Академический Документы
Профессиональный Документы
Культура Документы
Why an uninterruptible power system ? What you need to know about uninterruptible power systems
The distribution of electrical energy is often subject to by human action cause incalculable harm every day in The various types of uninterruptible power systems can be divided into three distinct categories, according to their
interference, this can be short lived or for extended terms of the alteration or complete destruction of data- technology, the degree of protection offered and power rating.
periods, caused by both external and internal factors. bases and damage to sensitive electronic equipment.
Offline Line Interactive Online
Atmospheric phenomena or phenomena determined with AVR dual conversion
Standard IEC62040-3 VFD-SY-311 VI-SS-311 VFI-SS-111
Level of protection High Total Excellent
Normal supply From mains power From mains power From UPS
The main phenomena and their causes Emergency supply
Voltage regulation
With switching < 10 ms
No
With switching
Yes
Without switching
Yes
Frequency regulation No No Yes
> Blackout > Electrical impurities
Power ratings used Low power Recommended up to 3 kVA Medium and high power
Causes Advantages Low cost Voltage stabilisation High protection
Reduced maintenance Better use of the batteries Many options available
• Storms • Current and voltage peaks Suitable for small power ratings Sinusoidal output* Extended back-up time
• Accidental causes • Interference * certain models.
• Short circuit • Voltage variations
• Industrial loads • Microinterruptions
• Overload • Frequency variations Choosing the right one
• Current harmonics
• Voltage distortion )
ne
(3
alo
E CH
s
m
IS
nd
IT
ste
Irregular phenomenon Irregular phenomenon PR S
sta
X
sy
R D W
M
S S
M
S )
IP )
-S (4)
• Loss of data TE LY LY RY YS YS YS
(1 (2
IT
• Alteration of data YS S-EN S D
U
D
U TE PH PH PH RY
S
RY
S
SY
S
YS
&
T S L L L A A A
• Disk crash • Operating faults N
e UP ITY MO MO MA DE DE DE SH SH PH LTM ATR
• Hardware damage • Premature wear of electronic parts Private user •
• Interruption of operations • Irreparable damage to electronic components Offices and shops • • • •
• Excessive current consumption. Small and medium enterprises • • • • • •
Corporate networks and telephony • • • •
Rack 19” IT Networking • • •
Data centres • • • • • • • •
Telecom • • • • • • • • • •
Security (emergency lighting) • • • • • •
Processes and infrastructure • • • • • • • • •
(1) Rectifier-chargers - (2) DC-AC inverters - (3) Static Transfer System - (4) Harmonic compensator.
2 3
NeTYS range PREMIUM
UPS-ENTERPRISE range PREMIUM
ADVANTAGE ADVANTAGE
PE 400-600-800-1000 VA > MORE SERVICES 800 VA > MORE SERVICES
PR 1000-1500-2000-3000 VA 1500 VA
2000 VA
> Level of protection > Why choose it > Level of protection > Why choose it
High, for PL models This is the ideal uninterruptible power system, with the Excellent, the highest performance for protection and UPS-ENTERPRISE is the range most suited for integra-
Total, for the PE and PR ranges best price / performance ratio for those looking for reliability. tion in professional environments with high protection
adequate protection for basic computer equipment requirements, which requires installation flexibility and
> Distinctive features and for networking (PR model). > Distinctive features optimal control of the operating functions.
Simplified installation and easy to use. Full and intuitive Digital architecture providing precision and compact
communication panel for the various functions. size. Great flexibility of installation for the 1500 and
2000 VA models, which can be floor-mounted or in a
19” rack cabinet.
PE PL PR
Simplified battery maintenance (user replaceable) • • 800 1000 1500 2000
Application connection with Schuko/IT/FR/BS plugs • Application connection with IEC 320 plugs (computer standard) • • • •
Application connection with IEC 320 plugs (computer standard) • • Advanced RS232/USB connection • • • •
Protection of the telephone or data line • • • Software for local/network shutdown or Web/SNMP manager adaptor • • • •
Advanced RS232 and/or USB connection (except PE 400 VA and PR 1000 VA ) • • • Automatic by-pass • • • •
Mounted on 19” rack • Automatic battery test • • • •
Software for local shutdown • • • External battery cabinet for extension of back-up time • • • •
Remote shutdown software and Web/SNMP manager adaptor • Simplified battery maintenance (hot swap) • •
Extension of back-up time • Mounted on 19” rack • • •
Dimension details on page 10. Dimension details on page 10.
4 5
ITYS range PREMIUM
MODULYS range PREMIUM
ADVANTAGE ADVANTAGE
1000 VA > MORE SERVICES SA stand alone > MORE SERVICES
> Level of protection > Why choose it > Level of protection > Why choose it
Excellent, the highest performance for protection ITYS is the essential UPS, it is both compact and Excellent, the highest performance for protection and This range stands out for its great flexibility to adapt to
and reliability thanks to the double conversion robust, and has all the features needed to provide reliability. future protection requirements. The plug-in modular
technology (VFI). single and centralized protection system is ideally suited for simple and effective
> Distinctive features management of the uninterruptible power system.
> Distinctive features Migration Concept. Innovative functionality that allows the
Simplified installation and easy to use. Full and intui- Stand Alone Tower / Rack model to be integrated and
tive communication panel for the various functions. connected in parallel in a system cabinet for future
Integrated manual by pass for 6-10 kVA. system expansion.
SA RM MC EB TC
Modular, scalable and redundant • • • •
1000 2000 3000 6000 10000 Migration Concept •
Advanced RS232 connection • • • • • Mounted on 19” rack • •
Application connection with IEC 320 plugs (computer standard) • • • Application connection via terminals (3 kVA SA IEC 320 16 A plug) • • • • •
Application connection via terminals • • • External battery cabinet for extension of back-up time • • • • •
EPO (Emergency Power Off) external remote button • • • • • Input/output galvanic isolation transformer option
Software for local/network shutdown or Web/SNMP manager adaptor • • • • • Software for local/network shutdown or Web/SNMP manager adaptor • • • • •
Dimension details on page 10. Dimension details on page 10.
6 7
MASTERYS SOFTWARE Range
range
BC stand alone
8-10-12-15-20 kVA
MC stand alone
10-15-20-30-40-60-80 kVA
IP stand alone with isolation
transformer 15-20-30-40 kVA
EB modular 30 and 60 kVA
> Level of protection with generator sets - Energy Saver ; energy saving > UNI VISION > NET VISION
Excellent, the highest performance for protection and in parallel configuration. Advanced software available free of charge on the Network interface for advanced applications.
reliability. website www.socomec.com.
> Why choose it
> Distinctive features The numerous options available mean that the UPS is > UNI VISION PRO > TOP VISION
Always-ON Mode ; energy saving - EBS ; battery easily adapted to any system requirement. Professional software for business applications. Management and supervision of the power supply.
pack management - GSS ; integration of the UPS
UNI VISION UNI VISION PRO NET VISION TOP VISION
Connection via RS232 serial port • • •
BC MC EB IP Connection via RS485 serial port •
Modular, scalable and redundant • Connection 10/100 Mbps Fast Ethernet RJ45 •
Three-phase or single-phase (Combi Concept) • Compatible with Windows™, Linux • • • •(1)
Sinusoidal absorption • • • Compatible with main O.S. like AIX,Solaris,HP-UX • •
Parallelable up to 2 units • Compatible with SNMP standard protocol •
Parallelable up to 6 units • • Automatic shutdown of the local workstation or server • •
Integrated LAN connection • • • Automatic shutdown of clients: networked Server/PC • •
Software for local/network shutdown or Web/SNMP manager adaptor • • • • Simplified graphic display (Web browser HTTP) • • •
Redundant batteries • • • History Log of electric measurements, alarms and events • • • •
Input/output galvanic isolation transformer option option • Notification of events to customized e-mail addresses • • •
Dimension details on page 10. (1) Windows™ only.
8 9
SOCOMEC UPS also manufactures
DELPHYS range > UPS
from 20 to 800 kVA
• Maximum power density on a minimum footprint
• Innovative solutions to eliminate harmonics and
rephase the input
• This system adapts to all applications thanks to its
electrical properties (very high short circuit currents)
and the wide availability of options
Réf. DOC 48033 - 07/07 - Photo : Martin Bernhart - Réalisation : SOCOMEC Service Communication - Imprimeur
Tel. +44 (0)1285 644444 TH - 10210 Bangkok
POLAND
Fax +44 (0)1285 644414 Tel. +66 2 503 92 43
Nowowiejska St 21/25
uk.ups.sales@socomec.com Fax +66 2 503 99 23
00-665 Warszawa
inquiry@socomec-unitrio.co.th
Tel. +48 (0)22 2345 223
Fax +48 (0)22 2345 223
ups.poland@socomec.com
www.socomec.com
This document is not a specification. SOCOMEC UPS reserves the right to make any changes to data without prior notice.