Вы находитесь на странице: 1из 3

Present O/p Current requirement as per PCP Current requirement as per IS Remarks

current (A) design (A) 8062 (A)


O/p Current At RRS TRU (A) 0.9 1.3320681876 0.6358579656 well within design current requirem
O/p Current At SV 33 CPPSM (A) 1.2 5.5068644473 2.4033802657 (Current requiremnt from Rewari t
O/p Current At BRS TRU (A) 0.9 2.3940148579 0.980473225 33 is 0.45 A)

Calculations

As per PCP design As per IS 8062


TotalCurrent
TOTAL SOIL CURRENT CURRENT TotalCurrent
TOTAL LENGTH SURFACE REQUIREMENT requirement REQUIREMENT
SECTION SURFACE RESISTIVITY requirement for
LENGTH (m) AREA (m2) (m) AREA (m2) for the section
(Ohm m) (A) (A) the section (A)
(A)

more than 100


ohm m 12.245 17590.2168 0.8003548639 0.3430092274
BRS to SV 34 19.072 24353.20463 2.3940148579 0.980473225
less than 10
ohm m 6.827 9807.13842 1.593659994 0.6374639976
less than 10
ohm m 13.703 19684.6664 3.1987582977 1.2795033191
SV 34 to 33 23.842 30444.05961 4.1747962597 1.7675223001
10 ohm m to
100 ohm m 10.453 15015.9686 0.9760379621 0.488018981
more than 100
ohm m 9.267 13312.2531 0.6057075152 0.2595889351
RRS to SV 33 30.158 38509.01559 less than 10 2.6641363752 1.2717159311
ohm m 0.732 1051.5344 0.1708743395 0.0683497358
10 ohm m to
100 ohm m 20.215 29039.3003 1.8875545205 0.9437772603

Current Density for different soil resistivity

As per PCP design As per IS 8062:2006


Currernt Currernt Density
Density (microA/m2)
Pipiline surroundings (microA/m2) Pipiline surroundings
Soil resistivity 10 ohm m to 100 ohm m 50 Soil resistivity 10 ohm m to 100 ohm m 25
Soil resistivity less than 10 ohm m 125 Soil resistivity less than 10 ohm m 50
Soil resistivity more than 100 ohm m 35 Soil resistivity more than 100 ohm m 15
Remarks

thin design current requirement


nt requiremnt from Rewari to SV-
33 is 0.45 A)