AFWALL® MILLENIUM™ FloWise®

1.1 GPF FLUSHOMETER TOILET SYSTEM


SELECTRONIC ® EXPOSED AC FLUSH VALVE
BARRIER FREE

AFWALL® MILLENIUM™ FloWise ® 1.1 GPF


FLUSHOMETER TOILET SYSTEM
❏ 2257.711 1.1 gpf Exposed Top Spud Bowl
and Selectronic ® Exposed AC Flush Valve

BOWL:
• Wall-hung elongated flushometer valve toilet
• Vitreous china
• High Efficiency. Operates in the range of 1.1 gpf to
1.6 gpf (4.2 Lpf to 6.0 Lpf)
• Powerful direct-fed siphon jet action
• Fully-glazed 2-1/8" trapway
• Condensation channel
• 1-1/2" inlet spud
• 10" x 12" water surface area
• 100% factory flush tested
• Bolt caps and seat not included
• Model 2257.101

SELECTRONIC ® FLUSH VALVE:


• Self-Cleaning Piston with integral wiper spring
significantly reduces clogging and maintenance
• Selectronic ® Proximity System with universal sensor
provides hygienic, "hands free" operation
• State-of-the-Art Electronics prevent ghost flushing
SEE REVERSE FOR ROUGHING-IN DIMENSIONS
• Dezincification Resistant semi-red brass alloy
• Fully Mechanical Manual Override Button can flush High-Efficiency Toilet System
the valve without power
• Fail-Safe: Valve automatically closes upon loss of power •3 1.3% water savings when compared to
or water pressure and does not need to be reset 1.6 gpf toilet systems
• Adjustable Sanitary Flush cleans the fixture & maintains
the trap seal. System MaP Score:
• Chemical Resistant EPDM Seals for extended life • 1,000 grams of miso @ 1.1 gpf
• Adjustable Tailpiece for rough-in flexibility * Maximum Performance (MaP) testing performed by
IAPMO R&T Lab. MaP Report conducted by Veritec
• Can be installed left or right handed Consulting, Inc. and Koeller and Company
• Includes Class 2 UL certified universal hard-wired
AC transformer Operating Pressure:
• Optional cover plate only required for installation 25 psi (flowing) - 80 psi (static)
from the front
• Model 6067.111 Flow Requirement:
Includes: 25gpm (94.6 L/min.)
•  047007-0070A Inlet Spud (furnished with bowl)
Nominal Fixture Dimensions:
•  481310-100 2 Bolt caps with retainers (furnished
with bowl) 660 x 356 x 381mm (26" x 14" x 15")
•  1" I.P.S. angle stop with back-flow protection
and vandal resistant cap
•  1" Sweat solder kit including cover tube and wall flange
•  1-1/2" High back pressure vacuum breaker,
spud coupling and flangee To Be Specified:
❏ Color: ❏ White
❏ Seat:
❏ American Standard #5901.100
Heavy duty open front less cover
❏ American Standard #5905.100
Extra heavy duty open front less cover

© 2016 AS America Inc.


N137
spec_2257.711 Afwall Millenium FW 1.1gpf Rev. A 6/16
AFWALL® MILLENIUM™ FloWise®
2257.712 1.1 GPF FLUSHOMETER TOILET SYSTEM
2257.716 SELECTRONIC ® EXPOSED AC FLUSH VALVE
BARRIER FREE
3351.711
Fixture Compliance
3351.712 Certifications - Valve Listings:
Meets or 3351.716
Exceeds the Following Specifications: • ASSE 1037
• ASME A112.19.2-2008 / CSA B45.1-08 for • ANSI/ASME A112.19.2
Vitreous China Fixtures • ADA Compliant

Hubbel-RACO 8192 4" ELECTRICAL BOX 356mm


OR EQUIVALENT BY CONTRACTOR (14")

FINISHED WALL

660mm 180˚ 72mm


51mm (2") HOLE 73mm (26") (2-7/8")
FOR CONDUIT (2-7/8") 45˚
305mm
(12" MAX.)
15˚ SUPPLY
DN 25mm
DETECTION ZONE (1" I.P.S.)
400mm-800mm
86mm (15-3/4" TO 31-1/2")
(3-3/8")
470mm ROUGH-IN
409mm -C-L- (18-1/2") -C-L-
(16-1/8") DIMENSION
*CRITICAL 108mm -134mm 293mm
C/L OF SEAT POST LEVEL (4-1/4" - 5-1/4") (11-1/2")
HOLES 140 mm
(5-1/2") CENTER (4) Ø 22mm
(7/8") HOLES

229mm
(9") 191mm
381mm
(7-1/2")
(15")
333mm
(13-1/8")
133mm
(5-1/4")

41mm FINISHED
(1-5/8") FLOOR

*Note: The Critical Line (-C-L-) on Vacuum Breaker


must typically be a minimum of 152mm (6") above
fixture. Consult Codes for details.

VALVE LEFT or RIGHT HAND INSTALLATION

MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES


AND ANSI A117.1 ACCESSIBLE AND USABLE BUILDINGS AND
FACILITIES - CHECK LOCAL CODES.
When installed so that top of seat is 432 to 483mm (17" to 19") from the finished floor.

NOTES:
WASTE OUTLET SEAL RING MUST BE NEOPRENE OR GRAPHITE-FELT (WAX RING
NOT RECOMMENDED).
SUGGESTED 2mm (1/16) CLEARANCE BETWEEN FACE OF WALL AND BACK OF BOWL.
TO COMPLY WITH AREA CODE GOVERNING THE HEIGHT OF VACUUM BREAKER ON
THE FLUSHOMETER VALVE, THE PLUMBER MUST VERIFY DIMENSIONS SHOWN FOR
SUPPLY ROUGHING.
CARRIER FITTING AS REQUIRED TO BE FURNISHED BY OTHERS.
PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORT.

IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of
tolerances established by ANSI Standard A112.19.2.
These measurements are subject to change or cancellation. No responsibility is assumed for
use of superseded or voided pages

© 2016 AS America Inc.


N138