Академический Документы
Профессиональный Документы
Культура Документы
Treatment
and Industrial
Applications
TeChNICal FeaTUreS
DIMENSION [inches]
603
Model 803
800
a (height) 9.09”
B (Width) 4.68”
C (Depth) 5.70” 5.86”
D (Max height) 10.11”
ANALOG VERSION
AKL [Constant dosage] with FPM level control input APG [Proportional dosage] with FPM level control input
Select from two frequency ranges (0÷20% or 0÷100%). analog dosing pump with constant flow rate manually adjustable,
The constant flow rate is easily adjusted with the analog control proportional flow rate according to an external analog (4÷20 ma)
dial, located on the front panel. or digital pulse signal (e.g. from water meter).
The Power-On led and level control indicators are also on this panel. l Control dial (percentage and "n" value in multiplication mode)
l 6 position adjustable switch:
- 3 in division mode (1, 4, 10 = n)
- 1 in multiplication mode (n=1)
- 1 for proportional 4÷20 ma signal
- 1 for constant functionality
l “pacing” function adjustable by dip switch
DIGITAL VERSION
The Kontrol 100-series are advanced controllers designed for simpler APPLICATIONS
high-end applications. The units feature an independent proportional
control output, probe quality checking and a variety of outputs . The l Waste Water l Galvanic Process
user has full programming authority. l Drinking Water l CIP
l Pure Water l Irrigation
l Cooling Towers l Swimming Pool
l Boiler l Sea water
l reverse Osmosis l Dairy
l Crate Wash
FEATURES
CONFIGUraTION OUTPUTS
all outputs relay, SSr and Output ma are configurable with primary
and secondary measure. MEASURE RANGE
CUrreNT OUTPUTS pH 0 ÷ 14,00 ph
4÷20ma Galvanic isolation . Two independent programmable Output ORP ± 2500 mV
Measures with Proportional routine regulation. Conductivity 0,054 ÷ 20 /200 /2.000 /20.000 /200.000 μS
Flow Rate 0 ÷ 99.999 liters/Sec.
relaY OUTPUTS Dissolved Oxygen 0 ÷ 20,0 ppm or mg/l - 0 ÷ 200% SaT
Two independent relays, two set points, alarm remote and back Chlorine and
0 ÷ 0,50/1,00 /2,00 /5,00 /10,0 /20,0 /200,0 ppm
washing probe setting by software. On/OFF, Timed routine function Chlo. Dioxide
setting. Hydrogen Peroxide 0 ÷ 500 /1000 /2000 /10.000 /100.000 ppm
Ozone (03) 0 ÷ 0,5 /2,00 /5,00 /10,00 ppm
SOlID STaTe relaY (SSr) Peracetic Acid 0 ÷ 500 /2000 /10.000 /20.000 ppm
Two Frequency output signal, two set points with Proportional routine Turbidity 0,00 ÷ 1,00 /10,0 /100 NTU/FTU
regulation. Temperature with PT100/PT1000 32 ÷ 212 °F (0 ÷ 100°C)
The Kontrol 500-series are advanced controllers designed for high-end APPLICATIONS
applications. The units feature independent proportional PID-enabled
control outputs, rS 485 serial port with MODBUS protocol, USB port l Waste Water l Galvanic Process
on request, probe quality checking, a variety of outputs and full data l Drinking Water l Dioxide Station
logging capability. The user has full programming authority. l Cooling Towers l CIP
l Boiler l Irrigation
l legionella disinfection l Swimming Pool
l reverse Osmosis l Fish Farming
l Sludge l Sea water
FEATURES
l Crate Wash l Dairy
DaTa lOGGING Internal Flash Memory with records interval from 1
to 99 min. (near to 16000 records). Visualization key for stored data in
tabular and graphic form. Type: Circular (F.I.F.O.) or Filling.
MEASURE RANGE
rS485 SerIal POrT For set-up and real-time data acquisition from pH 0 ÷ 14,00 ph
remote or for stored data download on PC or laptop (Communication ORP ± 1500 mV
Software Master Controller NeT required). MODBUS rTU Conductivity 0 ÷ 20 /200 /2.000 /20.000 /200.000 μS
communication protocol.
Inductive Conduct. 0 ÷ 10.000 /10.000 /100.000 /999.999 μS
Dissolved Oxygen 0 ÷ 20,0 ppm or mg/l - 0 ÷ 200% SaT
USB POrT Download measuring data on removable memory Usb
Pen Drive (upon request). Chlorine and
0 ÷ 0,50/1,00 /2,00 /5,00 /10,0 /20,0 /200,0 ppm
Chlo. Dioxide
Hydrogen Peroxide 0 ÷ 500 /1000 /2000 /10.000 /100.000 ppm
MeaSUre INPUT
Ozone (03) 0 ÷ 0,5 /2,00 /5,00 /10,00 ppm
l high measuring resolution with probe quality control.
l
Peracetic Acid 0 ÷ 500 /2000 /10.000 /20.000 ppm
a modular measuring system
l
Turbidity 0,00 ÷ 1,00 /10,0 /100 NTU/FTU
Chlorine measure in sea water application.
Suspended Solids 0,0 ÷ 4,00 /40,0 /400/4.000 NTU/FTU -
Turbidity 0÷30 gr/l
CUrreNT OUTPUTS 4÷20ma Galvanic isolation Two independent Temperature with PT100/PT1000 32 ÷ 212 °F (0 ÷ 100°C)
programmable. Output Measures with PID routine regulation.
relaY OUTPUTS Four independent relays, two set points, one alarm
remote output, one backwashing probe output. On/OFF, Timed
routine function setting.
SOUth AFriCA
n Seko Southern Africa
GermAny Tullytown - Pa 19007
n Seko Deutschland Gmbh (Pty) ltd
Phone: +1 215 945 01 25
55252 Mainz - Kastel Kyasand - Johannesburg - Fax: +1 215 945 09 37
info@seko-messtechnik.de Gauteng sales@sekousa.com
www.seko-germany.com sales@sekosa.co.za www.sekousa.com
Subject to change without notice. > © Seko Dosing Systems Corp. > 0000850001.BROW&I15A.US