) and relocate your position to one time. If you do not have a coarse
Ventilator. be centered between two rafters. blade, cut away shingles inside the
Drive a nail into the roof so that circle with utility knife before cutting
it can be easily found when you roof boards.
• At the highest point in your return to the roof. Before you return 6. Carefully remove roofing nails from
attic or air space. Best if to the roof, be sure that you have:
centered on roof length, and top row of shingles so that the
(a) string or compass, (b) drill and drill flashing of the ventilator will slide
less conspicuous if placed on bit, (c) keyhole or electric jig (saber)
side away from street. under top row.
saw with a sharp coarse blade, (d)
•
IMPORTANT: Keep the highest ventilator and base, (e) roofing nails
and hammer, and (f ) roofing cement
Slide ventilator carefully into place
with arrow pointing up, letting
part of the dome lower than
the ridge line to ensure that and applicator. thermostat hang down into opening.
the dome's edge is NOT above Fasten the aluminum base to roof
3. Using the nail driven from the inside boards with roofing nails. Keep heads
ridge line. (Typically, the center as center, scribe a 14” diameter circle
of the vent should be about 24 of nails under shingles wherever
using string or compass. Care should possible.
inches down from the ridge.) be taken not to make the hole too
•
Establish your position with large. 7. Finish the exterior mounting by
sealing all seams and nails with
accuracy (because you will 4. Drill a starting hole for sawing inside
want to duplicate it inside your roofing cement. Use cement
the scribed circle. also to fasten down loose edges
attic) by measuring down from
the ridge and over from the 5. Starting in the drilled hole, cut circular of shingles. Return to the attic.
roof edge. opening, following the scribed line. You now have to mount the
Use either keyhole or an electric jig thermostat and connect the wiring.
2. Working now from the inside, 20500_0717
Find us on Subscribe on
Facebook 1.800.643.5596 • Lomanco, Inc. • lomanco.com YouTube
LomanCool 2000
TM
MUST DO Steps
THREE
Texas Department of
Insurance “Windstorm” ®
CSA
Approved
1
to attic ventilation Approved
2
the total attic area and eliminate weather infiltration. freight prepaid. This warranty does not include replacement due to destructive storms or labor cost incurred in the removal
Install ONLY ONE TYPE of Exhaust Ventilation within a of any defective part/product or installation of the new part/product. Online registration of the product at www.lomanco.
common attic area. com within ten (10) days of the initial installation of the product is a condition precedent to warranty coverage. ANY IMPLIED
Exhaust Vents pull air from the easiest intake source. Vent types WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE ALSO LIMITED IN DURATION TO FIVE
cannot be mixed. The use of different types of exhaust vents could (5) YEARS. CONSEQUENTIAL DAMAGES TO PROPERTY RESULTING FROM A BREACH OF ANY WARRANTY MENTIONED HEREIN
make one of the vents act as intake for the other. Intake air must ARE EXPRESSLY EXCLUDED. Some states do not allow limitations on how long an implied warranty lasts or do not allow
come from intake vents located near the lower part of the attic exclusion or limitation of consequential damages, so the above limitation may not apply to you. The warranty gives you
space to properly ventilate the total attic area and eliminate specific legal rights and you may also have other rights which vary from state to state.
3
weather infiltration.
Install a BALANCED SYSTEM of Intake and Exhaust ONLINE WARRANTY REGISTRATION
Ventilation. Please fill out the online form at lomanco.com
to complete your warranty registration. If for
50% Intake Ventilation - Intake vents located near the lower part any reason you are unable to register your
of the attic area are required to balance out your ventilation system. product online please call 1.800.643.5596 and
50% Exhaust Ventilation - Use a Lomanco Ventilation Selector
guide, the calculators at lomanco.com, or the Lomanco Vent we will assist you. Purchase and install date
Selector App to determine the number of vents needed to properly information will be required.
ventilate an attic to meet the minimum code ventilation standard.
20500_0717