Вы находитесь на странице: 1из 4

Design of Communal Septic Vault with Multi-

Medium Filtration Treatment at Purok Langan,


Kapalong, Davao del Norte
Shaina May L. Lipranum, Stephanie Bell A. Guinita, Charles John C. Torno
College of Engineering, University of Mindanao
Matina, Davao City, Philippines
shynalipranum@gmail.com
pamsguinita017@gmail.com
charls.torno@gmail.com

Abstract— Eliminating wastewater and direct discharging The removal of residual suspended solids and unsettled
into any water body had already been recognized as microorganisms may be achieved using filtration process [10].
undesirable impact contributor to the environment as they Also, filtration can reduce nutrients in the pretreated water.
carry pollutants such as abundance of nutrients and Moreover, it has been emphasized that sand filter produce
malodorous gases. This has therefore led to various effluent with very low ammonia levels that is responsible for
wastewater treatment techniques in view of environmental significant odors. It also helps avoid the need of chlorine dosage
sustainability. However, there is an inevitable problem that in the wastewater [16]. Filtration can improve both the physical
some parts of the world especially the least developed and microbial quality of water. The two common types of
countries, do not pay much attention to the importance of granular filters which are the slow sand filters and rapid sand
wastewater treatment. The main objective is to orient the filters. Though both are effective in removal of pathogens, they
locals specifically to the least developed communities on differ in the filtration rate of water [4], which means that slow
how to properly dispose domestic wastewater. Also, a sand has longer filter runs than the rapid one. Slow sand
lasting solution to mitigate the contamination of water requires a single sand medium which is always readily available
bodies is by designing a communal septic vault with multi- whereas the rapid sand uses dual or multimedia filters (sand,
medium filtration treatment. Sand and gravel filtration are coal and carbon).
more advantageous as a medium since it is readily available
and was proven to treat wastewater before dispatch. Since the existing water closets at Prk. Langan, Kapalong,
Davao del Norte are all connected to a single chamber known
Index Terms— Sand and Gravel Filtration, Wastewater, Septic as “Dry Well” in which the effluent flows directly towards the
Vault, Effluent water table by soil filtration. As a result, rivers were
contaminated as well as the pump wells of the residents nearby.
(reconstruct)
I. INTRODUCTION
Improper disposal of domestic or residential wastewater This will help the community to become more concern in
had already been recognized as one of the contributors of their surroundings. According to the purok’s barangay health
environmental pollution. Orientations and seminars, all in worker Mrs. Merlita Suminguil, water borne diseases were
informative conveyance of the causes and effects are spread to observed since 2010. In line with this, residence in this area
communities. However, some remoted areas still lack in should be oriented on how to properly dispose their domestic
knowledge of such learning hence emerges the problem. This wastes. They need to have an eco-friendly and sustainable
study attempts to improve the living conditions of the affected septic vault that the locals are already familiar. (reconstruct)
communities of the indigenous people and to minimize diseases
caused by water contamination. Safety is utmost important. By The result of this study will help the Indigenous People to
designing a communal septic vault having a layer of sand, and adapt proper sanitation and to prevent them from using the river
gravel filtration to apply basic filtration before disposing in to as their sanitary place, thus will save the river from being
the water bodies available in the area rather than disposing it contaminated. Therefore, this will serve as a building block for
directly from the septic vault. Sand and Gravel Filtration is an the future action to hand over excellent information and
extremely effective filter media because of its ability to hold suggestion to the community who’s in the remote areas and to
back precipitates containing impurities. These filter medias are the Department of Environment and Natural Resources
key factors in filtrating effluents allowing it to flow water (DENR). (reconstruct)
directly at the river.
Since the design of a septic vault is not limited to size and pipelines and culvert used to convey domestic wastewater to
volumes, this study clearly needs further development and the communal septic vault from houses.
continuation. The advocate of this study has made
recommendations for improvement. There is no doubt that the Site investigation. This activity includes a site inspection. The
treatment options provided, require mechanical and electrical researchers carry out a site visit in their respective areas to
equipment and processes. The design of this aspect is also determine the septic vault’s potential area.
recommended to undergo research and development under a
Sanitary Engineer. (reconstruct) Preliminary Output. This activity involves encoding, drawing
up the results of the site investigation and designing the septic
II. MATERIALS AND METHODS vault using AutoCAD software.
The diagram below summarizes the flow of this
research study. III. RESULTS AND DISCUSSION
In this part of the study, discussion and results are stated.
A. Conceptual Framework
A. Domestic Waste Orientation

RESIDENTIAL With the help of Local Government Units, orientation


UNTREATED WATER must be conducted for the awareness of the community
regarding proper disposal of domestic wastes.

B. Map Lay-out
PROPOSAL OF SAND
AND GRAVEL AS Figure 2 shows the map lay-out of sanitary network
MEDIUM IN FILTRATION located at Prk. Langan, Kapalong, Davao del Norte, which has
a recorded population count of 883 as of 2018. The map layout
of sanitary network presented the potential location of the
communal septic vault along with the pipelines. The encircled
COMPLETE portion in the map is a proposed area for installation of
DETAILING OF THE communal septic vault with its filtration tank. It’s a vacant area
DESIGN that measures around 200 sq. m. The total area of septic vault
is 158.4 and the filtration tank is 5 sq. m having a total area of
163.4 sq. m. so the said are can accommodate the maximum
RECOMMENDATION OF designed size. The potential area is less elevated and accessible
THE IMPLEMENTATION to all residential houses in the area. The sanitary network
OF THE DESIGN. consists of two types of pipelines, the House Sewer is the
pipeline conveying sewage from the houses to the main line
Fig. 1 Conceptual Framework while the Main Line is the pipeline that transports wastewater
to the septic vault.
This study focuses on the problem that some of the
communities are still not practicing proper sanitation. To
address this problem, the sand and gravel filtration design is
utilized in order for the effluent to be treated before dispatching
it to the river.
B. Research Materials and Equipment
AutoCAD 2015. Using this software, the detailing of the
design treatment facility shall be sketched and presented to
show the results on the design calculations. Details shall
include operator dimensions and material specifications.

C. Methods and Procedures


This study used the method of action research. It
initiates the problem of improper sanitation of the community,
which leads to continuous river contamination.
Fig.2 Map lay-out of Prk. Langan, Kapalong, Davao del Norte
Mapping. This activity includes the location of the site. The C. Design of Communal Septic Vault
researchers will create an outline map to show the layout of the
In 2018, the gathered population count was 883 person. local sewage system in order to improve our water bodies and
Based on this data, the following calculations have been drawn. conserve them. Sand and gravel are proven effective as a
House Sewer. Computed minimum required size based on the medium of filtration, due to its advantageous characteristics on
data’s gathered is 0.0854 mm or 8.54 m but since stated in the filtering wastewater.
book of Fajardo another way to determine the diameter of the
pipe to determine the number of fixtures involved, multiplied V. ACKNOWLEDGEMENT
by the corresponding fixture units in table 1. As a result, the The completion of this study would not have been
researchers ended up using the diameter of 50 mm PVC Pipe. possibly achieved without the help and guidance of the
individuals present who non-hesitatingly extended their support
Main Line Sewer. Computed minimum required size based on and time to us, proponents. To Engr. Marie Fe Y. Lacsado, our
the data’s gathered is 0.055 mm or 50.55 m but since the subject adviser, for believing and that we have the capability to
minimum size of a precast concrete culvert available is 150 finish this study; To Jose S. Condonar Jr., our thesis adviser,
mm, therefore 150 mm diameter is to be used. for his assistance, help and encouragement; To Engr. Esther
Fittings. In pipe systems, fitting is used to connect straight pipe Consuelo Tan, for her perseverance to check and to help the
or tubing sections, adopt to different sizes or shapes and for researchers’ data to be organized and well presented; To Engr.
other purposes such as control or measurement of fluid flow. In Meryl Mae Rodriguez for the assistance and ideas she shared to
the mapping layout from figure 2, the piping’s used were 124- us; To the researcher’s family and friends, for their
45 degrees elbow and 1 tee fitting with the same diameter as overwhelming spiritual, moral and financial support that made
the pipelines. this research be possible. For the family and friends of the
researcher, for their overwhelming spiritual, moral and
Septic Vault. Computed dimensions based on the population financial support that enabled this research. And above all to
data gathered has a total length of 10.8 m and a total width of the Almighty God for the gift of life, knowledge and wisdom
11 m, with a total area of 158.4 sq. m. The septic vault consists which enable us to succeed.
of two chambers which are the digestive and leaching chamber.
Digestive chamber has a total area of 7.2 m x 11m, while the VI. REFERENCES
[1] Fajardo, M. (n.d.). Plumbing Design and Estimate (2nd ed.)
leaching chamber has a total area of 3.6m x 11m. [2] Magtibay, B. (2006). Philippine Regulations on Sanitation and
Wastewater Systems. Retrieved on November 30, 2018 from
Sand and Gravel Filtration. Filter bed area to be used is 5 sq. http://www.itnphil.org.ph/docs/sanitation%20-%20wastewater%
m per filter. The depth of sand and gravel are 1.2 m and 0.6 m 20-magtibay.pdf
respectively [17]. [3] Spellman, F.(2013). Handbook of Water and
Wastewater Treatment Plant Operations. Florida: CRC Press
[4] Striebig, B., Ogundipe, A., Papadakis, M. (2016). Engineering
Applications in Sustainable Design and Development (1st ed.).
USA: Cengage Learning
[5] Water Purification/ Wastewater Treatment (n.d.). Retrieved on
April 27, 2018 from https://whlc.co.nz/websters_case-
study/wastewater-treatment/
[6] Sedimentation Basin Design and Problems. (n.d.). Retrieved
on April 29, 2018 from https://www.google.com.ph/url?sa=t&
source=web&rct=j&url=http://sgpwe.izt.uam.mx/files/users/uami
/sho/SedimentationBasinDesign.doc&ved=2ahUKEwjJ_9eD0vba
AhWMlpQKHSakaRYQFjAXegQIARAB&usg=AOvVaw3ZwJ6e
nF6eMm_bSwxYQVwS
[7] Preliminary Treatment. (n.d.). retrieved on April 24, 2018 from
http://site.iugaza.edu.ps/frabah/files/2011/09/2.Preliminiarytreatme
nt-.pdf
[9] Claudio, L. (2015). Wastewater Management in the Philippines.
Retrieved on October 2017 from www.wipo.int/edocs/mdocs/mdoc
s/en/wipo_ip_mnl_15/wipo_ip_ mnl _15_t4.pdf
[10] Cornwell, D. and Davis, M. (2013). Introduction to
Environmental Engineering (5th ed.). New York: McGraw Hill
[11] Davis, M. (2010). Water and Wastewater Engineering Design
Principles and Practice. Retrieved on October 2017 from
https://adminimages.muhandes.net/content/library/5cef8f7142f947
a8ad18eedb881df780.pdf
[12] Design Examples. (n.d.). Retrieved on April 12, 2018 from
ttp://web.deu.edu.tr/atiksu/toprak/ani414.html
[13] Hager, W. (2010). Wastewater Hydraulics Theory and Practice
IV. CONCLUSIONS AND FUTURE WORKS (2nd ed). London, New York: Springer
The main goal of this study is to provide an innovative [14] Silbajoris, A. (2017). What is Lime Used for in Wastewater
Treatment? April 27, 2018 from https://sciencing.com/lime-used-
and practical method of disposing domestic wastewater water-treatment-5023964.html
properly. It is recommended that this study be carried out in [15] Water Purification/ Wastewater Treatment (n.d.). Retrieved on
order to raise awareness of the importance and urgency of the April 27, 2018 from https://whlc.co.nz/websters_case- study/
wastewater-treatment/
[16] Parten, S. (2014). Planning and Installing Sustainable Onsite
Wastewater Systems. USA: McGraw Hill
[17] https://ebookcetral.proquest.com/lib/uniofmindanao-
ebooks/reader.action?doc ID=311672&query=filtration