Present O/p Current requirement as per PCP Current requirement as per IS Remarks
current (A) design (A) 8062 (A)
O/p Current At RRS TRU (A) 0.9 1.3320681876 0.6358579656 well within design current requirem O/p Current At SV 33 CPPSM (A) 1.2 5.5068644473 2.4033802657 (Current requiremnt from Rewari t O/p Current At BRS TRU (A) 0.9 2.3940148579 0.980473225 33 is 0.45 A)
Calculations
As per PCP design As per IS 8062
TotalCurrent TOTAL SOIL CURRENT CURRENT TotalCurrent TOTAL LENGTH SURFACE REQUIREMENT requirement REQUIREMENT SECTION SURFACE RESISTIVITY requirement for LENGTH (m) AREA (m2) (m) AREA (m2) for the section (Ohm m) (A) (A) the section (A) (A)
more than 100
ohm m 12.245 17590.2168 0.8003548639 0.3430092274 BRS to SV 34 19.072 24353.20463 2.3940148579 0.980473225 less than 10 ohm m 6.827 9807.13842 1.593659994 0.6374639976 less than 10 ohm m 13.703 19684.6664 3.1987582977 1.2795033191 SV 34 to 33 23.842 30444.05961 4.1747962597 1.7675223001 10 ohm m to 100 ohm m 10.453 15015.9686 0.9760379621 0.488018981 more than 100 ohm m 9.267 13312.2531 0.6057075152 0.2595889351 RRS to SV 33 30.158 38509.01559 less than 10 2.6641363752 1.2717159311 ohm m 0.732 1051.5344 0.1708743395 0.0683497358 10 ohm m to 100 ohm m 20.215 29039.3003 1.8875545205 0.9437772603
Current Density for different soil resistivity
As per PCP design As per IS 8062:2006
Currernt Currernt Density Density (microA/m2) Pipiline surroundings (microA/m2) Pipiline surroundings Soil resistivity 10 ohm m to 100 ohm m 50 Soil resistivity 10 ohm m to 100 ohm m 25 Soil resistivity less than 10 ohm m 125 Soil resistivity less than 10 ohm m 50 Soil resistivity more than 100 ohm m 35 Soil resistivity more than 100 ohm m 15 Remarks