of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com
Electrical Apparatus: Power-signal-control unit and terminal board family EJB - . . . . / . . series
Optional accessory:
Type of Protection: General requirements, Flameproof enclosures, Intrinsic safety, Protection by enclosures „tD”
Marking: Ex d IIB+H2
Ex d IIB+H2 T6
Ex d IIB+H2 T6....T3
Ex d [ia/ib] IIB+H2 T6.....T3
Ex tD A21 IP 66
Ex tD A21 IP 66 T85ºC
Ex tD A21 IP 66 T85ºC … T150°C
Ex tD [iaD] A21 IP66 T85ºC … T150°C
Ex tD [ibD] A21 IP66 T85ºC … T150°C
-20 °C ? Tamb ? +40 °C
-60 °C ? Tamb ? +40 °C
-20 °C ? Tamb ? +80 °C
-20 °C ? Tamb ? +130 °C
Position: Director
Signature:
(for printed version)
Date:
Additional Manufacturing
location(s):
This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the
IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and
found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx
Scheme Rules, IECEx 02 and Operational Documents as amended.
STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was
found to comply with the following standards:
IEC 60079-0 : 2004 Electrical apparatus for explosive gas atmospheres - Part 0: General requirements
Edition:4.0
IEC 60079-1 : 2003 Electrical apparatus for explosive gas atmospheres - Part 1: Flameproof enclosure 'd'
Edition: 5
IEC 60079-11 : 1999 Electrical apparatus for explosive gas atmospheres - Part 11: Intrinsic safety 'i'
Edition:4
IEC 61241-0 : 2004 Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements
Edition:1
IEC 61241-1 : 2004 Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by enclosures "tD"
Edition:1
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the
Test Report:
IT/CES/QAR06.0001/00 IT/CES/QAR06.0001/05
IECEx Certificate
of Conformity
Certificate No: IECEx BKI 06.0009 Issue No: 3
Schedule
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
CONDITIONS OF CERTIFICATION: NO
IECEx Certificate
of Conformity
Certificate No: IECEx BKI 06.0009 Issue No: 3
-EJB type series has been extended by the type EJB-08, EJB 71 and 91 sizes.
Annex:
1. Description
The Power-signal-control unit and terminal board family type of EJB series have multipurpose function. The flameproof
enclosures are made of light alloy or stainless steel in different sizes. The enclosures have very large applicabilities:
the enclosures with temperature class T6 or T5 may be completed with various accessories (push-buttons, signal/
indicator lamps, selector switches, potentiometers, leverages and switches control, systems of respiration/breathing
and drainage, glass windows) some of them may be mounted on the cover. The enclosures also may contain different
electronic equipment (switches, fuses, terminals, relays, contactors, transformers, elevator transformers, indicator
tools, reactors, igniters, condensers, inspection panels, PLC, rack with electronic cards, intrinsically safe barriers) or
may be used them as supply/feeding units. The degree of protection IP 55 in accordance with IEC 60529 is guaranteed
by the treatment of the flat joint lamination with application of silicone Loctite grease 8104 , the accessories must be
provided with O-ring type gasket. The enclosures can be provided with threaded holes in the walls or in the bottom, to
allow cable entry accessories to be screwed in. The Ex-cable entries must be separately certified by the appropriate
IEC standards. Only blue colored terminals and cable glands can be used for intrinsically safety circuits in the
enclosure.
Enclosures with temperature classes T3 (150°C) and T4 (135°C) may not provided with accessories which use
compound sealed parts with thermical stability lower than 120°C (windows, signal lamps).
2. General parameters
2.1.4 Depending on electric equipment mounted inside the enclosures, the following maximum ratings are provided
for:
- rated operating voltage :12 … 220 V DC
24 … 750 V AC for control and signalling units
24 … 660 V AC for power units
20000 V only for elevator transformers
- nominal frequency :50 / 60 Hz
- rated power of built-in indicator/pilot lamps :≤ 3 W ( for T5 – T100°C and T6 – T85°C )
- maximum voltage of associated apparatus :≤ 250 V
2.1.5 All enclosure are provided for the possibility of connecting an anti-condensation heating resistor positioned at
least 50 mm from every inside wall, with following electrical characteristics:
- nominal operating voltage :≤ 220 V
- nominal power :≤ 25 W
Thermal dissipation of devices contained inside the enclosure must respect limits shown in the following
table:
enclosure enclosure class T3 – T150°C class T4 – T135°C class T5 – T100°C class T6 – T85°C
3
type volume in cm W A W A W A W A
EJB-11 1250 80 180 20 110 15 16 13 16
EJB-12 970 50 180 16 110 13 16 10 16
EJB-13 1680 80 180 20 110 15 16 13 16
EJB-13A 2550 100 180 40 110 30 16 15 16
EJB-123 1880 100 180 40 110 30 16 15 16
EJB-21 5420 160 180 130 110 100 55 50 55
EJB-23 8200 180 180 150 110 100 55 75 55
EJB-30 11700 250 180 200 110 100 55 75 55
EJB-31 18460 300 180 200 110 200 55 88 55
EJB-41 7350 160 180 130 110 100 55 65 55
EJB-51 33000 420 350 300 260 300 55 100 55
EJB-61 74500 420 350 300 260 350 55 100 55
EJB-63 48100 420 350 300 260 350 55 100 55
EJB-64 38300 420 350 300 260 350 55 100 55
EJB-81 26800 420 350 260 260 300 55 100 55
EJB-1 4860 160 180 130 110 100 55 50 55
EJB-TR1 8035 180 180 150 110 100 55 75 55
EJB-2 11910 250 180 200 110 100 55 75 55
EJB-3 34100 420 350 300 260 300 55 100 55
EJB-4 36170 420 350 300 260 350 55 100 55
ADDENDUM TO IECEx CERTIFICATE OF CONFORMITY
IECEx BKI 06.0009
Page 3 of 3
2.6 If the enclosure consists anticondensate heater, then after de-energizing must wait 15 minutes before opening.
2.7 The enclosures can be provided with threaded holes on the walls or on the bottom, to allow cable entry
accessories to be screwed in. The Ex-cable entries must be separately certified by the appropriate IEC standards.
Their degree of protection must be at least IP 55. The cables must be adapted to the 85°C (T6) , 100°C (T5) , 135°C
(T4) , 150°C (T3) temperatures.
2.8 If silicon grease is used for the required ingress protection then must renew (must be restored) every time cover
is opened.
2.9 For use in environments where combustible dusts may be present, the user must see to regular cleaning of the
apparatus so as to prevent build-up of dust on the surface.
Drawings
Technical note NT-199-IEC- REV1 (10 pages) Rev. 1 28.08.2006
Instructions for use IU-EJB199-IEC-REV1 (2 pages) Rev. 1 28.08.2006
Construction features PNC-199-IEC-FG1 1/4 (Drwg) Rev. 0 30.03.2005
Construction features PNC-199-IEC-FG2 2/4 (Drwg) Rev. 0 30.03.2005
Construction features PNC-199-IEC-FG3 3/4 (Drwg) Rev. 0 30.03.2005
Construction features PNC-199-IEC-FG4 4/4 (Drwg) Rev. 0 30.03.2005
EJB empty enclosure name plate „EJB empty enclosure name plate” (Drwg) Rev. 0 23.03.2005
1. Description
The application temperature range of the EJB series empty and mounted enclosures without inspection window was extended
to the temperature values of -60 °C, +80 °C and +130 °C.
The technical parameters of the units mountable into the enclosures the different electrical devices (fuses, terminal blocks,
relays, solenoid switches, transformers, booster transformers, display units, choke coils, ignition units, condensers, control
panels, PLC, card receiving devices with electronic cards, intrinsically safe isolators or safety barriers, supply units) shall exceed
the application temperature limits.
The technical parameters of the certified cable entries mountable onto the side of the enclosures shall exceed the application
temperature limits.
The seal and the spring washer under the plugs of the enclosures ensure perfect closure and the IP 66 protection.
2. General parameters
2.1. Protection marking depending on the ambient temperature with exclusion of light-transmitting parts:
2.2.4 Depending on electric equipment mounted inside the enclosures, the following maximum ratings are provided for:
according to the before certificate, unchanged
2.2.5 All enclosure are provided for the possibility of connecting an anti-condensation heating resistor positioned at least 50
mm from every inside wall, with following electrical characteristics:
according to the before certificate, unchanged
ADDENDUM TO IECEx CERTIFICATE OF CONFORMITY
IECEx BKI 06.0009 1st. Amendment
Page 2 of 3
+40 °C
Enclosure
Class T3 – T150°C Class T4 – T135°C Class T5 – T100°C Class T6 – T85°C
Volume
Type 3
[ cm ]
W A W A W A W A
EJB-22 3450 180 180 150 110 100 55 50 55
+80 °C
Enclosure
Class T3 – T150°C Class T4 – T135°C Class T5 – T100°C Class T6 – T85°C
Volume
Type 3
[ cm ]
W A W A W A W A
EJB-11 1250 50 142 11 82 4 8 -- --
EJB-12 970 31 142 9 82 4 8 -- --
EJB-13 1680 50 142 11 82 4 8 -- --
EJB-13A 2550 62 142 22 82 8 8 -- --
EJB-123 1880 62 142 22 82 8 8 -- --
EJB-21 5420 99 142 72 82 27 29 -- --
EJB-22 3450 111 142 83 82 27 29 -- --
EJB-23 8200 111 142 83 82 27 29 -- --
EJB-30 11700 155 142 111 82 27 29 -- --
EJB-31 18460 186 142 111 82 55 29 -- --
EJB-41 7350 99 142 72 82 27 29 -- --
EJB-51 33000 260 275 167 194 82 29 -- --
EJB-61 74500 260 275 167 194 95 29 -- --
EJB-63 48100 260 275 167 194 95 29 -- --
EJB-64 38300 260 275 167 194 95 29 -- --
EJB-81 26800 260 275 142 194 82 29 -- --
EJB-1 4860 99 142 72 82 27 29 -- --
EJB-TR1 8035 111 142 83 82 27 29 -- --
EJB-2 11910 155 142 111 82 27 29 -- --
EJB-3 34100 260 275 167 194 82 29 -- --
EJB-4 36170 260 275 167 194 95 29 -- --
EJB-5 11020 155 142 111 82 27 29 -- --
EJB-51F 13470 186 142 111 82 27 29 -- --
EJB-6 59050 260 275 167 194 95 29 -- --
EJB-61F 32950 260 275 167 194 82 29 -- --
EJB-C237 3870 99 142 72 82 27 29 -- --
+130 °C
Enclosure
Class T3 – T150°C Class T4 – T135°C Class T5 – T100°C Class T6 – T85°C
Volume
Type 3
[ cm ]
W A W A W A W A
EJB-11 1250 11 68 -- -- -- -- -- --
EJB-12 970 7 68 -- -- -- -- -- --
EJB-13 1680 11 68 -- -- -- -- -- --
EJB-13A 2550 14 68 -- -- -- -- -- --
EJB-123 1880 14 68 -- -- -- -- -- --
ADDENDUM TO IECEx CERTIFICATE OF CONFORMITY
IECEx BKI 06.0009 1st. Amendment
Page 3 of 3
EJB-21 5420 23 68 -- -- -- -- -- --
EJB-22 3450 26 68 -- -- -- -- -- --
EJB-23 8200 26 68 -- -- -- -- -- --
EJB-30 11700 36 68 -- -- -- -- -- --
EJB-31 18460 43 68 -- -- -- -- -- --
EJB-41 7350 23 68 -- -- -- -- -- --
EJB-51 33000 60 132 -- -- -- -- -- --
EJB-61 74500 60 132 -- -- -- -- -- --
EJB-63 48100 60 132 -- -- -- -- -- --
EJB-64 38300 60 132 -- -- -- -- -- --
EJB-81 26800 60 132 -- -- -- -- -- --
EJB-1 4860 23 68 -- -- -- -- -- --
EJB-TR1 8035 26 68 -- -- -- -- -- --
EJB-2 11910 36 68 -- -- -- -- -- --
EJB-3 34100 60 132 -- -- -- -- -- --
EJB-4 36170 60 132 -- -- -- -- -- --
EJB-5 11020 36 68 -- -- -- -- -- --
EJB-51F 13470 43 68 -- -- -- -- -- --
EJB-6 59050 60 132 -- -- -- -- -- --
EJB-61F 32950 60 132 -- -- -- -- -- --
EJB-C237 3870 23 68 -- -- -- -- -- --
3. Ambient temperature(s)
4. Ingress protection
IP 66
5. Routine test
The manufacturer shall carry out the routine tests prescribed at paragraph 27 of the IEC 60079-0 standard and at paragraph
16 of the IEC 60079-1 standard.
The routine overpressure test shall be carried out at:
- 11,5 bar on the enclosures EJB – 2, 5, 51-F, 11, 12, 123, 13, 21, 23, 30, 31, 41, 51, 61, 63, 64, 81
- 12 bar on the enclosures EJB – 1, 3, 4, 6, 61-F, C237, TR1
with the static method (paragraph 15.1.3.1 of the IEC 60079-1 standard)
6. Drawings
Technical note NT-223-IEC- REV0 (18 pages) Rev. 0 2007.12.18.
Instructions for use IU-223-IEC-REV0 (13 pages) Rev. 0 2007.12.18.
Construction features PNC-223-IEC (Drwg) Rev. 0 2007.12.18.
EJB empty enclosure name plate PNC 223-IEC-tag (Drwg) Rev. 0 2007.12.18.
Test Report IP IMQ 43SH00033 (8 pages) 2007.11.20.
Data sheets
7. Test reports
nd
Overpressure test 2 (-50 °C´) 07010d1 (9 pages) 2007.11.22.
nd
Overpressure test 2 (-50 °C´) 07010d2 (9 pages) 2007.11.30.
nd
Overpressure test 2 (+80 °C´) 07010d3 (9 pages) 2008.02.05.
nd
Overpressure test 2 (+80 °C´) 07010d4 (9 pages) 2008.01.17.
nd
Overpressure test 2 (+130 °C´) 07010d5 (9 pages) 2008.02.15.
nd
Overpressure test 2 (+130 °C´) 07010d5 (9 pages) 2008.01.21.
nd
Overpressure test 2 (-60 °C´) 07010d8 (9 pages) 2008.04.22.
nd
Overpressure test 2 (-60 °C´) 07010d7 (9 pages) 2008.04.24.
Test of ignition transmission explosion test (-50 °C´) 07010g1 (9 pages) 2007.11.27.
Test of ignition transmission explosion test (-50 °C´) 07010g2 (9 pages) 2007.12.04.
Test of ignition transmission explosion test (+80 °C´) 07010g3 (13 pages) 2008.02.07.
Test of ignition transmission explosion test (+80 °C´) 07010g4 (13 pages) 2008.01.18.
Test of ignition transmission explosion test (+130 °C´) 07010g5 (13 pages) 2008.02.19.
ADDENDUM TO IECEx CERTIFICATE OF CONFORMITY
IECEx BKI 06.0009 1st. Amendment
Page 4 of 3
Test of ignition transmission explosion test (+130 °C´) 07010g6 (13 pages) 2008.01.21.
Test of ignition transmission explosion test (-60 °C´) 07010g7 (13 pages) 2008.05.20.
Test of ignition transmission explosion test (-60 °C´) 07010g8 (13 pages) 2008.05.28.
ADDENDUM TO IECEx CERTIFICATE OF CONFORMITY
IECEx BKI 06.0009 2nd. Amendment
Page 1 of 3
1. Description
The application temperature range of the EJB series empty and mounted enclosures without inspection window was extended
to the temperature values of -60 °C, +80 °C and +130 °C.
The technical parameters of the units mountable into the enclosures the different electrical devices (fuses, terminal blocks,
relays, solenoid switches, transformers, booster transformers, display units, choke coils, ignition units, condensers, control
panels, PLC, card receiving devices with electronic cards, intrinsically safe isolators or safety barriers, supply units) shall not
exceed the application temperature limits.
The technical parameters of the certified cable entries mountable onto the side of the enclosures shall not exceed the
application temperature limits.
The seal and the spring washer under the plugs of the enclosures ensure perfect closure and the IP 66 protection.
2. General parameters
2.1. Protection marking depending on the ambient temperature with exclusion of light-transmitting parts:
2.2.4 Depending on electric equipment mounted inside the enclosures, the following maximum ratings are provided for:
according to the before certificate, unchanged
2.2.5 All enclosure are provided for the possibility of connecting an anti-condensation heating resistor positioned at least 50
mm from every inside wall, with following electrical characteristics:
according to the before certificate, unchanged
ADDENDUM TO IECEx CERTIFICATE OF CONFORMITY
IECEx BKI 06.0009 2nd. Amendment
Page 2 of 3
+40 °C
Enclosure
Class T3 – T150°C Class T4 – T135°C Class T5 – T100°C Class T6 – T85°C
Volume
Type
[ cm3 ]
W A W A W A W A
EJB-22 3450 180 180 150 110 100 55 50 55
+80 °C
Enclosure
Class T3 – T150°C Class T4 – T135°C Class T5 – T100°C Class T6 – T85°C
Volume
Type
[ cm3 ]
W A W A W A W A
EJB-11 1250 50 142 11 82 4 8 -- --
EJB-12 970 31 142 9 82 4 8 -- --
EJB-13 1680 50 142 11 82 4 8 -- --
EJB-13A 2550 62 142 22 82 8 8 -- --
EJB-123 1880 62 142 22 82 8 8 -- --
EJB-21 5420 99 142 72 82 27 29 -- --
EJB-22 3450 111 142 83 82 27 29 -- --
EJB-23 8200 111 142 83 82 27 29 -- --
EJB-30 11700 155 142 111 82 27 29 -- --
EJB-31 18460 186 142 111 82 55 29 -- --
EJB-41 7350 99 142 72 82 27 29 -- --
EJB-51 33000 260 275 167 194 82 29 -- --
EJB-61 74500 260 275 167 194 95 29 -- --
EJB-63 48100 260 275 167 194 95 29 -- --
EJB-64 38300 260 275 167 194 95 29 -- --
EJB-81 26800 260 275 142 194 82 29 -- --
EJB-1 4860 99 142 72 82 27 29 -- --
EJB-TR1 8035 111 142 83 82 27 29 -- --
EJB-2 11910 155 142 111 82 27 29 -- --
EJB-3 34100 260 275 167 194 82 29 -- --
EJB-4 36170 260 275 167 194 95 29 -- --
EJB-5 11020 155 142 111 82 27 29 -- --
EJB-51F 13470 186 142 111 82 27 29 -- --
EJB-6 59050 260 275 167 194 95 29 -- --
EJB-61F 32950 260 275 167 194 82 29 -- --
EJB-C237 3870 99 142 72 82 27 29 -- --
+130 °C
Enclosure
Class T3 – T150°C Class T4 – T135°C Class T5 – T100°C Class T6 – T85°C
Volume
Type
[ cm3 ]
W A W A W A W A
EJB-11 1250 11 68 -- -- -- -- -- --
EJB-12 970 7 68 -- -- -- -- -- --
EJB-13 1680 11 68 -- -- -- -- -- --
EJB-13A 2550 14 68 -- -- -- -- -- --
EJB-123 1880 14 68 -- -- -- -- -- --
ADDENDUM TO IECEx CERTIFICATE OF CONFORMITY
IECEx BKI 06.0009 2nd. Amendment
Page 3 of 3
EJB-21 5420 23 68 -- -- -- -- -- --
EJB-22 3450 26 68 -- -- -- -- -- --
EJB-23 8200 26 68 -- -- -- -- -- --
EJB-30 11700 36 68 -- -- -- -- -- --
EJB-31 18460 43 68 -- -- -- -- -- --
EJB-41 7350 23 68 -- -- -- -- -- --
EJB-51 33000 60 132 -- -- -- -- -- --
EJB-61 74500 60 132 -- -- -- -- -- --
EJB-63 48100 60 132 -- -- -- -- -- --
EJB-64 38300 60 132 -- -- -- -- -- --
EJB-81 26800 60 132 -- -- -- -- -- --
EJB-1 4860 23 68 -- -- -- -- -- --
EJB-TR1 8035 26 68 -- -- -- -- -- --
EJB-2 11910 36 68 -- -- -- -- -- --
EJB-3 34100 60 132 -- -- -- -- -- --
EJB-4 36170 60 132 -- -- -- -- -- --
EJB-5 11020 36 68 -- -- -- -- -- --
EJB-51F 13470 43 68 -- -- -- -- -- --
EJB-6 59050 60 132 -- -- -- -- -- --
EJB-61F 32950 60 132 -- -- -- -- -- --
EJB-C237 3870 23 68 -- -- -- -- -- --
3. Ambient temperature(s)
4. Ingress protection
IP 66
5. Routine test
The manufacturer shall carry out the routine tests prescribed at paragraph 27 of the IEC 60079-0 standard and at paragraph
16 of the IEC 60079-1 standard.
The routine overpressure test shall be carried out at:
- 11,5 bar on the enclosures EJB – 2, 5, 51-F, 11, 12, 123, 13, 21, 23, 30, 31, 41, 51, 61, 63, 64, 81
- 12 bar on the enclosures EJB – 1, 3, 4, 6, 61-F, C237, TR1
with the static method (paragraph 15.1.3.1 of the IEC 60079-1 standard)
6. Drawings
Technical note NT-223-IEC- REV0 (18 pages) Rev. 0 2007.12.18.
Instructions for use IU-223-IEC-REV0 (13 pages) Rev. 0 2007.12.18.
Construction features PNC-223-IEC (Drwg) Rev. 0 2007.12.18.
EJB empty enclosure name plate PNC 223-IEC-tag (Drwg) Rev. 0 2007.12.18.
Test Report IP IMQ 43SH00033 (8 pages) 2007.11.20.
Data sheets
7. Test reports
Overpressure test 2nd (-50 °C´) 07010d1 (9 pages) 2007.11.22.
Overpressure test 2nd (-50 °C´) 07010d2 (9 pages) 2007.11.30.
Overpressure test 2nd (+80 °C´) 07010d3 (9 pages) 2008.02.05.
Overpressure test 2nd (+80 °C´) 07010d4 (9 pages) 2008.01.17.
Overpressure test 2nd (+130 °C´) 07010d5 (9 pages) 2008.02.15.
Overpressure test 2nd (+130 °C´) 07010d5 (9 pages) 2008.01.21.
Overpressure test 2nd (-60 °C´) 07010d8 (9 pages) 2008.04.22.
Overpressure test 2nd (-60 °C´) 07010d7 (9 pages) 2008.04.24.
Test of ignition transmission explosion test (-50 °C´) 07010g1 (9 pages) 2007.11.27.
Test of ignition transmission explosion test (-50 °C´) 07010g2 (9 pages) 2007.12.04.
Test of ignition transmission explosion test (+80 °C´) 07010g3 (13 pages) 2008.02.07.
Test of ignition transmission explosion test (+80 °C´) 07010g4 (13 pages) 2008.01.18.
Test of ignition transmission explosion test (+130 °C´) 07010g5 (13 pages) 2008.02.19.
ADDENDUM TO IECEx CERTIFICATE OF CONFORMITY
IECEx BKI 06.0009 2nd. Amendment
Page 4 of 3
Test of ignition transmission explosion test (+130 °C´) 07010g6 (13 pages) 2008.01.21.
Test of ignition transmission explosion test (-60 °C´) 07010g7 (13 pages) 2008.05.20.
Test of ignition transmission explosion test (-60 °C´) 07010g8 (13 pages) 2008.05.28.
ADDENDUM TO IECEx CERTIFICATE OF CONFORMITY
Amendment 3 to
IECEx BKI 06.0009
Page 1 of 4
1. Description
This amendment comprises the following items :
- Update of normative references as follows :
IEC 60079-0 : 2007 (Ed. 5)
IEC 60079-1 : 2007 (Ed. 6)
IEC 60079-11 : 2006 (Ed. 5)
IEC 60079-31: 2008 ( Ed. 1 )
- In comparison with the basic certificate as well as amendments 1 and 2 the EJB type series has been extended by the
type EJB-08, EJB 71 and 91 sizes.
2. General parameters
2.1 Type of protection and protection marking
2.1.1 Protection marking depending on the ambient temperature without inspection window, except for the EJB 71 and
EJB 91 type variations
Protection marking depending on the ambient temperature with square or rectangular inspection window
-20°C ≤ Tamb ≤ +60°C
Terminal boards enclosure series Ex db IIB+H2 T6...T5 Ex tb IIIC T85°C...T100°C IP66
Ex db [ia/ib] IIB+H2 T6...T5
Power units series Ex db IIB+H2 T6...T5 Ex tb IIIC T85°C...T100°C IP66
Control and signalling units series Ex db IIB+H2 T6...T5 Ex tb IIIC T85°C...T100°C IP66
Ex db [ia IIA Ga] IIB+H2 T6...T5
Ex db [ia IIB Ga] IIB+H2 T6...T5
Ex db [ia IIC Ga] IIB+H2 T6...T5
Ex db [ib IIA Gb] IIB+H2 T6...T5
Ex db [ib IIB Gb] IIB+H2 T6...T5
Ex db [ib IIC Gb] IIB+H2 T6...T5
Protection marking depending on the ambient temperature with inspection window type GUBW 1, 11, 2, 3
-50°C ≤ Tamb ≤ +80°C
2.2.1 Electrical data of basic type EJB... series except for the EJB 71 and 91 type variations according to the basic
certificate and Issue 1, 2 unchanged
ExTR :
Status*: Issued
ExTR Free Reference HU/BKI/06/P00205/115
Number*:
List of Standards Covered*: IEC 600790 (Ed.4.0); IEC 600791 (Ed. 5); IEC 6007911 (Ed.4); IEC 612410 (Ed.1); IEC 61241
1 (Ed.1)
Model Reference*: .
Related IECEx Certificates: IECEx BKI 06.0009 issue: 1 [Current]
IECEx BKI 06.0009 issue: 2 [Current]
IECEx BKI 06.0009 issue: 3 [Current]
IECEx BKI 06.0009 issue: 0 [Current]
Comment:
Attachment:
Last modified: 21/02/2013 05.08.43 Copyright © IECIECEx 2015 , Geneva, Switzerland. All rights reserved.
IECEx Technical Report: HU/BKI/ExTR06.0013/01 details
ExTR :
Status*: Issued
ExTR Free Reference HU/BKI/07/P01007/12
Number*:
Details of change*: The application temperature range of the EJB series empty and mounted enclosures without
inspection window was extended to the temperature values of 60 °C, +80 °C and +130 °C.
The technical parameters of the units mountable into the enclosures the different electrical
devices (fuses, terminal blocks, relays, solenoid switches, transformers, booster transformers,
display units, choke coils, ignition units, condensers, control panels, PLC, card receiving devices
with electronic cards, intrinsically safe isolators or safety barriers, supply units) shall exceed the
application temperature limits.
The technical parameters of the certified cable entries mountable onto the side of the enclosures
shall exceed the application temperature limits.
The seal and the spring washer under the plugs of the enclosures ensure perfect closure and the
IP 66 protection.
List of Standards Covered*: IEC 600790 (Ed.4.0); IEC 600791 (Ed. 5)
Issuing ExTL*: BKI Testing Station for Explosion Proof Equipment
Endorsing ExCB*: BKI Testing Station for Explosion Proof Equipment
Manufacturer*: NUOVA A.S.P. S.r.l.
Via De Gasperi, 26
20090 Pantigliate (MI), Italy
Attachment:
Last modified: 21/02/2013 05.08.53 Copyright © IECIECEx 2015 , Geneva, Switzerland. All rights reserved.
IECEx Technical Report: HU/BKI/ExTR06.0013/03 details
ExTR :
Status*: Issued
ExTR Free Reference HU/BKI/11/P00810
Number*:
Last modified: 21/02/2013 05.08.33 Copyright © IECIECEx 2015 , Geneva, Switzerland. All rights reserved.