Rick Henry
Courtesy of University of Auckland, Faculty of Engineering
USAR
• DBH / MBIE:
Practice Advisory 13 - Egress Stairs
• EQ reverses &
pulls stair off the
landing
Detailing of Precast Cladding, Flooring Systems &
Stairs for Multi-Storey Buildings – September 2015
Forsyth Barr
12
Grand chancellor
Steel corbels
Lower end sliding in side pocket Upper end sliding in seating member
Detailing of Precast Cladding, Flooring Systems &
Stairs for Multi-Storey Buildings – September 2015
Stairs and Ramps – more common
Sp = 0.7
Assume tolerances of 20 mm
Unarmoured ledge:
Armoured ledge: 232 mm + bearing width
232 mm + bearing width + allowance for spalling
Detailing of Precast Cladding, Flooring Systems &
Stairs for Multi-Storey Buildings – September 2015
Retrofit of Existing Stairs
• Lower half
supported and
braced by the
lower floor
• Lower half
supported and
braced by the
lower floor