Вы находитесь на странице: 1из 58

S2750&S5700&S6700 Series Ethernet Switches

V200R003C00SPC300
Upgrade Guide

Issue 03

Date 2013-12-30

HUAWEI TECHNOLOGIES CO., LTD.


Copyright © Huawei Technologies Co., Ltd. 2013. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior
written consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions

and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.

Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees
or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.

Huawei Technologies Co., Ltd.


Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China

Website: http://enterprise.huawei.com

Issue 03 (2013-12-30) Huawei Proprietary and Confidential i


Copyright © Huawei Technologies Co.,
Ltd
前 言

About This Document

Overview
This document guides you through the upgrade, rollback, and troubleshooting procedures for
S2750&S5700&S6700 Series Ethernet Switches V200R003C00SPC300.

Intended Audience
This document is intended for engineers who:
 Understand how involved network elements (NEs) are networked and what versions they
are.
 Have equipment maintenance experience and skills.

Symbol Conventions
The symbols that may be found in this document are defined as follows.

Symbol Description

Alerts you to a high risk hazard that could, if not avoided,


result in serious injury or death.

Alerts you to a medium or low risk hazard that could, if not


avoided, result in moderate or minor injury.

Alerts you to a potentially hazardous situation that could, if not


avoided, result in equipment damage, data loss, performance
deterioration, or unanticipated results.
Provides a tip that may help you solve a problem or save time.
Provides additional information to emphasize or supplement
important points in the main text.

Issue 03 (2013-12-30) Huawei Proprietary and Confidential ii


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches
Upgrade Guide About This Document

Change History
Issue Date Description

03 2013-12-30 This version has the following updates:


1.3 Cautionary Notes Before the Upgrade
02 2013-07-25 This version has the following updates:
1.3 Cautionary Notes Before the Upgrade
01 2013-05-30 This issue is the first official release.

Issue 03 (2013-12-30) Huawei Proprietary and Confidential iii


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches
Upgrade Guide Contents

Contents

About This Document....................................................................................................................ii


1 Before You Start.............................................................................................................................1
1.1 Version Requirements Before Upgrade.............................................................................................................1
1.2 Impact of Patch Installation...............................................................................................................................2
1.3 Impact on the System During Installation.........................................................................................................2
1.1.1 Impact on the System After Installation...................................................................................................3
1.4 Cautionary Notes Before the Upgrade...............................................................................................................3

2 Upgrade Process.............................................................................................................................9
2.1 Upgrade Flowchart............................................................................................................................................9

3 Preparations for Upgrade...........................................................................................................10


3.1 Preparation Checklist.......................................................................................................................................10
3.2 Checking the Current System Software Version..............................................................................................11
3.3 Checking the Running Status of the Device....................................................................................................11
3.4 Setting Up an Environment for the Upgrade...................................................................................................11
3.5 Obtaining Required Software for the Upgrade................................................................................................13
3.6 Backing Up the Key Data in the Flash Memory..............................................................................................14
3.7 Checking the Flash Memory Space.................................................................................................................14

4 Upgrade Operations on a Single Switch.................................................................................16


4.1 Upgrading the Switch to V200R003C00SPC300 Using the Command Line..................................................16
4.2 Upgrading the Switch to the V200R003C00SPC300 Using the BootROM....................................................28
4.2.1 Uploading the System Software.............................................................................................................29
4.2.2 Specifying the System Software to Be Loaded for Starting the Switch.................................................34
4.2.3 Restarting the Switch..............................................................................................................................36
4.3 Upgrading the Switch to V200R003C00SPC300 Using the USB Flash Drive...............................................36
4.3.1 Overview................................................................................................................................................36
4.3.2 Upgrading the Software Using the USB Flash Drive.............................................................................36

5 Upgrade Operations on a Stack................................................................................................41


5.1 Upgrading All Stack Member Switches to V200R003C00SPC300 by Using the Command Line.................41
5.2 Using the Intelligent Upgrade Function...........................................................................................................44
5.2.1 Overview................................................................................................................................................44

Issue 03 (2013-12-30) Huawei Proprietary and Confidential iv


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches
Upgrade Guide Contents

5.2.2 Upgrading a New Member Switch Using the Intelligent Upgrade Function.........................................44

6 Verifying the Upgrade................................................................................................................47


6.1 Verification Checklist.......................................................................................................................................47
6.2 Checking the Current System Software Version..............................................................................................47
6.3 Checking the Device Running Status..............................................................................................................48
6.4 Checking the System Configuration................................................................................................................48

7 Version Rollback.........................................................................................................................49
7.1 S2750&S5700&S6700 Version Rollback........................................................................................................49
7.1.1 Version Rollback Flowchart...................................................................................................................49
7.1.2 Loading the Previous System Software..................................................................................................50
7.1.3 Performing Version Rollback.................................................................................................................50
7.1.4 Verifying Version Rollback.....................................................................................................................50

Issue 03 (2013-12-30) Huawei Proprietary and Confidential v


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches
Upgrade Guide Before You StartBefore You Start

1 Before You Start

1.1 Version Requirements Before Upgrade


Table 1.1 Version requirements before upgrade

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 1


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches
Upgrade Guide Before You StartBefore You Start

Version Upgrade Instruction

S5700: This version can be directly upgraded to


V100R005C01SPC100 V200R003C00SPC300.
V100R006C00SPC300
V100R006C00SPC500
V100R006C00SPC600
V100R006C00SPC800
V100R006C01
V100R006C01SPC100
V200R001C00SPC100
V200R001C00SPC200
V200R001C00SPC300
V200R001C01
V200R001C01SPC100
V200R002C00
V200R002C00SPC100

S6700:
V100R006C00SPC300
V100R006C00SPC500
V100R006C00SPC600
V100R006C00SPC800
V200R001C00SPC100
V200R001C00SPC200
V200R001C00SPC300
V200R001C01
V200R001C01SPC100
V200R002C00
V200R002C00SPC100

1.2 Impact of Patch Installation


Before you upgrade an earlier version to the V200R003C00SPC300, read this chapter
carefully to understand the possible impacts of the upgrade on the existing system.

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 2


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches
Upgrade Guide Before You StartBefore You Start

1.3 Impact on the System During Installation


Impact on Services
The switch will restart during the upgrade and service will be interrupted.

The service interruption time depends on many factors, such as the system software size, upgrade
method, operator's skill, and service configurations. The following service interruption time is for your
reference.

In the following examples, the switches are not configured and they are not in any stack. In
addition, all these switches can provide the PoE function.
If the switches are upgraded by using the BootROM and the system software is uploaded
through the serial interface, the service interruption time is as follows (the baudrate is
115200):
 S2750: 50 minutes
 S5700: 50 minutes
 S6700: 47 minutes
If the switches are upgraded by using the BootROM and the system software is uploaded
through the network port (FTP mode), the service interruption time is as follows:
 S2750: 6 minutes
 S5700: 6 minutes
 S6700: 6 minutes
If the switches are upgraded by using the command line, the service interruption time is as
follows:
 S2750: 3 minutes
 S5700: 3 minutes
 S6700: 3 minutes

Impact on Network Communication


When the system restarts, the communication between the switch and the NMS is interrupted.
The communication interruption time is the same as the service interruption time.

1.3.1 Impact on the System After Installation


There is no adverse impact on the system.

1.4 Cautionary Notes Before the Upgrade


Consider the following cautionary points before performing the upgrade.

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 3


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches
Upgrade Guide Before You StartBefore You Start

No. Description

1 When you upgrade the software using the command line, stack upgrade, or USB
flash drive, do not copy or delete files.
2 After the version is upgraded, ensure that the configuration is saved because a
later version is compatible with early versions but an early version is
incompatible with later versions. If the configuration is not saved, the
configuration will be lost in the case of version rollback.
3 If the loopback local swap-mac or loopback remote swap-mac command has
been used on an interface in a version earlier than V200R003 to configure MAC
swap loopback, run the start command in the interface view after the upgrade;
otherwise, the MAC swap loopback configuration will be invalid.
4 After the arp learning dhcp-trigger command is used on a VLANIF interface
of the DHCP relay agent in V200R003, dynamic ARP entries are generated only
after DHCP snooping in the corresponding VLAN or on the physical interface
connected to users.
5 After a switch is upgraded from a version earlier than V100R006C00 to
V200R003C00SPC300 with no configuration performed on the switch, some
previously disabled alarms are disabled. These alarms include basetrap, lldptrap,
dldp, and loop-detection.
6 After a switch is upgraded from V100R003 or an earlier version to
V200R003C00SPC300, the default setting of the dot1x handshake function
changes from enabled to disabled. After the upgrade, the dot1x handshake
configuration has no buildrun information.
7 After a switch is upgraded from V100R002 or an earlier version to
V200R003C00SPC300, the value range and default value of the interval
parameter in the mac-authen timer guest-vlan reauthenticate-period
command change. In the old version, the value range of the interval parameter is
1–3600 and the default value is 30 (seconds). In the new version, the value range
is 60–3600 and the default value is 60 (seconds). If the interval has been set to a
value in the range of 1–59 seconds, the interval changes to 60 seconds after the
upgrade.
8 After a switch is upgraded from an earlier version to V200R001 or a later
version, the default aging time of ACLs used for ARP Miss suppression changes
from 50 seconds to 5 seconds.
9 After a switch is upgraded from a version earlier than V200R001C01 to
V200R003C00SPC300, the default setting of the icmp rate-limit enable
command changes from enabled to disabled. After the upgrade, the command
has no buildrun information.
10 After a switch is upgraded from an earlier version to V200R001 or a later
version, the default setting of the set flow-statistics include-interframe
command changes. In earlier versions, the traffic statistics collected on an
Ethernet interface do not include the inter-frame gap by default. In
V200R003C00SPC300 the traffic statistics collected on an Ethernet interface
include the inter-frame gap by default.

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 4


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches
Upgrade Guide Before You StartBefore You Start

No. Description

11 If DAI is enabled on a VLAN and an interface belonging to the VLAN using the
arp anti-attack check user-bind enable command, V200R001 and later
versions use a different rule than that used in earlier versions to check ARP
packets. In earlier versions, an ARP packet is considered valid as long as the
packet passes the check on the interface. In V200R001 and later versions, an
ARP packet is considered valid only when the packet passes the check on the
interface and VLAN.
12 After the switch is upgraded from V200R001C01 to V200R003C00SPC300, the
configuration of the traffic rate statistics collection timer in traffic policies
cannot be restored and the timer value is reset to the default value 300s. In
V200R003C00SPC300, run the traffic statistics interval interval-time
command to set this timer.
13 No buildrun information is displayed after an interface is shut down by loopback
detection. You can use the display interface or display loopback-detect
command to check the status of this interface. An interface cannot automatically
go Up after it is shut down by loopback detection. To restore the interface
without disabling loopback detection on the interface, run the shutdown and
undo shutdown commands or the restart command on the interface.
14 After an S5700-LI or S5710EI switch is upgraded from V200R001C00 to
V200R003C00SPC300 or a later version, its file system will expand from 64
MB to 200 MB. If the system rolls back to V200R001C00, the BootROM will
not be updated. It is highly recommended that you back up important files before
a degrade and limit the size of the files within 61 MB (3 MB reserved for system
software). If the size of files exceeds 61 MB, the system backs up the files in the
following order and discards excess files:
1. Software package for next startup: Sys_StartupFlagRec_S.szCurSwtFile
2. Configuration file for next startup: Sys_StartupFlagRec_S.szCfgFile
3. Patch file for next startup: Sys_PatchUpdateFlagRec_S.szNextPatchFile
4. Patch state file: flash:/$_patchstate_reboot
5. flash:/ *.web.zip
6. flash:/private-data.txt
7. flash:/$_patch_history
8. flash:/serverkey (if any, used for SSH login)
9. flash:/hostkey (if any, used for SSH login)
10. flash:/resetinfo
11. flash:/syslogfile
The system displays "do not power off" during update of the file system. Do not
power off or restart the switch in this process. Otherwise, all data on the switch
will be lost. If the device is powered off due to incorrect operation or for other
reasons, upgrade the software to V200R003C00SPC300 through BootROM
according to section 4.2 or contact Huawei technical support engineers.
15 To upgrade an S5700LI or S5710EI switch using the BootROM menu, upgrade
the BootROM to the latest version, download the latest software package, and
specify the software package for the next startup using the BootROM menu. To
roll back the system version of an S5700LI or S5710EI switch, specify the old
software packet for next startup while retaining the latest BootROM version.

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 5


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches
Upgrade Guide Before You StartBefore You Start

No. Description

16 If a switch has no management interface, enter the BIOS menu and use the first
electrical interface to transfer the software package to the switch. Errors may
occur if you use other interfaces to transfer the software package.
17 If an 5700SI or 5700LI switch has been configured with the maximum number
of ACL CAR entries and inbound rate limiting before it is upgraded to
V200R003C00SPC300, the ACL CAR configuration may be lost after the
upgrade due to insufficient resources for ACL CAR entries.
18 After the system is upgraded to V002R002C00 or a later version, the default
temperature alarm threshold and value range will change. If the temperature
alarm threshold configured in the old version is out of the value range in the new
version, the threshold will change to the default value after the upgrade.
19 If the system version rolls back to an earlier version from V200R002C00 or a
later version, the stack configuration may be lost. When this occurs, the stack
cannot be set up. To set up a stack, reconfigure the stacking function and re-
connect stack cables if necessary.
For example, S5700-LI V200R002C00 adds to stack ports. If the two ports are
used for stacking, the stack cannot be set up after the system version rolls back to
an earlier version.
20 During BootROM update, the XMODEM protocol is transmitted at 128 bit/s. If
the size of a packet is not a multiple of 128 bits, the packet size increases. After
the stack reboots, configurations cannot be restored because the packet size
changes. It is recommended that you download the system software package
through FTP or TFTP.
21 V200R002C00C00SPC100 does not support HGMP. After the software is
upgraded to V200R002C00C00SPC100 or a later version, the HGMP
configuration will be lost.
22 V200R003C00SPC300 supports a maximum of 30000 commands. If more than
30000 commands are executed, some commands may become invalid after
software upgrade.
23 During software degrade, if the system displays "Info: After the system version
is changed successfully, it can only be changed to V200R002C00 or later in next
version change.", do not change the version to V200R001 or an earlier version.
If the system displays "Error: The system cannot be degraded to this version.
Please use V100R006 or a later version.", use V100R006 or a later version.
24 After the trap function is enabled or disabled on V100R006C00, the snmp-agent
trap enable basetrap command is not supported. After the system software is
upgraded to V100R006C00 or a later version, the configuration of the snmp-
agent trap enable basetrap command will be lost. The trap function is not
affected.
25 When the software version is degraded to be earlier than V200R002C00, the
BootROM is not automatically upgraded. After the version is degraded, it cannot
be upgraded again. The S5700EI is not limited by this rule. The software version
of S5700SI cannot be degraded from V200R002C00 to V100R006 or an earlier
version.

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 6


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches
Upgrade Guide Before You StartBefore You Start

No. Description

26 After the software version is degraded or upgraded to any version through the
USB flash drive, index file verification may be failed. A formal patch must be
installed to solve this problem.
27 Before upgrading or degrading V200R002C00C00SPC100 to any version
through the USB flash drive, check whether a password has been set on the
device using the set device usb-deployment password XXXXXX command. If a
password has been set, add <usb-deployment password=XXXXXX;/> to the
index file on the USB flash drive for password authentication. The password in
the index file is in plain text, and cannot contain semicolons because semicolons
are separators in the index file. Authentication can be successful only when the
password in the index file is the same as that on the device. If no password is set
on the device, the password or field can be filled in the index file or not.
28 If the BFD negotiation time set in V100R002 is shorter than 100
ms, the setting of BFD negotiation time is lost after the software
version is upgraded to V200R003.

29 After the software version is upgraded to V200R003C00SPC300,


the tunnel interface format is changed from Tunnel x/x/x to
Tunnel x.

30 In V200R001C01, the range of NQA server port numbers is


changed from 1-65535 to 7 and 1025-65535. Therefore, if the
NQA server port number has been set to 1-6 or 8-1024 before
the upgrade is performed, the configuration will be lost after the
upgrade.

31 After the software version is upgraded to V200R003C00SPC300, the BIOS


password set in the earlier version is still valid; however, it is recommended that
you change the password to ensure security.
32 After the software version is upgraded to V200R003C00SPC300, the local
account password set in the earlier version is still valid; however, it is
recommended that you change the password to ensure security.
33 If a physical stack port is not bound to a logical stack port before the upgrade,
the port restores to a service port after the version is upgraded to
V200R003C00SPC300.
34 After V200R003C00SPC300 is degraded to V200R001 or an earlier version, the
stack features on stack ports are disabled, and the stack ports must be
reconfigured.
35 The qos queue statistics enable command is deleted from
V200R003C00SPC300 and later versions. After the version is upgraded to
V200R003C00SPC300, the switch supports queue statistics by default.
36 After the version is upgraded to V200R003, if the packets discarded by IP source
guard match a traffic policy in which the action is mirroring, the traffic mirroring
function does not take effect on the packets.

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 7


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches
Upgrade Guide Before You StartBefore You Start

No. Description

37 After the software version is upgraded to V200R003, the default settings and
value ranges of rate limit on the management port are changed. If the rate limit
before the upgrade is beyond the value range allowed by V200R003, the rate
limit is changed to the maximum value in V200R003. If the rate limit before the
upgrade is the same as the default value in V200R003, the buildrun is deleted.
38 After the software version is upgraded to V200R003, the default settings and
value ranges of cp-car total pps packets are changed. If the rate limit before the
upgrade is beyond the value range allowed by V200R003, the rate limit is
changed to the maximum value in V200R003. If the rate limit before the upgrade
is the same as the default value in V200R003, the buildrun is deleted.
39 The software version is upgraded to V200R002 or a later version. If the ipv6
enable command has not been executed on the interface where dhcpv6 relay is
configured, the DHCPv6 relay configuration will be lost after the upgraded.
40 After the software version is upgraded to V200R001 or a later version, the local
user password may fail to restore. It is recommended that you upgrade the
software to V100R006 first, and then upgrade it to V200R001 or a later version.
Alternatively, you can delete the user account before the upgrade, reconfigure
and save the user account, and upgrade the software.
41 If the software already have patches installed, you do not need to delete the
patches before the upgrade. After the upgrade is complete, the original patches
are not activated.
Run the startup patch command to specify the patch for next startup before the
upgrade.
42 After the stack upgrade is complete, you only need to install the patch on the
master device.
43 The V200R003C00SPC300 does not support setting queue numbers for
protocol packets. After the software is upgraded to V200R003C00SPC300,
the configuration of queue packet-type packet-type queue-value is lost.

44 The V200R003C00SPC300 does not support limiting the number of packets


sent to the CPU within a certain period. After the software is upgraded to
V200R003C00SPC300, the configuration of cp-car { total | queue queue-
index } speed speed-value is lost.

45 The V200R003C00SPC300 does not support the function of setting the


maximum rate of sending packets to the CPU. After the software version is
upgraded to V200R003C00SPC300, the configuration of cp-car { total |
queue queue-index } speed speed-value is lost.
46 The Smart Link group in V200R003C00SP300 cannot communicate with the
Smart Link groups of earlier versions through SHA encryption. To enable the
Smart Link groups to communicate with each other, use non-encryption or
simple encryption mode.
47 After an earlier version is upgraded to V200R003C00SP300, the SHA
encryption password of the Smart Link saved in configuration file will be invalid
and needs to be reconfigured.

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 8


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches
Upgrade Guide Before You StartBefore You Start

No. Description

48 In a version earlier than V200R003C00SPC300, if a user name is configured in


the MAC address format for MAC address authentication and the AAA
authentication scheme is local authentication, the online users are not affected
after the version is upgraded to V200R003C00SPC300. However, for new users,
run mac-authen username macaddress format { with-hyphen | without-
hyphen } password cipher password to modify configuration and local-user
user-name password cipher password to reconfigure the accounts and
passwords for old users; otherwise, old users cannot go online again.
49 In V100R006 and later versions, GE ports do not support the automatic
downspeeding function. After the software is upgraded from an earlier
version to V100R006, the GE port may fail to perform auto-negotiation with the
PC. If this situation occurs, replace the network cable or run the auto speed { 10
| 100 } command to manually set the negotiation speed for the electrical port.

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 9


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches
Upgrade Guide Upgrade ProcessUpgrade Process

2 Upgrade Process

2.1 Upgrade Flowchart


Figure 1.1 Upgrade flowchart

Start

Preparation See chapter 3


Yes
Upgrade See chapters 4 and 5

Yes
No
Verification See chapter 6 Rollback See chapter 7
Yes

End

In the following chapters, the version is upgraded to V200R003C00SPC300.

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 10


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches
Upgrade Guide Preparations for UpgradePreparations for Upgrade

3 Preparations for Upgrade

3.1 Preparation Checklist


Table 1.1 Upgrade preparation checklist
No. Item Check Point Result

1 Check the system software The system software version is


version between V100R005C01SPC100 and
V200R003C00SPC300.
2 Check the running status of The switch functions normally.
the device
3 Set up an environment for the An environment is set up for the
upgrade upgrade as required.
4 Obtain required software for Software required for the upgrade is
the upgrade obtained.
5 Verifying the MD5 code of The MD5 code generated by the MD5
the system software checker is the same as the MD5 code
provided in the version file.
6 Back up the key data in the All the key data in the flash memory is
flash memory backed up.
7 Check the available space in The space in the flash memory is
the flash memory sufficient for storing the system
software package and other files such
as patch files and configuration files.

You can use an MD5 checker to verify a version file.


1. Download an MD5 checker from the Internet and run it.
2. Open the version file you want to check and generate an MD5 code using the MD5 checker.
3. Check whether the generated MD5 code is the same as the MD5 code provided in the version file.

In the following sections, the S5700EI is used as an example to describe the upgrade.

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 11


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches
Upgrade Guide Preparations for UpgradePreparations for Upgrade

3.2 Checking the Current System Software Version


Run the display version command to view the version of the system software.
<Quidway> display version
Huawei Versatile Routing Platform Software
VRP (R) software, Version 5.120 (S5700 V200R002C00SPC100)
Copyright (C) 2000-2012 HUAWEI TECH CO., LTD
Quidway S5700-28C-PWR-EI Routing Switch uptime is 0 week, 0 day, 0 hour, 29 minu
tes

CX22EFGEE 0(Master) : uptime is 0 week, 0 day, 0 hour, 29 minutes


256M bytes DDR Memory
32M bytes FLASH
Pcb Version : VER A
Basic BOOTROM Version : 160 Compiled at Dec 18 2012, 16:07:05
CPLD Version : 79
Software Version : VRP (R) Software, Version 5.120 (V200R002C00)
FANCARD I information
Pcb Version : FAN VER B
PWRCARD I information
Pcb Version : N/A VER N/A

In the preceding output, S5700 V200R002C00SPC100 indicates the version of system


software currently running on the S5700. If this is the target version, you do not need to
perform the upgrade.

3.3 Checking the Running Status of the Device


Run the display device command to check the switch running status. If the value of Status is
Normal, the device can be upgraded.
<Quidway> display device
S5752C-EI's Device status:
Slot Sub Type Online Power Register Status Role
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0 - 5752C Present PowerOn Registered Normal Master
3 FAN Present PowerOn Registered Normal NA
4 POWER Present PowerOn Registered Normal NA

3.4 Setting Up an Environment for the Upgrade


Setting Up an Environment for Upgrading the System Using TFTP or FTP
In the BootROM menu or the command line view, you can use the Trivial File Transfer
Protocol (TFTP) or File Transfer Protocol (FTP) to download the system software, and set it
as the next startup system software. Then restart the device to complete the upgrade. Figure 1.
1 shows the network diagram for setting up an environment for upgrading the system using
FTP or TFTP.
The general requirements for setting up an environment for upgrading the system using TFTP
or FTP are as follows:

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 12


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches
Upgrade Guide Preparations for UpgradePreparations for Upgrade

 You can log in to the switch from a PC through the serial interface or Telnet.
 The server and the switch can communicate with each other.
 Files for the upgrade are stored in the server.

Figure 1.1 Network diagram of upgrading the system using TFTP or FTP

Setting Up an Environment for Upgrading the System Using Xmodem


You can upgrade the basic and advanced BootROM software using Xmodem in the basic
BootROM menu; you can upgrade the system software using Xmodem in the BootROM
menu. Figure 1.1 shows the network diagram for setting up an environment for upgrading the
system using Xmodem.
The general requirements for setting up an environment for upgrading the system using
Xmodem are as follows:
 The RS-232 serial interface on the PC and the console interface on the switch are
connected through a console cable.
 Files for the upgrade are stored on the PC.

Figure 1.1 Network diagram of upgrading the system using Xmodem

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 13


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches
Upgrade Guide Preparations for UpgradePreparations for Upgrade

3.5 Obtaining Required Software for the Upgrade


To obtain the required software for the upgrade, contact Huawei technical support personnel.

Table 1.1 Software for different upgrade methods


Upgrade Method Matching Software

Upgrading the version to System software


V200R003C00SPC300 using  S2750-EI: S2750-EI -V200R003C00SPC300.cc
the command line
 S5700-SI: S5700SI-V200R003C00SPC300.cc
 S5700-EI: S5700EI-V200R003C00SPC300.cc
 S5700-HI: S5700HI-V200R003C00SPC300.cc
 S5706: S5700-6TP-LI-V200R003C00SPC300.cc
 S5710EI: S5710EI-V200R003C00SPC300.cc
 S5700-X-LI:S5700-X-LI-V200R003C00SPC300.cc
 S5700-P-LI:S5700-P-LI-V200R003C00SPC300.cc
 S5700-10P-LI:S5700-10P-LI-V200R003C00SPC300.cc
 S5700S-LI: S5700S-LI-V200R003C00SPC300.cc
 S6700: S6700EI-V200R003C00SPC300.cc
Upgrading the version to BootROM
V200R003C00SPC300 using  S2750-EI: S2750-EI_bootrom.bin
BootROM
 S5700-EI: S5700EI_bootrom.bin
 S5700-HI: S5700HI-bootrom.bin
 S5710EI: S5710EI-bootrom.bin
 S5700-X-LI: S5700-X-LI-bootrom.bin
 S5700-P-LI: S5700-P-LI-bootrom.bin
 S5700-10P-LI: S5700-10P-LI-bootrom.bin
 S5700S-LI: S5700S-LI-bootrom.bin
 S6700: S6700EI-bootrom.bin
System software
 S2750-EI: S2750-EI -V200R003C00SPC300.cc
 S5700-SI: S5700SI-V200R003C00SPC300.cc
 S5700-EI: S5700EI-V200R003C00SPC300.cc
 S5700-HI: S5700HI-V200R003C00SPC300.cc
 S5710EI: S5710EI-V200R003C00SPC300.cc
 S5700-X-LI:S5700-X-LI-V200R003C00SPC300.cc
 S5700-P-LI: S5700-P-LI -V200R003C00SPC300.cc
 S5700-10P-LI:S5700-10P-LI-V200R003C00SPC300.cc
 S5700S-LI: S5700S-LI-V200R003C00SPC300.cc
 S6700: S6700EI-V200R003C00SPC300.cc

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 14


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches
Upgrade Guide Preparations for UpgradePreparations for Upgrade

3.6 Backing Up the Key Data in the Flash Memory


You must back up the key data stored in the flash memory before the upgrade. You can
download the data that needs to be backed up to the PC through FTP or TFTP. After the
upgrade, you can reload the backup files to the flash memory. For details, see 4.1 Upgrading
the Switch to V200R003C00SPC300 Using the Command Line.

3.7 Checking the Flash Memory Space


Step 2 Run the dir command in the user view to check whether the flash memory space is sufficient
for the system software. If a stack is established, ensure that all the members in the stack have
enough space.
The preceding information shows that there is 4,544 KB space. If there is enough space,
ignore step 3.
<Quidway> dir
Directory of flash:/

Idx Attr Size(Byte) Date Time FileName


0 -rw- 11,065,564 Nov 02 2010 15:44:50 S5700EI-V200R002C00SPC100.cc
1 -rw- 1,998 Oct 13 2011 07:57:22 private-data.txt
2 -rw- 3,284 Oct 13 2011 07:57:07 vrpcfg.zip
3 -rw- 11,177,996 Nov 04 2010 16:10:03 s-s5700.cc

30,008 KB total (4,544 KB free)

Step 3 (Optional) Load and activate the patch file s5700-v200r002sph001.pat.

If no system software is stored on the device, do not restart or power cycle the device during
the upgrade. Otherwise, the system may break down. If the device is powered off
unexpectedly during the upgrade, use the BootROM to upgrade the device. If the upgrade
using BootROM fails, contact Huawei engineers.

Step 4 Run the delete command to delete unnecessary files to ensure there is enough space for
storing relevant upgrade files. Before deleting the unnecessary files, ensure that the files are
backed up or are unwanted. The following is an example of deleting the s-s5700.cc file. For
details, see "Managing the File System" in the S2750&S5700&S6700 Series Ethernet
Switches Configuration Guide – Basic Configurations.

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 15


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches
Upgrade Guide Preparations for UpgradePreparations for Upgrade

After you run the delete /unreserved command to delete a file from the flash, the file cannot
be restored; therefore, run this command with caution, and a file backup is recommended.

<Quidway> delete /unreserved s-s5700.cc


Warning: The contents of file flash:/s-s5700.cc cannot be recycl
ed. Continue? [Y/N]:y
Info: Deleting file flash:/s-s5700.cc...succeeded.

----End

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 16


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a Single SwitchUpgrade
Upgrade Guide Operations on a Single Switch

4 Upgrade Operations on a Single Switch

4.1 Upgrading the Switch to V200R003C00SPC300 Using


the Command Line
The command line upgrade method has little impact on services; therefore, you are advised to
upgrade an operating device by using the command line.

Purpose To upgrade the system software

Impact Services are interrupted when the device restarts.

Time In the scenario where a single device is configured and service


Required deployment is simple, services are interrupted about three minutes. In
the scenario where service deployment is complicated, the service
interruption time increases and the time depends on the complexity of
service.
Requirements  The switch that runs system software of an earlier version functions
properly.
 The available space in the flash memory is sufficient for storing the
system software.

 The methods of upgrading the system software using command line are similar on the S2750,S5700,
and the S6700. In the following description, the system software of the S5700EI is upgraded.
 The S5700/S6700 has a dedicated management interface, MEth. The MEth interface can be used as
the Layer 3 interface.
 Before the upgrade, use the terminal monitor command to enable the terminal to display logs,
traps, and debugging information sent from the information center.

You can use any of the following methods to load the system software:
 Use the S5700EI as the TFTP client.
 Use the S5700EI as the FTP server.
 Use the S5700EI as the FTP client.
 Use the S5700EI as the SFTP client

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 17


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a Single SwitchUpgrade
Upgrade Guide Operations on a Single Switch

FTP and TFTP are insecure. SFTP is recommended.

Method 1: Use the S5700EI as the TFTP Client

No TFTP client software is installed on the S5700EI; therefore, the customer needs to buy TFTP client
software and install it. The TFTP32 program is recommended.

Step 1 Configure the TFTP server.


Run the TFTP server program on the PC and configure the PC:
 Click Browse to set the directory for storing the new system software.
 The TFTP server address in Server interface is automatically set by the system, for
example, 10.164.30.29. However, if the IP address is incorrect you can manually change
it.

Do not stop the TFTP server program when you are backing up data.

Step 2 Back up the system software, configuration file, and patch files to the TFTP server.
Before the backup, check the size of the configuration file. After the backup, compare the size
of the original file with the size of the backup file. Ensure that the two files are the same size.
<Quidway> dir *.cc
Directory of flash:/

Idx Attr Size(Byte) Date Time FileName


0 -rw- 11,065,564 Nov 02 2010 15:44:50 S5700EI-V200R002C00SPC100.cc

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 18


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a Single SwitchUpgrade
Upgrade Guide Operations on a Single Switch

30,008 KB total (19,032 KB free)


<Quidway> dir *.zip
Directory of flash:/

Idx Attr Size(Byte) Date Time FileName


0 -rw- 3,284 Oct 13 2011 07:57:07 vrpcfg.zip

30,008 KB total (19,032 KB free)


<Quidway> dir *.pat
Directory of flash:/

Idx Attr Size(Byte) Date Time(LMT) FileName


0 -rw- 90,602 Nov 04 2010 16:10:03 s5700-v200r002sph001.pat

30,008 KB total (19,032 KB free)

Run the following commands on the S5700EI to back up the data. The backup system
software is S5700EI-V200R002C00SPC100-bak.cc, the backup configuration file is vrpcfg-
bak.zip, and the patch file is s5700-v200r002sph001-bak.pat.
<Quidway> tftp 10.164.30.29 put S5700EI-V200R002C00SPC100.cc S5700EI-
V200R002C00SPC100-bak.cc
Info: Transfer file in binary mode.
Uploading the file to the remote TFTP server. Please wait...|
TFTP: Uploading the file successfully.
11065564 bytes send in 91 seconds.
<Quidway> tftp 10.164.30.29 put vrpcfg.zip vrpcfg-bak.zip
Info: Transfer file in binary mode.
Uploading the file to the remote TFTP server. Please wait.../
TFTP: Uploading the file successfully.
3284 bytes send in 0.01 second.
<Quidway> tftp 10.164.30.29 put s5700-v200r002sph001.pat s5700-v200r002sph001-
bak.pat
Info: Transfer file in binary mode.
Uploading the file to the remote TFTP server. Please wait...\
TFTP: Uploading the file successfully.
90602 bytes send in 1 second.

Step 3 Obtain the system software of the target version from the server.
<Quidway> tftp 10.164.30.29 get S5700EI-V200R003C00SPC300.cc
Info: Transfer file in binary mode.
Downloading the file from the remote TFTP server. Please wait.../
TFTP: Downloading the file successfully.
14192640 bytes received in 93 seconds

If the message "Downloading the file successfully" is displayed, the system software has been
downloaded.
Step 4 (Optional) Obtain the new configuration file from the server.
If the configuration file does not need to be changed after the upgrade, this step is not
required.
<Quidway> tftp 10.164.30.29 get vrpcfgnew.zip
Info: Transfer file in binary mode.
Downloading the file from the remote TFTP server. Please wait.../

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 19


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a Single SwitchUpgrade
Upgrade Guide Operations on a Single Switch

TFTP: Downloading the file successfully.


2757 bytes received in 1 second.

Step 5 Specify the system software in service, which is loaded when the S5700EI is started.
<Quidway> startup system-software S5700EI-V200R003C00SPC300.cc
.cc

If the following information is displayed after you run the startup system-software file command, enter
Y to update the BootROM. If the BootROM is upgraded successfully, go to step 7; otherwise, go to step
6.
Warning: Basic BOOTROM will be upgraded. Continue?(Y/N)[N]: y
BOOTROM begin to be upgraded ! please wait for a moment...

Info: BOOTROM upgrade is ok.


Succeeded in setting the software for booting system.

Step 6 (Optional) Upgrade the BootROM in service, which is loaded when the S5700EI is started.
<Quidway> system-view
[Quidway] upgrade basic-bootrom S5700EI-V200R003C00SPC300.cc
Confirm basic BOOTROM will be upgrade?(Y/N)[N]: y
BOOTROM begin to upgraded ! please wait for a minute...

Info: BOOTROM upgrade is ok.


Succeeded in setting the software for booting system.

In the V100R005 or a later version, the BootROM is upgraded automatically. To upgrade the software to
other versions, you must upgrade the BootROM manually. For details about automatic BootROM
upgrade, see Step 5. In the case of a version rollback, you are advised to manually upgrade the
BootROM to prevent a rollback failure

Step 7 Restart the S5700EI.

After the software is upgraded to V200R003C00SPC300, you must specify the system software for next
startup. If the system software is not specified or the invalid software is specified, the device will fail to
restart. For details about specifying the system software for next startup, see Step 5.

When the system asks you whether to save the configuration, enter y or n. After the setting is
complete, enter y to restart the system.
<Quidway> reboot
Info: The system is now comparing the configuration, please wait.
Warning: The configuration has been modified, and it will be saved to the next s
tartup saved-configuration file flash:/105_xu.cfg. Continue? [Y/N]:y
Now saving the current configuration to the slot 0....
Save the configuration successfully.
Info: If want to reboot with saving diagnostic information, input 'N' and then e
xecute 'reboot save diagnostic-information'.
System will reboot! Continue?[Y/N]:y
Info: System is rebooting, please wait.

----End

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 20


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a Single SwitchUpgrade
Upgrade Guide Operations on a Single Switch

Method 2: Use the S5700EI as the FTP Server

No FTP server software is installed on the S5700EI; therefore, the customer needs to buy FTP server
software and install it.

Step 1 Configure the S5700EI as an FTP server.


Start the FTP server on the S5700EI, and set the FTP user name to ftpuser and password to
admin@123456.
<Quidway> system-view
[Quidway] ftp server enable
[Quidway] aaa
[Quidway-aaa] local-user ftpuser password cipher admin@123456
[Quidway-aaa] local-user ftpuser privilege level 3
[Quidway-aaa] local-user ftpuser service-type ftp
[Quidway-aaa] local-user ftpuser ftp-directory flash:
[Quidway-aaa] return

The user level must be set to 3 or upper levels to ensure successful connection establishment.

Step 2 Set an IP address for the S5700EI.


An idle service interface is recommended. This example assumes that GigabitEthernet/0/0/1 is
used and the IP address is 1.1.1.1/24.
<Quidway> system-view
[Quidway]interface GigabitEthernet 0/0/1
[Quidway-GigabitEthernet0/0/1]port link-type access
[Quidway-GigabitEthernet0/0/1]quit
[Quidway] vlan 10
[Quidway-vlan10] port GigabitEthernet 0/0/1
[Quidway-vlan10] quit
[Quidway] interface vlanif 10
[Quidway-Vlanif10] ip address 1.1.1.1 24
[Quidway-Vlanif10] quit
[Quidway]

Step 3 Log in to the FTP server (the S5700EI).

Assume that the Windows XP operating system is used.

Store the file to be uploaded in the specified directory (for example, D:\>directory). Choose
Start > Run. Enter cmd and press Enter. Enter FTP 1.1.1.1. Enter the user name at the user
prompt and the password at the password prompt, and then press Enter. The following
information is displayed:
D:\>ftp 1.1.1.1
Connected to 1.1.1.1.
220 FTP service ready.
User (1.1.1.1:(none)): ftpuser
331 Password required for 1.
Password:
230 User logged in.
ftp>

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 21


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a Single SwitchUpgrade
Upgrade Guide Operations on a Single Switch

Step 4 Back up the system software, configuration file, and patch files.
ftp> binary
200 Type set to I.
ftp> get S5700EI-V200R002C00SPC100.cc
200 Port command okay.
150 Opening BINARY mode data connection for directory list.
226 Transfer complete.
ftp: 11065564 bytes received in 80.33Seconds 1350.65Kbytes/sec.

The preceding output indicates the configuration file has been transferred and you can find it
in D:\>.
ftp> get vrpcfg.zip
200 Port command okay.
150 Opening BINARY mode data connection for vrpcfg.zip
226 Transfer complete.
ftp: 589 bytes received in 0.01Seconds 60Kbytes/sec.

The preceding output indicates the configuration file has been transferred and you can find it
in D:\>.
ftp> get s5700-v200r002sph001.pat
200 Port command okay.
150 Opening BINARY mode data connection for directory list.
226 Transfer complete.
ftp: 333436 bytes received in 0.25Seconds 1333.74Kbytes/sec.

The preceding output indicates the configuration file has been transferred and you can find it
in D:\>.
Step 5 Upload the system software for the S5700EI.
Run the put source-filename [ destination-filename ] command on the FTP client (PC) to
upload the system software from the PC.
ftp> put S5700EI-V200R003C00SPC300.cc
200 Port command okay.
150 Opening BINARY mode data connection for directory list.
226 Transfer complete.
ftp: 14192640 bytes in 87.10Seconds 140.76Kbytes/sec.
ftp>

Step 6 (Optional) Upload the new configuration file to the S5700EI.


If the configuration file does not need to be changed after the upgrade, this step is not
required.
ftp> put vrpcfgnew.zip

Step 7 Specify the system software in service, which is loaded when the S5700EI is started.
<Quidway> startup system-software S5700EI-V200R003C00SPC300.cc

If the following information is displayed after you run the startup system-software file command, enter
Y to update the BootROM. If the BootROM is upgraded successfully, go to step 9; otherwise, go to step
8.
Warning: Basic BOOTROM will be upgraded. Continue?(Y/N)[N]: y
BOOTROM begin to be upgraded ! please wait for a moment...

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 22


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a Single SwitchUpgrade
Upgrade Guide Operations on a Single Switch

Info: BOOTROM upgrade is ok.


Succeeded in setting the software for booting system.

Step 8 (Optional) Upgrade the BootROM in service, which is loaded when the S5700EI is started.
<Quidway> system-view
[Quidway] upgrade basic-bootrom S5700EI-V200R003C00SPC300.cc
Warning: Basic BOOTROM will be upgraded. Continue?(Y/N)[N]: y
Upgrading BOOTROM,please wait for a moment...

[Slot 0]:
Info: BOOTROM upgrade is ok.

In the V100R005 or a later version, the BootROM is upgraded automatically. To upgrade the software to
other versions, you must upgrade the BootROM manually. For details about automatic BootROM
upgrade, see Step 7. In the case of a version rollback, you are advised to manually upgrade the
BootROM to prevent a rollback failure

Step 9 Restart the S5700EI.

After the software is upgraded to V200R003C00SPC300, you must specify the system software for next
startup. If the system software is not specified or the invalid software is specified, the device will fail to
restart. For details about specifying the system software for next startup, see Step 7.

When the system asks you whether to save the configuration, enter y or n. After the setting is
complete, enter y to restart the system.
<Quidway> reboot
Info: The system is now comparing the configuration, please wait.
Warning: The configuration has been modified, and it will be saved to the next s
tartup saved-configuration file flash:/105_xu.cfg. Continue? [Y/N]:y
Now saving the current configuration to the slot 0....
Save the configuration successfully.
Info: If want to reboot with saving diagnostic information, input 'N' and then e
xecute 'reboot save diagnostic-information'.
System will reboot! Continue?[Y/N]:y
Info: System is rebooting, please wait.

----End

Method 3: Use the S5700EI as the FTP Client

No FTP client software is installed on the S5700EI; therefore, the customer needs to buy FTP client
software and install it.

Step 1 Configure the PC as the FTP server.


Run an FTP server program on the PC, for example, wftpd32. Choose Security >
Users/rights.

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 23


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a Single SwitchUpgrade
Upgrade Guide Operations on a Single Switch

Click New User to set the user name and password. Here, the user name is S5700 and the
password is admin@123456. Enter the FTP root directory in the Home Directory text box.
Here, the root directory is D:\ftp. Click Done to close the dialog box.
Do not stop the FTP server program when you are backing up data.
Step 2 Back up the system software, configuration file, and patch files.
The FTP commands on the S5700EI are the same as the FTP commands in the DOS system.
Assume that the IP address of the FTP server is 10.164.30.27, the FTP user name is S5700,
and the password of the FTP user is admin@123456.
<Quidway> cd flash:/
<Quidway> ftp 10.164.30.27
Trying 10.164.30.27 ...
Press CTRL+K to abort
Connected to 10.164.30.27.
220 WFTPD 2.0 service (by Texas Imperial Software) ready for new user
User(10.164.30.27:(none)):S5700 # Enter the user name and press Enter.
331 Password required for aaa
Enter password: # Enter the password admin@123456 and press Enter. The
password displayed on the screen is in cipher text.
230 User successfully logged in.

[ftp] binary
200 Type is Image (Binary)

Back up the system software S5700EI-V200R002C00SPC100.cc to the FTP server and


specify the name of the backup file as S5700EI-V200R002C00SPC100-bak.cc. If the name
of the backup file is not specified, the original name is used.
[ftp] put S5700EI-V200R002C00SPC100.cc S5700EI-V200R002C00SPC100-bak.cc
200 Port command successful.
150 Opening BINARY mode data connection for file transfer.
226 Transfer complete
FTP: 11065564 byte(s) sent in 81.176 second(s) 1296.55Kbyte(s)/sec.

Back up the configuration file vrpcfg.zip to the FTP server and specify the name of the
backup file as vrpcfg-bak.zip. If the name of the backup file is not specified, the original
name is used.
[ftp] put vrpcfg.zip vrpcfg-bak.zip
200 Port command successful.
150 Opening BINARY mode data connection for file transfer.

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 24


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a Single SwitchUpgrade
Upgrade Guide Operations on a Single Switch

226 Transfer complete


FTP: 1387 byte(s) sent in 0.176 second(s) 22.04Kbyte(s)/sec.

Back up the patch file s5700-v200r002sph001.pat to the FTP server and specify the name of
the backup file as s5700-v200r002sph001-bak.pat. If the name of the backup file is not
specified, the original name is used.
[ftp] put s5700-v200r002sph001.pat s5700-v200r002sph001-bak.pat
200 Port command okay
150 "D:\ftp\s5700-v200r002sph001-bak.pat" file ready to receive in IMAGE / Binary
mode
226 Transfer finished successfully.
FTP: 333436 byte(s) sent in 0.322 second(s) 1035.51Kbyte(s)/sec.

Step 3 Obtain the system software of the target version.


[ftp] get S5700EI-V200R003C00SPC300.cc
200 Port command successful.
150 Opening BINARY mode data connection for file transfer.
226 Transfer complete
FTP: 14,066,348 byte(s) received in 87.500 second(s) 1117.40Kbyte(s)/sec.

You can specify the filename of the upgrade program. If the filename is not specified, the
original name is used.
Step 4 (Optional) Obtain the new configuration file.
If the configuration file does not need to be changed after the upgrade, this step is not
required.
[ftp] get vrpcfgnew.zip

Step 5 Close the FTP connection.


[ftp] bye
221 Windows FTP Server (WFTPD, by Texas Imperial Software) says goodbye

Step 6 Specify the system software in service, which is loaded when the S5700EI is started.
<Quidway> startup system-software S5700EI-V200R003C00SPC300.cc

If the following information is displayed after you run the startup system-software file command, enter
Y to update the BootROM. If the BootROM is upgraded successfully, go to step 8; otherwise, go to step
7.
Warning: Basic BOOTROM will be upgraded. Continue?(Y/N)[N]: y
BOOTROM begin to be upgraded ! please wait for a moment...

Info: BOOTROM upgrade is ok.


Succeeded in setting the software for booting system.

Step 7 (Optional) Upgrade the BootROM in service, which is loaded when the S5700EI is started.
<Quidway> system-view
[Quidway] upgrade basic-bootrom S5700EI-V200R003C00SPC300.cc
upgrade basic-bootrom S5700EI-V200R003C00SPC300.cc
Warning: Basic BOOTROM will be upgraded. Continue? (Y/N): y
Upgrading BOOTROM,please wait for a moment...

[Slot 0]:

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 25


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a Single SwitchUpgrade
Upgrade Guide Operations on a Single Switch

Info: BOOTROM upgrade is ok.

In the V100R005 or a later version, the BootROM is upgraded automatically. To upgrade the software to
other versions, you must upgrade the BootROM manually. For details about automatic BootROM
upgrade, see Step 6. In the case of a version rollback, you are advised to manually upgrade the
BootROM to prevent a rollback failure.

Step 8 Restart the S5700EI.

After the software is upgraded to V200R003C00SPC300, you must specify the system software for next
startup. If the system software is not specified or the invalid software is specified, the device will fail to
restart. For details about specifying the system software for next startup, see Step 6.

When the system asks you whether to save the configuration, enter y or n. After the setting is
complete, enter y to restart the system.
<Quidway> reboot
Info: The system is now comparing the configuration, please wait.
Warning: The configuration has been modified, and it will be saved to the next s
tartup saved-configuration file flash:/105_xu.cfg. Continue? [Y/N]:y
Now saving the current configuration to the slot 0....
Save the configuration successfully.
Info: If want to reboot with saving diagnostic information, input 'N' and then e
xecute 'reboot save diagnostic-information'.
System will reboot! Continue?[Y/N]:y
Info: System is rebooting, please wait.

----End

Method 4: Use the S5700EI as the FTP Client

No SFTP server software is installed on the S5700EI; therefore, the customer needs to buy SFTP server
software and install it.

Step 1 Configure the S5700EI as an SFTP server.


Run the SFTP server, for example, the Core FTP mini-sftp-server, on the PC.

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 26


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a Single SwitchUpgrade
Upgrade Guide Operations on a Single Switch

Click User and set the user name and password. Here, the user name is 123 and the password
is 123. Enter the SFTP working directory, for example, D:\ftp. Do not stop the SFTP server
program when you are backing up data.
Step 2 Back up the system software, configuration file, and patch files.
The SFTP commands on the S5700EI are the same as the SFTP commands in the DOS
system. In this example, the SFTP server IP address is 10.138.112.38, the FTP user name is
123, and the password of the SFTP user is 123
<Quidway> cd flash:/
<Quidway> system-view
[Quidway]ssh client first-time enable
[Quidway]sftp 10.138.112.38
Please input the username:123
Trying 10.138.112.38 ...
Press CTRL+K to abort
Connected to 10.138.112.38 ...
The server is not authenticated. Continue to access it? [Y/N] :y
Save the server's public key? [Y/N] :y
The server's public key will be saved with the name 10.138.112.38. Please wait…
Enter password: # Enter the password.
sftp-client>
Back up the system software S5700EI-V200R002C00SPC100.cc to the SFTP server and set
the name of the backup file to S5700EI-V200R002C00SPC100-bak.cc. If the name of the
backup file is not specified, the original name is used.

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 27


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a Single SwitchUpgrade
Upgrade Guide Operations on a Single Switch

sftp-client>put S5700EI-V200R002C00SPC100.cc S5700EI-V200R002C00SPC100-bak.cc

local file: S5700EI-V200R002C00SPC100.cc ---> Remote file: / S5700EI-


V200R002C00SPC100-bak.cc

SuccessInfo: Uploading file successfully ended.

Back up the configuration file vrpcfg.zip to the SFTP server and specify the name of the
backup file as vrpcfg-bak.zip. If the name of the backup file is not specified, the original
name is used.
sftp-client> put vrpcfg.zip vrpcfg-bak.zip

local file: vrpcfg.zip ---> Remote file: / vrpcfg-bak.zip

SuccessInfo: Uploading file successfully ended.

Back up the patch file s5700-v200r002sph001.pat to the SFTP server and specify the name
of the backup file as s5700-v200r002sph001-bak.pat. If the name of the backup file is not
specified, the original name is used.
sftp-client> put S5700-v200r002sph001.pat s5700-v200r002sph001-bak.pat

local file: S5700-v200r002sph001.pat ---> Remote file: / s5700-v200r002sph001-


bak.pat

SuccessInfo: Uploading file successfully ended.

Step 3 Obtain the system software of the target version


sftp-client>get S5700EI-V200R003C00SPC300.cc

Remote file: / S5700EI-V200R003C00SPC300.cc ---> Local file: S5700EI-


V200R003C00SPC300.cc

End of file

SuccessInfo: Downloading file successfully ended.

You can specify the file name of the loaded system software. If the file name is not specified,
the original name is used.
Step 4 (Optional) Obtain the new configuration file.
If the configuration file is not modified, this step is not required
sftp-client> get vrpcfgnew.zip

Step 5 (Optional) Obtain the new patch file.


If the patch file is not modified, this step is not required
sftp-client> get S5700-v200r002sph001.pat

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 28


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a Single SwitchUpgrade
Upgrade Guide Operations on a Single Switch

Step 6 Close the SFTP connection.


sftp-client> quit

Step 7 Specify the system software in service, which is loaded when the S5700EI is started.
<Quidway> startup system-software S5700EI-V200R003C00SPC300.cc

If the following information is displayed after you run the startup system-software file command, enter
Y to update the BootROM. If the BootROM is upgraded successfully, go to step 9; otherwise, go to step
8.
Warning: Basic BOOTROM will be upgraded. Continue?(Y/N)[N]: y
BOOTROM begin to be upgraded ! please wait for a moment...

Info: BOOTROM upgrade is ok.


Succeeded in setting the software for booting system.

Step 8 (Optional) Upgrade the BootROM in service, which is loaded when the S5700EI is started.
<Quidway> system-view
[Quidway] upgrade basic-bootrom S5700EI-V200R003C00SPC300.cc
upgrade basic-bootrom S5700EI-V200R003C00SPC300.cc
Warning: Basic BOOTROM will be upgraded. Continue? (Y/N): y
Upgrading BOOTROM,please wait for a moment...

[Slot 0]:
Info: BOOTROM upgrade is ok.

In the V100R005 or a later version, the BootROM is upgraded automatically. To upgrade the software to
other versions, you must upgrade the BootROM manually. For details about automatic BootROM
upgrade, see Step 6. In the case of a version rollback, you are advised to manually upgrade the
BootROM to prevent a rollback failure.

Step 9 Restart the S5700EI.

After the software is upgraded to V200R003C00SPC300, you must specify the system software for next
startup. If the system software is not specified or the invalid software is specified, the device will fail to
restart. For details about specifying the system software for next startup, see Step 5.

When the system asks you whether to save the configuration, enter y or n. After the setting is
complete, enter y to restart the system.
<Quidway> reboot
Info: The system is now comparing the configuration, please wait.
Warning: The configuration has been modified, and it will be saved to the next s
tartup saved-configuration file flash:/105_xu.cfg. Continue? [Y/N]:y
Now saving the current configuration to the slot 0....
Save the configuration successfully.
Info: If want to reboot with saving diagnostic information, input 'N' and then e
xecute 'reboot save diagnostic-information'.
System will reboot! Continue?[Y/N]:y
Info: System is rebooting, please wait.

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 29


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a Single SwitchUpgrade
Upgrade Guide Operations on a Single Switch

4.2 Upgrading the Switch to the V200R003C00SPC300


Using the BootROM
If the BootROM method is used, the services will be interrupted for a long time; therefore,
you are advised to upgrade an operating device by using the command line. If the device
cannot enter the command line mode, upgrade the device by using the BootROM.

Figure 1.1 Flowchart for upgrading the version to the V200R003C00SPC300 using the BootROM

Start

Upload system
See 4.2.1
software

Specify startup
See 4.2.2
software

Restart the switch See 4.2.3

End

The methods for upgrading the system software using the BootROM are similar on the S5700, and the
S6700. The S5700EI is used as an example to describe the upgrade procedure. In versions earlier than
V200R001C00SPC100, the default password of the BootROM menu is huawei or www.huawei.com.

4.2.1 Uploading the System Software


Uploading the System Software Through the Serial Interface
Purpose To upgrade the system software

Impact Services are interrupted during the system software uploading and the
device reboot.
Time Required The software uploading time depends on many factors, such as the
system software size, transmission rate on the serial interface, and
operator's skill. When the transmission rate of the serial interface is
115200 bit/s, the uploading time is about 30 minutes.
Prerequisites  The matched BootROM is upgraded.
 The flash memory has enough space to store the system software.

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 30


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a Single SwitchUpgrade
Upgrade Guide Operations on a Single Switch

Step 1 Enter the BootROM menu.


When the S5700EI is starting, the following information is displayed:
Press Ctrl+B to enter BOOTROM menu... 1

Press Ctrl+B before the countdown timer expires, and then enter the password. The default
password is Admin@huawei.com. Then the advanced BootROM menu is displayed. The
following information is displayed:
BOOTROM MENU

1. Boot with default mode


2. Enter serial submenu
3. Enter startup submenu
4. Enter ethernet submenu
5. Enter filesystem submenu
6. Modify BOOTROM password
7. Clear password for console user
8. Reboot

Enter your choice(1-8):

Step 2 Select 2. Enter serial submenu. The following information is displayed:


SERIAL SUBMENU
1. Update BOOTROM system
2. Download file to Flash through serial interface
3. Modify serial interface parameter
4. Return to main menu

Enter your choice(1-4):

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 31


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a Single SwitchUpgrade
Upgrade Guide Operations on a Single Switch

Step 3 Modify the parameters of the serial interface.

Changing the transmission rate of the serial interface causes interruption of the
communication between the PC and S5700EI. To restore the communication between the PC
and the S5700EI, you must set the transmission rate of the serial interface on the PC the same
as that of the serial interface on the S5700EI.
The XMODEM protocol is transmitted at 128 bit/s. If the size of a packet is not a multiple of
128 bits, the packet size increases. After the stack reboots, configurations cannot be restored
because the packet size changes. It is recommended that you download the system software
package through FTP or TFTP.

Select 3. Modify serial interface boot parameter. The following information is displayed:
1: 9600(default)
2: 19200
3: 38400
4: 57600
5: 115200

Select an appropriate baud rate:


Enter your choice(1-5):

Select the transmission rate for the serial interface as required. The transmission rate is
expressed in bit/s. The default transmission rate of the serial interface on the S5700EI is 9600
bit/s. A larger value you enter represents a higher transmission rate of the serial interface. It is
recommended that you enter 5. 115200. If you change the transmission rate of the serial
interface on the S5700EI, set the transmission rate of the serial interface on the PC the same
as that of the serial interface on the S5700EI. In this manner, you can restore the
communication between the PC and the S5700EI.
For example, after you select 5: 115200, the following information is displayed:
Baud rate is 115200 bps. Please change the terminal's speed to 115200 bps

In this case, you need to perform the following settings on the HyperTerminal of the PC to
restore the communication between the PC and the S5700EI:
 On the HyperTerminal, choose Call > Disconnect. The connection is closed
 Choose File > Properties. The Properties dialog box is displayed.
 On the Connect To tab page, click Configure. The COM Properties dialog box is
displayed.
 Select 115200bit/s from the Bits per second drop-down list box.
 In the COM Properties and Properties dialog boxes, click OK.
 On the HyperTerminal, choose Call > Call. The connection is reestablished.
Step 4 Upgrade the system software.
Select 2. Download file to Flash through serial interface in the serial interface submenu,
and the following information is displayed:

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 32


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a Single SwitchUpgrade
Upgrade Guide Operations on a Single Switch

Enter your choice(1-4): 2

Please Select File.


XMODEM downloading ...CC

Choose Transfer > Send File. The Send File dialog box is displayed.
Click Browse to select the upgrade file of the system software. Then select Xmodem from the
Protocol drop-down list box. Click Send to start sending the file.
After transferring the upgrade file, the system prompts you whether to change the file name. If
no, save it with the default file name. The default file name is not the uploaded file name. The
system software name in the flash memory or the default file name hw-switch.cc is used.
Generally, it is recommended that the file name be changed.

Only the files with the file name extension .cc can be used as the upgrade files of the system software on
the S5700EI.

If you need to name the upgrade file S5700EI-V200R003C00SPC300.cc, the following


information is displayed:
Please select file.
XMODEM downloading ...CC Downloading file to SDRAM succeeded.
Warning: Don't Power-off or Reset the Device!!!
Update BootROM system ... done !
S5700EI-V200R003C00SPC300.cc

If the file S5700EI-V200R003C00SPC300.cc has already been saved in the flash memory,
the system prompts you whether to overwrite the existing file with the new one. The
following information is displayed:
flash:/S5700EI-V200R003C00SPC300.cc already exist,
delete it?(Y/N):y
Deleting file.......................................done
took time : 251s
Writing
Flash.............................................................................
..................................................................................
..............done

file length: 14,066,348 bytes, took time : 244s

SERIAL SUBMENU

1. Update BOOTROM system


2. Download file to Flash through serial interface
3. Modify serial interface parameter
4. Return to main menu

Enter your choice(1-4):

After the upgrade file is transferred, select 4. Return to main menu to return to the
BootROM menu.
----End

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 33


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a Single SwitchUpgrade
Upgrade Guide Operations on a Single Switch

Uploading the System Software Through the Network Port


Purpose To upload the system software

Impact Services are interrupted during the system software uploading and the
device reboot.
Time If the system software is uploaded through the FTP or TFTP protocol,
Required the system software uploading time is about one minute.

Prerequisites  The matched BootROM is upgraded.


 The flash memory has enough space to store the system software.
 The FTP service is enabled on the PC.

Pay attention to the following points:


 Select 4. Return to main menu in the BootROM menu to return to the BootROM menu,
and then select 8. Reboot to reboot the BootROM. Enter the BootROM menu and load
the system software. In addition, specify the software to be loaded in the startup.
 Upgrade the system software using the network interface in the BootROM menu.
Step 1 Enter the BootROM menu.
Before entering the BootROM menu, you need to restart the S5700EI. During the restart of
the S5700EI, the following information is displayed:
Press Ctrl+B to enter BOOTROM menu... 1

Press Ctrl+B before the countdown timer expires, and then enter the password. The default
password is Admin@huawei.com. Then the advanced BootROM menu is displayed. The
following information is displayed:
BOOTROM MENU

1. Boot with default mode


2. Enter serial submenu
3. Enter startup submenu
4. Enter ethernet submenu
5. Enter filesystem submenu
6. Modify BOOTROM password
7. Clear password for console user
8. Reboot

Enter your choice(1-8):

Step 2 Select 4. Enter serial submenu. The following information is displayed:


ETHERNET SUBMENU

1. Update BOOTROM system


2. Download file to Flash through ethernet interface
3. Upload Configuration file to Ftp through ethernet interface
4. Modify ethernet interface boot parameter
5. Return to main menu

Be sure to select 4 to modify boot parameter before downloading!

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 34


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a Single SwitchUpgrade
Upgrade Guide Operations on a Single Switch

Enter your choice(1-5):

Step 3 Modify the parameters of the network interface.


Select 4. Modify ethernet interface boot parameter. The following information is
displayed:
BOOTLINE SUBMENU

1. Set TFTP protocol parameters


2. Set FTP protocol parameters
3. Return to ethernet menu

Select TFTP or FTP as required.


For example, the following information is displayed if you select 2. Set FTP protocol
parameters. The displayed information cannot be cleared. New settings will overwrite the
old settings.

If the TFTP protocol is used, you do not need to enter the user name and password.
'.' = clear field; '-' = go to previous field; ^D = quit
Load File name : S5700EI-V200R003C00SPC300.cc
Switch IP address : 192.168.1.15:FFFFFF00
Server IP address : 192.168.1.40
FTP User Name : cx
FTP User Password : cx

The fields are described as follows:


 Load File name: file name of the startup file to be loaded
 Switch IP address: device IP address (the mask is optional)
 Server IP address: server IP address
 FTP User Name: FTP user name
 FTP User Password: FTP password
Step 4 Download the system software.
After network interface parameters are modified, select 3. Return to ethernet menu to return
to the Ethernet submenu. Connect the data line to port 1 on the S5700EI panel (or connect the
data line to the MEth interface of the S6700/S5700), and then select 2. Download file to
Flash through ethernet interface to load the file. The following information is displayed:
'.' = clear field; '-' = go to previous field; ^D = quit

boot device : et
unit number : 0
processor number : 0
host name : host
file name : S5700EI-V200R003C00SPC300.cc
inet on ethernet (e) : 192.168.1.15:FFFFFF00
host inet (h) : 192.168.1.40
user (u) : cx
ftp password (pw) : cx
flags (f) : 0x0

Attached TCP/IP interface to mottsec0.

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 35


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a Single SwitchUpgrade
Upgrade Guide Operations on a Single Switch

Attaching network interface lo0... done.


Loading...
Read file to sdram .......Done
Writing
Flash.............................................................................
..................done
File length: 14,066,348 bytes
Time taken : 90s

After the upgrade file is transferred, select 5. Return to main menu to return to the
BootROM menu.
----End

4.2.2 Specifying the System Software to Be Loaded for Starting


the Switch
Purpose To specify the system software for next startup

Impact Services are interrupted when you are specifying the system software and
the device is restarting.
Prerequisite The system software to be specified has been downloaded to the flash
memory.

Step 5 Specify the system software to be loaded for starting the switch.
After returning to the BootROM menu, select 3. Enter startup submenu to enter the startup
submenu. The following information is displayed:
Startup Configuration Submenu

1. Display startup configuration


2. Modify startup configuration
3. Return to main menu

Enter your choice(1-3):

Step 6 Select 2. Modify startup configuration to set the startup mode of the S5700EI, system
software, configuration file, license file, and patch file. The following information is
displayed:
Note: startup file field cannot be cleared

'.'=clear field; '^D'=quit; Enter=use current configuration

startup type(1: Flash 2: Server)


current: 1
new : 1
Flash startup file (cannot be cleared)
current:
new : S5700EI-V200R003C00SPC300.cc
saved-configuration file
current: vrpcfg.zip

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 36


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a Single SwitchUpgrade
Upgrade Guide Operations on a Single Switch

new :
patch package
current:
new :

Table 1.1 describes the displayed information.

Table 1.1 Description of the displayed information


Field Description

startup type Startup mode:


 1: loads the system software from the flash memory.
 2: loads the system software from the server.
Flash startup file System software loaded during the startup. If the system
software is loaded from the server, you do not need to set the
field.
saved-configuration file Configuration file loaded during startup.
patch package Patch file loaded during startup.
current File that is currently loaded.
new File to be loaded during the next startup.

Startup Configuration Submenu

1. Display startup configuration


2. Modify startup configuration
3. Return to main menu

Enter your choice(1-3):

Step 7 After entering the startup information, select 3. Return to main menu to return to the
BootROM menu.

BOOTROM MENU

1. Boot with default mode


2. Enter serial submenu
3. Enter startup submenu
4. Enter ethernet submenu
5. Enter filesystem submenu
6. Modify BOOTROM password
7. Clear password for console user
8. Reboot
Enter your choice(1-8):

----End

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 37


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a Single SwitchUpgrade
Upgrade Guide Operations on a Single Switch

4.2.3 Restarting the Switch


The switch is automatically upgraded by loading the latest system software during startup.
Enter 8. Reboot on the advanced BootROM menu to restart the switch. Then, the S5700EI
restores the baud rate on the console interface to 9600 bit/s. The baud rate of the
HyperTerminal also needs to be set to 9600 bit/s. The PC then can communicate with the
S5700EI.

4.3 Upgrading the Switch to V200R003C00SPC300 Using


the USB Flash Drive
4.3.1 Overview
If you do not have a PC in the on-site deployment, use the USB flash drive in which the
system software and configuration file are stored. The software commissioning engineer is not
required.

Only the S5700-28X-LI-24S-DC ,S5700-28X-LI-24S-AC, S5700-SI, S5700-HI, S5710EI and S6700


can be upgraded using the USB flash drive. Stacks do not support this upgrade method.

The general process of the upgrade in the USB way is as follows:


1. Copy files.
When the switch is started successfully (the SYS indicator is in green and blinks at 0.5
Hz), the USB flash drive can be inserted to load files. The switch automatically
downloads the system software and configuration file according to the index file in the
USB flash drive.
2. Restart the switch.
The switch sets the system software and configuration file for next startup, and then
restarts automatically.
3. Verify the loading of files.
After restarting successfully (the SYS indicator is in green and blinks at 0.5 Hz), the
switch begins to verify the loaded files. When the SYS indicator is in orange and blinks
at 0.5 Hz, the upgrade is finished.

4.3.2 Upgrading the Software Using the USB Flash Drive


Preparations for Upgrade
Step 1 Prepare the hardware.
 USB port: The S5700-LI and S5700-SI provide USB 1.1; the S5710-EI, S5710HI,S5700-
HI and S6700 provide USB 2.0.

In the S5700LI and series, only the S5700-28X-LI-24S-DC and S5700-28X-LI-24S-AC


models support USB-based deployment.

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 38


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a Single SwitchUpgrade
Upgrade Guide Operations on a Single Switch

 USB flash drive:


The USB flash drive delivered with Huawei switch is recommended because this USB
flash drive is compatible with the switch. The USB flash drive must be paid
independently. If you have not bought the USB flash drive, contact local Huawei office.
The USB flash drive must use the FAT32 format; otherwise, set the format to FAT32
before using it.
The space in the USB flash drive must be sufficient for the system software and
configuration file.
Step 2 Prepare system software, configuration file, web file, and patch file.
Step 3 Create the index file.
1. Create the file usbload_config.txt.
2. Fill in the file.
 When an S5700-SI is upgraded to V200R003C00SPC300, the index file is in either of
the following formats:

If an index file contains the following two formats, the S5700-SI uses the information in format (2). If
the required information is not obtained, the S5700-SI uses the information in format (1).
To write multiple items in the index file, press Enter when you finish each item.

(1) To upgrade the same system software and configuration file on multiple devices, fill in the
file in the format <boardtype=s53mv; vrpfile=; cfgfile=; patchfile=;/>.
− boardtype=s53mv is a fixed format, which does not need to be modified.
− Fill in the system software name behind vrpfile=.
− Fill in the configuration file name behind cfgfile=.
− Fill in the patch file name behind patchfile=.
Example:
<boardtype=s53mv; vrpfile=S5700SI-V200R003C00SPC300.cc; cfgfile=vrpcfg.cfg;
patchfile=patch.pat;/>

(2) To upgrade a single device, fill in the file in the format <mac=; vrpfile=; cfgfile=;
patchfile=;/>.
− View the MAC address of the switch on the chassis and fill in the MAC address
behind mac= in the format XXXX-XXXX-XXXX.
− Fill in the system software name behind vrpfile=.
− Fill in the configuration file name behind cfgfile=.
− Fill in the patch file name behind patchfile=.
Example:
<mac=0018-8200-0001; vrpfile=S5700SI-V200R003C00SPC300.cc;
cfgfile=vrpcfg1.cfg; patchfile=patch1.pat;/>
<mac=0018-8200-0002; vrpfile=S5700SI-V200R003C00SPC300.cc;
cfgfile=vrpcfg2.cfg; patchfile=patch2.pat;/>
 If you need to upgrade the system software, configuration file or patch file of
V200R003C00SPC300, the index file is in any of the following formats:
<time-sn=201301090851;/>
<usb-deployment password=123abc;/>
<mac=; vrpfile=; vrpver=; cfgfile=; webfile=; patchfile=;/>

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 39


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a Single SwitchUpgrade
Upgrade Guide Operations on a Single Switch

<esn=; vrpfile=; vrpver=; cfgfile=; webfile=; patchfile=;/>


<boardtype=; vrpfile=; vrpver=; cfgfile=; webfile=; patchfile=;/>

 The first line in the index file must be the SN to prevent repeated copy. The SN consists of creation
date + time, for example, <time-sn=201105091219;/>. Before copying a file, the device compares
the SNs. If the SN of a file to be copied already exists, the device does not copy the file. After the
file is copied, the device stores the SN. The index files without SNs are considered invalid, and the
device will stop copying the files.
 If an index file contains the following three formats, the device uses the information in format (2). If
the required information is not obtained, the device uses the information in format (3) and then
format (1). When only one USB flash drive is used in the upgrade, the values of mac=, esn=, and
boardtype= are default. When the device obtains the value default, the device starts to copy the file
without comparing it with other files.
 When editing an index file, press Enter when a line is finished. After editing the file, save it.
 Select the upgrade files, including system software, configuration file, Web file, and patch file as
required.
 The upgrade procedures for S5700-LI, S5710-HI ,S5700-SI, S5700-HI , S5710EI and S6700 are the
same.

(1) To upgrade the same system software, configuration file, Web file, and patch file on
multiple devices, fill in the file in the format <boardtype=; vrpfile=; vrpver=; cfgfile=;
webfile=; patchfile=;/>.
− To obtain the value of boardtype, view device labels or run the display version
command. boardtype=default indicates that all devices will be upgraded.
− Fill in the system software name behind vrpfile=.
− Fill in the version number behind vrpfile=.
− Fill in the configuration file name behind cfgfile=.
− Fill in the web file name behind webfile=.
− Fill in the patch file name behind patchfile=.
The following are the index files of different devices:
<boardtype=S5700-HI; vrpfile=S5700HI-V200R003C00SPC300.cc;
vrpver=V200R003C00SPC300; cfgfile=; webfile=; patchfile=;/>
<boardtype=S6700-EI; vrpfile=S6700EI-V200R003C00SPC300.cc;
vrpver=V200R003C00SPC300; cfgfile=; webfile=; patchfile=;/>

The following two formats are used for upgrading a single device:
(2) <mac=; vrpfile=; vrpver=; cfgfile=; webfile=; patchfile=;/>
− View the device's MAC address on the chassis and fill in the MAC address behind
mac= in the format XXXX-XXXX-XXXX.
− Fill in the system software name behind vrpfile=.
− Fill in the version number behind vrpfile=.
− Fill in the configuration file name behind cfgfile=.
− Fill in the web file name behind webfile=.
− Fill in the patch file name behind patchfile=.
The following is an example of configuration file:
<mac=0018-8200-0001; vrpfile=; vrpver=; cfgfile=vrpcfg.cfg; webfile=;
patchfile=;/>

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 40


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a Single SwitchUpgrade
Upgrade Guide Operations on a Single Switch

The following is an example of patch file:


<mac=0018-8200-0002; vrpfile=; vrpver=; cfgfile=; webfile=; patchfile=patch.pat;/>

(3) <esn=; vrpfile=; vrpver=; cfgfile=; webfile=; patchfile=;/>


− View the device's ESN and fill in the ESN behind esn=.
− Fill in the system software name behind vrpfile=.
− Fill in the version number behind vrpfile=.
− Fill in the configuration file name behind cfgfile=.
− Fill in the web file name behind webfile=.
− Fill in the patch file name behind patchfile=.
The following is an example of patch file:
<esn=2102353169107C800132; vrpfile=; vrpver=; cfgfile=; webfile=;
patchfile=patch.pat;/>

The following is an example of system software:


<esn=2102353169107C800132; vrpfile=S5700HI-V200R003C00SPC300.cc;
vrpver=V200R003C00SPC300; cfgfile=vrpcfg.cfg; webfile=; patchfile=;/>

If a keyword is not found or matched, the value of this item is considered to be empty.

If the version number behind vrpver= is the same as the current version, the device will not
restart.
Step 4 Copy the index file, system software, configuration file, Web file, and patch file to the root
directory of the USB flash drive.

The index files must be stored to the root directory on the USB flash drive; the other files are stored in
the corresponding directories.

 Do not power off the switch during file copy; otherwise, the upgrade fails or the switch
cannot start.
 Do not remove the USB flash drive before the upgrade is finished; otherwise, the USB
flash drive may be damaged.

----End

Procedure
Step 1 Power on the S5700-HI, and wait until the system completes the startup (you are advertised to
wait for two minutes).
Step 2 Confirm that the system is operating stably (the SYS indicator is in green and blinks every
two seconds). If the system operating is unstable, wait or solve the issue.

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 41


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a Single SwitchUpgrade
Upgrade Guide Operations on a Single Switch

 If the SYS indicator is on and in green or orange, the system startup is not finished. Wait
until the system starts successfully.
 If the SYS indicator is steady on and blinks red, the system is started but an error occurs.
Fix the problem before the next step. Check whether the power supply and the fan
function properly. If no, power off the S5700-HI, and then restart the S5700-HI. If the
fault persists (the indicator is on and in red), contact Huawei technical support personnel.
Step 3 Insert the USB flash drive.
 If the SYS indicator is in green and blinks more than twice every second, the system is
copying the system software and configuration file from the USB flash drive.
 After copying the files, the system restarts.
 If the SYS indicator is in orange and blinks every two seconds after the restart, the
upgrade is successful. Now you can remove the USB flash drive.
If the SYS indicator is steady on or blinks red, an error occurs. Power off the S5700-HI and
power on it, and then insert the USB flash drive again. If the upgrade fails three times, check
whether the index file on the USB flash drive is correct, or contact the Huawei technical
support personnel.

When using the USB flash drive for upgrade, change the SN in the USB flash drive.

If you want to upgrade the software through USB flash drive upon a failure of USB-based upgrade, load
the files to the USB flash drive again.

----End

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 42


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a StackUpgrade Operations
Upgrade Guide on a Stack

5 Upgrade Operations on a Stack

5.1 Upgrading All Stack Member Switches to


V200R003C00SPC300 by Using the Command Line
Purpose To upgrade the system software

Impact Services are interrupted when the devices restart.

Time When a single device is upgraded and service deployment is simple,


Required services are interrupted about 3 minutes. When a stack is upgraded, the
service interruption time increases, and the time depends on the
complexity of services and the stack.
Prerequisites  The devices to be upgraded function properly.
 The flash memory has enough space to store the system software.

 The methods of for upgrading the system software of the S2750, S5700, and the S6700 using the
command line interface are similar. The section describes only how to download the system software
by using the S5700 as the FTP server. For other methods of loading the system software, see the
S2750&S5700&S6700 Series Ethernet Switches Configuration Guide - Basic Configurations.
 The S5700&S6700 provides a management interface MEth. You can use this interface as a Layer 3
interface.
 To retain the roles of the master and slave devices after the upgrade, set priority of the master switch
to be the highest in the stack before the upgrade.

The following operations are performed on the master switch. Here, the stack contains two
member switches.
Step 4 Ensure that all the member switches have sufficient available space in the flash memory. For
details, see section 3.7"Checking the Flash Memory Space."
Step 5 Configure the switch as the FTP server.
Start the FTP service on the switch, and set the FTP user name to ftpuser and password to
admin@123456.
<Quidway> system-view

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 43


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a StackUpgrade Operations
Upgrade Guide on a Stack

[Quidway] ftp server enable


[Quidway] aaa
[Quidway-aaa] local-user ftpuser password cipher admin@123456
[Quidway-aaa] local-user ftpuser service-type ftp
[Quidway-aaa] local-user ftpuser ftp-directory flash:
[Quidway-aaa] return

Step 6 Configure an IP address for the switch.


Configure the IP address on an idle interface. Here, GigabitEthernet 0/0/1 is used as an
example.
<Quidway> system-view
[Quidway]interface GigabitEthernet 0/0/1
[Quidway-GigabitEthernet0/0/1]port link-type access
[Quidway-GigabitEthernet0/0/1]quit
[Quidway] vlan 10
[Quidway-vlan10] port GigabitEthernet 0/0/1
[Quidway-vlan10] quit
[Quidway] interface vlanif 10
[Quidway-Vlanif10] ip address 1.1.1.1 24
[Quidway-Vlanif10] quit
[Quidway]

Step 7 Log in to the FTP server (the switch).

Assume that the Windows XP operating system is used.

Store the file to be uploaded in the specified directory (for example, D:\>directory). Choose
Start > Run. Enter cmd and press Enter. Enter FTP 1.1.1.1. Enter the user name at the user
prompt and the password at the password prompt, and then press Enter. The following
information is displayed:
D:\>ftp 1.1.1.1
Connected to 1.1.1.1.
220 FTP service ready.
User (1.1.1.2:(none)): ftpuser
331 Password required for 1.
Password:
230 User logged in.
ftp>

Step 8 Back up the current system software.


Copy the current system software to the specified directory, for example, D:\>. The following
information is displayed:
ftp> get S5700EI-V200R002C00SPC100.cc D:\S5700EI-V200R002C00SPC100.cc
200 Port command okay.
150 Opening ASCII mode data connection for directory list.
226 Transfer complete.
ftp: 14,066,348 bytes sent in 60.40Seconds 140.76Kbytes/sec.
14,066,348 bytes sent in 60.40Seconds 140.76Kbytes/sec
ftp>

Step 9 Upload the system software to the switch.

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 44


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a StackUpgrade Operations
Upgrade Guide on a Stack

Run the put source-filename [ destination-filename ] command on the FTP client to upload
the system software. After system software is uploaded to the switch, run the bye command to
close the FTP connection and return to the user view.
ftp> put D:\S5700EI-V200R003C00SPC300.cc
200 Port command okay.
150 Opening BINARY mode data connection for S5700EI-V200R003C00SPC300.cc.
226 Transfer complete.
ftp: 14,066,348 bytes sent in 80.40Seconds 140.76Kbytes/sec.
ftp> bye
221 Server closing.

D:\>

Step 10 Specify the uploaded software as the next startup software.


<Quidway> startup system-software S5700EI-V200R003C00SPC300.cc all

If the following information is displayed after you run the startup system-software file command, enter
y to upgrade the BootROM.
Warning: Basic BOOTROM will be upgraded. Continue?(Y/N)[N]: y
BOOTROM begin to be upgraded ! please wait for a moment

Info: BOOTROM upgrade is ok.


Info: Succeeded in setting the software for booting system on 0.
100% complete\
Info: Copied file flash:/S5300EI-V200R003C00SPC300.cc to slot1#flash:/ S5300EI-
V200R003C00SPC300.cc...Done.
Info: Succeeded in setting the software for booting system on 0.
The file flash:/ S5300EI-V200R003C00SPC300.cc already exists in the board 1.
Overwrite? [Y/N]:n.
Info: Succeeded in setting the software for booting system on 1

Step 11 Restart the switch.

After the software is upgraded to V200R003C00SPC300, you must specify the system software for next
startup. If the system software is not specified or the invalid software is specified, the device will fail to
restart. For details about specifying the system software for next startup, see Step 5.

When the system asks you whether to save the configuration, enter y or n. After the setting is
complete, enter y to restart the system.
<Quidway> reboot
Info: The system is now comparing the configuration, please wait.
Warning: The configuration has been modified, and it will be saved to the next s
tartup saved-configuration file flash:/105_xu.cfg. Continue? [Y/N]:y
Now saving the current configuration to the slot 0....
Save the configuration successfully.
Info: If want to reboot with saving diagnostic information, input 'N' and then e
xecute 'reboot save diagnostic-information'.
System will reboot! Continue?[Y/N]:y
Info: System is rebooting, please wait.

----End

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 45


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a StackUpgrade Operations
Upgrade Guide on a Stack

5.2 Using the Intelligent Upgrade Function


5.2.1 Overview
Intelligent upgrade is a function that automatically upgrades or rolls back the system software
of a new member switch to the version of the master switch.
A stack system is established only when all the following requirements are met:
 All the member switches use the same software version. If the master switch detects a
different software version on the new member switch, it upgrades or rolls back the
software of the new member switch to the version of the stack.

The S2750,S5700 and the S6700 support up to nine switches in a stack system.
 All the member switches belong to the same series. That is, the EI series and SI series
cannot form a stack.
 All the member switches are connected by using stack cables and stack modules.
 All the member switches are working properly.
 The stacking function is enabled on all the member switches.
The stack processes version upgrade and rollback for new member switches in the same way.

5.2.2 Upgrading a New Member Switch Using the Intelligent


Upgrade Function
Preparations for Upgrade
Before upgrading a new member switch of a stack, ensure that:
 The new member switch and the current stack members belong to the same series.
 The new member switch is connected to other member switches by using stack cables
and stack modules.
 The stacking function is enabled on the new member switch. (This function is enabled by
default.)

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 46


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a StackUpgrade Operations
Upgrade Guide on a Stack

 If the flash memory of the new member switch does not have sufficient space to store the
startup software package, the switch automatically deletes a software package to free up
the space. If the switch is an S5700, it deletes a non-startup software package. If the
available space in the flash memory is still insufficient for the upgrade software, the switch
restarts repeatedly. In this case, upgrade the software of the switch to the version of the
stack system manually, and then add the switch to the stack. For the upgrade procedure,
see chapter 4Upgrade Operations on a Single Switch.
 During the upgrade, ensure that the stack cables are functioning properly. If the upgrade of
a switch fails, upgrade the system software of the switch to the version of the stack
manually, and then add the switch to the stack.
 The running time of the newly added stack must be shorter than the running time of the
old stack; otherwise, the new stack software cannot be upgraded to the same version as the
old stack software through intelligent upgrade.

Upgrade Process
Start the new member switch.
The master switch of the stack automatically upgrades the new switch. If the upgrade is
successful, the following information will be displayed:
On the master switch:
In Stack, device 0 load to new device 1 .......... start

In Stack, device 0 load to new device 1 .......... success

On the new member switch:


The Software Version is Low.Version is V200R003C00SPC300!
100% completed
In Stack, device 0 load flash:/S5700EI-V200R003C00SPC300.cc to new device
1(self) ... Success
Starting upgrade BOOTROM .............. Pass

Device starting reset.

If the flash memory of the new member switch does not have sufficient space for the upgrade
software, the following information is displayed:
On the master switch:
In Stack, device 0 load to new device 1 .......... start

In Stack, device 0 load to new device 1 .......... fail

On the new member switch:


In Stack, upgrading from slot 4 to slot 0(self) .......... start
Info: Free space is not enough. Auto deleting <flash:/S5700EI-
V200R003C00SPC300.cc> file ....
................................................................................
........................... success

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 47


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches Upgrade Operations on a StackUpgrade Operations
Upgrade Guide on a Stack

100% completed
In Stack, device 4 load to new device 0 (self) ... Success
Upgrading BOOTROM .............. Pass

Manually upgrade the system software of the switch to the version of the stack system, and
then add the switch to the stack system. For details, see sections 4.1Upgrading the Switch to
V200R003C00SPC300 Using the Command Line or 4.2Upgrading the Switch to the
V200R003C00SPC300 Using the BootROM.

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 48


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches
Upgrade Guide Verifying the UpgradeVerifying the Upgrade

6 Verifying the Upgrade

6.1 Verification Checklist


Table 1.1 Verification checklist
No. Item Criteria Result

1 Check the current system The system software version


software version is V200R003C00SPC300.
2 Check the device running The device runs properly.
status
3 Check the system The system configuration is
configuration correct.

6.2 Checking the Current System Software Version


Run the display version command to view the version of the system software running on the
S5700EI.
<Quidway> display version
Huawei Versatile Routing Platform Software
VRP (R) software, Version 5.120 (S5700 V200R003C00SPC300)
Copyright (C) 2000-2012 HUAWEI TECH CO., LTD
Quidway S5752C-EI Routing Switch uptime is 0 week, 0 day, 0 hour, 4 minutes

EDFE 0(Master) : uptime is 0 week, 0 day, 0 hour, 4 minutes


64M bytes DDR Memory
16M bytes FLASH
Pcb Version : VER C
Basic BOOTROM Version : 124 Compiled at Apr 20 2011, 10:04:52
Software Version : VRP (R) Software, Version 5.120 (V200R003C00SPC300)

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 49


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches
Upgrade Guide Verifying the UpgradeVerifying the Upgrade

6.3 Checking the Device Running Status


Run the display device command to check the switch running status. Normal indicates that
the device functions properly.
<Quidway> display device
S5752C-EI's Device status:
Slot Sub Type Online Power Register Status Role
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0 - 5752C Present PowerOn Registered Normal Master
3 FAN Present PowerOn Registered Normal NA
4 POWER Present PowerOn Registered Normal NA

6.4 Checking the System Configuration


Use the display current-configuration command to check the system configuration. Check
whether the system software version is V200R003C00SPC300 (V200R003C00SPC300 is
taken as an example and the actual version number depends on the released version) and
whether the configuration is restored (the following configuration is taken as an example).
The configuration file may be modified after the upgrade. For the command line changes, see
the release notes of the matching version.
<Quidway>display current-configuration
!Software Version V200R003C00SPC300
#
sysname Quidway
#
dhcp enable
#
undo http server enable
undo http secure-server enable
#
user-interface vty 16 20
#
undo nap slave enable
#
aaa
authentication-scheme default
authorization-scheme default
accounting-scheme default
domain default
domain default_admin
local-user admin password cipher admin
local-user admin service-type http
#

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 50


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches
Upgrade Guide Version RollbackVersion Rollback

7 Version Rollback

7.1 S2750&S5700&S6700 Version Rollback


7.1.1 Version Rollback Flowchart
Figure 1.2 Version rollback flowchart

Start

Load previous
See 7.1.2
software package

Perform version rollback See 7.1.3

Verify version rollback See 7.1.4

End

1. Only the configuration file in cfg format can be used for rollback. Before performing
version rollback, check the format of the configuration file. If the configuration file is not in
cfg format, save it in the cfg format.

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 51


Copyright © Huawei Technologies Co.,
Ltd
S2750&S5700&S6700 Series Ethernet Switches
Upgrade Guide Version RollbackVersion Rollback

2. If you run the delete command to delete files stored in the flash memory before the device
is rolled back from V200R003C00SPC300 to V100R005, some space in the flash memory
may be unavailable. Run the dir command to view the unknown space and run the fixdisk
command to reclaim the space.
3. If the configuration is not saved after the switch is upgraded to V200R003C00SPC300, the
system version can roll back directly. If the configuration is saved after the upgrade, the
switch faces risks of login failure or service interruption after the system version rolls back to
the old version. To prevent the risks, back up the configuration file before the upgrade.
Rename the configuration file and save it to the flash memory. During version rollback,
specify the old configuration file for the next startup

7.1.2 Loading the Previous System Software


The procedure for loading the previous system software package is the same as the procedure
for loading the system software for the upgrade. For details, see chapters 4Upgrade
Operations on a Single Switch or 5Upgrade Operations on a Stack.

7.1.3 Performing Version Rollback


The version rollback method is the same as the version upgrade method. For details, see
chapters 4Upgrade Operations on a Single Switch or 5Upgrade Operations on a Stack.

7.1.4 Verifying Version Rollback


The verification of version rollback is the same as the verification of version upgrade. For
details, see chapter 6Verifying the Upgrade.

Issue 03 (2013-12-30) Huawei Proprietary and Confidential 52


Copyright © Huawei Technologies Co.,
Ltd

Вам также может понравиться