Вы находитесь на странице: 1из 1

NOTES:-

1 : REFER STAIR DRG. ALONG WITH THIS DRG.


2 : REFER DET OF BL / BLR / BLC IN STAIR DRG.
3 : REFER GENERAL NOTES DRG.
A B C D E F G 4 : PROVIDE CAMBER OF 20mm-25mm FOR
CANTILEVER SLAB/BEAM WITH SPAN
LESS THAN 6 FEET.
5 : PROVIDE CAMBER OF 30mm-40mm FOR
CANTILEVER SLAB/BEAM MORE THAN 6 FEET.
6 : PROVIDE THROUGHOUT RCC LINTEL & SILL
OVER ALL WALLS.
7 : CHECK THE STRUCTURAL DRG. WITH ARCH.
B1 DRG / ELEVATION / SECTION / 3D.
8 : IF ANY AMBIGUITY FOUND ,

B20
CONTACT STRUCTURE ENGG.

B26
IMMEDIATELY BEFORE STARTING WORK.
B2 S2 S2 9 : FOLLOW ONLY ARCHITECTURAL DIMENSIONS.

5 10 : STRUCTURE ENGINEER IS NOT RESPONSIBLE

B22
C10 C11 B3 C12 C13
IF ANY ACCIDENT OCCURS ON SITE
DUE TO CONSTRUCTION FAULTS.
11 : CHECK THE POSITION OF FC WITH

S1 S2
ARCH. DRG
B4 12 : GET IT APPROVED BY ARCHITECT BEFORE
STARTING EXECUTION OF WORK.
13 : REFER THE DRAWING WITH FOOTING
B15

B18
DRAWING FOR DIMENSIONS.

S1

B25
B5 B6 B19
4
C8 C9

S2 B7 B8
3
C6 C7
B14

B16

S1 S2

B24
207

B9 B10 B11 B12


2 CONCRETE GRADE

C3 C4 C5 ITEM GRADE
S2
450

8T-6"C/C
Q
COLUMN M20

S1 450
8T-6"C/C
Q FOOTING
SLAB
M20
M20
BEAM M20
450 USE STEEL GRADE Fe 500-D
8T-6"C/C
B17

B21

B23
Q

8T-8"C/C

8T-8"C/C
Q
Q

B13
450

1
C1 C2

125 MM THICK RCC SLAB

DRAWING TITLE:

FLOOR SLAB

FIRST FLOOR LEVEL SLAB LAYOUT DRG N0 : 01

SCALE: N.T.S. SHEET: A3