DCR-PC103E/PC104E/

PC105/PC105E
RMT-830/RMT-831

Ver 1.0 2003. 04 SECTION 6 ADJ


Revision History ADJUSTMENTS

Link
Before starting adjustment VIDEO SECTION ADJUSTMENT
Adjusting items when replacing main parts and boards PREPARATIONS BEFORE ADJUSTMENTS

SYSTEM CONTROL SYSTEM ADJUSTMENT


CAMERA SECTION ADJUSTMENT
SERVO AND RF SYSTEM ADJUSTMENT
PREPARATIONS BEFORE ADJUSTMENT
VIDEO SYSTEM ADJUSTMENTS
INITIALIZATION OF 8, A, B, C, D, E, F, 18, 1B, 1C, 1E, 1F PAGE DATA
AUDIO SYSTEM ADJUSTMENTS
CAMERA SYSTEM ADJUSTMENTS

COLOR ELECTRONIC VIEWFINDER SYSTEM ADJUSTMENT SERVICE MODE


LCD SYSTEM ADJUSTMENT ADJUSTMENT REMOTE COMMANDER

DATA PROCESS
MECHANISM SECTION ADJUSTMENT
SERVICE MODE
HOW TO ENTER RECORD MODE WITHOUT CASSETTE

HOW TO ENTER PLAYBACK MODE WITHOUT CASSETTE

TAPE PATH ADJUSTMENT

Contents of LEVEL 2 and LEVEL 3 Service Manual


CONTENTS LEVEL 2 LEVEL 3
1. SERVICE NOTE a ✕
2. DISASSEMBLY a ✕
3. BLOCK DIAGRAMS OVERALL ✕
POWER
4. PRINTED WIRING BOARDS AND CD-444, PD-193, LI-070, VC-319 BOARD
SCHEMATIC DIAGRAMS BJ-004, ST-084, FL4000,
VF-156, NS-018,
CONTROL SWITCH BLOCK
(FK4400, PS4400),
FP-467, FP-468, FP-228,
FP-672, FP-697 FLEXIBLE
5. REPAIR PARTS LIST EXPLODED VIEWS ✕
ELECTRICAL PARTS a (VC-319 BOARD)

2003D1600-1
©2003.4
9-876-258-51 Sony EMCS Co. Published by DI Customer Center
DCR-PC103E/PC104E/PC105/PC105E

TABLE OF CONTENTS
6. ADJUSTMENT 1. VCO Adjustment (VC-319 board) ································ 6-37
1. Before starting adjustment ··············································· 6-1 1-1. Manual Adjustment ······················································· 6-37
1-1. Adjusting items when replacing main parts and boards. ··· 6-2 1-2. Automatic Adjustment ··················································· 6-38
6-1. CAMERA SECTION ADJUSTMENT ··························· 6-4 2. RGB AMP Adjustment (VC-319 board) ······················· 6-39
1-1. PREPARATIONS BEFORE ADJUSTMENT 2-1. Automatic Adjustment ··················································· 6-39
(CAMERA SECTION) ··················································· 6-4 2-2. Manual Adjustment ······················································· 6-39
1-1-1. List of Service Tools ························································ 6-4 3. Contrast Adjustment (VC-319 board) ··························· 6-40
1-1-2. Preparations ····································································· 6-5 3-1. Automatic Adjustment ··················································· 6-40
1-1-3. Precaution ········································································ 6-7 3-2. Manual Adjustment ······················································· 6-40
1. Setting the Switch ···························································· 6-7 4. White Balance Adjustment (VC-319 board) ················· 6-41
2. Order of Adjustments ······················································ 6-7 1-5. LCD SYSTEM ADJUSTMENT ··································· 6-42
3. Subjects ··········································································· 6-7 1. LCD Automatic Adjustment (PD-193 board) ················ 6-42
4. Preparing the Flash Adjustment Box ······························· 6-8 2. V COM Adjustment (PD-193 board) ···························· 6-43
1-2. INITIALIZATION OF 8, A, B, C, D, E, F, 18, 1B, 1C, 1E, 3. White Balance Adjustment (PD-193 board) ·················· 6-43
1F PAGE DATA ······························································· 6-9 6-2. MECHANISM SECTION ADJUSTMENT ·················· 6-44
1-2-1. INITIALIZATION OF A, D PAGE DATA ···················· 6-10 2-1. HOW TO ENTER RECORD MODE WITHOUT
1. Initializing the A, D Page Data ······································ 6-10 CASSETTE ··································································· 6-44
2. Modification of A, D Page Data ···································· 6-10 2-2. HOW TO ENTER PLAYBACK MODE WITHOUT
3. A Page Table ·································································· 6-10 CASSETTE ··································································· 6-44
4. D Page Table ·································································· 6-11 2-3. TAPE PATH ADJUSTMENT ········································ 6-44
1-2-2. INITIALIZATION OF B, 1B PAGE DATA ·················· 6-12 1. Preparation for Adjustment ··········································· 6-44
1. Initializing the B, 1B Page Data ···································· 6-12 2. Processing after Completing Operations: ······················ 6-44
2. Modification of B, 1B Page Data ·································· 6-12 6-3. VIDEO SECTION ADJUSTMENT ······························ 6-45
3. B Page Table ·································································· 6-12 3-1. PREPARATIONS BEFORE ADJUSTMENTS ············ 6-45
4. 1B Page Table ································································ 6-12 3-1-1. Equipment to Required ·················································· 6-45
1-2-3. INITIALIZATION OF 8, C, 18, 1C PAGE DATA ········ 6-13 3-1-2. Precautions on Adjusting ··············································· 6-46
1. Initializing the 8, C, 18, 1C Page Data ·························· 6-13 3-1-3. Adjusting Connectors ···················································· 6-47
2. Modification of 8, C, 18, 1C Page Data ························ 6-13 3-1-4. Connecting the Equipment ············································ 6-47
3. 8 Page Table ··································································· 6-14 3-1-5. Alignment Tapes ···························································· 6-48
4. C Page Table ·································································· 6-15 3-1-6. Input/Output Level and Impedance ······························· 6-48
5. 18 Page Table ································································· 6-16 3-2. SYSTEM CONTROL SYSTEM ADJUSTMENT ········ 6-49
6. 1C Page Table ································································ 6-16 1. Initialization of 8, A, B, C, D, E, F, 18, 1B, 1C, 1E, 1F
1-2-4. INITIALIZATION OF E, F, 1E, 1F PAGE DATA ········ 6-17 Page Data ······································································· 6-49
1. Initializing the E, F, 1E, 1F Page Data ·························· 6-17 2. Touch Panel Adjustment ················································ 6-49
2. Modification of E, F, 1E, 1F Page Data ························· 6-17 3. Serial No. Input ····························································· 6-49
3. E Page Table ·································································· 6-18 3-1. Company ID Input ························································· 6-49
4. F Page Table ·································································· 6-19 3-2. Serial No. Input ····························································· 6-49
5. 1E Page Table ································································ 6-20 3-3. SERVO AND RF SYSTEM ADJUSTMENT ··············· 6-51
6. 1F Page Table ································································ 6-21 1. Cap FG Duty Adjustment (VC-319 Board) ··················· 6-51
1-3. CAMERA SYSTEM ADJUSTMENTS ························ 6-22 2. Switching Position Adjustment (VC-319 Board) ·········· 6-51
1. 54MHz:PAL/66MHz:NTSC Origin Oscillation Check 3. Error Rate Check ··························································· 6-52
(VC-319 board) ····························································· 6-22 3-1. Preparations before adjustments ···································· 6-52
2. Zoom Key Center Adjustment ······································· 6-22 3-2. Error Rate Check ··························································· 6-52
3. HALL Adjustment ························································· 6-23 3-3. Processing after Completing Adjustments ···················· 6-52
4. MR Adjustment ····························································· 6-24 3-4. VIDEO SYSTEM ADJUSTMENTS ····························· 6-53
5. Flange Back Adjustment (Using Minipattern Box) ······· 6-25 1. S VIDEO OUT Y Level Adjustment (VC-319 Board) ···· 6-53
6. Flange Back Adjustment (Using Flange Back Adjustment 2. S VIDEO OUT Chroma Level Adjustment
Chart and Subject More Than 500m Away) ·················· 6-26 (VC-319 Board) ····························································· 6-53
6-1. Flange Back Adjustment (1) ·········································· 6-26 3. VIDEO OUT Y, Chroma Level Check (VC-319 Board) ·· 6-54
6-2. Flange Back Adjustment (2) ·········································· 6-26 3-5. AUDIO SYSTEM ADJUSTMENTS ···························· 6-55
7. Flange Back Check ························································ 6-27 1. Playback Level Check ··················································· 6-56
8. MAX GAIN Adjustment ··············································· 6-27 2. Overall Level Characteristics Check ····························· 6-56
9. Picture Frame Setting (Color Reproduction Adjustment 3. Overall Distortion Check ··············································· 6-56
Frame) ··········································································· 6-28 4. Overall Noise Level Check ············································ 6-56
10. Color Reproduction Adjustment ···································· 6-29 5. Overall Separation Check ·············································· 6-56
11. LV Standard Data Input ················································· 6-30 6-4. SERVICE MODE ·························································· 6-57
12. Picture Frame Setting (All White Frame) ····················· 6-31 4-1. ADJUSTMENT REMOTE COMMANDER ················ 6-57
13. Auto White Balance Standard Data Input ····················· 6-32 1. Using the adjustment remote commander ····················· 6-57
14. Auto White Balance Adjustment ··································· 6-33 2. Precautions upon using the adjustment remote
15. White Balance Check ···················································· 6-34 commander ···································································· 6-57
16. Mechanical Shutter Adjustment ···································· 6-35 4-2. DATA PROCESS ··························································· 6-58
17. Steady Shot Check ························································· 6-35 4-3. SERVICE MODE ·························································· 6-59
18. Strobe Light Level Adjustment 1. Setting the Test Mode ···················································· 6-59
(DCR-PC105/PC105E) ················································· 6-36 2. Emergence Memory Address ········································ 6-59
19. Strobe White Balance Adjustment & Check 2-1. EMG Code (Emergency Code) ····································· 6-59
(DCR-PC105/PC105E) ················································· 6-36 2-2. MSW Code ···································································· 6-60
1-4. COLOR ELECTRONIC VIEWFINDER 3. Bit value discrimination ················································ 6-61
SYSTEM ADJUSTMENT ············································ 6-37 4. Switch check (1) ···························································· 6-61

—2—
DCR-PC103E/PC104E/PC105/PC105E

5. Switch check (2) ···························································· 6-61


6. Switch check (3) ···························································· 6-62
7. Switch check (4) ···························································· 6-62
8. LED check ····································································· 6-62
9. Record of Use check (1) ················································ 6-63
10. Record of Use check (2) ················································ 6-63
11. Record of Self-diagnosis check ····································· 6-64

* Color reproduction frame is shown on page 6-65.

—3—
DCR-PC103E/PC104E/PC105/PC105E

COVER SECTION 6
ADJUSTMENTS

1. Before starting adjustment

EVR Data Re-writing Procedure When Replacing Board


The data that is stored in the repair board, is not necessarily correct.
Perform either procedure 1 or procedure 2 or procedure 3 when replacing board.

Procedure 1
Save the EVR data of the machine in which a board is going to be replaced. Download the saved data after a board
is replaced.
(Machine before starting repair) (Machine after a board is replaced)
PC PC

Save the EVR data Download the saved


to a personal computer. data to a machine.

Procedure 2
Remove the EEPROM from the board of the machine that is going to be repaired. Install the removed EEPROM
to the replaced board.
Remove the EEPROM and install it.

(Former board) (New board)

Procedure 3
When the data cannot be saved due to defective EEPROM, or when the EEPROM cannot be removed or
installed, save the data from the same model of the same destination, and download it.
(Machine to be repaired) PC (Machine to be repaired)

Download the data.

Save the data.

(The same model of the same destination)

After the EVR data is saved and downloaded, check the


respective items of the EVR data.
(Refer to page 6-3 for the items to be checked.)

6-1
DCR-PC103E/PC104E/PC105/PC105E

COVER
1-1. Adjusting items when replacing main parts and boards.
• Adjusting items when replacing main parts
When replacing main parts, adjust the items indicated by z in the following table.
Note1: When replacing the drum assy. or the mechanism deck, reset the data of page: 7, address: A7 to A9 to “00”. (Refer to “Record of Use check” of
“6-4. SERVICE MODE”)
Replaced parts
Block replacement Parts replacement

PD-193 board IC600 (RGB driver, timing generator (LCD))

VC-319 board IC2301 (DV signal process,RF signal process)


VC-319 board IC2101 (Camera/DV signal process, etc.)
CD-444 board SE5201/5202 (YAW/PITCH sensor)

VC-319 board IC1501, X1501 (Timing generator)

VC-319 board IC4202 (Timing generator (EVF))


VC-319 board IC1901 (Video IN/OUT AMP)
VC-319 board IC4201 (RGB driver (EVF))
Mechanism deck M901 (Drum assy) Note1

VF-156 board D5602 (Backlight (EVF))


VC-319 board IC1801 (REC/PB AMP)
CD-444 board IC5101 (CCD imager)
Adjustment Adjustment

LCD block LCD901 (LCD panel)

EVF block LCD903 (LCD panel)

VC-319 board IC1503 (A/D conv.)


Section

Control switch block (FK-4400)

CD-444 board IC5102 (S/H)


Mechanism deck MD block
Flash unit (FL4400) Note2
Mechanism deck Note1

LCD block ND901


Lens device

Initialization of
Initialization of A, D page data
8, A, B, C, D, E,
Initialization of B, 1B page data
F, 18, 1B, 1C, 1E,
Initialization of 8, C, 18, 1C page data
1F page data Initialization of E, F, 1E, 1F page data
54MHz/66MHz origin oscillation check z
Zoom key center adj. z
HALL adj. z
MR adj. z
Flange back adj. z z
MAX GAIN adj. z z z
Color reproduction adj. z z z
Camera
LV standard data input z z z
AWB standard data input z z z
Auto white balance adj. z z z
Mechanical shutter adj. z
Steady shot check z
Strobe light level adjustment z
Strobe white balance adjustment & check z
VCO adj. zz
RGB AMP adj. z
Color EVF
Contrast adj. z z
White balance adj. z z z
LCD automatic adj. z z
LCD V COM adj. z
White balance adj. z z z
Mechanism Tape path adj. z z z
System control Touch panel adj. z
Serial No. input
CAP FG duty adj. z z
Servo, RF Switching position adj. z z z
Error rate check z z z z z
Video S VIDEO OUT Y level adj. z z
S VIDEO OUT chroma level adj. z z
Table. 6-1-1 (1).
6-2
DCR-PC103E/PC104E/PC105/PC105E

• Adjusting items when replacing a board or EEPROM


When replacing a board or EFPROM, adjust the items indicated by z in the following table.
Board EEPROM Note2: DCR-PC105/PC105E model only.
replacement replacement When the flash error code (E:91:**) is
displayed. After repair, clear the error flag.
(Refer to “Record of Self-diagnosis check”
of “6-4. SERVICE MODE”.)

IC2803 (Flash memory)


Adjustment Adjustment

IC2602 (EEPROM)
IC2701 (EEPROM)
Section

(COMPLEAT)
(COMPLEAT)
(COMPLEAT)
(COMPLEAT)
CD-444 board

VC-319 board

VC-319 board
VC-319 board
VC-319 board
PD-193 board

VF-156 board

Supporting
Initialization of
Initialization of A, D page data z z
8, A, B, C, D, E,
Initialization of B, 1B page data z z
F, 18, 1B, 1C, 1E,
Initialization of 8, C, 18, 1C page data z z
1F page data Initialization of E, F, 1E, 1F page data z z
54MHz/66MHz origin oscillation check z
Zoom key center adj. z z
HALL adj. z z z
MR adj. z z z
Flange back adj. z z z z
MAX GAIN adj. z z z z
Color reproduction adj. z z z
Camera
LV standard data input z z z z
AWB standard data input z z z z
Auto white balance adj. z z z z
Mechanical shutter adj. z z z
Steady shot check z z z z
Strobe light level adjustment z z z
Strobe white balance adjustment & check z z z
VCO adj. z z z
RGB AMP adj. z z z
Color EVF
Contrast adj. z z z
White balance adj. z z z
LCD automatic adj. z z z z
LCD V COM adj. z z z
White balance adj. z z z
Mechanism Tape path adj.
System control Touch panel adj. z z
Serial No. input z z
CAP FG duty adj. z z z
Servo, RF Switching position adj. z z z
Error rate check z z z
Video S VIDEO OUT Y level adj. z z
S VIDEO OUT chroma level adj. z z
Table. 6-1-1 (2).
6-3
DCR-PC103E/PC104E/PC105/PC105E

COVER

6-1. CAMERA SECTION ADJUSTMENT


1-1. PREPARATIONS BEFORE ADJUSTMENT (CAMERA SECTION)

1-1-1. List of Service Tools


• Oscilloscope • Color monitor • Vectorscope
• Regulated power supply • Digital voltmeter

Ref. No. Name Parts Code Usage


Auto white balance adjustment/check
J-1 Filter for color temperature correction (C14) J-6080-058-A
White balance adjustment/check
ND filter 1.0 J-6080-808-A White balance check
J-2 ND filter 0.4 J-6080-806-A White balance check
ND filter 0.1 J-6080-807-A White balance check
J-3 Pattern box PTB-450 J-6082-200-A
J-4 Color chart for pattern box J-6020-250-A
J-5 Adjustment remote commander(RM-95 upgraded) J-6082-053-B
J-6 Siemens star chart J-6080-875-A For checking the flange back
J-7 Clear chart for pattern box J-6080-621-A
J-8 CPC-6 flexible jig J-6082-370-C For adjusting the tape path
J-9 CPC-6 terminal board jig J-6082-371-A For adjusting the tape path
J-10 Mini pattern box J-6082-353-B For adjusting the flange back
J-11 Camera table J-6082-384-A For adjusting the flange back
J-12 Background paper J-2501-130-A For adjusting the flash unit

J-1 J-2 J-3 J-4 J-5

J-6 J-7 J-8 J-9 J-10

J-11 J-12

Fig. 6-1-1.

6-4
DCR-PC103E/PC104E/PC105/PC105E

1-1-2. Preparations
Pattern box
Note1: For details of how remove the cabinet and boards, refer to “2.
DISASSEMBLY”.
Note2: When performing only the adjustments, the lens block and boards
need not be disassembled.
Note3: Before performing the adjustments, check the data of page: 0,
address: 10 is “00”. If not, set data: 00 to this address.
1.5 m
1) Connect the equipment for adjustments according to Fig. 6-1-3.

Note4: As removing the control switch block (FK4400) (removing


CN1019 of the VC-319 board) means removing the lithium 3V
power supply (BT6401 on the LI-070 board), data such as date,
time, user-set menus will be lost. After completing adjustments,
reset these data.
But the self-diagnosis data and the data on history of use (total
drum rotation time etc.) will be kept even if the lithium 3V power
Front of the lens
supply is removed. (Refer to “6-4. Service Mode” for the self-
diagnosis data and the data on history of use.)

Note5: Setting the “Forced Camera Power ON” Mode


1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press the PAUSE
button.
The above procedure will enable the camera power to be turned Fig. 6-1-2.
on with the control switch block (PS4400) removed. After
completing adjustments, be sure to exit the “Forced Camera Power
ON Mode”.

Note6: Exiting the “Forced Camera Power ON” Mode


1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
button.
3) Select page: 0, address: 01, and set data: 00.

6-5
DCR-PC103E/PC104E/PC105/PC105E

[CONNECTION OF EQUIPMENT]

Adjustment remote
commander (RM-95) LANC jack

CPC-6 terminal board jig


(J-6082-371-A)

CPC-6 flexible jig


(J-6082-370-C)

Screw
AC power (M1.7 × 2.5),
AC IN adaptor lock ace, p2
DC-IN connector
CPC lid

Fig. 6-1-3.

6-6
DCR-PC103E/PC104E/PC105/PC105E

1-1-3. Precaution
1. Setting the Switch
Unless otherwise specified, set the switches as follows and perform adjustments without loading cassette.

1. POWER switch (PS4400 block) ............................ CAMERA CAMERA SET of the MENU settings (Page1)
2. NIGHT SHOT switch (Lens block) ................................. OFF DIGITAL ZOOM ..................................................... OFF
3. BACK LIGHT switch (BJ-004 board) ............................. OFF 16:9 WIDE ................................................................ OFF
4. FOCUS (FK4400 block) ....................................... MANUAL STEADY SHOT ....................................................... OFF
5. FUNCTION settings (Touch panel) SETUP MENU of the MENU settings (Page1)
SPOT METER (Page1) ............................................ AUTO DEMO MODE ......................................................... OFF
MANUAL SET of the MENU settings (Page1) EXPOSURE (Page2) ................................................ AUTO
PROGRAM AE .................................................... AUTO DIGITAL EFFECT (Page2) ......................................... OFF
PICTURE EFFECT .................................................. OFF COLOR SLOW S (Page3) ........................................... OFF
WHITE BALANCE ............................................. AUTO

2. Order of Adjustments
Basically carry out adjustments in the order given.

Color bar chart (Color reproduction adjustment frame )


Electronic beam scanning frame
H
Yellow

Magenta
White
Cyan
Green

C C=D D
Red
Blue

Magenta
Yellow

Green
White
Cyan

Blue
Red
CRT picture frame

V
A B A=B B A
Fig. b (TV monitor picture)
Fig. a Enlargement
(Video output terminal
output waveform)
Difference in level

Adjust the camera zoom and direction to


obtain the output waveform shown in Fig. a
B A and the TV monitor display shown in Fig. b.

Fig. 6-1-4.

3. Subjects
1) Color bar chart (Color reproduction adjustment frame)
When performing adjustments using the color bar chart, adjust
the picture frame as shown in Fig. 6-1-4. (Color reproduction White
adjustment frame)
841mm
2) Clear chart (Color reproduction adjustment frame)
Remove the color bar chart from the pattern box and insert a Black
clear chart in its place. (Do not perform zoom operations during
this time.)
3) Flange back adjustment chart 1189mm
Make the chart shown in Fig. 6-1-5 using A0 size (1189mm ×
841mm) black and white vellum paper. Fig. 6-1-5.

Note: Use matte vellum paper bigger than A0, and make sure the edges of
the black and white paper joined together are not rough.

6-7
DCR-PC103E/PC104E/PC105/PC105E

4. Preparing the Flash Adjustment Box


A dark room is required to provide an accurate strobe adjustment.
If it is not available, prepare the flash adjustment box as given below;

1) Provide woody board A, B and C of 15 mm thickness.

woody board A (2 sheets) woody board B (2 sheets) woody board C (1 sheet)

400 mm 370 mm 700 mm

513 mm 513 mm 700 mm

730 mm 700 mm

Fig. 6-1-6

2) Apply black mat paint to one side of woody board A and B.


3) Attach background paper (J-2501-130-A) to woody board C.
4) Assemble so that the black sides and the background paper side
of woody board A, B and C are internal. (Fig. 6-1-7)

woody board A

woody board B

woody board A

woody board B

woody board C

Fig. 6-1-7

6-8
DCR-PC103E/PC104E/PC105/PC105E

COVER

1-2. INITIALIZATION OF 8, A, B, C, D, E, F, 18, 1B,


1C, 1E, 1F PAGE DATA
Note: When reading or writing the 18, 1B, 1C, 1E or 1F page data, select
page: 0, address: 10, and set data: 01, then select 8, B, C, E or F
page. The 18, 1B, 1C, 1E or 1F page can be chosen by this data
setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.

[Connection of the power supply during the initialization of the [Initialization Procedure]
data.] 1. Initialization of A, D page data
1) Connect the regulated power supply and the digital voltmeter 2. Initialization of B, 1B page data
to the battery terminal as shown in Fig. 6-1-8. 3. Initialization of 8, C, 18, 1C page data
2) Adjust the output voltage of the regulated power supply so that 4. Initialization of E, F, 1E, 1F page data
the digital voltmeter display is 6.3 ± 0.1Vdc.
3) Turn off the power supply.
4) Turn on the HOLD switch of the adjusting remote commander.
5) Turn on the power supply.
6) Perform the initialization of the data.
Note: This is normal though the following message is indicated on the
LCD screen.
“FOR InfoLITHIUM BATTERY ONLY”

Digital volt meter

Battery terminal

Regulated power supply

Fig. 6-1-8.

6-9
DCR-PC103E/PC104E/PC105/PC105E

1-2-1. INITIALIZATION OF A, D PAGE DATA Processing after Completing Modification of A, D Page data
Order Page Address Data Procedure
Note: The data of page: 0, address: 10 must be “00”.
1 2 00 29 Set the data.
1. Initializing the A, D Page Data 2 2 01 29 Set the data, and press PAUSE
button.
Note1: If the A, D page data has been initialized, the following adjustments
need to be performed again. Note: If the following symptoms occur after completing of the
1) Modification of A, D page data “Modification of A, D page data”, check that the data of the “Fixed
2) Touch panel adjustment data-2” addresses of A and D page are same as those of the same
Note2: The power supply voltage must be 6.3 ± 0.1Vdc. model of the same destination.
Note3: NTSC model: DCR-PC105 1) The self-diagnosis code “E:20:00” on the LCD screen is displayed.
PAL model: DCR-PC103E/PC104E/PC105E 2) The power is shut off so that unit cannot operate.

Adjusting page A 3. A Page Table


Adjusting Address 10 to FF Note1: The data of page: 0, address: 10 must be “00”.
Adjusting page D Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the A, D
Adjusting Address 10 to 7F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, D
Page Data”).
Initializing Method:
Order Page Address Data Procedure
1 0 01 01 Set the data. Address Initial value Remark
2 0 10 00 Set the data. NTSC PAL
00 to 0F
3 7 03 Set the following data.
08 (NTSC) 10 to 17 Fixed data-1
88 (PAL) 18 Fixed data-2
4 7 00 Set the following data. 19 Fixed data-1
20 (Initializing A page) 1A Fixed data-2
22 (Initializing D page) 1B
28 (Initializing A and D pages) 1C to 23 Fixed data-1
5 7 01 Set the following data, and press 24 Fixed data-2
PAUSE button. 25 (Modified data. Copy the data
20 (Initializing A page)
26 built in the same model.)
22 (Initializing D page)
28 (Initializing A and D pages) 27 to 2E Fixed data-1
2F Fixed data-2
6 7 02 Check that the data changes to
“01” 30
7 Perform “Modification of A, D 31 Fixed data-1
Page Data”. 32 Fixed data-2
33 to 39 Fixed data-1
2. Modification of A, D Page Data 3A Fixed data-2
If the A, D page data has been initialized, change the data of the 3B (Modified data. Copy the data
“Fixed data-2” address shown in the following tables by manual
3C built in the same model.)
input.
3D
Modifying Method: 3E
1) Before changing the data, select page: 0, address: 01, and set 3F to 4F Fixed data-1
data: 01. 50 Fixed data-2
2) New data for changing are not shown in the tables because 51 (Modified data. Copy the data
they are different in destination. When changing the data, copy
52 built in the same model.)
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may 53 Fixed data-1
not operate. 54 Fixed data-2
3) When changing the data, press the PAUSE button of the 55 (Modified data. Copy the data
adjustment remote commander each time when setting new
56 built in the same model.)
data to write the data in the non-volatile memory.
57 to 59 Fixed data-1
5A Fixed data-2
5B
5C to 5E Fixed data-1
5F Fixed data-2
60 to 8F Fixed data-1

6-10
DCR-PC103E/PC104E/PC105/PC105E

A Page
4. D Page Table
Address Initial value Remark
Note1: The data of page: 0, address: 10 must be “00”.
NTSC PAL Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the A, D
90 CB CC Touch panel adj. Page Data”.)
91 20 1D Fixed data-2: Modified data. (Refer to “2. Modification of A, D
Page Data”).
92 CF C4
93 1C 28
Address Remark
94 to A3 Fixed data-1 Initial value
A4 Fixed data-2 00 to 0F
A5 10 00 Test mode
A6 to A9 Fixed data-1 11 Fixed data-1
AA Fixed data-2 12 Fixed data-2
AB to AE Fixed data-1 13
AF Fixed data-2 13 to 15 Fixed data-1
B0 to B6 Fixed data-1 16 Fixed data-2
B7 Fixed data-2 17 to 18 Fixed data-1
B8 to CF Fixed data-1 19 Fixed data-2
D0 Fixed data-2 1A to 22 Fixed data-1
D1 23 Fixed data-2
D2 to D3 Fixed data-1 24 (Modified data. Copy the data
D4 Fixed data-2 25 built in the same model.)
D5 to FF Fixed data-1 26
Table. 6-1-2. 27 to 29 Fixed data-1
2A Fixed data-2
2B
2C to 35 Fixed data-1
36 Fixed data-2
37 (Modified data. Copy the data
38 built in the same model.)
39 Fixed data-1
3A Fixed data-2
3B to 3C Fixed data-1
3D Fixed data-2
3E to 57 Fixed data-1
58 Fixed data-2
59 to 6E Fixed data-1
6F Fixed data-2
70 to 7F Fixed data-1
Table. 6-1-3.

6-11
DCR-PC103E/PC104E/PC105/PC105E

1-2-2. INITIALIZATION OF B, 1B PAGE DATA Processing after Completing Modification of B, 1B Page data:
Order Page Address Data Procedure
Note: When reading or writing the B page data, select page: 0, address:
10, and set data: 00. 1 0 10 00 Set the data.
When reading or writing the 1B page data, select page: 0, address: 2 2 00 29 Set the data.
10, and set data: 01, then select B page. The 1B page can be chosen
3 2 01 29 Set the data, and press PAUSE
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to button.
“00”.
3. B Page Table
1. Initializing the B, 1B Page Data
Note1: If “Initializing the B, 1B Page Data” is performed, all data of the Note1: The data of page: 0, address: 10 must be “00”.
B page and 1B page will be initialized. (It is impossible to initialize Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the B, 1B
a single page.) Page Data”.)
Note2: If the B, 1B page data has been initialized, the following Fixed data-2: Modified data. (Refer to “2. Modification of B, 1B
adjustments need to be performed again. Page Data”).
1) Modification of B, 1B page data
Note3: The power supply voltage must be 6.3 ± 0.1Vdc. Address Remark
00 to 02 Fixed data-1
Adjusting page B
03 Fixed data-2
Adjusting Address 00 to FF
04 to FF Fixed data-1
Adjusting page 1B
Table. 6-1-4.
Adjusting Address 00 to FF
4. 1B Page Table
Initializing Method: Note1: When reading or writing the 1B page data, select page: 0, address:
Order Page Address Data Procedure 10, and set data: 01, then select B page. The 1B page can be chosen
by this data setting.
1 0 01 01 Set the data.
After reading or writing, reset the data of page: 0, address: 10 to
2 0 10 00 Set the data. “00”.
3 5 02 FF Set the data, and press PAUSE Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the B, 1B
button. Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of B, 1B
4 5 01 F3 Set the data, and press PAUSE Page Data”).
button.
5 5 00 01 Set the data, and press PAUSE Address Remark
button.
00 Fixed data-2
6 5 02 Check that the data changes to
“00”. 01 to 24 Fixed data-1
7 Perform “Modification of B, 1B 25 Fixed data-2
Page Data”. 26 to FF Fixed data-1
Table. 6-1-5.
2. Modification of B, 1B Page Data
If the B, 1B page data has been initialized, change the data of the
“Fixed data-2” address shown in the following tables by manual
input.

Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) When changing the B page data, select page: 0, address: 10,
and set data: 00.
3) When changing the 1B page data, select page: 0, address: 10,
and set data: 01.
After completing the modification of 1B page data, reset the
data of this address to “00”.
4) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
5) When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.

6-12
DCR-PC103E/PC104E/PC105/PC105E

1-2-3. INITIALIZATION OF 8, C, 18, 1C PAGE DATA 2. Modification of 8, C, 18, 1C Page Data


Note: When reading or writing the 8, C page data, select page: 0, address: If the 8, C, 18, 1C page data has been initialized, change the data of
10, and set data: 00. the “Fixed data-2” address shown in the following table by manual
When reading or writing the 18, 1C page data, select page: 0, address: input.
10, and set data: 01, then select 8 or C page. The 18 or 1C page can
be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to Modifying Method:
“00”. 1) Before changing the data, select page: 0, address: 01, and set
data: 01.
1. Initializing the 8, C, 18, 1C Page Data 2) When changing the 8, C page data, select page: 0, address: 10,
Note1: If “Initializing the 8, C, 18, 1C Page Data” is performed, all data and set data: 00.
of the 8 page, C page, 18 page and 1C page will be initialized. (It 3) When changing the 18, 1C page data, select page: 0, address:
is impossible to initialize a single page.) 10, and set data: 01.
Note2: If the 8, C, 18, 1C page data has been initialized, following After completing the modification of 18, 1C page data, reset
adjustments need to be performed again. the data of this address to “00”.
1) Modification of 8, C, 18, 1C page data
4) New data for changing are not shown in the tables because
2) Viewfinder system adjustments
3) LCD system adjustments they are different in destination. When changing the data, copy
4) Serial No. input the data built in the same model.
5) Servo and RF system adjustments Note: If copy the data built in the different model, the camcorder may
6) Video system adjustments not operate.
Note3: The power supply voltage must be 6.3 ± 0.1Vdc. 5) When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
Adjusting page 8 data to write the data in the non-volatile memory.
6) Check that the data of adjustment addresses is the initial value.
Adjusting Address 00 to FF If not, change the data to the initial value.
Adjusting page C
Adjusting Address 10 to FF Processing after Completing Modification of 8, C, 18, 1C Page
Adjusting page 18 data
Adjusting Address 00 to FF Order Page Address Data Procedure
Adjusting page 1C 1 0 10 00 Set the data.
Adjusting Address 00 to FF 2 2 00 29 Set the data.
3 2 01 29 Set the data, and press PAUSE
Initializing Method: button.
Order Page Address Data Procedure
1 0 01 01 Set the data.
2 0 10 00 Set the data.
3 3 81 Check that the data is “00”.
4 3 80 0C Set the data, and press PAUSE
button.
5 3 80 Check that the data changes to
“1C”.
6 Perform “Modification of 8, C,
18, 1C Page Data”.

6-13
DCR-PC103E/PC104E/PC105/PC105E

3. 8 Page Table
Note1: The data of page: 0, address: 10 must be “00”. Address Remark
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
18, 1C Page Data”.) CE to D5 Fixed data-1
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C, D6 Fixed data-2
18, 1C Page Data”). D7
Address Remark D8 to D9 Fixed data-1
DA Fixed data-2
00 to 18 Fixed data-1 DB (Modified data. Copy the data
19 Fixed data-2 DC built in the same model.)
1A to 29 Fixed data-1 DD
2A Fixed data-2 DE
2B to 3F Fixed data-1 DF
40 Fixed data-2 E0
41 to 4E Fixed data-1 E1 Fixed data-1
4F Fixed data-2 E2 Fixed data-2
50 to 79 Fixed data-1 E3 (Modified data. Copy the data
7A Fixed data-2 E4 built in the same model.)
7B (Modified data. Copy the data E5
7C built in the same model.) E6
7D to 83 Fixed data-1 E7
84 Fixed data-2 E8
85 (Modified data. Copy the data E9 Fixed data-1
86 built in the same model.) EA Fixed data-2
87 EB (Modified data. Copy the data
88 EC built in the same model.)
89 ED
8A EE
8B EF
8C to 91 Fixed data-1 F0
92 Fixed data-2 F1
93 to 94 Fixed data-1 F2
95 Fixed data-2 F3 Fixed data-1
96 to AC Fixed data-1 F4 Fixed data-2
AD Fixed data-2 F5 to FF Fixed data-1
AE to B0 Fixed data-1
Table. 6-1-6.
B1 Fixed data-2
B2 to B5 Fixed data-1
B6 Fixed data-2
B7 Fixed data-1
B8 Fixed data-2
B9 Fixed data-1
BA Fixed data-2
BB
BC to BD Fixed data-1
BE Fixed data-2
BF to C2 Fixed data-1
C3 Fixed data-2
C4 (Modified data. Copy the data
C5 built in the same model.)
C6
C7 Fixed data-1
C8 Fixed data-2
C9 (Modified data. Copy the data
CA built in the same model.)
CB
CC
CD

6-14
DCR-PC103E/PC104E/PC105/PC105E

4. C Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Address Initial value Remark
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
18, 1C Page Data”.) NTSC PAL
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C, 5E to 60 Fixed data-1
18, 1C Page Data”). 61 Fixed data-2
62 (Modified data. Copy the data
Address Initial value Remark 63 built in the same model.)
NTSC PAL 64
00 to 0F 65
10 EE EE Switching position adj. 66
11 00 00 67
12 00 00 68
13 00 00 69
14 to 15 Fixed data-1 6A
16 E0 E0 CAP FG duty adj. 6B
17 to 24 Fixed data-1 6C
25 86 86 S VIDEO out Y level adj. 6D
26 7D 7D S VIDEO out Cr level adj. 6E to A3 Fixed data-1
27 59 59 S VIDEO out Cb level adj. A4 Fixed data-2
28 to 33 Fixed data-1 A5 to A6 Fixed data-1
34 Fixed data-2 A7 Fixed data-2
35 A8
36 58 70 VCO adj. (EVF) A9 to AC Fixed data-1
37 70 58 AD Fixed data-2
38 Fixed data-1 AE to AF Fixed data-1
39 97 97 RGB AMP adj. (EVF) B0 Fixed data-2
3A to 3B Fixed data-1 B1
3C 80 80 White balance adj. (EVF) B2 to C4 Fixed data-1
3D 80 80 C5 Fixed data-2
3E 37 37 Contrast adj. (EVF) C6 to CB Fixed data-1
3F Fixed data-1 CC Fixed data-2
40 Fixed data-2 CD (Modified data. Copy the data
41 to 44 Fixed data-1 CE built in the same model.)
45 Fixed data-2 CF
46 D0
47 6A 93 VCO adj. (LCD) D1
48 93 6A D2
49 A2 A2 V COM adj. (LCD) D3
4A 91 91 RGB AMP adj. (LCD) D4
4B Fixed data-2 D5
4C D6 to DC Fixed data-1
4D 80 80 White balance adj. (LCD) DD Fixed data-2
4E 80 80 DE Fixed data-1
4F 41 41 Contrast adj. (LCD) DF Fixed data-2
50 to 51 Fixed data-1 E0 08 08 Serial No. input
52 A4 A4 PSIG black adj. (LCD) E1 00 00
53 Fixed data-2 E2 46 46
54 (Modified data. Copy the data E3 01 01
55 built in the same model.) E4 02 02
56 E5 00 00
57 E6 00 00
58 E7 00 00
59 Fixed data-1 E8 to E9 Fixed data-1
5A Fixed data-2 EA Fixed data-2
5B EB to F3 Fixed data-1
5C Fixed data-1 F4 00 00 Emergency memory address
5D F5 00 00

6-15
DCR-PC103E/PC104E/PC105/PC105E

C Page
6. 1C Page Table
Note1: When reading or writing the 1C page data, select page: 0, address:
Address Initial value Remark
10, and set data: 01, then select C page. The 1C page can be chosen
NTSC PAL by this data setting.
F6 00 00 Emergency memory address After reading or writing, reset the data of page: 0, address: 10 to
F7 00 00 “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
F8 00 00 18, 1C Page Data”.)
F9 00 00 Fixed data-2: Modfied data. (Refer to “2. Modification of 8, C,
FA 00 00 18, 1C Page Data”).
FB 00 00
Address Remark
FC 00 00 Initial value
FD 00 00 00 to B2 Fixed data-1
FE 00 00 B3 00 Error rate check
FF 00 00 B4 00
Table. 6-1-7. B5 00
B6 00
5. 18 Page Table B7 00
B8 80
Note1: When reading or writing the 18 page data, select page: 0, address: B9 00
10, and set data: 01, then select 8 page. The 18 page can be chosen
by this data setting. BA 00
After reading or writing, reset the data of page: 0, address: 10 to BB 00
“00”. BC 00
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
18, 1C Page Data”.) BD 00
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C, BE 00
18, 1C Page Data”). BF 00
C0 00
Address Remark
C1 00
00 Fixed data-1 C2 00
01 Fixed data-2 C3 80
02 to FF Fixed data-1 C4 00
Table. 6-1-8. C5 00
C6 00
C7 00
C8 00
C9 to FF Fixed data-1
Table. 6-1-9.

6-16
DCR-PC103E/PC104E/PC105/PC105E

1-2-4. INITIALIZATION OF E, F, 1E, 1F PAGE DATA 2. Modification of E, F, 1E, 1F Page Data


Note: When reading or writing the E, F page data, select page: 0, address: If the E, F, 1E, 1F page data has been initialized, change the data of
10, and set data: 00. the “Fixed data-2” address shown in the following table by manual
When reading or writing the 1E, 1F page data, select page: 0, address: input.
10, and set data: 01, then select E or F page. The 1E or 1F page can
be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to Modifying Method:
“00”. 1) Before changing the data, select page: 0, address: 01, and set
data: 01.
1. Initializing the E, F, 1E, 1F Page Data 2) When changing the E, F page data, select page: 0, address: 10,
and set data: 00.
Note1: If “Initializing the E, F, 1E, 1F Page Data” is performed, all data 3) When changing the 1F page data, select page: 0, address: 10,
of the E page, F page, 1E page and 1F page will be initialized. (It and set data: 01.
is impossible to initialize a single page.) After completing the modification of 1F page data, reset the
Note2: If the E, F, 1E, 1F page data has been initialized, following data of this address to “00”.
adjustments need to be performed again. 4) New data for changing are not shown in the tables because
1) Modification of E, F, 1E, 1F page data
they are different in destination. When changing the data, copy
2) Camera system adjustments
Note3: The power supply voltage must be 6.3 ± 0.1Vdc. the data built in the same model.
Note4: NTSC model: DCR-PC105 Note: If copy the data built in the different model, the camcorder may
PAL model: DCR-PC103E/PC104E/PC105E not operate.
5) When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
Adjusting page E
data to write the data in the non-volatile memory.
Adjusting Address 00 to FF 6) Check that the data of adjustment addresses is the initial value.
Adjusting page F If not, change the data to the initial value.
Adjusting Address 10 to FF
Processing after Completing Modification of E, F, 1E, 1F Page
Adjusting page 1E
data
Adjusting Address 00 to FF Order Page Address Data Procedure
Adjusting page 1F
1 0 10 00 Set the data.
Adjusting Address 00 to FF 2 2 00 29 Set the data.
Initializing Method: 3 2 01 29 Set the data, and press PAUSE
button.
Order Page Address Data Procedure
1 0 01 01 Set the data.
2 0 10 00 Set the data.
3 6 01 Set the following data, and press
PAUSE button.
2D (NTSC), 2F (PAL)
4 6 03 01 Set the data, and press PAUSE
button.
5 6 02 Check that the data changes to
“01”.
6 Perform “Modification of E, F,
1E, 1F Page Data”.

6-17
DCR-PC103E/PC104E/PC105/PC105E

3. E Page Table
Address Remark
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
66 Fixed data-2
1E, 1F Page Data”.) 67 (Modified data. Copy the data
Fixed data-2: Modified data. (Refer to “2. Modification of E, F, 68 built in the same model.)
1E, 1F Page Data”).
69
Address Remark 6A to 6E Fixed data-1
6F Fixed data-2
00 to 07 Fixed data-1
70 (Modified data. Copy the data
08 Fixed data-2
71 built in the same model.)
09 (Modified data. Copy the data
72 to B1 Fixed data-1
0A built in the same model.)
B2 Fixed data-2
0B
B3 to BC Fixed data-1
0C
BD Fixed data-2
0D
BE to DD Fixed data-1
0E
DE Fixed data-2
0F Fixed data-1
DF to ED Fixed data-1
10 Fixed data-2
EE Fixed data-2
11 (Modified data. Copy the data
EF to F0 Fixed data-1
12 built in the same model.)
F1 Fixed data-2
13 to 15 Fixed data-1
F2 to F6 Fixed data-1
16 Fixed data-2
F7 Fixed data-2
17 to 18 Fixed data-1
F8 (Modified data. Copy the data
19 Fixed data-2
F9 built in the same model.)
1A Fixed data-1
FA to FB Fixed data-1
1B Fixed data-2
FC Fixed data-2
1C Fixed data-1
FD
1D Fixed data-2
FE to FF Fixed data-1
1E to 1F Fixed data-1
Table. 6-1-10.
20 Fixed data-2
21 (Modified data. Copy the data
22 built in the same model.)
23
24
25
26
27 to 2F Fixed data-1
30 Fixed data-2
31
32 to 37 Fixed data-1
38 Fixed data-2
39
3A to 3B Fixed data-1
3C Fixed data-2
3D
3E to 45 Fixed data-1
46 Fixed data-2
47
48 to 53 Fixed data-1
54 Fixed data-2
55
56 to 59 Fixed data-1
5A Fixed data-2
5B
5C to 65 Fixed data-1

6-18
DCR-PC103E/PC104E/PC105/PC105E

4. F Page Table
Address Initial value Remark
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, NTSC PAL
1E, 1F Page Data”.) 54 00 00 Flange back adj.
Fixed data-2: Modified data. (Refer to “2. Modification of E, F, 55 48 48
1E, 1F Page Data”).
56 00 00
57 00 00
Address Initial value Remark 58 00 00
NTSC PAL 59 Fixed data-1
00 to FF
5A 80 80 MR adj.
10 Fixed data-1
5B 80 80
11 80 80 Zoom key center adj.
5C 80 80
12 Fixed data-1
5D 80 80
13 40 40 HALL adj.
5E 40 40
14 70 70
5F C0 C0
15 88 88
60 40 40
16 40 40
61 C0 C0
17 80 80
62 40 40
18 88 88
63 C0 C0
19 A0 A0 MAX GAIN adj.
64 40 40
1A 59 59 LV standard data input
65 C0 C0
1B 9E 9E
66 to 71 Fixed data-1
1C to 2D Fixed data-1
72 Fixed data-2
2E 28 2B AWB standard data input
73
2F CF 26
74 to 75 Fixed data-1
30 07 08
76 40 40 Mechanical shutter adj.
31 E6 8A
77 00 00
32 19 1B Auto white balance adj.
78 34 34
33 DA 3C
79 00 00
34 0D 0E
7A 30 30
35 AD 6D
7B 00 00
36 Fixed data-1
7C 2A 2A
37 45 48 Color reproduction adj.
7D 00 00
38 Fixed data-1
7E 12 10
39 2C 2E Color reproduction adj.
7F 00 00
3A to 3D Fixed data-1
80 40 40
3E 2D 2D Strobe white balance adj.
81 3A 3A
3F 64 64 (DCR-PC105/PC105E)
82 31 31
40 FF FE Color reproduction adj.
83 31 31
41 E7 E1
84 35 35
42 to 44 Fixed data-1
85 1E 1E
45 Fixed data-2
86 80 80
46 Fixed data-1
87 80 80
47 Fixed data-2
88 80 80
48 3F 3F Flange back adj.
89 80 80
49 10 10
8A 80 80
4A 39 39
8B 80 80
4B C2 C2
8C 01 01 Strobe light level adj.
4C 1E 1E
8D E0 E0 (DCR-PC105/PC105E)
4D 2E 2E
8E 80 80
4E 00 00
8F 80 80
4F 00 00
90 80 80
50 00 00
91 20 20
51 00 00
92 19 19 HALL adj.
52 6E 6E
93 to 97 Fixed data-1
53 19 19
98 Fixed data-2

6-19
DCR-PC103E/PC104E/PC105/PC105E

5. 1E Page Table
Address Initial value Remark
Note1: When reading or writing the 1E page data, select page: 0, address:
NTSC PAL 10, and set data: 01, then select E page. The 1E page can be chosen
99 Fixed data-1 by this data setting.
9A Fixed data-2 After reading or writing, reset the data of page: 0, address: 10 to
“00”.
9B (Modified data. Copy the data
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
9C built in the same model.) 1E, 1F Page Data”.)
9D to A5 Fixed data-1 Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1E, 1F Page Data”).
A6 Fixed data-2
A7 to AA Fixed data-1
Address Remark
AB Fixed data-2
AC to F6 Fixed data-1 00 to 91 Fixed data-1
F7 Fixed data-2 92 Fixed data-2
F8 to F9 Fixed data-1 93 to 9D Fixed data-1
FA Fixed data-2 9E Fixed data-2
FB 9F to C8 Fixed data-1
FC to FF Fixed data-1 C9 Fixed data-2
Table. 6-1-11. CA (Modified data. Copy the data
CB built in the same model.)
CC
CD
CE
CF Fixed data-1
D0 Fixed data-2
D1 to D9 Fixed data-1
DA Fixed data-2
DB (Modified data. Copy the data
DC built in the same model.)
DE to FF Fixed data-1
Table. 6-1-12.

6-20
DCR-PC103E/PC104E/PC105/PC105E

6. 1F Page Table
Address Remark
Note1: When reading or writing the 1F page data, select page: 0, address:
10, and set data: 01, then select F page. The 1F page can be chosen
BC Fixed data-2
by this data setting. BD Fixed data-1
After reading or writing, reset the data of page: 0, address: 10 to BE Fixed data-2
“00”.
BF
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
1E, 1F Page Data”.) C0 to C9 Fixed data-1
Fixed data-2: Modified data. (Refer to “2. Modification of E, F, CA Fixed data-2
1E, 1F Page Data”).
CB (Modified data. Copy the data
CC built in the same model.)
Address Remark
CD to FF Fixed data-1
00 Fixed data-2
Table. 6-1-13.
01 to 47 Fixed data-1
48 Fixed data-2
49 to 5B Fixed data-1
5C Fixed data-2
5D to 67 Fixed data-1
68 Fixed data-2
69 to 6F Fixed data-1
70 Fixed data-2
71
72 to 7A Fixed data-1
7B Fixed data-2
7C to 86 Fixed data-1
88 Fixed data-2
89 Fixed data-1
8A Fixed data-2
8B (Modified data. Copy the data
8C built in the same model.)
8D
8E
8F
90
91 to 93 Fixed data-1
94 Fixed data-2
95 (Modified data. Copy the data
96 built in the same model.)
97 to 9B Fixed data-1
9C Fixed data-2
9D to 9E Fixed data-1
9F Fixed data-2
A0 to AB Fixed data-1
AC Fixed data-2
AD
AE Fixed data-1
AF Fixed data-2
B0 (Modified data. Copy the data
B1 built in the same model.)
B2
B3 Fixed data-1
B4 Fixed data-2
B5 to B7 Fixed data-1
B8 Fixed data-2
B9 (Modified data. Copy the data
BA built in the same model.)
BB Fixed data-1

6-21
DCR-PC103E/PC104E/PC105/PC105E

COVER

1-3. CAMERA SYSTEM ADJUSTMENTS 2. Zoom Key Center Adjustment


Set the A/D value center of the microprocessor to the center voltage
Before perform the camera system adjustments (except for “54MHz/ of the zoom key.
66MHz Origin Oscillation Check”), check that the specified values If deviated, the zoom lens operates of itself, even if the zoom key is
of “VIDEO SYSTEM ADJUSTMENTS” are satisfied. the center position.
And check that the data of page: 0, address: 10 is “00”. If not, set Subject Not required
data: 00 to this address. Measuring Instrument Adjusting remote commander
1. 54MHz:PAL/66MHz:NTSC Origin Oscillation Check Adjustment Page F
(VC-319 board) Adjustment Address 11
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will Note1: Perform this adjustment under the condition that the zoom switch
become inconsistent. (RV001 of the control switch block (FK4400)) is surely connected.
Note2: Don’t touch the zoom switch during adjustment.
Subject Not required Note3: The data of page: 0, address: 10 must be “00”.
Measurement Point Pin <zc.> of IC2101 (R2132)
Or Pin qh of IC1503 Adjusting method:
Measuring Instrument Frequency counter Order Page Address Data Procedure
Specified Value Pin <zc.> of IC2101: 1 0 01 01 Set the data.
f=13500000 ± 272Hz 2 6 50 Read the data, and this data is
Pin qh of IC1503: named D50.
f=33000000 ± 498Hz (NTSC)
3 F 11 D50 Set the data, and press PAUSE
f=27000000 ± 402Hz (PAL)
button.
Note: NTSC model: DCR-PC105 4 0 01 00 Set the data.
PAL model: DCR-PC103E/PC104E/PC105E

Adjusting method:
Check that the frequency (f) satisfies the specified value.

36 25
37 24
IC1503
48 13
1 12

VC-319 board

IC2101

R2132

Fig. 6-1-9.

6-22
DCR-PC103E/PC104E/PC105/PC105E

3. HALL Adjustment Processing after Completing Adjustments:


Order Page Address Data Procedure
For detecting the position of the lens iris and ND filter, adjust AMP
1 6 01 00 Set the data, and press PAUSE
gain and offset.
button.
Subject Not required
2 0 03 00 Set the data.
Measurement Point Display data of page 1 (Note1)
3 0 01 00 Set the data.
Measuring Instrument Adjustment remote commander
Adjustment Page F
Adjustment Address 13 to 18, 92
Specified Value 1 D4 to DC
Specified Value 2 24 to 2C
Specified Value 3 D2 to DE
Specified Value 4 22 to 2E

Note1: Displayed data of page 1 of the adjustment remote commander.


1 : XX : XX
IRIS display data
ND display data
Note2: The data of page: 0, address: 10 must be “00”.

Switch setting:
POWER .................................................................. CAMERA

Adjusting method:
Order Page Address Data Procedure
1 0 01 01 Set the data.
2 6 01 6D Set the data, and press PAUSE button.
3 6 02 Check that the data changes to
“01”. (Note3)
4 6 01 00 Set the data, and press PAUSE button.

Note3: The adjustment data will be automatically input to page: F, address:


13 to 18, 92.

Checking method:
Order Page Address Data Procedure
1 0 03 03 Set the data.
2 6 01 01 Set the data, and press PAUSE button.
3 6 01 03 Set the data, and press PAUSE button.
4 1 Check that the IRIS display data
(Note1) satisfies the specified
value 1.
5 6 01 01 Set the data, and press PAUSE button.
6 1 Check that the IRIS display data
(Note1) satisfies the specified
value 2.
7 6 01 6B Set the data, and press PAUSE button.
8 6 01 69 Set the data, and press PAUSE
button.
9 1 Check that the ND display data
(Note1) satisfies the specified
value 3.
10 6 01 6B Set the data, and press PAUSE button.
11 1 Check that the ND display data
(Note1) satisfies the specified
value 4.

6-23
DCR-PC103E/PC104E/PC105/PC105E

4. MR Adjustment Processing after Completing Adjustments:


The MR (Magnet resistor) adjustment of the inner focus lens is Order Page Address Data Procedure
carried out automatically. In whichever case, the focus will be
1 6 01 00 Set the data, and press PAUSE
deviated during auto focusing/manual focusing.
button.
Subject Not required
2 0 01 00 Set the data.
Measurement Point Adjustment remote commander
3 Turn off the power and turn on
Measuring Instrument again
Adjustment Page F
Adjustment Address 58, 5A to 65
Specified Value1 40 to C0
Specified Value2 03 to 78
Specified Value3 88 to FD

Note1: Make the lens horizontal and perform this adjustment.


Note2: Perform this adjustment before “Flange Back Adjustment”.
Note3: The data of page: 0, address: 10 must be “00”.
Note4: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.

Adjusting method:
Order Page Address Data Procedure
1 0 01 01 Set the data.
2 6 01 BD Set the data, and press PAUSE
button.
3 6 02 Check that the data changes to
“01”. (Note5)
4 F 5A Check that the data satisfies the
specified value 1.
5 F 5B Check that the data satisfies the
specified value 1.
6 F 5C Check that the data satisfies the
specified value 1.
7 F 5D Check that the data satisfies the
specified value 1.
8 F 5E Check that the data satisfies the
specified value 2.
9 F 5F Check that the data satisfies the
specified value 3.
10 F 60 Check that the data satisfies the
specified value 2.
11 F 61 Check that the data satisfies the
specified value 3.
12 F 62 Check that the data satisfies the
specified value 2.
13 F 63 Check that the data satisfies the
specified value 3.
14 F 64 Check that the data satisfies the
specified value 2.
15 F 65 Check that the data satisfies the
specified value 3.

Note5: The adjustment data will be automatically input to page: F, address:


58, 5A to 65.

6-24
DCR-PC103E/PC104E/PC105/PC105E

5. Flange Back Adjustment Adjusting method:


(Using Minipattern Box) Order Page Address Data Procedure
The inner focus lens flange back adjustment is carried out
1 0 01 01 Set the data.
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing. 2 6 01 13 Set the data, and press PAUSE
button. (Note6)
Subject Siemens star chart with ND filter for
the minipattern box (Note1) 3 6 01 27 Set the data, and press PAUSE
button.
Measurement Point Adjustment remote commander
4 6 02 Check that the data changes to
Measuring Instrument
“01”. (Note7)
Adjustment Page F
5 F 57 Check the data is “00” to “0B”.
Adjustment Address 11, 48 to 58
Specified Value Data of page: F, address: 57 is “00” to Note6: Don’t touch the zoom switch during adjustment.
“0B”. Note7: The adjustment data will be automatically input to page: F, address:
11, 48 to 58.
Note1: Dark Siemens star chart.
Note2: This adjustment should be carried out upon completion of the Processing after Completing Adjustments:
following adjustments. “HALL Adjustment”, “MR Adjustment” Order Page Address Data Procedure
Note3: Make the lens horizontal and perform this adjustment.
Note4: The data of page: 0, address: 10 must be “00’. 1 6 01 00 Set the data, and press PAUSE
Note5: Check that the data of page: 6, address: 02 is “00”. If not, to page: button.
6, address: 01, set data: 00, and press the PAUSE button. 2 6 01 25 Set the data, and press PAUSE
button.
Switch setting:
3 6 01 00 Set the data, and press PAUSE
1) POWER .................................................................. CAMERA
button.
2) NIGHT SHOT .................................................................. OFF
3) COLOR SLOW SHUTTER (Function setting) ............... OFF 4 0 01 00 Set the data.
5 Perform “Flange Back Check”.
Preparations:
1) The minipattern box is installed as shown in the following
figure.
Note: The attachment lenses are not used.
2) Install the minipattern box so that the distance between it and
the front of the lens of the camcorder is less than 3cm.
3) Make the height of the minipattern box and the camcorder equal.
4) Check that the output voltage of the regulated power supply is
the specified voltage.
5) Check that at both the zoom lens TELE end and WIDE end,
the center of the Siemens star chart and center of the exposure
screen coincide.

Specified voltage:
The specified voltage varies according to the minipattern box, so
adjust the power supply output voltage to the specified voltage
wwritten on the sheet which is supplied with the minipattern box.
Below 3 cm

Minipattern box

Camcorder

Camera
table

Regulated power supply


Output voltage : Specified voltage ±0.01Vdc
Output current : more than 3.5A

Red (+)
Black (–)

Yellow (SENS +)

White (SENS –) Need not connected


Black (GND)

Fig. 6-1-10.

6-25
DCR-PC103E/PC104E/PC105/PC105E

6. Flange Back Adjustment 6-2. Flange Back Adjustment (2)


(Using Flange Back Adjustment Chart and Subject Perform this adjustment after performing “Flange Back Adjustment
More Than 500m Away) (1)”.
The inner focus lens flange back adjustment is carried out Subject Subject more than 500m away
automatically. In whichever case, the focus will be deviated during (Subjects with clear contrast such as
auto focusing/manual focusing. buildings, etc.)
Measurement Point Check operation on TV monitor
6-1. Flange Back Adjustment (1)
Measuring Instrument
Subject Flange back adjustment chart
(2.0 m from the front of the protection Adjustment Page F
glass) Adjustment Address 11, 48 to 58
(Luminance: 350 ± 50 lux)
Measurement Point Adjustment remote commander Note1: Make the lens horizontal and perform this adjustment.
Note2: The data of page: 0, address: 10 must be “00”.
Measuring Instrument Note3: Check that the data of page: 6, address: 02 is “00”. If not, to page:
Adjustment Page F 6, address: 01, set data: 00, and press the PAUSE button.
Adjustment Address 11, 48 to 58
Switch setting:
Specified Value Data of page: F, address: 57 is “00” to 1) POWER .................................................................. CAMERA
“0B”. 2) NIGHT SHOT .................................................................. OFF
3) COLOR SLOW SHUTTER (Function setting) ............... OFF
Note1: This adjustment should be carried out upon completion of the
following adjustments. “HALL Adjustment”, “MR Adjustment”
Note2: Make the lens horizontal and perform this adjustment.
Preparations:
Note3: The data of page: 0, address: 10 must be “00”. 1) Set the zoom lens to the TELE end and expose a subject that is
Note4: Check that the data of page: 6, address: 02 is “00”. If not, to page: more than 500m away (subject with clear contrast such as
6, address: 01, set data: 00, and press the PAUSE button. building, etc.) (Nearby subjects less than 500m away should
not be in the screen.)
Switch setting:
1) POWER .................................................................. CAMERA Adjusting method:
2) NIGHT SHOT .................................................................. OFF Order Page Address Data Procedure
3) COLOR SLOW SHUTTER (Function setting) ............... OFF
1 0 01 01 Set the data.
Preparations: 2 6 01 13 Set the data, and press PAUSE
1) Check that at both the zoom lens TELE end and WIDE end, button. (Note4)
the center of the chart for the flange back adjustment and center 3 Place a ND filter on the lens so
of the exposure screen coincide. that the optimum image is
obtain.
Adjusting method: 4 6 01 29 Set the data, and press PAUSE
Order Page Address Data Procedure button.
1 0 01 01 Set the data. 5 6 02 Check that the data changes to
2 6 01 13 Set the data, and press PAUSE “01”. (Note5)
button. (Note5)
Note4: Don’t touch the zoom switch during adjustment.
3 6 01 15 Set the data, and press PAUSE Note5: The adjustment data will be automatically input to page: F, address:
button. 11, 48 to 58.
4 6 02 Check that the data changes to
“01”. (Note6) Processing after Completing Adjustments:
5 F 57 Check the data is “00” to “0B”. Order Page Address Data Procedure
1 6 01 00 Set the data, and press PAUSE
Note5: Don’t touch the zoom switch during adjustment. button.
Note6: The adjustment data will be automatically input to page: F, address:
11, 48 to 58. 2 6 01 25 Set the data, and press PAUSE
button.
Processing after Completing Adjustments: 3 6 01 00 Set the data, and press PAUSE
Order Page Address Data Procedure button.
1 6 01 00 Set the data, and press PAUSE 4 0 01 00 Set the data.
button. 5 Perform “Flange Back Check”
2 6 01 25 Set the data, and press PAUSE
button.
3 6 01 00 Set the data, and press PAUSE
button.
4 0 01 00 Set the data.
5 Perform “Flange Back
Adjustment (2)”

6-26
DCR-PC103E/PC104E/PC105/PC105E

7. Flange Back Check 8. MAX GAIN Adjustment


Subject Siemens star Setting the minimum illumination.
(2.0m from the front of the lens) If it is not consistent, the image level required for taking subjects in
(Luminance : approx. 200 lux) low illuminance will not be produced (dark).
Measurement Point Check operation on TV monitor Subject Clear chart (Approx. 1m from the front
of the lens) Note1
Measuring Instrument
Adjustment Page F
Specified Value Focused at the TELE end and WIDE
end. Adjustment Address 19

Note1: The data of page: 0, address: 10 must be “00”. Note1: Shoot the clear chart with the zoom WIDE end. And adjust the
direction of the camera so that the chart is located in the center of
the screen.
Switch setting:
Note2: The data of page: 0, address: 10 must be “00”.
1) POWER .................................................................. CAMERA Note3: This adjustment should be carried out upon completion of “Flange
2) NIGHT SHOT (Menu setting) ......................................... OFF Back Adjustment”.
Note4: NTSC model: DCR-PC105
Note2: When the auto focus is ON, the lens can be checked if it is focused PAL model: DCR-PC103E/PC104E/PC105E
or not by observing the data on the page 1 of the adjustment remote
commander. Switch setting:
1) Select page: 0, address: 03, and set data: 0F. 1) POWER .................................................................. CAMERA
2) Page 1 shows the state of the focus. 2) NIGHT SHOT .................................................................. OFF
1 : 00 : XX
3) ZOOM .................................................................... WIDE end
Odd: Focused 4) DIGITAL ZOOM (Menu setting) .................................... OFF
Even: Unfocused 5) STEADY SHOT (Menu setting) ...................................... OFF
Checking method: Adjusting method:
1) Select page: 6, address: 40, and set data: 01.
2) Select page: 6, address: 41, and set data: 01. Order Page Address Data Procedure
3) Place the Siemens star 2.0m from the front of the lens. 1 0 01 01 Set the data.
4) To open the IRIS, decrease the luminous intensity to the 2 6 2C 01 Set the data.
Siemens star up to a point before noise appear on the image. 3 6 40 01 Set the data.
5) Shoot the Siemens star with the zoom TELE end.
6) Turn on the auto focus. 4 6 96 Set the following data.
7) Check that the lens is focused (Note2). 2D (NTSC), 1D (PAL)
8) Select page: 6, address: 21, and set data: 10. 5 6 97 00 Set the data.
9) Shoot the Siemens star with the zoom WIDE end. 6 6 01 6F Set the data, and press PAUSE
10) Observe the TV monitor and check that the lens is focused. button.
7 6 02 Check that the data changes to
Processing after Completing Adjustments: “01”. (Note5)
1) Select page: 6, address: 21, and set data: 00.
2) Select page: 6, address: 40, and set data: 00. Note5: The adjustment data will be automatically input to page: F,
3) Select page: 6, address: 41, and set data: 00. address: 19.
4) Select page: 0, address: 03, and set data: 00.
Processing after Completing Adjustments
Order Page Address Data Procedure
1 6 2C 00 Set the data.
2 6 40 00 Set the data.
3 6 96 00 Set the data.
4 6 97 00 Set the data.
5 6 01 00 Set the data, and press PAUSE
button.
6 0 01 00 Set the data.

6-27
DCR-PC103E/PC104E/PC105/PC105E

9. Picture Frame Setting


(Color Reproduction Adjustment Frame)
When performing “Color Reproduction Adjustment” and “LV
Standard Data Input”, set the picture frame to “Color reproduction
adjustment frame”.
Subject
Color bar chart (Color reproduction adjustment frame)
(1.5m from the front of the lens)
Measurement Point Video terminal of AUDIO/VIDEO jack
Measuring Instrument Oscilloscope,
TV monitor (Under scan mode)
Specified Value A=B, C=D, E=F

Note1: The following adjustments should be carried out upon completion


of “Flange Back Adjustment”.
Note2: The data of page: 0, address: 10 must be “00”.
Check on the oscilloscope
Switch setting:
1) POWER .................................................................. CAMERA 1. Horizontal period
2) NIGHT SHOT .................................................................. OFF A=B C=D
3) FOCUS .................................................................. MANUAL
4) DIGITAL ZOOM (Menu setting) .................................... OFF B C
5) STEADY SHOT (Menu setting) ...................................... OFF A D

Setting method:
1) Adjust the zoom and the camera direction, and set to the
specified position.
2) Mark the position of the picture frame on the monitor display,
and adjust the picture frame to this position in following
adjustments using “Color reproduction adjustment frame”.

Fig. 6-1-11.

2. Vertical period

E E=F F

Fig. 6-1-12.

Check on the monitor TV (Underscanned mode)

Color bar chart picture frame Monitor TV picture frame


Fig. 6-1-13.

6-28
DCR-PC103E/PC104E/PC105/PC105E

10. Color Reproduction Adjustment


Adjust the color Separation matrix coefficient so that proper color
reproduction is produced.
Subject Color bar chart
(Color reproduction adjustment frame)
Measurement Point Video terminal of AUDIO/VIDEO jack
Measuring Instrument Vectorscope
Adjustment Page F
Adjustment Address 37, 39, 40, 41
Specified Value All color luminance points should settle
within each color reproduction frame.
For NTSC model
Note1: The data of page: 0, address: 10 must be “00”.
Note2: NTSC model: DCR-PC105
PAL model: DCR- PC103E/PC104E/PC105E

Switch setting:
1) POWER .................................................................. CAMERA
2) NIGHT SHOT .................................................................. OFF
3) FOCUS .................................................................. MANUAL
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADY SHOT (Menu setting) ...................................... OFF

Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 6, address: 9D, and set data: 19.
3) Select page: 6, address: 01, set data: 3D, and press the PAUSE
Burst position
button.
4) Select page: F, address: F0, set the following data, and press
the PAUSE button.
37 (NTSC), B7 (PAL)
5) Adjust the GAIN and PHASE of the vectorscope, and adjust
For PAL model
the burst luminance point to the burst position of the color
reproduction frame.
6) Change the data of page: F, address: 37, 39, 40 and 41, and
Burst position
settle each color luminance point in each color reproduction
frame.
Note: Be sure to press the PAUSE button of the adjustment remote
commander before changing the addresses. If not, the new data
will not be written to the memory.

Processing after Completing Adjustments:


1) Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
2) Select page: 6, address: 9D, and set data: 00.
3) Select page: 0, address: 01, and set data: 00.

Fig. 6-1-14.

6-29
DCR-PC103E/PC104E/PC105/PC105E

11. LV Standard Data Input


Adjust the normal coefficient of the light value.
Subject Clear chart
(Color reproduction adjustment frame)
Measurement Point Display data of page 1 (Note4)
Measuring Instrument Adjustment remote commander
Adjustment Page F
Adjustment Address 1A, 1B
Specified Value 0FC0 to 1040

Note1: This adjustment should be carried out upon completion of “Color


Reproduction Adjustment”.
Note2: The data of page: 0, address: 10 must be “00”.
Note3: Check that the data of page: 6, address: 02 is “00”. If not, turn off
the power and turn on again.
Note4: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data

Note5: The adjustment data will be automatically input to page: F, address:


1A, 1B.

Switch setting:
1) POWER .................................................................. CAMERA
2) NIGHT SHOT .................................................................. OFF
3) FOCUS .................................................................. MANUAL
4) DIGITAL ZOOM (Menu setting) .................................... OFF

Adjusting method:
Order Page Address Data Procedure
1 0 01 01 Set the data.
2 Wait for more than 6 sec.
3 6 40 01 Set the data, and press PAUSE
button.
4 6 01 0D Set the data, and press PAUSE
button.
5 6 02 Check that the data changes to
“01”. (Note5)
6 0 03 1E Set the data.
7 1 Check that the display data (Note5)
satisfies the specified value.

Processing after Completing Adjustments


Order Page Address Data Procedure
1 6 01 00 Set the data, and press PAUSE
button.
2 6 40 00 Set the data.
3 0 03 00 Set the data.
4 0 01 00 Set the data.

6-30
DCR-PC103E/PC104E/PC105/PC105E

12. Picture Frame Setting (All White Frame) Processing after Completing Adjustments
When performing “Auto White Balance Standard Data Input”, “Auto After completing “Auto White Balance Standard Data Input”, “Auto
White Balance Adjustment” and “White Balance Check”, set the White Balance Adjustment” and “White Balance Check”, release
picture frame to “All white frame”. the data setting.
Subject Color bar chart Order Page Address Data Procedure
Clear chart (All white frame) 1 6 90 00 Set the data.
(1.5m from the front of the lens)
2 6 91 00 Set the data.
Measurement Point Video terminal of AUDIO/VIDEO
3 6 92 00 Set the data.
jack
4 6 93 00 Set the data.
Measuring Instrument TV monitor (Under scan mode)
Specified Value Whole of the screen is white

Note1: The data of page: 0, address: 10 must be “00”.


Note2: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
XL or YL data
XH or YH data

Switch setting:
1) POWER .................................................................. CAMERA
2) NIGHT SHOT .................................................................. OFF
3) FOCUS .................................................................. MANUAL
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADY SHOT (Menu setting) ...................................... OFF

Setting method:
Order Page Address Data Procedure
1 Attach the color bar chart.
2 Adjust the zoom to TELE side
from WIDE side, and stop it when
the black frame of the chart
disappears. (At this time, the
yellow bar and blue bar must be
seen almost perfectly.)
3 Remove the color bar chart and
attach the clear chart.
4 Check that whole of the screen
is white.
5 6 04 18 Set the data.
6 1 Read the XH and XL data.
(Note2)
7 6 04 22 Set the data.
8 1 Read the YH and YL data.
(Note2)
9 6 04 00 Set the data.
10 Perform the following
adjustments.

How to reset the zoom and focus when they deviated:


If the zoom and focus deviated due to some reason reset them in the
following method.
Order Page Address Data Procedure
1 6 90 XL Set the data.
2 6 91 XH Set the data.
3 6 92 YL Set the data.
4 6 93 YH Set the data.
5 6 01 79 Set the data, and press PAUSE
button.

6-31
DCR-PC103E/PC104E/PC105/PC105E

13. Auto White Balance Standard Data Input


Adjust the white balance reference at 3200K.
Subject Clear chart (All white frame) (Note4)
Adjustment Page F
Adjustment Address 2E to 31

Note1: This adjustment should be carried out upon completion of “Color


Reproduction Adjustment””.
Note2: The data of page: 0, address: 10 must be “00”.
Note3: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note4: Perform “12. Picture Frame Setting (All White Frame)” before
this adjustment.

Switch setting:
1) POWER .................................................................. CAMERA
2) NIGHT SHOT .................................................................. OFF
3) FOCUS .................................................................. MANUAL
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADY SHOT (Menu setting) ...................................... OFF

Adjusting method:
Order Page Address Data Procedure
1 Check that the whole of the screen
is white. If not, perform “12.
Picture Frame Setting (All White
Frame)”.
2 0 01 01 Set the data.
3 Wait for more than 2 sec.
4 6 01 11 Set the data, and press PAUSE
button.
5 6 01 0B Set the data, and press PAUSE
button.
6 6 02 Check that the data changes to
“01”. (Note5)
7 Perform “Auto White Balance
Adjustment”.

Note5: The adjustment data will be automatically input to page: F, address:


2E to 31.

Processing after Completing Adjustments:


Order Page Address Data Procedure
1 6 01 00 Set the data, and press PAUSE
button.
2 Perform “Auto White Balance
Adjustment”.

6-32
DCR-PC103E/PC104E/PC105/PC105E

14. Auto White Balance Adjustment Adjusting method:


Adjust to the proper auto white balance output data. Order Page Address Data Procedure
If it is not correct, auto white balance and color reproducibility will
1 Check that the whole of the
be poor.
screen is white. If not, perform
Subject Clear chart (All white frame) “12. Picture Frame Setting (All
Filter Filter C14 for color temperature White Frame)”.
correction 2 Place the C14 filter for color
Measurement Point Display data of page 1 (Note3) temperature correction on the
Measuring Instrument Adjustment remote commander lens.
Adjustment Page F 3 0 01 01 Set the data.
Adjustment Address 32 to 35 4 F 44 Write down the data.
Specified Value R ratio: 2C6C to 2CEC 5 F 44 2C Set the data, and press PAUSE
B ratio: 5A90 to 5B10 button.
6 F 45 Write down the data.
Note1: This adjustment should be carried out upon completion of “Auto 7 F 45 AC Set the data, and press PAUSE
White Balance Standard Data Input”.
button.
Note2: The data of page: 0, address: 10 must be “00”.
Note3: Displayed data of page 1 of the adjustment remote commander. 8 F 46 Write down the data.
1 : XX : XX 9 F 46 5A Set the data, and press PAUSE
Display data
button.
Switch setting: 10 F 47 Write down the data.
1) POWER .................................................................. CAMERA 11 F 47 D0 Set the data, and press PAUSE
2) NIGHT SHOT .................................................................. OFF button.
3) FOCUS .................................................................. MANUAL 12 6 01 83 Set the data, and press PAUSE
4) DIGITAL ZOOM (Menu setting) .................................... OFF button.
5) STEADY SHOT (Menu setting) ...................................... OFF
13 6 01 81 Set the data, and press PAUSE
button.
14 6 02 Check that the data changes to
“01”. (Note4)
15 6 01 3F Set the data, and press PAUSE
button.
16 0 03 04 Set the data.
17 1 Check that the display data
(Note3) satisfies the R ratio
specified value.
18 0 03 05 Set the data.
19 1 Check that the display data
(Note3) satisfies the B ratio
specified value.

Note4: The adjustment data will be automatically input to page: F, address:


32 to 35.

Processing after Completing Adjustments:


Order Page Address Data Procedure
1 F 44 Set the data that is written down
at step 4, and press PAUE button.
2 F 45 Set the data that is written down
at step 6, and press PAUE button.
3 F 46 Set the data that is written down
at step 8, and press PAUE button.
4 F 47 Set the data that is written down at
step 10, and press PAUE button.
5 6 01 00 Set the data and press PAUSE
button.
6 0 01 00 Set the data.
7 0 03 00 Set the data.
8 Perform “White Balance Check”.

6-33
DCR-PC103E/PC104E/PC105/PC105E

15. White Balance Check Processing after Completing Adjustments


Subject Clear chart (All white frame) (Note2) Order Page Address Data Procedure
Filter Filter C14 for color temperature 1 6 01 00 Set the data, and press PAUSE
correction button.
ND filter 1.0 and 0.4 and 0.1 2 6 90 00 Set the data.
Measurement Point Video terminal of AUDIO/VIDEO jack 3 6 91 00 Set the data.
Measuring Instrument Vectorscope 4 6 92 00 Set the data.
Specified Value Fig. 6-1-15. A to B 5 6 93 00 Set the data.
Note1: The data of page: 0, address: 10 must be “00”. 6 0 03 00 Set the data.
Note2: Perform “12. Picture Frame Setting (All White Frame)”.

Switch setting:
1) POWER .................................................................. CAMERA
2) NIGHT SHOT .................................................................. OFF
3) FOCUS .................................................................. MANUAL
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADY SHOT (Menu setting) ...................................... OFF

Checking method:
Order Page Address Data Procedure R-Y 2mm

Indoor white balance check


1 Check that the lens is not B-Y
covered with either filter.
2 6 01 0F Set the data, and press PAUSE
button. 2mm
3 Check that the center of the
white luminance point is within Fig. 6-1-15(A).
the circle shown Fig. 6-1-15. A.
4 6 01 00 Set the data, and press PAUSE
button. R-Y
1mm
Outdoor white balance check
5 Place the C14 filter on the lens. B-Y
0.5mm
6 6 01 3F Set the data, and press PAUSE
button. 3mm

7 Check that the center of the


white luminance point is within 3mm
the circle shown Fig. 6-1-15. B.
Fig. 6-1-15(B).
8 Remove the C14 filter.
LV data check
9 Place the ND filter 1.5
(1.0+0.1+0.4) on the lens.
10 6 01 00 Set the data, and press PAUSE
button.
11 0 03 06 Set the data.
12 1 Check that the display data
(Note3) satisfies the specified
value.
Specified value: 8000 to 8BC0

Note3: Displayed data of the adjustment remote commander.


1 : XX : XX
Display data

6-34
DCR-PC103E/PC104E/PC105/PC105E

16. Mechanical Shutter Adjustment 17. Steady Shot Check


Adjustment Page F Precautions on the Parts Replacement
There are two types of repair parts.
Adjustment Address 76 to 8B
Type A: ENC03MA
Type B: ENC03MB
Note1: The data of page: 0, address: 10 must be “00”.
Note2: NTSC model: DCR-PC105 Replace the broken sensor with a same type sensor. If replace with
PAL model: DCR-PC103E/PC104E/PC105E other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01. Precautions on Angular Velocity Sensor
2) Input the following data to page: F, addresses: 76 to 8B. The sensor incorporates a precision oscillator. Handle it with care
Note: Press the PAUSE button of the adjustment remote as if it dropped, the balance of the oscillator will be disrupted and
commander each time to set the data. operations will not be performed properly.
Subject Arbitrary
Data
Address Measurement Point Display data of page 1 (Note1)
NTSC PAL
Measuring Instrument Adjustment remote commander
76 60 4E
Specified Value 2400 to 5200
77 A6 9E
78 49 3B Note1: Displayed data of the adjustment remote commander.
79 75 75 1 : XX : XX
Display data
7A 3E 32 Note2: The data of page: 0, address: 10 must be “00”.
7B 6D 77
7C 36 2C Switch setting:
1) STEADY SHOT (Menu setting) ....................................... ON
7D AB 6F
2) ZOOM .................................................................... TELE end
7E 2C 24
7F 9E 86 Adjusting method:
80 68 68 Order Page Address Data Procedure
81 7A 7B Pitch sensor check
82 7A 7A (CD-444 board SE5202)
83 6A 6B 1 0 03 11 Set the data.
84 60 61 2 1 Check that the display data (Note1)
satisfies the specified value. (Note3)
85 20 1F
Yaw sensor check
86 78 7B
(CD-444 board SE5201)
87 80 80
3 0 03 12 Set the data.
88 80 80
4 1 Check that the display data (Note1)
89 80 80 satisfies the specified value.(Note3)
8A 80 80 5 0 03 00 Set the data.
8B 79 7A 6 Move the camcorder, and check
that the steady shot operations
3) Select page: 0, address: 01, and set data: 00. have been performed normally

Note3: Don’t move the camcoder.

6-35
DCR-PC103E/PC104E/PC105/PC105E

18. Strobe Light Level Adjustment 19. Strobe White Balance Adjustment & Check
(DCR-PC105/PC105E) (DCR-PC105/PC105E)
Adjust the light level when the strobe light flashes. Adjust and check the white balance when the strobe light flashes.
Subject Paper which reflection rate is 18% Subject Paper which reflection rate is 18%
(50cm from the front of the lens)(Note1) (50cm from the front of the lens)(Note1)
Measurement Point Adjustment remote commander Measurement Point Video terminal of AUDIO/VIDEO jack
Measuring Instrument Measuring Instrument Vectorscope
Adjustment Page F Adjustment Page F
Adjustment Address 8C to 91 Adjustment Address 3E, 3F
Specified Value Data of page: 6, address: B8 is “00”. Specified Value Fig. 6-1-16.

Note1: Background paper (J-250-130-A). Perform this adjustment in the Note1: Background paper (J-250-130-A). Perform this adjustment in the dark
dark room or use the flash adjustment box. (Refer to “1-1- room or use the flash adjustment box. (Refer to “1-1-3.Precaution”.)
3.Precaution”.) Note2: Any light other than the strobe light should not light up the paper.
Note2: Any light other than the strobe light should not light up the paper. Note3: This adjustment should be carried out upon completion of “HALL
Note3: This adjustment should be carried out upon completion of “HALL Adjustment”, “Flange Back Adjustment”, , “Auto White Balance
Adjustment”, “Flange Back Adjustment”. Adjustment”, “Strobe Light Level Adjustment”
Note4: The data of page: 0, address: 10 must be “00”. Note4: After the power is turned on, this adjustment can be done only once.
Note5: Check that the data of page: 6, address: 02 is “00”. If not, to page: Note5: The data of page: 0, address: 10 must be “00”.
6, address: 01, set data: 00, and press the PAUSE button. Note6: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1) POWER .................................................................. CAMERA Switch setting:
2) FLASH ......................................................................... OPEN 1) POWER .................................................................. CAMERA
(Press FLASH ( ) button and set to the forced flash mode ( ), 2) FLASH ......................................................................... OPEN
and press PHOTO button.) (Press FLASH ( ) button and set to the forced flash mode
3) NIGHT SHOT .................................................................. OFF ( ), and press PHOTO button.)
3) NIGHT SHOT .................................................................. OFF
Adjusting method:
Order Page Address Data Procedure Adjusting method:
1 0 01 01 Set the data. Order Page Address Data Procedure
2 7 05 04 Set the data. (Note6) 1 0 01 01 Set the data.
3 6 01 67 Set the data, and press PAUSE 2 7 05 04 Set the data. (Note7)
button. 3 6 01 B9 Set the data, and press PAUSE
4 Check the flashing. button.
5 6 02 Check that the data is “01”. 4 Check the flashing.
(Note7) 5 6 02 Check that the data is “01”.
6 6 B8 Check that the data is “00”. (Note8)
6 6 01 00 Set the data, and press PAUSE
Note6: Use the STOP button of the adjustment remote commander. button.
Note7: The adjustment data will be automatically input to page: F, address:
8C to 91. 7 6 01 E7 Set the data, and press PAUSE
button.
Processing after Completing Adjustments: 8 Check the flashing.
Order Page Address Data Procedure 9 Wait for 3 sec.
1 6 01 00 Set the data, and press PAUSE 10 Check that the center of the
button. white luminance point is within
2 7 05 00 Set the data. the circle shown Fig. 6-1-16.
3 0 01 00 Set the data. Note7: Use the STOP button of the adjustment remote commander.
Note8: The adjustment data will be automatically input to page: F, address:
R-Y 2mm 3E, 3F.

Processing after Completing Adjustments:


B-Y Order Page Address Data Procedure
1 6 01 00 Set the data, and press PAUSE
button.
2mm 2 7 05 00 Set the data.
3 0 01 00 Set the data.
Fig. 6-1-16.

6-36
DCR-PC103E/PC104E/PC105/PC105E

COVER

1-4. COLOR ELECTRONIC VIEWFINDER 1. VCO Adjustment (VC-319 board)


SYSTEM ADJUSTMENT Set the VCO free-run frequency. If deviated, the EVF screen will be
blurred.
Note1: When replacing the LCD unit, be careful to prevent damages
caused by static electricity. Note: Do either of the automatic adjustment or the manual adjustment.
Note2: Before performing the adjustments, check the data of page: 0,
address: 10 is “00”. If not, set data: 00 to this address. 1-1. Manual Adjustment
Note3: As the PANEL CLOSE switch is attached to the cabinet (R), this
Mode Camera
cabinet must be attached when performing adjustments.
If you perform the adjustments with cabinet (R) removed, set the Subject Arbitrary
following data. Measurement Point Pin 2 of IC4202 (HDO)
1) Select page: 3, address: C4, and set data: 67.
2) Select page: 3, address: C5, and set data: 01. Measuring Instrument Frequency counter
Reset the data after completing adjustment. Adjustment Page C
1) Select page: 3, address: C4, and set data: 00.
Adjustment Address 36, 37
2) Select page: 3, address: C5, and set data: 00.
Note4: NTSC model: DCR-PC105 Specified Value f = 15734 ± 30Hz (NTSC)
PAL model: DCR-PC103E/PC104E/PC105E f = 15625 ± 30Hz (PAL)

Switch setting: Note1: The data of page: 0, address: 10 must be “00”.


LCD panel ........................................................................... Closed
Adjusting method:
[Measuring points]
Order Page Address Data Procedure
The measuring points for manual adjustments are CL1001 (EVF
VG) and Pin2 of IC4202 (HDO) of VC-319 board. 1 0 01 01 Set the data.
2 C 36 Change the data and set the VCO
frequency (f) to the specified value.
3 C 36 Press PAUSE button.
IC4202 4 C 36 Read the data, and this data is
24 13
25 12 named D36.
5 Convert D36 to decimal notation,
36 1
37 48
and obtain D36’. (Note2)
6 Calculate D37’ using following
VC-319 board equations (Decimal calculation)
[NTSC model]
CN1018
(CPC) When D36’ 231
D37’=D36’ + 24
When D36’ > 231
CL1001
D37’ = 255
[PAL model]
When D36’ 24
D37’=D36’ – 24
When D36’ < 24
D37’ = 0
Fig 6-1-17.
7 Convert D37’ to a hexadecimal
number, and obtain D37. (Note2)
8 C 37 D37 Set the data, and press PAUSE
button.
9 0 01 00 Set the data.

Note2: Refer to “Table 6-4-1. Hexadecimal-decimal Conversion Table”.

6-37
DCR-PC103E/PC104E/PC105/PC105E

1-2. Automatic Adjustment Order Page Address Data Procedure


18 Convert D36 to decimal notation,
Mode Camera and obtain D36’. (Note2)
Subject Arbitrary 19 Calculate D37’ using following
Measurement Point Check on EVF screen equations (Decimal calculation)
Measuring Instrument [NTSC model]
When D36’ 231
Adjustment Page C
D37’ =D36’ + 24
Adjustment Address 36, 37 When D36’ >231
Specified Value The EVF screen should be stable. D37’ =255
[PAL model]
Note1: The data of page: 0, address: 10 must be “00”. When D36’ 24
D37’ = D36’ – 24
Adjusting method: When D36’ < 24
Order Page Address Data Procedure D37’ = 0
1 0 01 01 Set the data. 20 Convert D37’ to a hexadecimal
number, and obtain D37. (Note2)
2 C 5A 73 Set the data, and press PAUSE
button. 21 C 37 D37 Set the data, and press PAUSE
button.
3 C 36 Set the following data, and press
PAUSE button. 22 C 5A F2 Set the data, and press PAUSE
58 (NTSC), 70 (PAL) button.
4 C 36 Read the data, and this data is 23 0 01 00 Set the data.
named PRESET DATA.
Note2: Refer to “Table 6-4-1. Hexadecimal-decimal Conversion Table”.
5 C 36 Add 30 (Hexadecimal) to the
data and press PAUSE button.
PRESET DATA for NTSC model
6 C 36 Check the EVF screen.
PRESET DATA New PRESET DATA
When the screen is stable,
proceed to step 10. 58 40
When the screen is unstable, 40 28
proceed to step 7. 28 10
7 Using Table 6-1-14 or Table 6-1- Table 6-1-14.
16, read the new PRESET DATA
corresponding to the PRESET PRESET DATA New PRESET DATA
DATA. 58 70
8 C 36 Set the new PRESET DATA and 70 88
press PAUSE button. 88 A0
9 Return to step 4. A0 B8
10 C 36 Set the PRESET DATA and
Table 6-1-15.
press PAUSE button.
11 C 36 Subtract 30 (Hexadecimal) from PRESET DATA for PAL model
the data and press PAUSE button.
PRESET DATA New PRESET DATA
12 C 36 Check the EVF screen. 70 58
When the screen is stable,
58 40
proceed to step 16.
When the screen is unstable, 40 28
proceed to step 13. Table 6-1-16.
13 Using Table 6-1-15 or Table 6-1-
17, read the new PRESET DATA PRESET DATA New PRESET DATA
corresponding to the PRESET 70 88
DATA. 88 A0
14 C 36 Set the new PRESET DATA and A0 B8
press PAUSE button. B8 D0
15 Return to step 4. D0 E8
16 C 36 Set the PRESET DATA and Table 6-1-17.
press PAUSE button.
17 C 36 Read the data, and this data is
named D36.

6-38
DCR-PC103E/PC104E/PC105/PC105E

2. RGB AMP Adjustment (VC-319 board) 2-2. Manual Adjustment


Set the D range of the RGB decoder used to drive the LCD to the
specified value. If deviated, the LCD screen will become blackish Mode Camera
or saturated (whitish).
Subject Arbitrary
Note: Do either of the automatic adjustment or the manual adjustment. Measurement Point CL1001 (EVF VG)
Measuring Instrument Oscilloscope
2-1. Automatic Adjustment Adjustment Page C
Adjustment Address 39
Mode Camera
Specified Value A = 7.00 ± 0.05V
Subject Arbitrary
Adjustment Page C Note: The data of page: 0, address: 10 must be “00”.
Adjustment Address 39
Adjusting method:
Note: The data of page: 0, address: 10 must be “00”. Order Page Address Data Procedure
1 0 01 01 Set the data.
Adjusting method:
2 C 39 Change the data and set the
Order Page Address Data Procedure voltage (A) between the reversed
1 0 01 01 Set the data. waveform pedestal and non-
2 3 01 50 Set the data, and press PAUSE reversed waveform pedestal to the
button. specified value.
3 3 02 Check that the data changes from 3 C 39 Press PAUSE button.
“50” to “00”. 4 0 01 00 Set the data.
4 3 01 00 Set the data, and press PAUSE
button.
5 0 01 00 Set the data. Pedestal

2H
Pedestal

Fig. 6-1-18.

6-39
DCR-PC103E/PC104E/PC105/PC105E

3. Contrast Adjustment (VC-319 board) 3-2. Manual Adjustment


Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated Mode Camera
(whitish).
Subject Arbitrary
Note: Do either of the automatic adjustment or the manual adjustment. Measurement Point CL1001 (EVF VG)
Measuring Instrument Oscilloscope
3-1. Automatic Adjustment Adjustment Page C
Adjustment Address 3E
Mode Camera
Specified Value A = 2.40 ± 0.05V
Subject Arbitrary
Adjustment Page C Note: The data of page: 0, address: 10 must be “00”.
Adjustment Address 3E
Adjusting method:
Note: The data of page: 0, address: 10 must be “00”. Order Page Address Data Procedure
1 0 01 01 Set the data.
Adjusting method:
2 C 3E Change the data and set the
Order Page Address Data Procedure voltage (A) between the 100 IRE
1 0 01 01 Set the data. and 0 IRE (pedestal) to the
2 3 01 51 Set the data, and press PAUSE specified value. (The data should
button. be “00” to “7F”.)
3 3 02 Check that the data changes from 3 C 3E Press PAUSE button.
“51” to “00”. 4 0 01 00 Set the data.
4 3 01 00 Set the data, and press PAUSE
button.
5 0 01 00 Set the data.

100 IRE

2H
Pedestal

Fig. 6-1-19.

6-40
DCR-PC103E/PC104E/PC105/PC105E

4. White Balance Adjustment (VC-319 board)

Correct the white balance.


If deviated, the reproduction of the EVF screen may degenerate.
Mode Camera
Subject Arbitrary
Measurement Point Check on EVF screen
Measuring Instrument
Adjustment Page C
Adjustment Address 3C, 3D
Specified Value The EVF screen should not be colored.

Note1: Check the white balance only when replacing the following parts.
If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC4201
Note2: The data of page: 0, address: 10 must be “00”.

Adjusting method:
Order Page Address Data Procedure
1 0 01 01 Set the data.
2 C 3C 8F Set the data, and press PAUSE
button.
3 C 3D 70 Set the data, and press PAUSE
button.
4 C 3D Check that the EVF screen is not
colored. If not colored, proceed to
step 10.
5 C 3C Change the data so that the EVF
screen is not colored.
6 C 3C Press PAUSE button.
7 C 3D Change the data so that the EVF
screen is not colored.
8 C 3D Press PAUSE button.
9 C 3D If the EVF screen is colored,
repeat steps 5 to 9.
10 0 01 00 Set the data.

6-41
DCR-PC103E/PC104E/PC105/PC105E

COVER

1-5. LCD SYSTEM ADJUSTMENT 1. LCD Automatic Adjustment (PD-193 board)


This adjustment does the following adjustment items automatically.
Note1: The back light (fluorescent tube) is driven by a high voltage AC VCO adjustment
power supply. Therefore, do not touch the back light holder to RGB AMP adjustment
avoid electrical shock. Contrast adjustment
Note2: When replacing the LCD unit, be careful to prevent damages PSIG black adjustment
caused by static electricity.
Note3: Before performing the adjustments, check the data of page: 0, Mode VTR stop
address: 10 is “00”. If not, set data: 00 to this address. Signal No signal
Note4: NTSC model: DCR-PC105
PAL model: DCR-PC103E/PC104E/PC105E
Adjustment Page C
Adjustment Address 47, 48 (VCO adj.)
4A (RGB AMP adj.)
4F (Contrast adj.)
52 (PSIG black adj.)

Note1: The data of page: 0, address: 10 must be “00”.

Adjusting method:
Order Page Address Data Procedure
1 0 01 01 Set the data.
2 C 68 Check that the data is “0F”.
3 3 01 5A Set the data, and press PAUSE
button.
4 3 02 Check that the data is “00”.
5 3 03 Check that the data is “00”.
(Note2)
6 C 47 Read the data, and this data is
named D47.
7 Convert D47 to decimal
notation, and obtain D47’.
(Note3)
8 Calculate D48’ using following
equations (Decimal calculation)
[NTSC model]
When D47’ 235
D48’= D47’+20
When D47’ > 235
D48’= 255
[PAL model]
When D47’ 20
D48’= D47’– 20
When D47’< 20
D48’= 0
9 Convert D48’ to a hexadecimal
number, and obtain D48. (Note3)
11 C 48 D48 Set the data, and press PAUSE
button.
12 0 01 00 Set the data.

Note2: If the data changes to “01”, adjustment has errors. Contents of the
error is written into page: 3, addresses: C6. See the following table.

Data of page: 3, Contents of error


address: 06
53 RGB AMP adjustment error
54 Contrast adjustment error
56 PSIG black adjustment error
58 VCO adjustment error

Note3: Refer to “Table 6-4-1. Hexadecimal-decimal Conversion Table”.

6-42
DCR-PC103E/PC104E/PC105/PC105E

2. V COM Adjustment (PD-193 board) 3. White Balance Adjustment (PD-193 board)


Set the DC bias of the common electrode drive signal of LCD to the Correct the white balance.
specified value. If deviated, the reproduction of the LCD screen may degenerate.
If deviated, the LCD display will move, producing flicker and Mode VTR stop
conspicuous vertical lines.
Signal No signal
Mode VTR stop
Measurement Point Check on LCD screen
Signal No signal
Measuring Instrument
Measurement Point Check on LCD display
Adjustment Page C
Measuring Instrument
Adjustment Address 4D, 4E
Adjustment Page C
Specified Value The LCD screen should not be colored.
Adjustment Address 49
Specified Value The brightness difference between the Note1: Check the white balance only when replacing the following parts.
section A and section B is minimum. If necessary, adjust them.
1. LCD panel
Note1: This adjustment should be carried out upon completion of the LCD 2. Light induction plate
automatic adjustment. 3. IC600
Note2: The data of page: 0, address: 10 must be “00”. Note2: The data of page: 0, address: 10 must be “00”.

Adjusting method: Adjusting method:


Order Page Address Data Procedure Order Page Address Data Procedure
1 0 01 01 Set the data. 1 0 01 01 Set the data.
2 C 49 Change the data so that the 2 C 4D 7D Set the data, and press PAUSE
brightness of the section A and button.
that of the section B is equal. 3 C 4E 5F Set the data, and press PAUSE
3 C 49 Press PAUSE button. button.
4 0 01 00 Set the data. 4 C 4E Check that the LCD screen is not
colored. If not colored, proceed to
step 10.
5 C 4D Change the data so that the LCD
screen is not colored.
B A 6 C 4D Press PAUSE button.
7 C 4E Change the data so that the LCD
A B screen is not colored.
8 C 4E Press PAUSE button.
B A 9 C 4E If the LCD screen is colored,
repeat steps 5 to 9.
10 0 01 00 Set the data.
A B

Fig. 6-1-20.

6-43
DCR-PC103E/PC104E/PC105/PC105E

COVER

6-2. MECHANISM SECTION 2-3. TAPE PATH ADJUSTMENT


ADJUSTMENT 1. Preparation for Adjustment

On the mechanism section adjustment 1) Clean the tape running side (tape guide, drum, capstan shaft,
For detail of mechanism section adjustments, checks, and pinch roller, etc.).
replacement of mechanism parts, refer to the separate volume “DV 2) Connect the adjustment remote commander to the LANC jack.
MECHANICAL ADJUSTMENT MANUAL Z Mechanism ”. 3) Turn the HOLD switch of the adjustment remote commander
Note: Before performing the adjustments, check the data of page: 0, to the ON position.
address: 10 is “00”. If not, set data: 00 to this address.
4) Connect an oscilloscope to VC-319 board CN1018 via the CPC-
6 flexible jig (J-6082-370-C) and CPC-6 terminal board jig (J-
2-1. HOW TO ENTER RECORD MODE WITHOUT
6082-371-A).
CASSETTE
Channel 1: VC-319 board, CN1018 Pin w; (Note)
1) Connect the adjustment remote commander to the LANC jack.
External trigger: VC-319 board, CN1018 Pin qj
2) Turn the HOLD switch of the adjustment remote commander Note: Connect a 75Ω resistor between Pins w; of CN1018 and ql
to the ON position. (GND).
3) Close the cassette compartment without the cassette. 5) Playback the alignment tape for tracking. (XH2-1)
4) Select page: 3, address: 01, and set data: 0C, and press the 6) Select page: 3, address: 33, and set data: 08.
PAUSE button of the adjustment remote commander. 7) Select page: 3, address: 26, set data: 31, and press PAUSE
(The mechanism enters the record mode automatically.) button.
Note: The function buttons becomes inoperable. 8) Check that the oscilloscope RF waveform is normal at the
5) To quit the record mode, select page: 3, address: 01, set data: entrance and exit.
00, and press the PAUSE button of the adjustment remote If not normal, adjust according to the separate volume “DV
commander. (Whenever you want to quit the record mode, be
MECHANICAL ADJUSTMENT MANUAL Z Mechanism ”.
sure to quit following this procedure.)
CN1018 of VC-319 board
2-2. HOW TO ENTER PLAYBACK MODE WITHOUT
CASSETTE Pin No. Signal Name Pin No. Signal Name
1) Connect the adjustment remote commander to the LANC jack. 1 MS BS 2 D 2.8V
2) Turn the HOLD switch of the adjustment remote commander 3 MS DIO 4 MS XIN
to the ON position. 5 MS SCLK 6 REG GND
3) Close the cassette compartment without the cassette. 7 MD2 8 XCS MC FLASH
4) Select page: 3, address: 01, and set data: 0B, and press the
9 XSYS RST 10 EEP SI
PAUSE button of the adjustment remote commander.
(The mechanism enters the playback mode automatically.) 11 EEP SO 12 EEP SCK
Note: The function buttons becomes inoperable. 13 REC CRRT1 14 REC CRRT0
5) To quit the playback mode, select page: 3, address: 01, set data: 15 MS LED ON 16 MS VCC
00, and press the PAUSE button of the adjustment remote 17 SWP 18 FRRV
commander. (Whenever you want to quit the playback mode,
19 REG GND 20 RF MON
be sure to quit following this procedure.)
Table. 6-2-1.

2. Processing after Completing Operations:


1) Connect the adjustment remote commander to the LANC jack
and set the HOLD switch to the ON position.
2) Select page: 3, address: 26, and set data: 00, and press PAUSE
button.
3) Select page: 3, address: 33, and set data: 00.

Entrance Check this section Exit side


side (Normal waveform)

CH1

CH2
(Trigger)

3.3 msec

Fig. 6-2-1.

6-44
DCR-PC103E/PC104E/PC105/PC105E

COVER

6-3. VIDEO SECTION ADJUSTMENT


3-1. PREPARATIONS BEFORE ADJUSTMENTS

Use the following measuring instruments for video section


adjustments.

3-1-1. Equipment to Required

1) TV monitor
2) Oscilloscope (dual-phenomenon, band width above 30 MHz
with delay mode) (Unless specified otherwise, use a 10 : 1
probe.)
3) Frequency counter
4) Pattern generator with video output terminal
5) Digital voltmeter
6) Audio generator
7) Audio level meter
8) Audio distortion meter
9) Audio attenuator
10) Regulated power supply
11) Alignment tapes
• Tracking standard (XH2-1)
Parts code: 8-967-997-01
• SW/OL standard (XH2-3)
Parts code: 8-967-997-11
• Audio operation check for NTSC (XH5-3)
Parts code: 8-967-997-51
• System operation check for NTSC (XH5-5)
Parts code: 8-967-997-61
• Audio operation check for PAL (XH5-3P)
Parts code: 8-967-997-55
• System operation check for PAL (XH5-5P)
Parts code: 8-967-997-66
12) Adjustment remote commander (J-6082-053-B)
13) CPC-6 flexible jig (J-6082-370-C)
14) CPC-6 terminal board jig (J-6082-371-A)

6-45
DCR-PC103E/PC104E/PC105/PC105E

3-1-2. Precautions on Adjusting Note2: Setting the “Forced VTR Power ON” mode (VTR mode)
Note1: Before performing the adjustments, check the data of page: 0, 1) Select page: 0, address: 01, and set data: 01.
address: 10 is “00”. If not, set data: 00 to this address. 2) Select page: D, address: 10, set data: 02, and press the PAUSE
1) The adjustments of this unit are performed in the VTR mode button of the adjusting remote commander.
or camera mode. The above procedure will enable the VTR power to be turned on
with the control switch block (PS4400 block) removed.
To set to the VTR mode, set the power switch to “VCR” (or
After completing adjustments, be sure to exit the “Forced Power
“PLAYER”) or set the “Forced VTR Power ON mode” using ON mode”.
the adjusting remote commander (Note2). Note3: Setting the “Forced Camera Power ON” mode (Camera mode)
To set to the Camera mode, set the power switch to “CAMERA” 1) Select page: 0, address: 01, and set data: 01.
or set the “Forced Camera Power ON mode” using the adjusting 2) Select page: D, address: 10, set data: 01, and press the PAUSE
remote commander (Note3). button of the adjusting remote commander.
After completing adjustments, be sure to exit the “Forced VTR The above procedure will enable the camera power to be turned
Power ON Mode” or “Forced Camera Power ON Mode”. on with the control switch block (PS4400 block) removed.
After completing adjustments, be sure to exit the “Forced Power
(Note5)
ON mode”.
2) Only for DCR-PC105/PC105E model, short-circuit between Note4: Setting the “Forced Memory Power ON” mode (Memory mode)
the xenon tube anode of the flash unit (FL4400) and the GND (DCR-PC105/PC105E)
(GND of the accessory shoe) with the short jig about 10 seconds 1) Select page: 0, address: 01, and set data: 01.
and discharge the flash power supply capacitor. (Refer to 2) Select page: D, address: 10, set data: 05, and press the PAUSE
“SERVICE NOTE”.) button of the adjusting remote commander.
3) To remove the cabinet (R), disconnect the following connector. The above procedure will enable the memory power to be turned
VC-319 board CN1012 (60P, 0.4mm) on with the control switch block (PS4400 block) removed.
After completing adjustments, be sure to exit the “Forced Power
As the DC IN jack is attached to the BJ-004 board of the cabinet
ON mode”.
(R), the board must be connected to the VC-319 board. So Note5: Exiting the “Forced Power ON” mode
remove the BJ-004 board from the cabinet (R). To remove the 1) Select page: 0, address: 01, and set data: 01.
board from the cabinet (R), disconnect the following connectors. 2) Select page: D, address: 10, set data: 00, and press the PAUSE
(The LCD block needs not to be connected. To operate VTR, button of the adjusting remote commander.
use the adjustment remote commander.) 3) Select page: 0, address: 01, and set data: 00.
1. BJ-004 board CN5804 (6P, 0.5mm) Note6: When the flash error code (E: 91: ** ) is displayed. After
2. BJ-004 board CN5803 (20P, 0.8mm) completing adjustments, clear the error flag. (Refer to “Record of
Self-diagnosis check” of “6-4. SERVICE MODE”.)
And connect the BJ-004 board to the following connector of
VC-319 board.
VC-319 board CN1012 (60P, 0.4mm)
4) The ST-084 board is need not be connected. To remove it,
disconnect the following connector. (DCR-PC105/PC105E)
(Note6)
VC-319 board CN1010 (16P, 0.5mm)
5) The lens block (CD-444 board) is need not be connected. To
remove it, disconnect the following connectors.
VC-319 board CN1011 (40P, 0.4mm)
VC-319 board CN1013 (27P, 0.3mm)
6) By setting the “Forced VTR Power ON mode”, the video section
can be operate even if the control switch block (PS4400) has
been removed. When removing it, disconnect the following
connector.
VC-319 board CN1009 (10P, 0.5mm)
7) The NS-018 board is need not be connected. To remove it,
disconnect the following connector.
VC-319 board CN1016 (8P, 0.5mm)
8) Removing the CN1019 of the VC-319 board (removing the
control switch block (FK4400)) means removing the lithium
3V power supply (LI-070 board, BT6401), data such as date,
time, user-set menus will be lost. After completing adjustments,
reset these data.
But, the self-diagnosis data and the data on history of use (total
drum rotation time etc.) will be kept even if the CN1019 has
been removed. (Refer to “6-4. Service Mode” for the data on
the history use and the self-diagnosis data.)

6-46
DCR-PC103E/PC104E/PC105/PC105E

3-1-3. Adjusting Connectors


The measuring point of the playback RF signal is CN1018 of VC-
319 board. Connect the measuring instruments via the CPC-6
flexible jig (J-6082-370-C) and CPC-6 terminal board jig (J-6082-
371-A). Refer to “MECHANISM SECTION ADJUSTMENT” for
the measuring method. The following table lists the pin numbers
and signal names of CN1018.
Pin No. Signal Name Pin No. Signal Name CN1018
1 MS BS 2 D 2.8V 19 20
3 MS DIO 4 MS XIN
5 MS SCLK 6 REG GND
1 2
7 MD2 8 XCS MC FLASH
9 XSYS RST 10 EEP SI
11 EEP SO 12 EEP SCK
13 REC CRRT1 14 REC CRRT0
15 MS LED ON 16 MS VCC
17 SWP 18 FRRV
19 REG GND 20 RF MON
Table 6-3-1. Fig. 6-3-1.

3-1-4. Connecting the Equipment


Connect the measuring instruments as shown in Fig. 6-3-2, and
perform the adjustments.

TV monitor

VIDEO
(Yellow)
Main unit
AUDIO L (White)
Adjustment
remote
commander
AUDIO R (Red)
LANC jack AUDIO/VIDEO jack

Fig. 6-3-2.

6-47
DCR-PC103E/PC104E/PC105/PC105E

3-1-5. Alignment Tapes


Use the alignment tapes shown in the following table.
Use tapes specified in the signal column of each adjustment.
Name Use
Tracking standard (XH2-1) Tape path adjustment
SW/OL standard (XH2-3) Switching position adjustment
Audio operation check
Audio system adjustment
(XH5-3 (NTSC), XH5-3P (PAL))
System operation check
Operation check
(XH5-5 (NTSC), XH5-5P (PAL))

Fig. 6-3-3. shows the 75% color bar signals recorded on the
alignment tape for Audio Operation Check.

Note: Measure with video terminal (Terminated at 75 Ω)

For NTSC model


White (100%)
Yellow

Cyan

Magenta
Green

White (75%)

Magenta
Red

White
Blue

Burst signal

Yellow

Green
Cyan

Red

Blue
0.714V
(75%)
1V
0.286V
0.286V Q I Black
Q I

White
(100%)
Horizontal sync signal
Color bar signal waveform Color bar pattern

For PAL model


White (100%)
Yellow

Green
Cyan

Magenta
Red
Blue

0.7V
Magenta
Green
Yellow

1V
Cyan
White

Red
Blue
Black

0.3V
0.3V (100%)

Burst signal
Horizontal sync signal

Color bar signal waveform Color bar pattern

Fig. 6-3-3. Color bar signal of alignment tapes

3-1-6. Input/Output Level and Impedance


Video input/output Audio input/output
Special stereo mini jack Special stereo mini jack
Video signal: 1 Vp-p, 75 Ω unbalanced, Input level: 327mV
sync negative Input impedance: More than 47kΩ
S video input/output Output level: 327 mV (at load impedance 47 kΩ)
4-pin mini DIN Output impedance: Below 2.2 kΩ
Luminance signal: 1 Vp-p, 75 Ω unbalanced,
sync negative
Chrominance signal: 0.286 Vp-p, 75 Ω unbalanced (NTSC)
: 0.300 Vp-p, 75 Ω unbalanced (PAL)

6-48
DCR-PC103E/PC104E/PC105/PC105E

COVER

3-2. SYSTEM CONTROL SYSTEM ADJUSTMENT 3-2. Serial No. Input


Write the serial No. and model code in the EEPROM (nonvolatile
1. Initialization of 8, A, B, C, D, E, F, 18, 1B, 1C, 1E, 1F memory). Convert the serial No. on the name plate from decimal to
Page Data hexadecimal, and write in the EEPROM.
If the 8, A, B, C, D, E, F, 18, 1B, 1C, 1E, 1F page data is erased Page C
due to some reason, perform “1-2. INITIALIZATION OF 8, A, B, Address E5, E6, E7
C, D, E, F, 18, 1B, 1C, 1E, 1F PAGE DATA” of “6-1. CAMERA
SECTION ADJUSTMENT” Note: The data of page: 0, address: 10 must be “00”.
Note: When reading or writing the 18, 1B, 1C, 1E, 1F page data, select
page: 0, address: 10, and set data: 01, then select 8, B, C, E or F
Input method:
page. The 18, 1B, 1C, 1E or 1F page can be chosen by this data
setting. 1) Select page: 0, address: 01, and set data: 01.
After reading or writing, reset the data of page: 0, address: 10 to 2) Read the serial No. on the name plate, and take it as D1.
“00”. Example: If the serial No. is 77881.
D1 = 77881
2. Touch Panel Adjustment Note: Use six digits of the low rank when a serial No. is more than
Adjust the calibration of the touch panel. seven digits.
3) Obtain D2 and H1 corresponding to D1 from Table 6-3-2.
Mode VTR stop
Example: If D1 is “77881”.
Signal Arbitrary D2 = D1 – 65536 = 12345
Adjustment Page A H1 = FE
Adjustment Address 90 to 93 H1 (Hexadecimal)
D1 (Decimal) D2 (Decimal)
(Service model code)
Note1: Perform this adjustment with observing the screen from the front. 000001 to 065535 D1 FE
Note2: The data of page: 0, address: 10 must be “00”.
065536 to 131071 D1 – 65536 FE
Adjusting method: 131072 to 196607 D1 – 131072 FE
1) Select page: 7, address: 05, and set data: 01. Table. 6-3-2.
2) Using a stylus, push the center of “X” indicated in the part A. 4) Input H1 to page: C, address: E5. (Model code input)
3) Using a stylus, push the center of “X” indicated in the part B. Example: If H1 is “FE”.
4) Using a stylus, push the center of “X” indicated in the part C. Select page: C, address: E5, set data: FE, and
5) Select page: 7, address: 05, and check that the data is “00”. press the PAUSE button.
5) Obtain the maximum decimal not exceeding D2 from Table 6-
3-3, and take this as D3.
Example: If D2 is “12345”.
A D3 = 12288
C
6) Obtain the hexadecimal corresponding to D3 from Table 6-3-
3, and take this as H3.
Example: If D3 is “12288”.
H3 = 3000
7) Obtain the difference D 4 between D 2 and D 3. (Decimal
B
calculation, 0 D4 255)
D4 = D2 – D3
Example: If D2 is “12345” and D3 is “12288”.
Fig. 6-3-4. D4 = 12345 – 12288 = 57
8) Convert D4 to hexadecimal, and take this as H4.
3. Serial No. Input (Refer to “Hexadecimal-decimal conversion table” in “6-4.
3-1. Company ID Input Service Mode”.)
Write the company ID in the EEPROM (nonvolatile memory). Example: If D4 is “57”.
H4 = 39
Page C
9) Input the upper 2 digits of H3 to page: C, address: E6.
Address E0, E1, E2, E3, E4 Example: If H3 is “3000”.
Select page: C, address: E6, set data: 30, and
Note: The data of page: 0, address: 10 must be “00”.
press the PAUSE button.
10) Input H4 to page: C, address: E7.
Input method:
Example: If H4 is “39”.
1) Select page: 0, address: 01, and set data: 01.
Select page: C, address: E7, set data: 39, and
2) Input the following data to page: C, addresses: E0 to E4.
press the PAUSE button.
Note: Press the PAUSE button of the adjustment remote commander
each time to set the data.
11) Select page: 0, address: 01, and set data: 00.

Address Data
E0 08
E1 00
E2 46
E3 01
E4 02
3) Select page: 0, address: 01, and set data: 00.
6-49
DCR-PC103E/PC104E/PC105/PC105E

Hexa- Hexa- Hexa- Hexa- Hexa- Hexa- Hexa- Hexa-


Decimal decimal Decimal decimal Decimal decimal Decimal decimal Decimal decimal Decimal decimal Decimal decimal Decimal decimal
(D3) (H3) (D3) (H3) (D3) (H3) (D3) (H3) (D3) (H3) (D3) (H3) (D3) (H3) (D3) (H3)
0 0000 8192 2000 16384 4000 24576 6000 32768 8000 40960 A000 49152 C000 57344 E000
256 0100 8448 2100 16640 4100 24832 6100 33024 8100 41216 A100 49408 C100 57600 E100
512 0200 8704 2200 16896 4200 25088 6200 33280 8200 41472 A200 49664 C200 57856 E200
768 0300 8960 2300 17152 4300 25344 6300 33536 8300 41728 A300 49920 C300 58112 E300
1024 0400 9216 2400 17408 4400 25600 6400 33792 8400 41984 A400 50176 C400 58368 E400
1280 0500 9472 2500 17664 4500 25856 6500 34048 8500 42240 A500 50432 C500 58624 E500
1536 0600 9728 2600 17920 4600 26112 6600 34304 8600 42496 A600 50688 C600 58880 E600
1792 0700 9984 2700 18176 4700 26368 6700 34560 8700 42752 A700 50944 C700 59136 E700
2048 0800 10240 2800 18432 4800 26624 6800 34816 8800 43008 A800 51200 C800 59392 E800
2304 0900 10496 2900 18688 4900 26880 6900 35072 8900 43264 A900 51456 C900 59648 E900
2560 0A00 10752 2A00 18944 4A00 27136 6A00 35328 8A00 43520 AA00 51712 CA00 59904 EA00
2816 0B00 11008 2B00 19200 4B00 27392 6B00 35584 8B00 43776 AB00 51968 CB00 60160 EB00
3072 0C00 11264 2C00 19456 4C00 27648 6C00 35840 8C00 44032 AC00 52224 CC00 60416 EC00
3328 0D00 11520 2D00 19712 4D00 27904 6D00 36096 8D00 44288 AD00 52480 CD00 60672 ED00
3584 0E00 11776 2E00 19968 4E00 28160 6E00 36352 8E00 44544 AE00 52736 CE00 60928 EE00
3840 0F00 12032 2F00 20224 4F00 28416 6F00 36608 8F00 44800 AF00 52992 CF00 61184 EF00
4096 1000 12288 3000 20480 5000 28672 7000 36864 9000 45056 B000 53248 D000 61440 F000
4352 1100 12544 3100 20736 5100 28928 7100 37120 9100 45312 B100 53504 D100 61696 F100
4608 1200 12800 3200 20992 5200 29184 7200 37376 9200 45568 B200 53760 D200 61952 F200
4864 1300 13056 3300 21248 5300 29440 7300 37632 9300 45824 B300 54016 D300 62208 F300
5120 1400 13312 3400 21504 5400 29696 7400 37888 9400 46080 B400 54272 D400 62464 F400
5376 1500 13568 3500 21760 5500 29952 7500 38144 9500 46336 B500 54528 D500 62720 F500
5632 1600 13824 3600 22016 5600 30208 7600 38400 9600 46592 B600 54784 D600 62976 F600
5888 1700 14080 3700 22272 5700 30464 7700 38656 9700 46848 B700 55040 D700 63232 F700
6144 1800 14336 3800 22528 5800 30720 7800 38912 9800 47104 B800 55296 D800 63488 F800
6400 1900 14592 3900 22784 5900 30976 7900 39168 9900 47360 B900 55552 D900 63744 F900
6656 1A00 14848 3A00 23040 5A00 31232 7A00 39424 9A00 47616 BA00 55808 DA00 64000 FA00
6912 1B00 15104 3B00 23296 5B00 31488 7B00 39680 9B00 47872 BB00 56064 DB00 64256 FB00
7168 1C00 15360 3C00 23552 5C00 31744 7C00 39936 9C00 48128 BC00 56320 DC00 64512 FC00
7424 1D00 15616 3D00 23808 5D00 32000 7D00 40192 9D00 48384 BD00 56576 DD00 64768 FD00
7680 1E00 15872 3E00 24064 5E00 32256 7E00 40448 9E00 48640 BE00 56832 DE00 65024 FE00
7936 1F00 16128 3F00 24320 5F00 32512 7F00 40704 9F00 48896 BF00 57088 DF00 65280 FF00
Table. 6-3-3.

6-50
DCR-PC103E/PC104E/PC105/PC105E

COVER

3-3. SERVO AND RF SYSTEM ADJUSTMENT 2. Switching Position Adjustment (VC-319 Board)
Before perform the servo and RF system adjustments, check that
the specified value of “54 MHz/66 MHz Origin Oscillation To obtain normal playback waveform output during the playback
Adjustment” of “CAMERA SYSTEM ADJUSTMENT” is satisfied. mode, adjust the switching position.
And check that the data of page: 0, address: 10 is “00”. If not, set Mode VTR playback
data: 00 to this address. Signal SW/OL reference tape (XH2-3)
Adjusting Procedure: Measurement Point Display data of page: 3, address: 02, 03
1. CAP FG duty adjustment Measuring Instrument Adjustment remote commander
2. Switching position adjustment Adjustment Page C
3. Error rate check
Adjustment Address 10, 11, 12, 13
1. Cap FG Duty Adjustment (VC-319 Board) Specified Value Data of page: 3, address: 02 is “00”.
Set the Cap FG signal duty cycle to 50% to establish an appropriate Data of page: 3, address: 03 is “00”.
capstan servo. If deviated, the uneven rotation of capstan and noise
can occur. Note1: The data of page: 0, address: 10 must be “00”.

Measurement Point Display data of page: 3, address: 02, 03 Adjusting method:


Measuring Instrument Adjustment remote commander Order Page Address Data Procedure
Adjustment Page C 1 Insert the SW/OL reference tape
Adjustment Address 16 and enter the VTR STOP mode.
Specified Value Data of page: 3, address: 02 is “00”. 2 0 01 01 Set the data.
Data of page: 3, address: 03 is “00”. 3 C 10 EE Set the data, and press PAUSE
button.
Note1: The data of page: 0, address: 10 must be “00”.
4 3 21 Check that the data is “02”.
Adjusting method: (Note2)
Order Page Address Data Procedure 5 3 01 0D Set the data, and press PAUSE
button.
1 Close the cassette compartment
without inserting a cassette. 6 3 02 Check that the data changes to
“00”.
2 0 01 01 Set the data.
7 3 03 Check that the data is “00”.
3 3 01 1B Set the data, and press PAUSE
(Note3)
button.
8 0 01 00 Set the data.
4 3 02 Check that the data changes in
the following order.
Note2: If the data of page: 3, address: 21 is “72”, the tape top being played.
“1B” → “2B” → “00” After playing the tape for 1 to 2 seconds, stop it, perform step 5
5 3 03 Check that the data is “00”. and higher.
(Note2) If the data of page: 3, address: 21 is “62”, the tape end being played.
After rewinding the tape, perform step 5 and higher.
6 0 01 00 Set the data. Note3: If bit 0 of the data is “1”, the EVEN channel is defective. If bit 1 is
“1”, the ODD channel is defective. Contents of the defect is written
Note2: If the data is “01”, adjustment has errors or the mechanism deck is into page: C, addresses: 10 and 12. See the following table. (For
defective. the bit values, refer to “6-4. SERVICE MODE”, “4-3. 3. Bit value
discrimination”. ) If bit 3 of the data is “1”, the tape end being
played, so rewind the tape and perform the adjustment again.

When the EVEN channel is defective


Data of page: C,
Contents of defect
address: 10
EE Writing into EEPROM (IC2602) is defective
E8 Adjustment data is out of range
E7 No data is returned from IC2301

When the ODD channel is defective


Data of page: C,
Contents of defect
address: 12
EE Writing into EEPROM (IC2602) is defective
E8 Adjustment data is out of range
E7 No data is returned from IC2301

6-51
DCR-PC103E/PC104E/PC105/PC105E

3. Error Rate Check


Initial Value of Page 1C: Address: B3 to C8
3-1. Preparations before adjustments Address Initial Address Initial Address Initial
Mode Camera recording value value value
Subject Arbitrary B3 00 BB 00 C3 80
B4 00 BC 00 C4 00
Adjusting method: B5 00 BD 00 C5 00
Order Page Address Data Procedure B6 00 BE 00 C6 00
1 0 01 01 Set the data. B7 00 BF 00 C7 00
2 0 10 01 Set the data. B8 80 C0 00 C8 00
3 C 0D C8 Set the data, and press PAUSE B9 00 C1 00
button. BA 00 C2 00
4 0 10 00 Set the data.
Table 6-3-4.
5 Record the camera signal for
two minutes. Note4: When writing the 1C page data, select page: 0, address: 10, and
set data: 01, then select C page.
3-2. Error Rate Check After writing the initial values, reset the data of page: 0, address:
10 to “00”.
Mode Playback
Signal Recorded signal at “Preparations 3-3. Processing after Completing Adjustments
before adjustments”
Order Page Address Data Procedure
Measurement Point Display data of page: 3, address: 02, 03
1 0 01 01 Set the data.
Measuring Instrument Adjustment remote commander
2 0 10 01 Set the data.
Adjustment Page 1C (Note1)
3 C 0D 00 Set the data, and press PAUSE
Adjustment Address B3 to C8 button.
Specified Value Data of page: 3, address: 02 is “00”. 4 0 01 00 Set the data.
Data of page: 3, address: 03 is “00”.
5 0 10 00 Set the data.
Note1: When reading or writing the 1C page data, select page: 0, address:
10, and set data: 01, then select C page. The 1C page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.

Adjusting method:
Order Page Address Data Procedure
1 Playback the recorded signal at
“Preparations before
adjustments”
2 0 01 01 Set the data.
3 0 10 00 Set the data.
4 3 1D Check that the data is “20”.
5 3 01 40 Set the data, and press PAUSE
button.
6 3 02 Check that the data changes
from “40” to “00”.
7 3 03 Check that the data is “00”.
(Note2)
8 Perform “Processing after
Completing Adjustments”

Note2: If the data is other than “00”, Error rate is abnormal.


For the contents of the abnormality, see the following table.

Data of page: 3, Contents of the abnormality


address: 03
01 ODD ch is abnormal.
02 EVEN ch is abnormal.
03 EVEN ch and ODD ch are abnormal.
Note3: If Error rate is abnormal, Check the use tape, clean the tape running
surface. And after inputting initial values to page 1C: address: B3
to C8, perform re-adjustment. (See Table 6-3-4.)

6-52
DCR-PC103E/PC104E/PC105/PC105E

COVER

3-4. VIDEO SYSTEM ADJUSTMENTS 2. S VIDEO OUT Chroma Level Adjustment


Note1: Before perform the servo and RF system adjustments, check that (VC-319 Board)
the specified value of “54 MHz/66 MHz Origin Oscillation
Adjustment” of “CAMERA SYSTEM ADJUSTMENT” is satisfied.
Mode Camera
And check that the data of page: 0, address: 10 is “00”. If not, set
data: 00 to this address. Subject Arbitrary
Measurement Point Chroma signal terminal of S VIDEO
Note2: NTSC model: DCR-PC105
jack (75Ω terminated)
PAL model: DCR-PC103E/PC104E/PC105E
External trigger: Y signal terminal of S
VIDEO jack
1. S VIDEO OUT Y Level Adjustment (VC-319 Board)
Measuring Instrument Oscilloscope
Mode Camera Adjustment Page C
Subject Arbitrary Adjustment Address 26, 27
Measurement Point Y signal terminal of S VIDEO jack Specified Value Cr level: A = 714 ± 14mV (NTSC)
(75Ω terminated) A = 700 ± 14mV (PAL)
Cb level: B = 714 ± 14mV (NTSC)
Measuring Instrument Oscilloscope
B = 700 ± 14mV (PAL)
Adjustment Page C Burst level: C = 286 ± 6mV (NTSC)
Adjustment Address 25 C = 300 ± 6mV (PAL)
Specified Value A = 1000 ± 14mV
Note: The data of page: 0, address: 10 must be “00”.
Note: The data of page: 0, address: 10 must be “00”.
Switch setting:
Switch setting: DEMO MODE (Menu setting) ........................................ OFF
DEMO MODE (Menu setting) ........................................ OFF
Adjusting method:
Adjusting method: Order Page Address Data Procedure
Order Page Address Data Procedure 1 0 01 01 Set the data.
1 0 01 01 Set the data. 2 3 0C 02 Set the data, and press PAUSE
2 3 0C 02 Set the data, and press PAUSE button.
button. 3 C 26 Change the data and set the Cr signal
3 C 25 Change the data and set the Y level (A) to the specified value.
signal level (A) to the specified 4 C 26 Press PAUSE button.
value. 5 C 27 Change the data and set the Cb signal
4 C 25 Press PAUSE button. level (B) to the specified value.
5 3 0C 00 Set the data, and press PAUSE 6 C 27 Press PAUSE button.
button. 7 Check that the burst signal level
6 0 01 00 Set the data. (C) is satisfied the specified value.
8 3 0C 00 Set the data, and press PAUSE
button.
9 0 01 00 Set the data.

Fig. 6-3-5.

A B

0.28 µsec (NTSC) 0.28 µsec (NTSC)


0.23 µsec (PAL) 0.23 µsec (PAL)
Fig. 6-3-6.

6-53
DCR-PC103E/PC104E/PC105/PC105E

3. VIDEO OUT Y, Chroma Level Check (VC-319 Board)

Mode Camera
Subject Arbitrary
Measurement Point Video terminal of AUDIO VIDEO jack
(75Ω terminated)
Measuring Instrument Oscilloscope
Specified Value Sync level: A = 286 ± 18mV (NTSC)
A = 300 ± 18mV (PAL)
Burst level: B = 286 ± 18mV (NTSC)
B = 300 ± 18mV (PAL)

Note: The data of page: 0, address: 10 must be “00”.

Switch setting:
DEMO MODE (Menu setting) ........................................ OFF

Adjusting method:
Order Page Address Data Procedure
1 3 0C 02 Set the data, and press PAUSE
button.
2 Check that the sync signal level
(A) satisfies the specified value.
3 Check that the burst signal level
(B) satisfies the specified value.
4 3 0C 00 Set the data, and press PAUSE
button.

B
A

Fig. 6-3-7.

6-54
DCR-PC103E/PC104E/PC105/PC105E

COVER

3-5. AUDIO SYSTEM ADJUSTMENTS

[Connection of Audio System Measuring Devices]


Connect the audio system measuring devices as shown in Fig. 6-3-8.

Recording (Camera mode) Main unit

MIC
Audio oscillator 600 Ω Left

Attenuator Right

600 Ω: 270 Ω (1-249-410-11) + 330 Ω (1-249-411-11)

Playback
Main unit
TV monitor
Video (Yellow)

Left (White)
Audio level meter
AUDIO/ 47k Ω or Distortion meter
VIDEO Right
OUT
(Red) 47k Ω

47k Ω (1-249-437-11)

Fig. 6-3-8.

6-55
DCR-PC103E/PC104E/PC105/PC105E

1. Playback Level Check 4. Overall Noise Level Check


Mode VTR playback Mode Camera recording and playback
Signal Alignment tape: Signal No signal: Insert a shorting plug in the
For audio operation check MIC jack
(XH5-3 (NTSC)) Measurement Point Audio left or right terminal of
(XH5-3P (PAL)) AUDIO/VIDEO jack
Measurement Point Audio left or right terminal of Measuring Instrument Audio level meter
AUDIO/VIDEO jack
Specified Value Below –45dBs
Measuring Instrument Audio level meter and frequency (IHF-A filter ON, 20kHz LPF ON)
counter
Specified Value 32 kHz mode: 1 kHz, +3.0 ± 2.0dBs Checking Method:
48 kHz mode: 1 kHz, +3.0 ± 2.0dBs 1) Insert a shorting plug in the MIC jack.
44.1 kHz mode: 2) Record in the camera mode.
The 7.35kHz signal level during EMP 3) Playback the recorded section.
OFF is +2.0 ± 2.0dBs. 4) Check that the noise level is the specified value.
The 7.35kHz signal level during EMP
ON is –6 ± 2 dB from the signal level
during EMP OFF. 5. Overall Separation Check
Mode Camera recording and playback
Checking Method:
Signal 400Hz, –66dBs signal: MIC jack
1) Check that the playback signal level is the specified value.
<right> [left]
(Connect the MIC jack <left> [right]
to GND)
2. Overall Level Characteristics Check
Measurement Point Audio <left> [right] terminal of
Mode Camera recording and playback
AUDIO VIDEO jack
Signal 400Hz, –66 dBs signal: MIC jack left
Measuring Instrument Audio level meter
and right
Specified Value Below –40dBs (IHF-A filter ON)
Measurement Point Audio left or right terminal of
AUDIO/VIDEO jack
< > : Left channel check
Measuring Instrument Audio level meter [ ] : Right channel check
Specified Value –7.5 ± 3.0dBs
Checking Method:
Checking Method: 1) Input the 400Hz, –66dBs signal in the <right> [left] terminal
1) Input the 400Hz, –66dBs signal in the MIC jack. of the MIC jack only.
2) Record in the camera mode. 2) Record in the camera mode.
3) Playback the recorded section. 3) Playback the recorded section.
4) Check that the 400Hz signal level is the specified value. 4) Check that the signal level of the audio <left> [right] terminal
is the specified value.

3. Overall Distortion Check


Mode Camera recording and playback
Signal 400Hz, –66dBs signal: MIC jack left
and right
Measurement Point Audio left or right terminal of
AUDIO/VIDEO jack
Measuring Instrument Audio distortion meter
Specified Value Below 0.4%
(200Hz to 6kHz BPF ON)

Checking Method:
1) Input the 400Hz, –66dBs signal in the MIC jack.
2) Record in the camera mode.
3) Playback the recorded section.
4) Check that the distortion is the specified value.

6-56
DCR-PC103E/PC104E/PC105/PC105E

COVER

6-4. SERVICE MODE


4-1. ADJUSTMENT REMOTE COMMANDER 2. Precautions upon using
The adjustment remote commander is used for changing the the adjustment remote commander
calculation coefficient in signal processing, EVR data, etc. The Mishandling of the adjustment remote commander may erase the
adjustment remote commander performs bi-directional correct adjustment data at times. To prevent this, it is recommended
communication with the unit using the remote commander signal that all adjustment data be noted down before beginning adjustments
line (LANC). The resultant data of this bi-directional communication and new adjustment data after each adjustment.
is written in the non-volatile memory.

1. Using the adjustment remote commander


1) Connect the adjustment remote commander to the LANC
terminal.
2) Set the HOLD switch of the adjustment remote commander to
“HOLD” (SERVICE position). If it has been properly
connected, the LCD on the adjustment remote commander will
display as shown in Fig. 6-4-1.

Page Data Address

Fig. 6-4-1

3) Operate the adjustment remote commander as follows.


• Changing the page
The page increases when the EDIT SEARCH+ button is pressed,
and decreases when the EDIT SEARCH– button is pressed. There
are altogether 21 pages, from 0 to F, 18, 1B, 1C, 1E, 1F. (Note)
Hexadecimal
notation 0 1 2 3 4 5 6 7 8 9 A B C D E F
LCD Display 0 1 2 3 4 5 6 7 8 9 A b c d E F
Decimal notation
conversion value 0 1 2 3 4 5 6 7 8 9 1011 12 1314 15

• Changing the address


The address increases when the FF (M) button is pressed,
and decreases when the REW (m) button is pressed. There
are altogether 256 addresses, from 00 to FF.
• Changing the data (Data setting)
The data increases when the PLAY (N) button is pressed,
and decreases when the STOP (x) button is pressed. There
are altogether 256 data, from 00 to FF.
• Writing the adjustment data
The PAUSE button must be pressed to write the adjustment
data (8, A, B, C, D, E, F, 18, 1B, 1C, 1E, 1F page) in the
nonvolatile memory. (The new adjusting data will not be
recorded in the nonvolatile memory if this step is not
performed.)
4) After completing all adjustments, turn off the main power
supply once.

Note: When reading or writing the 18, 1B, 1C, 1E, 1F page data, select
page: 0, address: 10, and set data: 01, then select 8, B, C, E or F
page. The 18, 1B, 1C, 1E or 1F page can be chosen by this data
setting.
After reading or writing, reset the data of page: 0, address: 10
to “00”.

6-57
DCR-PC103E/PC104E/PC105/PC105E

COVER

4-2. DATA PROCESS


The calculation of the DDS display and the adjustment remote
commander display data (hexadecimal notation) are required for
obtaining the adjustment data of some adjustment items. In this case,
after converting the hexadecimal notation to decimal notation,
calculate and convert the result to hexadecimal notation, and use it
as the adjustment data. Indicates the hexadecimal-decimal
conversion table.

Hexadecimal-decimal Conversion Table 2


Lower digit of
hexadecimal 0 1 2 3 4 5 6 7 8 9 A B C D E F
Upper digit (A) (b) (c) (d) (E) (F)
of hexadecimal
0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
1 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
2 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47
3 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63
4 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79
5 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95
6 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111
7 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127
8 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143
9 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159
A (A) 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175
1 B (b) 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191
C (c) 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207
D (d) 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223
E (E) 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239
F (F) 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255
Note: The characters shown in the parenthesis ( ) shown the display on the adjustment remote commander.
(Example) If the DDS display or the adjustment remote commander shows BD (bd);
Because the upper digit of the adjustment number is B (b), and the lower digit is D (d), the meeting point
“189” of 1 and 2 in the above table is the corresponding decimal number.

Table. 6-4-1.

6-58
DCR-PC103E/PC104E/PC105/PC105E

COVER

4-3. SERVICE MODE

Note: Before performing the adjustments, check the data of page: 0,


address: 10 is “00”. If not, set data: 00 to this address.

1. Setting the Test Mode 2-1. EMG Code (Emergency Code)


Page D Address 10 Codes corresponding to the errors which occur are written in
addresses F4, F8 and FC. The type of error indicated by the code
are shown in the following table.
Data Function
00 Normal Code Emergency Type
01 Forced camera power ON 00 No error
02 Forced VTR power ON 10 Loading motor emergency during loading
03 Forced camera + VTR power ON 11 Loading motor emergency during unloading
05 Forced memory power ON 22 T reel emergency during normal rotation
23 S reel emergency during normal rotation
• Before setting the data , select page: 0, address: 01, and set data: 01. T reel emergency (Short circuit between S reel
• For page D, the data set is recorded in the non-volatile memory 24
terminal and T reel terminal)
by pressing the PAUSE button of the adjustment remote 30 FG emergency at the start up of the capstan
commander. In this case, take note that the test mode will not be
40 FG emergency at the start up of the drum
exited even when the main power is turned off.
• After completing adjustments/repairs, be sure to return the data 42 FG emergency during normal rotation of the drum
of this address to 00, and press the PAUSE button of the adjustment
remote commander.
Select page: 0, address: 01, and set data: 00.

2. Emergence Memory Address


Page C Address F4 to FF

Address Contents
F4 EMG code when first error occurs
Upper: MSW code when shift starts when first
F6 error occurs
Lower: MSW code when first error occurs
Lower: MSW code to be moved when first error
F7
occurs
F8 EMG code when second error occurs
Upper: MSW code when shift starts when second
FA error occurs
Lower: MSW code when second error occurs
Lower: MSW code to be moved when second error
FB
occurs
FC EMG code when last error occurs
Upper: MSW code when shift starts when last error
FE occurs
Lower: MSW code when last error occurs
Lower: MSW code to be moved when last error
FF
occurs

When no error occurs in this unit, data “00” is written in the above
addresses (F4 to FF). when first error occurs in the unit, the data
corresponding to the error is written in the first emergency address
(F4 to F7). In the same way, when the second error occurs, the data
corresponding to the error is written in the second emergency address
(F8 to FB). Finally, when the last error occurs, the data corresponding
to the error is written in the last emergency address (FC to FF).

Note: After completing adjustments, be sure to initialize the data of


addresses F4 to FF to “00”.

Initializing method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 01, set data: 37, and press the PAUSE
button.
3) Check that the data of page:3, address:02 is “00”.
4) Select page: 0, address: 01, and set data: 00.

6-59
DCR-PC103E/PC104E/PC105/PC105E

2-2. MSW Code


MSW when errors occur:
Information on MSW (mode SW) when errors occur
MSW when movement starts:
Information on MSW when movements starts when the mechanism position is moved (When the L motor is moved)
MSW of target of movement:
Information on target MSW of movement when the mechanism position is moved

Mechanical Position
← UNLOAD LOAD →
EJ BL ULE BL SR BL HL BL STOP BL R/P
← A (MSB)
0 1 0 0 = 4

0 1 1 0 = 6

0 0 1 0 = 2

1 0 1 0 = A

1 0 0 0 = 8

1 1 0 0 = C
1 1 1 0 = E

1 1 1 0 = E

1 1 1 0 = E

1 1 1 0 = E

1 1 1 0 = E
←B
←C
← D (LSB) (Fixed at “0”)

LS chassis movement section

Lock released Pinch roller pressing


Cassette compartment

Position Code Contents


Position at which the cassette component lock is released, at the farthest unload side mechanically
EJ 4
at which the mechanism can move no further in the UNLOAD direction.
BL E BLANK code, at the boundary between codes.
EJECT completion position. when the cassette is ejected, the mechanism will stop at this position.
ULE 6 Cassette IN standby. The guide will start protruding out as the mechanism moves towards the
LOAD position.
SR 2 Position at which it is possible to release the S ratchet.
HL A Guide loading are performed here.
Stop position in the loading state. The pinch roller separates, the tension regulator returns, and the
STOP 8
brake is imposed on both reels.
PB, REC, CUE, REVIEW, PAUSE, FF, REW positions. When pinch roller is pressed, and the tension
R/P C regulator is ON, the mechanism is operating at this position in modes in which normal images are
shown.
NULL 0 Code not existing in the MD. Default value.
F Status before finding any mechanism position.

6-60
DCR-PC103E/PC104E/PC105/PC105E

3. Bit value discrimination Display on the Bit values


Bit values must be discriminated using the display data of the adjustment bit3 bit2 bit1 bit0
adjustment remote commander for following items. Use the table remote or or or or
below to discriminate if the bit value is “1” or “0”. commander bit7 bit6 bit5 bit4
0 0 0 0 0
Display on the adjustment remote commander
1 0 0 0 1
2 0 0 1 0
3 0 0 1 1
4 0 1 0 0
5 0 1 0 1
Address 6 0 1 1 0
Page bit3 to bit0 discrimination 7 0 1 1 1
bit7 to bit4 discrimination A 8 1 0 0 0
9 1 0 0 1
A (A) 1 0 1 0
B (b) 1 0 1 1
C (c) 1 1 0 0
D (d) 1 1 0 1
B E (E) 1 1 1 0
F (F ) 1 1 1 1
Example: If “8E” is displayed on the adjustment remote commander, the
bit values for bit7 to bit4 are shown in the A column, and the
bit values for bit3 to bit0 are shown in the B column.

4. Switch check (1)


Page 7 Address 0E

Note: The data of page: 0, address: 10 must be “00”.

Bit Function When bit value=1 When bit value=0


0 POWER SW (XVTR MODE SW) (PS4400 block S008) ON (VCR or PLAYER) OFF
1 POWER SW (XCAM MODE SW) (PS4400 block S008) ON (CAMERA) OFF
2 DISPLAY/BATTERRY INFO SW (XBATT VIEW SW) ON OFF
(BJ-004 board S5801)
3 EJECT SW (XEJECT SW) (PS4400 flexible S006) ON OFF
4 CC DOWN SW (Mechanism chassis) ON (DOWN) OFF (UP)
5 PHOTO SW (PHOTO FREEZE) SW (FK4400 block S001) ON OFF
6 POWER SW (XPHOTO STBY SW) (PS4400 block S008) ON (MEMORY) OFF
7

Using method:
1) Select page: 7, address: 0E.
2) By discriminating the bit value of display data, the state of the switch can be discriminated.

5. Switch check (2)


Page 7 Address 0C

Note: The data of page: 0, address: 10 must be “00”.


Bit Function When bit value=1 When bit value=0
1 MIC jack (VF-156 board J5303) Used Not used
2 AUDIO/VIDEO jack (VF-156 board CN5405) Used Not used
3 AUDIO/VIDEO jack (VF-156 board CN5405) Used Not used
Using method:
1) Select page: 7, address: 0C.
2) By discriminating the bit value of display data, the state of the switch can be discriminated.

6-61
DCR-PC103E/PC104E/PC105/PC105E

6. Switch check (3)


Page 3 Address 61

Note: The data of page: 0, address: 10 must be “00”.


Bit Function When bit value=1 When bit value=0
6 HEADPHONS jack (FK4400 board J001) Used Not used

Using method:
1) Select page: 3, address: 61.
2) By discriminating the bit value of display data, the state of the switch can be discriminated.

7. Switch check (4)


Page 2 Address 60, 62 to 64, 66, 67

Note: The data of page: 0, address: 10 must be “00”.

Using method:
1) Select page: 2, address: 60, 62 to 66, 67.
2) By discriminating the display data, the pressed key can be discriminated.

Data
Address 00 19 EB
(00 to 0C) (0D to 24) (D8 to FF)
60 PHOTO FOCUS
(KEY AD0) (PHOTO REC) (FK4400 board) No key input
(IC4101 tl) (FK4400 block, S001, 002) (S003)
62
BACK LIGHT PNEL REVERSE PANEL NORMAL
(KEY AD2)
(BJ-004 board S5802) (FP-697 flexible S002) (FP-697 flexible S002)
(IC4101ya)
63
PANEL CLOSE PANEL OPEN
(KEY AD3)
(FP-697 flexible, S001) (FP-697 flexible S001)
(IC4101 yg)
64 FLASH LCD BACK LIGHIT LCD BACK LIGHIT
(KEY AD4) (PS4400 block S005) OFF ON
(IC4101 yh) (DCR-PC105/PC105E ONLY) (PS4400 block S007) (PS4400 block S007)
66 AUDIO/VIDEO jack AUDIO /VIDEO jack
(KEY AD6) Used Not used
(IC4101 yk) (VF-156 block CN5405) (VF-156 block CN5405)
67
(KEY AD7) START/STOP No key input
(IC4101 yl) (PS4400 block S004)

8. LED check
Page 7 Address 07 Bit5

Note: The data of page: 0, address: 10 must be “00”.

Using method:
1) Select page: 7, address: 07, and set data: 20. (Bit5=1)
2) Check that all LED (Recording lamp,Flash LED, Charge LED) are lit.
3) Select page: 7, address: 07, and set data: 00. (Bit5=0)

6-62
DCR-PC103E/PC104E/PC105/PC105E

9. Record of Use check (1)


Page 7 Address A7 to A9
Note1: When replacing the drum assembly or the mechanism deck, initialize the data of address: A7 to A9.
Note2: This data will be kept even if the lithium battery (LI-070 board BT6401 of the cabinet (R) assembly) is removed.
Note3: The data of page: 0, address: 10 must be “00”.

Address Function Remarks


A7 Drum rotation Hour (H) 100000th place digit and 10000th place digit of counted time
A8 counted time Hour (M) 1000th place digit and 100th place digit of counted time
A9 (BCD code) Hour (L) 10th place digit and 1st place digit of counted time
Using method:
1) The record of use data is displayed at addresses: A7 to A9.

Initializing method:
1) Select page: 7, address: 00, and set data: 71.
2) Select page: 7, address: 01, set data: 71 and press the PAUSE button.
3) Check that the data of page: 7, address: 02 is “00”.

10. Record of Use check (2)


Page 7 Address C8 to CD
Note1: This data will be kept even if the lithium battery (LI-070 board BT6401 of the cabinet (R) assembly) is removed.
Note2: The data of page: 0, address: 10 must be “00”.

Address Function Remarks


C8 User initial power Year
C9 on date Month After setting the clock, set the date of power on next
CA (BCD code) Day
CB Final condensation Year
CC occurrence data Month
CD (BCD code) Day

Using method:
1) The record of use data is displayed at addresses: C8 to CD.

6-63
DCR-PC103E/PC104E/PC105/PC105E

11. Record of Self-diagnosis check

Page 7 Address B0 to C6

Note1: This data will be kept even if the lithium battery (LI-070 board
BT6401 of the cabinet (R) assembly) is removed.
Note2: The data of page: 0, address: 10 must be “00”.

Address Self-diagnosis code


B0 “Repaired by” code (Occurred 1st time) *1
B1 “Block function” code (Occurred 1st time)
B2 “Detailed” code (Occurred 1st time)
B4 “Repaired by” code (Occurred 2nd time) *1
B5 “Block function” code (Occurred 2nd time)
B6 “Detailed” code (Occurred 2nd time)
B8 “Repaired by” code (Occurred 3rd time) *1
B9 “Block function” code (Occurred 3rd time)
BA “Detailed” code (Occurred 3rd time)
BC “Repaired by” code (Occurred 4th time) *1
BD “Block function” code (Occurred 4th time)
BE “Detailed” code (Occurred 4th time)
C0 “Repaired by” code (Occurred 5th time) *1
C1 “Block function” code (Occurred 5th time)
C2 “Detailed” code (Occurred 5th time)
C4 “Repaired by” code (Occurred the last time) *1
C5 “Block function” code (Occurred the last time)
C6 “Detailed” code (Occurred the last time)
*1: “01” t “C”, “03” t “E”

Using method:
1) The past self-diagnosis codes are displayed at addresses: BC
to C6.
Refer to “SELF-DIAGNOSIS FUNCTION” for detail of the
self-diagnosis code except for the code being written in the
following table.

Self-diagnosis Code
Block Detailed Symptom/State Correction
Repaired by:
Function Code
Data on A page or D page are Make data on A page and D
E 20 00
rewritten. page correct value.

Note3: When the flash error code (E : 91 : **) is displayed. After repair, clear the error flag in the following method.
1) Select page: 7, address: 00, set data: 80.
2) Select page: 7, address: 01, set data: 80 and press the PAUSE buttun.
3) Check that the data of page: 7, address: 02 is “01”.

6-64
DCR-PC103E/PC104E/PC105/PC105E
〈FOR CAMERA COLOR REPRODUCTION ADJUSTMENT〉

For NTSC model

DCR-PC105
Take a copy of CAMERA COLOR
REPRODUCTION FRAME with
a clear sheet for use.


For PAL model

DCR-PC103E/PC104E/PC105E

6-65E
Reverse 987625851.pdf

Revision History

S.M. Rev.
Ver. Date History Contents
issued
1.0 2003.04 Official Release — —