Marine boilers used in ships today are mostly for auxiliary purposes in vessels that run on marine diesel
engines or diesel electric propulsion. In case of ships using steam turbines (mostly found in high speed
vessels used by navies), boilers are a part of the main propulsion system. However, in this article, we will
focus on auxiliary boilers, i.e. boilers used for running auxiliary systems in a ship.

To look at this from a ship designer’s point of view, he/she should be able to choose the right kind of
boiler for a particular ship depending on the requirement for that particular project. The process is pretty
much an application of first principles, but in a somewhat different way.

4.8K
o SHARES 4.8K 11 40 4

1 of 18 4.9.2017. 8:32
Choosing A Marine Boiler While Designing A Ship http://www.marineinsight.com/tech/boiler/choosing-marine-boiler-de...

Ads by Google

To rate a boiler, one first needs to correctly estimate the steam output required from a boiler for the ship
being designed. For this, the three main requirements are:

Requirement 1 – Steam consumption required to compensate heat losses in tanks.

Requirement 2 – Steam consumption required to raise the temperature of fuel oil in tanks.

4.8K
o SHARES 4.8K 11 40 4

2 of 18 4.9.2017. 8:32
Choosing A Marine Boiler While Designing A Ship http://www.marineinsight.com/tech/boiler/choosing-marine-boiler-de...

We will discuss each of the requirements, and once done, we will see how the obtained data is used to
estimate the capacity of the boiler.

Requirement 1- Steam consumption required to compensate heat losses in tanks:

Most ships run by diesel engines have fuel oil tanks that are used to store Heavy Fuel Oil (HFO). Since
the viscosity of HFO is very high, stored HFO is almost as dense as tar, and its high viscosity makes it
unable to flow. But in order to transfer the stored HFO to the settling tanks and then the HFO service
tank, the viscosity needs to be maintained at a level corresponding to which easy flow is possible. For
this, HFO storage tanks are equipped with heating coils to maintain the fuel at a certain temperature.
The heating fluid in the heating coils is steam that is produced in the auxiliary boiler.

First, each HFO storage tank is located in the general arrangement drawing, and the surrounding space
adjacent to each tank bulkhead is noted. Depending on the surrounding of each tank bulkhead (Engine
Room, Void, Ballast Water Tank, Sludge Tank, etc.) the ambient temperature is fixed for heat transfer
through each bulkhead of the tank in analysis.

The amount of steam flow rate required to maintain the temperature of fuel in each such tank is
calculated using the following steps:

Heat loss from tank bulkhead

Q1 = U A (T2 – T1)

Where

Qb = heat loss from bulkhead (W)


4.8K
o SHARES 4.8K 11 40 4

3 of 18 4.9.2017. 8:32
Choosing A Marine Boiler While Designing A Ship http://www.marineinsight.com/tech/boiler/choosing-marine-boiler-de...

U = overall heat transfer co-efficient (W/m2 0C)

A = Area of tank bulkhead under consideration (m2)

T2 = Temperature of the tank to be maintained (0C)

T1 = Temperature of the adjacent medium of the bulkhead considered (0C)

Heat loss from tank Qt = Sum of heat loss from all the six bulkheads of the tank

Q1 = sum of heat loss from all the tanks

As we know the heat transfer rate, the mass flow rate of steam can be calculated using the following
formula :

ms = Q1 / ∆h

Where,

ms = mass flow rate of steam (kg/s)

Q1 = calculated heat transfer (kW)

∆h = enthalpy drop of the steam (kJ/kg)

4.8K
o SHARES 4.8K 11 40 4

4 of 18 4.9.2017. 8:32
Choosing A Marine Boiler While Designing A Ship http://www.marineinsight.com/tech/boiler/choosing-marine-boiler-de...

Zorg Biogas
Ukraine Ltd

Requirement 2- Steam consumption required to raise the temperature of fuel oil in tanks:

Not only is steam required to compensate the heat losses from fuel oil tanks, but steam is also used to
heat the fuel oil to required temperature before being used in the engine.

4.8K
o SHARES 4.8K 11 40 4

5 of 18 4.9.2017. 8:32
Choosing A Marine Boiler While Designing A Ship http://www.marineinsight.com/tech/boiler/choosing-marine-boiler-de...

follows:

∆T/t

For Storage Tank – 0.2 DEG C/HR RISE IN TEMP.


Service and Settling tank – 4 DEG C/HR RISE IN TEMP.
All other Tanks – 1 DEG C/HR RISE IN TEMP.

This calculation includes two steps:

Calculation of heat (Q in watts) required to heat contents of each tank, and summation of all the
individual heat requirements to obtain total heat transfer required to raise the temperature of fuel
oil in tanks (Q2)
Utilising the above obtained heat requirement to find the required mass flow rate of steam for
this purpose.

A sample of this calculation is shown below:

The amount of heat required to raise the temperature of fuel oil tanks can be expressed as:

Q2 = m Cp dT / t

Where Q2 = mean heat transfer rate (kW)

m = mass of fuel oil in the tank (kg)

Cp = specific heat capacity of the fuel oil (kJ/kg oC)

dT = Change in temperature of the fuel oil (oC)

t = total time over which the heating process occurs (hours)

As we know the heat transfer rate, the mass flow rate of steam can be calculated using the following
formula :

ms = Q2 / ∆h

Where ms = mass flow rate of steam (kg/hr)


4.8K
o SHARES 4.8K 11 40 4

6 of 18 4.9.2017. 8:32
Choosing A Marine Boiler While Designing A Ship http://www.marineinsight.com/tech/boiler/choosing-marine-boiler-de...

Q2 = calculated heat required to raise the temperature (kW)

∆h = enthalpy drop of the steam (kJ/kg)

Requirement 3- Steam consumption required for other services:

Steam is also used in ships to cater to other heating requirements, some of which are listed below:

Used as a heat exchange medium in Heavy Fuel Oil purifiers, Light Diesel Oil purifiers, and Lube
Oil purifiers.
Steam used as a heating medium in booster modules.
To pre-heat main engine jacket cooling water.
Used as a heating medium in calorifiers (calorifiers are high pressure storage units of heated
water, which is used in gantry and toilet utilities).

Heat requirement by all such services are calculated individually and added. The obtained heat
requirement is termed as Q3 (for the purpose of this article only).

Once the heat requirements for the three purposes (mentioned above) are obtained, they are added to
obtain the Total Heat Rate and Total Steam Mass Flow Rate Required for the boiler:

Total Heat Rate Required (Q) = Q1 + Q2 + Q3 (kW)

Total Mass Flow Rate Required is calculated from the relation: mS = Q / ∆h (kg/hr)

Where, ∆h = enthalpy drop of the steam (kJ/kg)

Now, there are two rating systems to obtain a suitable boiler:

From and At Rating:

4.8K
o SHARES 4.8K 11 40 4

7 of 18 4.9.2017. 8:32
Choosing A Marine Boiler While Designing A Ship http://www.marineinsight.com/tech/boiler/choosing-marine-boiler-de...

In the above graph, the vertical axis corresponds to the steam output as a percentage of the from and at
rating, at different pressures. That is, for example:

At 15 bar,

If feed water temperature is 68 degree Celsius,

Then the percentage from and at rating from the graph is 90%

So if a boiler has a rated steam output of 2000 kg/hr, the actual steam output of the boiler will be 90%
of the rated output, which is 1800 kg/hr.

Now, when a designer chooses a boiler, he/she needs to specify the rated steam output to the boiler
manufacturer. The boiler manufacturer, along with the boiler, provides the boiler from and at rating graph
for the proposed boiler, and the above calculation is carried out for various boiler pressures and feed
water temperatures, to check that the actual steam output is more than the steam flow rate (mS)
obtained in the initial design calculations that we have previously discussed.

4.8K
o SHARES 4.8K 11 40 4

8 of 18 4.9.2017. 8:32
Choosing A Marine Boiler While Designing A Ship http://www.marineinsight.com/tech/boiler/choosing-marine-boiler-de...

Zorg Biogas
Ukraine Ltd

Kilowatt Rating:

While some boiler manufacturers prefer from and at ratings, some others prefer another system called
the Kilowatt rating system, which is however just a different way of expressing the same data.

In order to obtain the Actual Steam Flowrate from the kW rating of a boiler, the following relation is used:

In the above expression, the energy to be added refers to the amount of energy added to the boiler by
the feed water (which in turn depends on the feed water temperature).

The designer should make sure that the steam output obtained above is more than the steam flow
rate (mS) obtained in the initial design calculations that we have previously discussed.

The above checks are to carried out at various working pressures of the boiler, and different ranges of
feed water temperature, depending on the steam requirement at various sailing conditions. It is to be
ensured that the chosen boiler meets the requirements in all such conditions, at different load
combinations.

4.8K
o SHARES 4.8K 11 40 4

9 of 18 4.9.2017. 8:32
Choosing A Marine Boiler While Designing A Ship http://www.marineinsight.com/tech/boiler/choosing-marine-boiler-de...

The type of boiler to be used in the ship is also to be chosen by the designer based on the following
criteria:

Functionality of the boiler.


Space Constraints.

For most auxiliary boilers, shell and tube boilers are used, where the boiler drum holds the water
reserve, and fire tubes run along the length of the drum. The hot gases produced by the burner are
carried in the fire tubes that provide more surface area for heat transfer to the water. In most cases, the
auxiliary boilers are horizontally oriented in case there are no space constraints, as they prevent
pressure fluctuations which is more in case of vertically oriented boilers.

However, for exhaust gas economisers or exhaust gas boilers (These are boilers that do not have a
furnace. They are also fire tube boilers, where exhaust gases from the engine are passed through the
fire tubes to heat the water in the boiler drum.) vertical configurations are preferable, as it provides less
back pressure on the exhaust gas system. Exhaust gas boilers are used when the vessel is on voyage,
and when in port, the auxiliary boiler is used.

Report an Error

Tags: boiler marine boiler ship boiler

Want to share your tips and advice? Got questions? Visit the community forum to ask questions,
get answers, meet people, and share your tips!

4.8K
o SHARES 4.8K 11 40 4

10 of 18 4.9.2017. 8:32