Вы находитесь на странице: 1из 3

Electrical Design Analysis

Voltage Drop Calculation

PROJECT: TWO STOREY RESIDENCES


LOCATION: KM32 NATIONAL HIGHWAY TINANDEL STREET BIÑAN CITY, LAGUNA

VOLTAGE DROP DIAGRAM

49.2ft 3.94ft 73.36ft

2 - 200 mm² THWN 2 - 150 mm² THWN 2 - 35mm² THWN

SERVICE ENTRANCE MDP PP1 CO


230V 2P, 2WIRE+G, 60Hz
16.54ft 63.71ft

2 - 125 mm² THWN 2 - 35 mm² THWN

PP2 CO

Item WIRE
Description Phase. K L I VD VD%
No. CM SET
1 Service Entrance 1Ø 12 49.2 197.83 A 400000 1 0.58 0.25%
2 Panel Board 1 1Ø 12 3.936 124.27 A 300000 1 0.04 0.02%
Convenience Outlet
3 1Ø 12 73.36 8.00 6530 1 2.16
1 0.94%
4 Panel Board 2 1Ø 12 16.54 98.61 A 250000 1 0.16 0.07%
convenience Outlet
5 1Ø 12 63.71 8.00 6530 1 1.87
2 0.81%
TOTAL 4.81V 1.83%

ELECTRICAL PLAN AND DESIGN OF A CHECKED BY:


RAPHAEL MARTIN V. RESIDENTIAL HOUSE
ENGR. ROVENSON SEVILLA
PALOGAN 1753 TINANDEL STREET KM 32 NATIONAL
TECHNOLOGICAL UNIVERSITY OF HIGHWAY BINAN CITY, LAGUNA PTR NO. NO.
THE PHILIPPINES- MANILA RAPHAEL MARTIN V. PALOGAN FAX NO. DATE ISSUED:
OWNER PRC NO. TIN:
Electrical Design Analysis

Short Circuit Calculation

SYSTEM DIAGRAM
SERVICE ENTRANCE
230V, 1P, 60Hz
2W + GND
M

2 - 200 mm² THWN


1 - 150 mm² THWN
IN 65 mm RMC

300AT/
400AF,2P

150AT/2P 125AT/2P
1 2

GB

IMPEDANCE DIAGRAM
Zu Zs
230V
Source

R X WIRE
Item
Description Phase. mΩ mΩ L R X Z
No. SIZE SET
/100ft /100ft
Utility
1 1Ø 2.97 2.69 70.69 400MCM 1 2.1mΩ 1.9mΩ 2.83mΩ
Distribution Line
2 Service Entrance 1Ø 3.33 2.71 49.2 350MCM 1 1.64mΩ 1.33mΩ 2.11mΩ
TOTAL 3.74mΩ 3.23mΩ 4.94mΩ

SHORT CIRCUIT CURRENT IS 46558.70A

ELECTRICAL PLAN AND DESIGN OF A CHECKED BY:


RAPHAEL MARTIN V. RESIDENTIAL HOUSE
ENGR. ROVENSON SEVILLA
PALOGAN 1753 TINANDEL STREET KM 32 NATIONAL
TECHNOLOGICAL UNIVERSITY OF HIGHWAY BINAN CITY, LAGUNA PTR NO. NO.
THE PHILIPPINES- MANILA RAPHAEL MARTIN V. PALOGAN FAX NO. DATE ISSUED:
OWNER PRC NO. TIN:

Вам также может понравиться