A metallurgical failure analysis was requested after an accident occurred during the construction of a
water tower. A mobile crane, located outside the water tower, was used to remove a water tank crane
boom, which had been used inside the water tower tank during construction. As removal of the crane
was proceeding, the internal crane boom bolts used to attach the three crane boom sections together
failed, resulting in the separation of one of the crane boom sections from the main crane boom.
J.E.I. Metallurgical, Inc. was retained to conduct visual and non-destructive examination on the failed
crane's bolts, nuts, bolts fragments, fractures and metallographic mounts previously prepared by other
investigators. Visual examination of a come-along and broken come-along chain was also requested. The
come-along had been used to stabilize the internal crane boom during the removal process. The
question, which failure occurred first had to be addressed. Did the bolts fail first, allowing the come-
along to break thus causing the accident, or did the come-along fail first allowing the internal crane
boom to slide and fall vertically, causing the crane boom bolts to fail?
Photograph A. Bolt that failed in a pure tensile ductile dimple rupture mode.
Threads on one bolt/nut combination were actually stripped, illustrating improper assembly of the
derrick boom. A close-up view of the nut, with stripped threads, is shown in Photograph B.
During the accident reconstruction, it was determined that the come-along chain failed first. As a result
of the come-along chain failure, the bolts holding each crane section failed in a variety of fracture
modes. Thus, the final separation of the derrick boom sections occurred as a result of failure of the
section attachment bolts from stresses applied as the subject crane boom dropped and struck the water
tank wall.