The What's New documents for ANSYS Electronics provide release information for the following:
1
What's New in ANSYS Electronics Desktop
R19.0
ANSYS is pleased to provide a great number of new and advanced features in ANSYS Electronics
Desktop (AEDT). The new features have been developed with guidance from our most innovative
customers. These advancements deliver solutions to amplify your engineering effectiveness,
simulate your most complex electronic design challenges, and accelerate your time to market.
ANSYS is particularly pleased to release the first exposure of RCS analysis in HFSS using the
SBR+ technology in AEDT.
In addition, two very significant changes have been made to our High Performance Computing
(HPC) solution.
l All core solver technologies utilize four (4) cores without HPC License Checkout providing
faster solutions. HPC products add on top of these four cores.
l We have unified the electronics high performance computing (eHPC) with the ANSYS HPC
licenses. AEDT solvers can now optionally use ANSYS HPC or ANSYS eHPC. For
multiphysics applications a single ANSYS HPC license will accelerate all ANSYS products.
The single desktop allows users to insert and co-simulate among the following design types:
Advanced integration allows users to insert HF/SI and EM analysis into projects that co-exist, with
drag and drop dynamic links between electromagnetic simulation, circuit simulation, and system
simulation for simple problem set-up and reliable performance.
2
ANSYS Electronics Desktop R19.0
3
ANSYS Electronics Desktop R19.0
HPC Enhancements
l Products use four cores with base solver. HPC products adds on to these four.
l Unification of the electronics high performance computing (eHPC) with the ANSYS HPC.
o For multiphysics applications a single ANSYS HPC license will accelerate all ANSYS
products.
o User option to choose legacy Electronics HPC, or ANSYS HPC.
l Remove shared drive requirement for LS-DSO
l Scheduler upgrades
l Job monitoring without direct network connection to compute nodes (R19.x)
4
What’s New in Circuit R19.0
Enhancements
l Nexxim simulation of PSPICE netlists
l Improved Transient Circuit Messaging
l Added 128b/130b & 128b/132b encoding schemes
l Added PSPICE Support for Coilcraft power inductors
l PAM4 support for IBIS-AMI, QuickEye, and VerifEye
l Nexxim High-Speed Serial Link Solutions
o Support for BIRD 158 in IBIS-AMI simulations
o Added additional RX jitter types for Eye Analyses
n Sinusoidal jitter & DCD jitter
l Improved message display to provide better user experience
l DOE accuracy fitting improvements for Transient Circuit Eye Analyses
l Added Triangular and Sinusoidal Spread Spectrum Clocking components
HFSS 3D Layout
l Added Three-Level Auto HPC
l Improved Phi Meshing Robustness
l Mesh speed improvements through enhancements to mesh pre-processing
l Added the Capacitor Library Browser to 3D Layout
l Added TDR analyses for LNA and Imported solution
l Improved visualization, rendering and performance
l Accuracy of Capacitor Touchstone interpolation improved
l Improved CPM Import into 3D Layout for HFSS & SIwave analysis
l Added Gerber RS274X translation Import
l Top & Bottom surface roughness supported for metal layers in 3D Layout
Selected Defect Corrections for Circuit R19.0
l DE150990 Exported image from plot now correctly excludes hidden legend
l DE153185 Push excitations to HFSS 3D Layout are now correct
l DE154360 QuickEye no longer shows an unexpected DC shift for single-ended lines (see in
DDR channels)
l DE155400 HFSS 3D Layout design that has HFSS design placed as a component now
successfully solves on Windows HPC and Linux schedulers
l DE157183 Updating VPowerSinusoidal/P_SIN component now netlists correctly
5
Circuit R19.0
The following items describe specific issues known at the time of release. Workarounds for these
items, if available, are included in the respective descriptions. Inclusion in this document does not
imply the issues and limitations are applicable to future releases. Go to the ANSYS Customer
Portal for information about service packs and any additional items not included in this document.
6
What’s New in ANSYS HFSS R19.0
ANSYS is pleased to provide a great number of new and advanced features in HFSS. The new
features have been developed with guidance from our most innovative customers. These
advancements deliver solutions to amplify your engineering effectiveness, simulate your most
complex electronic design challenges, and accelerate your product’s time to market.
7
HFSS R19.0
HFSS R19.0 has updated the slider bar settings for Curved Surface Meshing for surface-mesh
solvers. Because most surface-mesh applications require a highly precise representation of the
surface for accurate results, the default slider bar setting will provide a stricter representation of the
surface for triangle meshes compared with volumetric tetrahedra meshes. The following simulation
methods rely on surface meshes:
l HFSS-IE Designs
l IE Regions in HFSS
l PO Regions in HFSS
l SBR+ Regions in HFSS
l Characteristic Mode Solution Type in HFSS
Selected Defect Corrections for HFSS R19.0
l DE150990 Exported image from plot now correctly excludes hidden legend
l DE153185 Push excitations to HFSS 3D Layout are now correct
l DE154464 Correct finite array with PML with plane wave excitations
l DE155270 Near-field link excitation assigned to object in background or inside Dielectric IE
region now works correctly
l DE155400 HFSS 3D Layout design that has HFSS design placed as a component now
successfully solves on Windows HPC and Linux schedulers
l DE156484 Savant solver now accepts lossy dielectric/magnetic material defined in terms of
dielectric/magnetic loss tangent
l DE157709 Reassigning field plot on new geometry now works correctly
l DE157031 When the infinite sphere setting is defined in a local coordinate system, Savant
solver now gets the correct far field phase reference location
l DE157860 Electromagnetics systems on WorkBench correctly accept geometry coming
from Teamcenter (NX)
Known Issues and Limitations for HFSS R19.0
The following items describe specific issues known at the time of release. Workarounds for these
items, if available, are included in the respective descriptions. Inclusion in this document does not
imply the issues and limitations are applicable to future releases. Go to the ANSYS Customer
Portal for information about service packs and any additional items not included in this document.
l HFSS Transient GPU Solver R9.0 code does not work for NVIDIA Volta GPU Tesla V100
because V100 is not backward compatible with the code built by CUDA 6.5. This issue has
been reported to NVIDIA.
l DE160616 For the applications of FEBI + IE region or standalone IE region with sheet
objects, IE solver using ACA is, in most cases, significantly slower with Platform MPI on
Linux.
8
HFSS R19.0
l DE162274 Radiation and Gain Patterns are Wrong for HFSS Transient with Spherical
Radiation Boundaries
l DE163195 Implicit Transient Crashed for a Laser Simulation
l DE163480 PTD/UTD doesn't work correctly for SBR+ in some situations when both PEC
and non-PEC boundary conditions are present
l DE163498 The links in ACT Developer help in ACT extensions window don't work unless
Workbench is installed on the machine
9
What’s New in ANSYS Icepak R19.0 - Beta
ANSYS is pleased to provide a great number of new and advanced features in Icepak. The new
features have been developed with guidance from our most innovative customers. These
advancements deliver solutions to amplify your engineering effectiveness, simulate your most
complex electronic design challenges, and accelerate the time to market.
10
Icepak - Beta R19.0
o Field plotting
o Fields Summary Report
o Dynamic mesh visualization
o Inclusion of point and surface monitors
o Numerous enhancements to 3D field visualizations
Selected Defect Corrections for Icepak R19.0
l DE147570 Mesh qualities are now correct with a cabinet-only model in Icepak AEDT
Known Issues and Limitations for Icepak R19.0
The following items describe specific issues known at the time of release. Workarounds for these
items, if available, are included in the respective descriptions. Inclusion in this document does not
imply the issues and limitations are applicable to future releases. Go to the ANSYS Customer
Portal for information about service packs and any additional items not included in this document.
l DE163498 The links in ACT Developer help in ACT extensions window don't work unless
Workbench is installed on the machine
11
What’s New in ANSYS Maxwell R19.0
ANSYS is pleased to provide a great number of new and advanced features in Maxwell. The new
features have been developed with guidance from our most innovative customers. These
advancements deliver solutions to amplify your engineering effectiveness, simulate your most
complex electronic design challenges, and accelerate the time to market.
HPC/Performance
l Non-constant time step for general transient TDM (periodic allowed for 2D)
l External circuit PWM source for general transient TDM (periodic allowed for 2D)
l New GPU algorithm support for matrix solver in 3D eddy current solver.
l General transient TDM model for translation motion
Integrated motor solutions
l Machine Design Toolkit integrated into AEDT through ACT
l Machine Design Toolkit performance and robustness improvements
l Machine Design Toolkit - Induction Machine support
l Machine Design Toolkit UX improvements
l Manufacturing effects on core loss
l Irreversible temperature effect on permanent magnet demagnetization
l Nonlinear D-E curve in electrostatic solver
l Nonlinear J-E curve in DC conduction solver
l Multiple end-connection creation in RMxprt-created 2D FE model
l UDP for end fingers and press plate
l Lorentz force method used for conductors in magnetic solvers
Multiphysics
l Element-based harmonic stress coupling from 2D/3D transient solver
l Magnetostrictive vibration to magnetic core
Selected Defect Corrections for Maxwell R19.0
l DE150990 Exported image from plot now correctly excludes hidden legend
l DE154483 If memory is not enough for periodic TDM, an error message will be provided
l DE156843 Maxwell prefers the classic mesh, so the Phi mesher has been removed from
Maxwell
l DE157709 Reassigning field plot on new geometry now works correctly
l DE157912 Endless nonlinear iteration no longer occurs in 3D Magnetostatic solver
12
Maxwell R19.0
l DE160790 Skew is now correctly modeled when Maxwell circuit or Simplorer is involved in
2D transient
Known Issues and Limitations for Maxwell R19.0
The following items describe specific issues known at the time of release. Workarounds for these
items, if available, are included in the respective descriptions. Inclusion in this document does not
imply the issues and limitations are applicable to future releases. Go to the ANSYS Customer
Portal for information about service packs and any additional items not included in this document.
l DE163498 The links in ACT Developer help in ACT extensions window don't work unless
Workbench is installed on the machine
13
What’s New in ANSYS Q3D Extractor R19.0
ANSYS is pleased to provide a great number of new and advanced features in Q3D Extractor. The
new features have been developed with guidance from our most innovative customers. These
advancements deliver solutions to amplify your engineering effectiveness, simulate your most
complex electronic design challenges, and accelerate the time to market.
The following items describe specific issues known at the time of release. Workarounds for these
items, if available, are included in the respective descriptions. Inclusion in this document does not
imply the issues and limitations are applicable to future releases. Go to the ANSYS Customer
Portal for information about service packs and any additional items not included in this document.
l DE163498 The links in ACT Developer help in ACT extensions window don't work unless
Workbench is installed on the machine
14
What’s New in ANSYS Simplorer R19.0
ANSYS is pleased to provide the latest version of Simplorer with a number of improvements
developed with guidance from our most innovative customers. These advancements help to
amplify your engineering effectiveness in simulating complex power electronic and multi-domain
system designs.
15
Simplorer R19.0
The following items describe specific issues known at the time of release. Workarounds for these
items, if available, are included in the respective descriptions. Inclusion in this document does not
imply the issues and limitations are applicable to future releases. Go to the ANSYS Customer
Portal for information about service packs and any additional items not included in this document.
16
What’s New in ANSYS SIwave R19.0
ANSYS is pleased to provide a great number of new and advanced features in SIwave. The new
features have been developed with guidance from our most innovative customers. These
advancements deliver solutions to amplify your engineering effectiveness, simulate your most
complex electronic design challenges, and accelerate the time to market.
17
SIwave R19.0
l SIwave-PI
o Added ability to show RLCs between selected nets
o Compare Optimized, Unoptimized, and Bare Board Impedance Plots within PI Advisor
SIwave Ease-of-Use
l Added ACIS R28 support
l Oblong Solderball support
l Added dimension markers
l Numerous Pin Grouping improvements
l Added Iron Python IDE command window
l Added new “Special Selection” Modes
o Nets Between Nets
o Signal Nets between Components
o DC Connected Nets
l Added “heads-up, floating, and ghosting windows” to GUI
l Added a “Simulation Setup” export/import for all simulation types
o Ensures consistent setups between projects
l Improved the DC Power Tree setup using text import/export that reduce redundant manual
steps
3D Layout Improvements
l Added Three-Level Auto HPC
l Improved Phi Meshing Robustness
l Switched to intuitive Ribbons based interface
l Greater than 2x speed up in mesh pre-processing
l Added the Capacitor Library Browser to 3D Layout
l Added TDR analyses for LNA and Imported solution
l Improved visualization, rendering and performance
l Accuracy of Capacitor Touchstone interpolation improved
l Improved CPM Import into 3D Layout for HFSS & SIwave analysis
l Added Gerber RS274X translation Import (i.e. supports EagleCAD now)
l Top & Bottom surface roughness supported for metal layers in 3D Layout
Time Domain Circuit Solving
l Nexxim simulation of PSPICE netlists
l Improved Transient Circuit Messaging
l Added 128b/130b & 128b/132b encoding schemes
l Added PSPICE Support for Coilcraft power inductors
l PAM4 support for IBIS-AMI, QuickEye, and VerifEye
l Nexxim High-Speed Serial Link Solutions
18
SIwave R19.0
The following items describe specific issues known at the time of release. Workarounds for these
items, if available, are included in the respective descriptions. Inclusion in this document does not
imply the issues and limitations are applicable to future releases. Go to the ANSYS Customer
Portal for information about service packs and any additional items not included in this document.
l DE163657 Conducting materials are being incorrectly classified as dielectrics when ODB++
v8 files are imported into SIwave
19
Selected Defect Corrections R19.0
20
Selected Defect Corrections R19.0
Q3D Extractor
l DE150990 Exported image from plot now correctly excludes hidden legend
l DE152809 Differential S-parameters can be exported via Network Data Explorer in 2D
Extractor
l DE153943 Q3D-Icepak 2-way volume link functions correctly
l DE155702 Spectre transmission line model can be exported for frequency sweep in 2D
Extractor
l DE157709 Reassigning field plot on new geometry now works correctly
Simplorer
l DE154619 Fluent link can now be created with additional '-op' string in Fluent output
parameters
SIwave
l DE154766 Geometry processing options added to SIwave UI to benefit IC/interposer scale
layouts
21
Known Issues and Limitations R19.0
HFSS
l HFSS Transient GPU Solver R9.0 code does not work for NVIDIA Volta GPU Tesla V100
because V100 is not backward compatible with the code built by CUDA 6.5. This issue has
been reported to NVIDIA.
l DE160616 For the applications of FEBI + IE region or standalone IE region with sheet
objects, IE solver using ACA is, in most cases, significantly slower with Platform MPI on
Linux.
l DE162274 Radiation and Gain Patterns are Wrong for HFSS Transient with Spherical
Radiation Boundaries
l DE163195 Implicit Transient Crashed for a Laser Simulation
l DE163480 PTD/UTD doesn't work correctly for SBR+ in some situations when both PEC
and non-PEC boundary conditions are present
l DE163498 The links in ACT Developer help in ACT extensions window don't work unless
Workbench is installed on the machine
Circuit
l DE155896 Nexxim time-domain simulations (for example, Transient and QuickEye
analyses) containing non-causal microwave models (for example, microstrip gap model)
may not work.
l DE159799 Nexxim simulations (usually, the LNA) containing microwave components (e.g.,
elliptic bandpass filter) may not work with glibc versions greater than 2.17.157.
Workarounds: a) set LD_BIND_NOW=1 before launching AEDT command line, or b) use
glibc versions less than or equal to glibc 2.17.157
l DE161330 Recording script for changing Type, Num_Lines or Substrate property in
Component tab can set wrong Component on playback (Workaround: Record changing
Component property to correct value)
l DE161966 Nexxim simulations (usually, the transient analysis) containing Verilog-A
components do not work in Windows 10 (Workaround: Use Windows 7 or Linux)
l DE163498 The links in ACT Developer help in ACT extensions window don't work unless
Workbench is installed on the machine
EMIT
l DE163412 "Constant Loss" cable model does not include passive noise
Icepak
l DE163498 The links in ACT Developer help in ACT extensions window don't work unless
Workbench is installed on the machine
22
Known Issues and Limitations R19.0
Maxwell
l DE163498 The links in ACT Developer help in ACT extensions window don't work unless
Workbench is installed on the machine
Q3D Extractor
l DE163498 The links in ACT Developer help in ACT extensions window don't work unless
Workbench is installed on the machine
Simplorer
l DE158132 Distributed Solve is currently not supported for the Simplorer Maxwell
cosimulation
l DE162553 For the new RLGC link, the Simplorer-Q3D link gives wrong results if nets in
Q3D do not have a source and sink defined. (Workaround is to either manually remove all
nets that do not have source and sink defined or to always define a source and sink for all
nets.)
l DE162685 Necessary annotations for creating Modelica conservative pins for mechanical or
fluid domains in Simplorer are missing
l DE163498 The links in ACT Developer help in ACT extensions window don't work unless
WB is installed on the machine
SIwave
l DE163657 Conducting materials are being incorrectly classified as dielectrics when ODB++
v8 files are imported into SIwave
23