What are the LS-5 V2 controls? Form, fit and enhanced function successor of LS-5 V1 series controls. It includes, • Two breaker control variants — Increases our competitiveness in multi-breaker applications where load is served by MCB & GGB
• Compliance according to grid codes (BDEW and LS-521 LS-522
VDE AR-N 4105) — Solves grid code challenge of single genset connected to the national grid (in Germany)
• Separate incoming and outgoing current inputs
per phase — For ease of application in retrofits LS-511 LS-512
The Total Control Package easYgen-3400XT/3500XT genset control • Complete engine-generator control and protection • Isolated, islanded or utility parallel operation • CAN/ETH communication and load sharing • Synchronization, dead bus closure prioritization • Automatic Load Dependent Start/Stop (LDSS) • Base load, import/export control, soft load/unload
LS-511/521 circuit breaker control
• Mains measurement and protection/decoupling • Synchronization of easYgen-equipped gensets • Modbus communication, can be used as a stand-alone voltage/frequency and synch-check relay
Allows you to standardize on one solution to fit a multitude of
applications Proven system for managing complex distribution systems • multiple generators • multiple utility feeds and tie breakers • multiple bus segments
Reduced point-to-point wiring- single CAN communication line between
easYgen-3400XT/3500XT Features Control up to 32 easYgen equipped Automatic Load Dependent gensets Start/Stop Automatic mains failure, Var or Power Factor control emergency run Isochronous Load and Var sharing Slip or phase match synch, dead over CAN bus closing Redundant Ethernet Three phase, true RMS power communication sensing Door and panel mount versions Baseload, import/export control Remote Panel RP-3000XT Soft load/unload connectivity
LS-5x1/LS-5x2 Features Control up to 16 LS-5 equipped Communication to easYgen controls utility or tie breakers over CAN Three phase, true RMS power 1 breaker control and 2 breaker sensing control versions Protection/decoupling functions Door and panel mount versions (ANSI 25, 27/59, 81O/U, 47, 78, 81) Soft load/unload Vector adjustment for RS-485 Modbus port synchronization across transformers Segment handling and import/export control
What problems do LS-5 V2 controls solve? (1) Two Breaker Control Variants • Expands the total number of managed breakers up to 32 • Accepts power measurement from utility approved 3rd party measurement transducer for loading/unloading • Remotely selectable breaker transition modes for transfer switch applications: Open, Closed (short parallel <100ms), Inter-change, Indefinite parallel • Software configurable to function as LS-5x1 facilitating hardware standardization
easYgen/LS-5 ToolKit Programming PC programming with Woodward ToolKit software Allows visualization of all settings parameters Same navigation structure between HMI and ToolKit Trending tools to aid commissioning