VIESMANN VITOCELL-W

DHW cylinders for wall mounted boilers


80 to 300 litre capacity

Datasheet
Part numbers and prices: see pricelist
Vitotec folder, register 5 and 7
File in:

VITOCELL 100-W
DHW cylinders
made from steel with Ceraprotect enamel coating
type CWG
wall mounted, 80 litre capacity
type CUG
below, 120 and 150 litre capacity
type CVA
adjacent, 160, 200 and 300 litre capacity
type CVB
adjacent, 300 and 400 litre capacity
(dual-mode, for solar heating systems)

VITOCELL 300-W
DHW cylinders
made from stainless steel
type EVA
adjacent, 160 and 200 litre capacity

5822 307-3 GB 4/2007


Product information Vitocell 100-W

Economical to purchase – reliable in function. The attractively


priced Vitocell 100-W is available in a matching colour – either as
a wall mounted unit or for installation alongside or below the boil-
er.

Vitocell 100-W: Benefits at a glance


& Corrosion-resistant cylinder made from steel with Ceraprotect
enamel coating. Additional cathodic protection via a magnesium
anode; impressed current anode available as an accessory.
& Heating up the total water content through indirect coils stretch-
ing right to the cylinder floor.
& High DHW convenience through rapid, even heat-up via gener-
ously sized indirect coils.
& Low heat losses through highly effective all-round CFC-free
thermal insulation.
& Vitocell 100-W, type CWG, wall mounted.
& Vitocell 100, type CUG, installed below the boiler, with casing
for connecting pipes (accessories).
& Vitocell 100-W, type CVA, freestanding.
& Vitocell 100-W, type CVB, freestanding for dual-mode opera-
tion.

Vitocell 100-W, below the boiler, type CUG


Wall mounted gas fired boiler with wall mounted 80 litre cylin-
der (Vitocell 100-W, type CWG) A Inspection and cleaning aperture
B Highly effective all-round CFC-free thermal insulation
C Indirect coil
D Corrosion-resistant cylinder made from steel with Ceraprotect
enamel coating
5822 307-3 GB

2 VIESMANN VITOCELL-W
Product information Vitocell 300-W

The DHW cylinder for higher demands – made from high-alloyed


stainless steel. The Vitocell 300-W, type EVA, combined with our
wall mounted boilers, offers the highest DHW convenience – both
in terms of economy and hygiene.

Vitocell 300-W: Benefits at a glance


& Long service life through corrosion-resistant DHW cylinder
made from high-grade stainless steel.
& Hygienic and made to food hygiene standard through high sur-
face quality.
& No protective anode required for additional corrosion protection,
therefore no additional running costs.
& Indirect coils right to the cylinder floor heat the entire water con-
tent.
& High DHW convenience through rapid, even heat-up via gener-
ously sized heating surface.
& Low heat losses through highly effective all-round CFC-free
thermal insulation.

Vitocell 300-W, alongside the boiler, type EVA

A Inspection and cleaning aperture


B Total thermal insulation (CFC free)
C Heating surface made from stainless steel
D Stainless steel DHW cylinder
5822 307-3 GB

VITOCELL-W VIESMANN 3
Specification Vitocell 100-W (type CWG)

Specification
& Wall mounted
& Made from steel, with Ceraprotect enamel coating and internal
indirect coils
& Installation either on the l.h. or r.h. side adjacent to the wall
mounted boiler

Contents l 80
DIN register no. 0244/06-13 MC
Connections* 1
Heating water flow and return R 1"
Hot and cold water R ¾"
Permissible operating pressure
Heating water and DHW side bar 10
Permiss. temperatures
– heating water side °C 110
– DHW side °C 95
Standby heat loss * 2 kWh/ 1.37
q BS at 45 K temp. differential 24 h
Dimensions
Length mm 473
Width mm 500
Total width a
– with a Vitodens 200-W and a Vitodens 300-W mm 950
(13 and 19 kW)
– with a Vitopend 200-W and a Vitodens 300-W mm 980
(26 and 35 kW)
Height mm 850
Weight kg 68

DHW output at rated boiler output


Rated output of the wall mounted boiler for kW 16 18 19 22 24 25 32
DHW heating
Continuous DHW output * 3 kW 16 18 19 22 24 24 24
for DHW heating from 10 to 45 °C and an aver- l/h 390 440 465 540 590 590 590
age boiler water temperature of 78 °C
Drawable mixing water volume 45 °C
for heating the DHW cylinder to 60 °C
– without reheating l 89 89 89 89 89 89 89
– with reheating l 119 119 119 119 119 119 119

Note
Pressure drop on the DHW side, see page 15. 5822 307-3 GB

*1
An existing DHW circulation line may be connected to the cold water connection (KW) of the DHW cylinder. For this, install non-return
valves into the cold water supply line and into the DHW circulation line.
*2
Actual value to DIN 4753-8.
*3
The performance factor NLand the peak output are irrelevant here due to the low cylinder capacity

4 VIESMANN VITOCELL-W
Specification Vitocell 100-W (type CWG) (cont.)

Positioning

HR Heating return TH Sensor well for cylinder temperature sensor


HV Heating flow WW DHW
KW Cold water

Dimension a
– with a Vitodens 200-W and a Vitodens 300- mm 950
W (13 and 19 kW)
– with a Vitopend 200-W and a Vitodens 300- mm 980
W (26 and 35 kW)

Delivered condition
Vitocell 100-W, type CWG 80 litre capacity The colour of the epoxy-coated sheet steel casing is white.
DHW cylinder made from steel with Ceraprotect enamel coating.
& Fitted thermal insulation made from rigid PU foam

& Protective magnesium anode

& Welded sensor well for cylinder temperature sensor


5822 307-3 GB

VITOCELL-W VIESMANN 5
Specification Vitocell 100-W (type CUG)

Specification
& Below the boiler
& Made from steel, with Ceraprotect enamel coating and internal
indirect coils

Contents l 120 150


DIN register no. 0245/06-13 MC
with casing to cover with casing to
the interconnecting cover the intercon-
pipes necting pipes
Connections
Heating water flow and return R 1" 1" 1" 1"
Hot and cold water R ¾" ¾" ¾" ¾"
DHW circulation R ¾" ¾" ¾" ¾"
Permissible operating pressure
Heating and DHW side bar 10 10 10 10
Permiss. temperatures
– heating water side °C 110 110 110 110
– DHW side °C 95 95 95 95
Standby heat loss * 1 kWh/24 h 1.60 1.60 1.75 1.75
q BS at 45 K temp. differential
Dimensions
Length a mm 618 * 2 623 661 * 2 667
Width k mm 7 553 564 7 596 607
Height b mm 904 1055 932 1055
Total height mm 1925 +15/-0 1925 +15/-0 1925 +15/-0 1925 +15/-0
Weight kg 72 75 85 88

DHW output at rated boiler output


Rated output of the wall kW 16 18 19 22 24 25 32
mounted boiler for DHW
heating
Continuous DHW output kW 16 18 19 22 24 24 24
for DHW heating from 10 to l/h 390 440 465 540 590 590 590
45 °C and an average boiler
water temperature of 78 °C
Performance factor N L
to DIN 4708
Capacity 120 l 1.2 1.2 1.2 1.2 1.2 1.2 1.2
150 l 1.6 1.6 1.6 1.6 1.6 1.6 1.6
Peak output
over a 10 minute period
Capacity 120 l l/10 min 153 153 153 153 153 153 153
150 l l/10 min 173 173 173 173 173 173 173

Note
Pressure drop on the DHW side, see page 15.
5822 307-3 GB

*1
Standard parameter to DIN V 18599.
*2
Including distance from the wall. Compulsory in conjunction with safety assemblies used with pressure reducers. Otherwise, recom-
mendation only.

6 VIESMANN VITOCELL-W
Specification Vitocell 100-W (type CUG) (cont.)

Positioning

A Top view HV Heating flow


B Top view with casing to cover interconnecting pipes KW Cold water
C Height with casing for interconnecting pipes WW DHW
E Drain TH Sensor well for cylinder temperature sensor
HR Heating return Z DHW circulation

Vitodens 200-W/300-W Vitoladens 300-W


Dimensions Dimensions
l mm 2079 l mm 2186
m mm 2149 m mm 2255

Vitopend 200-W
Dimensions Open flue operation Balanced
flue opera-
tion
10.5-18 kW 10.5-24 kW
l mm 2151 2187 2011
m mm 2206 2252 2068

Dimensions
Contents 120 l 150 l
with casing to cover the with casing to cover
interconnecting pipes the interconnecting
pipes
a mm 618 623 661 667
b mm 904 1055 932 1055
c mm 875 875 902 902
d mm 122 128 144 150
e mm 143 149 165 171
f mm 214 220 235 241
g mm 339 345 360 366
h mm 430 436 452 458
7 553 7 596
5822 307-3 GB

k mm 564 607
n mm 126 191 148 213
o mm 183 248 205 270
p mm 276 341 298 363

VITOCELL-W VIESMANN 7
Specification Vitocell 100-W (type CUG) (cont.)

Delivered condition
Vitocell 100-W, type CUG 120 and 150 litre capacity & Welded sensor well for cylinder temperature sensor
DHW cylinder made from steel with Ceraprotect enamel coating. & Threaded adjustable feet
& Fitted thermal insulation made from rigid PU foam The colour of the epoxy-coated sheet steel casing is white.
& Protective magnesium anode

Specification Vitocell 100-W (type CVA )

Specification
& Adjacent
& Made from steel, with Ceraprotect enamel coating and internal
indirect coils
(for further technical details, see the separate datasheet for the Vitocell 100-V)

Contents l 160 200 300


DIN register no. 0241/06-13 MC/E
Connections
Heating water flow and return R 1" 1" 1"
Hot and cold water R ¾" ¾" 1"
DHW circulation R ¾" ¾" 1"
Permissible operating pressure
– heating water side bar 25 25 25
– DHW side bar 10 10 10
Permiss. temperatures
– heating water side °C 160 160 160
– DHW side °C 95 95 95
Standby heat loss * 1 kWh/24 h 1.50 1.70 2.20
q BS at 45 K temp. differential
Dimensions
Length c (7) mm 581 581 633
Width a mm 605 605 705
Height k mm 1189 1409 1746
Weight kg 86 97 151

DHW output at rated boiler output


Rated output of the wall kW 16 18 19 22 24 25 32 45 60
mounted boiler for DHW heat-
ing
Continuous DHW output
for DHW heating from 10 to 45 °
C and an average boiler water
temperature of 78 °C
Capacity 160 & 200 l kW 15 18 19 22 24 25 26 26 26
l/h 390 440 465 540 590 614 638 638 638
300 l kW 16 18 19 22 24 25 32 44 44
l/h 390 440 465 540 590 614 786 1081 1081
Performance factor N L
to DIN 4708
Capacity 160 l 1.6 2.0 2.0 2.2 2.2 2.2 2.2 2.4 2.4
200 l 2.6 3.0 3.0 3.2 3.2 3.2 3.2 3.7 3.7
300 l 7.5 7.5 7.5 8.0 8.0 8.0 8.0 9.3 9.3
Peak output
during a 10 minute period with
Capacity 160 l l/10 min 173 190 190 199 199 199 199 207 207
200 l l/10 min 214 230 230 236 236 236 236 252 252
300 l l/10 min 357 357 357 368 368 368 368 399 399

Note
Pressure drop on the DHW side, see page 15.
5822 307-3 GB

*1
Actual values to DIN 4753-8.

8 VIESMANN VITOCELL-W
Specification Vitocell 100-W (type CVA ) (cont.)

Positioning

A Inspection and cleaning aperture only for 300 litre capacity. TH Sensor well for cylinder temperature sensor or control ther-
E Drain mostat (at the same height as connector HV)
HR Heating return WW DHW
HV Heating flow Z DHW circulation
KW Cold water

Dimensions
Capacity l 160 200 300
a mm 605 605 705
b mm 317 317 343
c mm 7 581 7 581 7 633
d mm 72 72 76
e mm 249 249 260
f mm 634 634 875
g mm 884 884 1115
h mm 1050 1270 1600
k mm 1189 1409 1746

Delivered condition
Vitocell 100-W, type CVA, 160 to 300 litre capacity & Integral welded sensor well for cylinder temperature sensor or
DHW cylinder made from steel with Ceraprotect enamel coating. control thermostat
& Fitted thermal insulation made from rigid PU foam & Threaded adjustable feet

& Protective magnesium anode The colour of the epoxy-coated sheet steel casing is white.
5822 307-3 GB

VITOCELL-W VIESMANN 9
Specification Vitocell 300-W (type EVA)

Specification
& Adjacent
& Made from stainless steel, with external indirect coils
(for further technical details, see the separate datasheet for the Vitocell 300-V)

Contents l 160 200


DIN register no. 0166/04-10 MC
Connections
Heating water flow and return R 1" 1"
Hot and cold water R ¾" ¾"
DHW circulation R ½" ½"
Permissible operating pressure
– heating water side bar 3 3
– DHW side bar 10 10
Permiss. temperatures
– heating water side °C 110 110
– DHW side °C 95 95
Standby heat loss * 1 kWh/24 h 1.40 1.60
q BS at 45 K temp. differential
Dimensions
Length (7) mm 633 633
Width mm 667 667
Height d mm 1203 1423
Weight kg 84 98

DHW output at rated boiler output


Rated output of the wall kW 16 18 19 22 24 25 32 45 60
mounted boiler for DHW
heating
Continuous DHW output
for DHW heating from 10 to
45 °C and an average boiler
water temperature of 70 °C
Capacity 160 l kW 16 18 19 22 24 24 24 24 24
l/h 390 440 465 540 590 590 590 590 590
200 l kW 16 18 19 22 24 25 32 38 38
l/h 390 440 465 540 590 614 786 933 933
Performance factor N L
to DIN 4708
Capacity 160 l 1.6 1.7 1.7 1.7 1.7 1.7 1.7 2.0 2.0
200 l 2.8 2.9 2.9 2.9 2.9 2.9 2.9 3.2 3.2
Peak output
during a 10 minute period with
Capacity 160 l l/10 min 173 177 177 177 177 177 177 190 190
200 l l/10 min 222 226 226 226 226 226 226 236 236

Note
Pressure drop on the DHW side, see page 16.
5822 307-3 GB

*1
Actual values to DIN 4753-8.

10 VIESMANN VITOCELL-W
Specification Vitocell 300-W (type EVA) (cont.)

Positioning

E Drain KW Cold water


HR Heating return WW DHW
HV Heating flow Z DHW circulation

Dimensions
Capacity l 160 200
a mm 877 1097
b mm 984 1204
c mm 1067 1287
d mm 1203 1423

Delivered condition
Vitocell 300-W, type EVA, with external indirect coils, 160 and & Integral thermometer
200 litre capacity & Threaded adjustable feet
DHW cylinders, on the DHW side made from stainless steel. The colour of the epoxy-coated sheet steel casing is white.
& Fitted thermal insulation made from rigid PU foam

& Integral welded sensor well for cylinder temperature sensor or

control thermostat

Specification Vitocell 100-W (type CVB)

Specification
& Adjacent
& Made from steel, with Ceraprotect enamel coating and internal
indirect coils
& For dual-mode DHW heating
5822 307-3 GB

VITOCELL-W VIESMANN 11
Specification Vitocell 100-W (type CVB) (cont.)

(for further technical details, see the separate datasheet for the Vitocell 100-B)

Contents l 300 400


DIN register no. 0242/06-13 MC/E
Connections
Heating water flow and R 1" 1"
return
Hot and cold water R 1" 1¼"
DHW circulation R 1" 1"
Permissible operating
pressure
heating, brine and DHW
side bar 10 10
Permiss. temperatures
– heating water side °C 160 160
– brine side °C 160 160
– DHW side °C 95 95
Standby heat loss * 1 kWh/ 1.00 1.08
q BS at 45 K temp. differ- 24 h
ential
Dimensions
Length c (7) mm 633 850
Width a mm 705 918
Height m mm 1746 1630
Weight kg 160 167

DHW output at rated boiler output


Rated output of the wall mounted kW 16 18 19 22 24 25 32 45 60
boiler for DHW heating
Continuous DHW output kW 16 18 19 22 24 25 26 26 26
for DHW heating from 10 to 45 °C l/h 390 440 465 540 590 614 638 638 638
and an average boiler water tem-
perature of 78 °C
Performance factor N L* 2 1.3 1.4 1.4 1.4 1.4 1.4 1.4 1.5 1.5
to DIN 4708
Peak output l/10 min 159 164 164 164 164 164 164 168 168
over a 10 minute period

Note
Pressure drop on the DHW side, see page 16.

5822 307-3 GB

*1
Standard characteristics
*2
Values for the upper indirect coils.

12 VIESMANN VITOCELL-W
Specification Vitocell 100-W (type CVB) (cont.)

Positioning

E Drain THo Sensor well for cylinder temperature sensor or control ther-
ELH Connections for electric immersion heater mostat at HVo level
HRo Boiler heating water return THu Sensor well for lower
HRu Solar heating water return thermometer sensor (thermometers are accessories) at HVu
HVo Boiler heating water flow level
HVu Solar heating water flow WW DHW
KW Cold water Z DHW circulation

Dimensions
Capacity l 300 400
a mm 705 918
b mm 343 455
c mm 633 850
d mm 76 107
e mm 260 349
f mm 875 804
g mm 995 924
h mm 1115 1044
k mm 1355 1204
l mm 1600 1458
m mm 1746 1630
5822 307-3 GB

VITOCELL-W VIESMANN 13
Specification Vitocell 100-W (type CVB) (cont.)

Recommended arrangement of the cylinder temperature sensor for solar operation

A Cylinder temperature sensor


(solar control unit)
B Threaded elbow with sensor well
(standard delivery)

Delivered condition
Vitocell 100-W, type CVB, 300 litre capacity Vitocell-W 100, type CVB, 400 litre capacity
DHW cylinder made from steel with Ceraprotect enamel coating. DHW cylinder made from steel with Ceraprotect enamel coating.
& Protective magnesium anode & Protective magnesium anode

& Fitted thermal insulation made from rigid PU foam & Thermal insulation made from flexible polyurethane foam

& 2 welded sensor wells for cylinder temperature sensor or control (packed separately)
thermostat & 2 welded sensor wells for cylinder temperature sensor or control

& Fem. connection R 1½" for the installation of an EHO electric thermostat
immersion heater and plug R 1½" & Fem. connection R 1½" for the installation of an EHO electric

& Threaded elbow with sensor well immersion heater and plug R 1½"
& Adjustable feet & Threaded elbow with sensor well

The colour of the epoxy-coated sheet steel casing is white. & Adjustable feet

The colour of the plastic-coated thermal insulation is white.

5822 307-3 GB

14 VIESMANN VITOCELL-W
Pressure drop on the DHW side

Vitocell 100-W (type CWG and CUG)

Vitocell 100-W (type CVA)

A 160 and 200 litre


B 300 litre
5822 307-3 GB

VITOCELL-W VIESMANN 15
Pressure drop on the DHW side (cont.)

Vitocell 100-W (type CVB)

A 300 litre capacity


B 400 litre capacity

Vitocell 300-W (type EVA)

Accessories

Accessories for connection with wall mounted boilers


The connection sets for the connection of the DHW cylinders to Wall mounted DHW cylinders for wall mounted boilers
the respective wall mounted boilers are available as accessories If a self-supporting mounting frame is utilised for the wall mounted
and must be ordered separately. boiler, also order a self-supporting mounting frame for the DHW
See the pricelist for a detailed description. cylinder.

Safety assembly to DIN 1988


Safety assembly, comprising:
& Shut-off valve

& Non-return valve and test nipples

& Pressure gauge connector

& Diaphragm safety valve

For DHW cylinder:


& up to 200 litre capacity: DN 15/R ¾"

Max. heating load 75 kW


10 bar: Part no. 7219 722
a 6 bar: Part no. 7265 023
& 300 litre capacity: DN 20/R 1"

Max. heating load 150 kW


10 bar: Part no. 7180 662
a 6 bar: Part no. 7179 666
5822 307-3 GB

16 VIESMANN VITOCELL-W
Accessories (cont.)

Connection diagrams for DHW cylinders

Vitopend 200-W, Vitodens 200-W to 32 kW, Vitodens 300-W Vitodens 200-W from 45 kW with DHW cylinder with peripheral
and Vitoladens 300-W with internally heated DHW cylinder – heat exchanger – with external cylinder primary pump (acces-
with connection set and integral cylinder primary pump (via three- sories)
way valve)

HR Heating return
HR Heating return HV Heating flow
HV Heating flow SRL DHW return
SRL DHW return SVL DHW flow
SVL DHW flow

Design information

DHW connection
Connection to DIN 1988

A DHW H Flow regulating valve


B DHW circulation line (We recommend the installation and adjustment of the max.
C DHW circulation pump water flow rate in accordance with the 10 minute output of the
5822 307-3 GB

D Spring-loaded check valve DHW cylinder.)


E Visible blow-off line outlet K Pressure gauge connection
F Safety valve L Non-return valve
G Shut-off valve M Drain
N Cold water

VITOCELL-W VIESMANN 17
Design information (cont.)

O Potable water filter * 1 R Non-return valve/pipe separator


P Pressure reducer to DIN 1988-2 issue Dec.1988 S Diaphragm expansion vessel, suitable for drinking water

The safety valve must be installed. Recommendation: Install the safety valve higher than the top
edge of the cylinder. This protects the valve against contamina-
tion, scaling and high temperatures. The DHW cylinder must not
be drained when working on the safety valve.

Warranty
Our warranty for DHW cylinders requires that the water to be
heated meets the DHW quality in accordance with current potable
water regulations and that existing water treatment systems work
properly.

Heat transfer surface


The corrosion-resistant, protected heat transfer surface (DHW/
heat transfer medium) corresponds to type C in accordance with
DIN 1988-2.

Technical guide
For further information on design and sizing, see the technical
guide "Central DHW heating with Vitocell DHW cylinders" and

Printed on environmentally friendly,


Vitodens, Vitopend and Vitoladens technical guides.

chlorine-free bleached paper

Subject to technical modifications.

Viessmann Werke GmbH&Co KG Viessmann Limited


D-35107 Allendorf Hortonwood 30, Telford
Telephone: +49 6452 70-0 Shropshire, TF1 7YP, GB
5822 307-3 GB

Fax: +49 6452 70-2780 Telephone: +44 1952 675000


www.viessmann.com Fax: +44 1952 675040
E-mail: info-uk@viessmann.com
*1
According to DIN 1988-2, a drinking water filter should be installed in systems with metal pipework. Viessmann also recommends the
installation of a drinking water filter when using plastic pipes according to DIN 1988 to prevent contaminants entering the DHW system.

18 VIESMANN VITOCELL-W