Академический Документы
Профессиональный Документы
Культура Документы
NONE
1 7 Improvements
Content 1) Improvement of check process of microcode update
This microcode does not execute the microcode update process for the second controller, if the
microcode has detected an incomplete microcode update for the first controller. Storage Navigator
Modular displays the new error message.
2) Improvement of SENC block process
Microcode does not collect unnecessary SENC log to switch over backend path quickly, when code
detects SENC failure which causes time-out error of SATA HDD and executes SENC block.
3) Improvement of the detection of the SENC failure
Code blocks the SENC which has detected the SATA disk failure for two or more SATA HDD at the
same time, because it seems very possible that the SENC failure causes this failure condition.
When an SENC had detected the SATA disk failure for two or more SATA HDD, previous
microcode blocks all of the SATA HDD.
4) Improvement of the SENC firmware error recovery
Code resets SENC and tries to recover SENC, when SENC firmware hung and SENC block
5) Improvement of the subsystem boot-up process
Subsystem can now boot up when the AL_PA error of a HDD has occurred, because this microcode
blocks the HDD of the AL_PA error in the power-on sequence of subsystem
6) New parameter under MENU “Others” in maintenance mode
“Subsystem boots up after HDD is removed during subsystem power-off” Subsystem can boot up
after the failed HDD has been removed offline, if above parameter has been set to “Enable” (default:
“Disable (normal boot-up)”), when the subsystem cannot boot up due to the HDD failure.
4 An HDD blockade may occur over and over again in the same HDD
Phenomena HDD blockade with WEB information message"I6DY00 Drive Response Diag NG".
This HDD blockade occurs again in the same HDD with the same WEB information
message after the HDD replacement.
Severity Medium
Conditions of Occurrence When all of the following conditions are met, the phenomenon may occur.
(a) Dual controller
(b) RAID5 which is composed of a few HDD (For example, 2D+1P of RAID5)
(There are a few HDD between which the Drive Response Diag function compares the
response performance.)
(c) LU of LU ownership of controller#0 and the LU of LU ownership of controller#1
are created in the RAID group of (b). (Both controllers access the each HDD of (b).)
(d) High-load sequential I/O issued to HDD from the controller, and low-load random
I/Os continues to be issued to the same HDD from the other controller.
(For example, the high-load sequential I/Os is "re-sync of Shadow Image".)
(e) The I/O loads of (4) continue more than 10 minutes.
Cause Microcode bug in detection process of failed HDD in Drive Response Diagnostic
Affected Products/Version Version : All microcode version
Fixed Product/Version Version : 0783/D
Category Drive Response Diag function
Changed Part MICRO-Disk
HDS Confidential 2 of 3
HDS Confidential 3 of 3