To add and delete users in card and PIN mode ( 3 1 # ) To unlock the door To remove the alarm Transmission

door To remove the alarm Transmission Format:

For a PIN user ◆ 1: Keypad Transmission


Add the card as for a card user Enter the PIN then press # To reset the Door Forced Open warning Read valid card or Master Code #
To add a card and PIN user The Reader will transmit the PIN data when it receives the last key (#) press after
(The PIN is any four digits between Press * to exit from the programming mode For a card user Read card
PIN code.
0000 - 9999 with the exception of Then allocate the card a PIN as follows: To reset the Door Open Too Long warning Close the door or Read valid card or Master Code #
1234 which is reserved.) * Read Card 1234 # PIN # PIN # Format: Facility Code + PIN Code
For a card and PIN user Read card then enter PIN # (Facility code is any digits between 0-255, factory default is 0; Pin code is any 4
To set the facility code
digits between 0000-9999)

W1-B Waterproof
Example: Facility code: 1
To change a PIN in card and PIN 10.2 Door Relay, Door Open Detection, Alarm, Facility code Settings To set the facility code of W1-B 8 Facility code # Repeat Facility code # PIN code: 5678
mode (Method 1)
(This operation might be required Facility Code can be any number between 1- Press 5678 #, then the output format will be: 00105678
Note that this is done outside * Read Card Old PIN # New PIN # New PIN #
programming mode so the user Door relay time setting when W1-B is acting as wiegand 255 (Default: 0)
reader and connecting to multi- ◆ 2: Proximity Card Transmission
can undertake this themselves

To change a PIN in card and PIN


Door relay time setting 4 0-99 #
The door relay time is between 0-99 seconds,
door controller.) The Reader will transmit the card data when it reads the Card.
Keypad/Reader/Controller
Format: Card Number (the last 8 digits of Card Number)
mode (Method 2) the factory default setting is 5 seconds.
Note that this is done outside * ID number# Old PIN # New PIN # New PIN # Remarks: No matter the card or PIN is valid or invalid, the data will be transmitted
W1-B Quick Reference Programming Guide programming mode so the user 11. Interconnecting Two Devices
can undertake this themselves Door Open Detection
To enter the programming mode * Master code # 11.2 W1-B operating as a Controller
888888 is the default factory master code To delete a Card and PIN user just Door Open Too Long (DOTL) warning. When used with an optional magnetic contact 11.1 W1-B Operating as a Wiegand Output Reader
delete the card 2 User ID # or built-in magnetic contact of the lock, if the door is opened normally, but not closed In this mode the W1-B supports a Wiegand 26 bits input so an external Wiegand
To exit from the programming mode * In this mode the W1-B supports a Wiegand 26 bit output so the Wiegand data lines can
after 1 minute, the inside buzzer will beep automatically to remind people to close device with a 26 bits output can be connected to the Wiegand input terminals on the
Note that to undertake the following programming the master user must be logged in the door and continue for 1 minute before switching off automatically. be connected to any controller which supports a Wiegand 26 bits input. See figure 1. W1-B. Either an ID card reader (125KHZ) or an IC card reader (13.56MHZ) can be
To add a card user in card only mode ( 3 0 # )
Door Forced Open warning. When used with an optional magnetic contact or built-in
magnetic contact of the lock, if the door is forced open, or if the door is opened after
connected to the W1-B. Cards are required to be added at the external reader, except
where an external EM reader is used, in this case cards can be added at either reader
1 2
To change the master code
The master code is any 6 digits The operating is the same as adding and deleting 120 seconds of the electro-mechanical lock not closed properly, the inside buzzer or controller. See figure 2.
To add and delete a card user a card user in 3 2 # and alarm output will both operate. The Alarm Output time is 1 minute. Pink
3 4
1 User ID number # PIN # GND

The ID number is any number between 1 - 2500. To delete All users D0


Green
D0
Special Power Supply 5 6
DC 12V /3A
The PIN is any 4 digits between 0000 - 9999 To disable door open detection. Pink
To add a PIN user 6 0 # White
with the exception of 1234 which is reserved. To delete ALL users. Note that (Factory default setting) D1 D1 GND
Green
Wiegand reader NC COM NO +12V GND OPEN
7 8
Users can be added continuously without exiting this is a dangerous option so use 2 0000 # D0 D0
GND Grey ALARM-
with care
programming mode To enable door open detection 6 1 #
V+ Yellow OPEN
D1
White
D1
+ - -
9 0
Exit button +
To add a card user 1 Read Card # ALARM-
Grey GND Fail Safe lock Fail Secure lock

Cards can be added continuously without Brown D_IN


exiting from programming mode To add and delete card users by Manager cards
Keypad Lockout & Alarm Output options. If there are 10 invalid cards or 10
incorrect PIN numbers in a 10 minute period either the keypad will lockout for 10 Red
OPEN
Yellow V+
+
#
AC&DC Brown Door detecting switch
minutes or the alarm will operate , depending on the option selected below. D_IN -

Manager add card Read card Manager add card Black AC&DC Red Alarm
To add card user by Manager Add Card AC&DC
To delete a PIN or a card user Cards can be added continuously.
Users can be deleted continuously without V+ Blue NO Black
Normal status: No keypad lockout AC&DC
exiting from programming mode 7 0 # (Factory default setting)
or alarm GND COM Blue
Manager delete card Read Card Manager delete card Purple NO
To Unlock the door To delete card user by Manager
Delete Card Cards can be deleted continuously. 7 1 # Power COM
Purple
Keypad Lockout Orange NC
Controller Orange
(With Wiegand 26 inPut) NC
Alarm Output 7 2 # (Alarm output time:1 minute)
Present the card W1-B
W1-B

.7. .8. .9. .10.


User Manual
l
Built in buzzer 6. Wiring 9. Sound and Light indication
1. Packing list l
Red, yellow and green LED display the working status Power
Pink DC 12V /3A
l
12-24V DC/12-18V AC GND
Name Quantity Remark Colour Function Description NC COM NO +12V GND OPEN
Operation Status Red Light Green Light Blue Light Buzzer
l
Two- year warranty D0
Green Wiegand D0 1 User ID number # PIN #
Digital Keypad W1-B 1 Green D0 Wiegand Output D0 White Wiegand D1
Power on Bright - - Short Ring To add a PIN users The ID number is any number between 1 -
D1
Exit button + - - + Stand by Bright - - - 2500. The PIN is any four digits between 0000
User Manual 1 White D1 Wiegand Output D1 ALARM-
Grey Fail Safe lock Fail Secure lock

Yellow
Press keypad - - - Short Ring - 9999 with the exception of 1234 which is
4. Specifications Grey Alarm - Alarm Negative OPEN
Screw Driver 1 Operation successful - Bright - Short Ring
Brown Door detecting switch + reserved. Users can be added continuously
Rubber Bungs 6*27mm, used for fixing Yellow OPEN Request to Exit Button D_IN Alarm“-” - Operation failed - - - 3 Short Ring
4  Red Alarm
without exiting from programming mode as
Brown D-IN Door Contact AC&DC Enter into programming mode Bright - - Short Ring follows:
Self Tapping Screws 4 3.5*27mm, used for fixing Operating Voltage 12-24V DC/12-18V AC Operating Humidity 5%- 95% RH Black
Red AC&DC
AC&DC In the programming mode - - Bright - 1 User ID No 1 # PIN # User ID No 2 # PIN #
User Capacity 2500 Environment Conforms to IP68 12-24V DC/12-18V AC Power Input Blue
Manager Card 2 Manager Add Card & Manager Delete Card NO Bright - - Short Ring
Black AC&DC 12-24V DC/12-18V AC Power Input Purple Exit from the programming mode
Keypad 12 keys, 2 x 6 digits Adjustable Door Relay time 0-99 seconds COM - - - -
Please ensure that all the above contents are correct. If any are missing please notify To delete a PIN user 2 User ID number #
Adjustable Alarm Time 0-3 minutes Blue NO Relay NO Orange
- Bright - Short Ring
the supplier of the W1-B. Card Type EM 125 KHZ card/Tag NC Open the door Users can be deleted continuously without
Purple COM Relay COM Alarm Bright - - Alarm
Card Reading Distance 3-6 cm Wiegand Interface Wiegand 26 input & output exiting programming mode
2. Description Orange NC Relay NC
W1-B
Active Current <80mA Electric Lock, Exit Button, Special Power Supply
Wiring Connections To change the PIN of a PIN user
Pink GND W1-B Negative
W1-B is a single door multifunction access controller or a Wiegand output keypad or
Idle Current ≤40mA DOTL, External Alarm (Note:This step must be done out of * ID number # Old PIN # New PIN # New PIN #
card reader. It is suitable for mounting either indoor or outdoor in harsh environments. It Lock Output Load Max 2A Dimensions L135 x W58 x H26 mm Notes: programming mode)
is housed in a strong, sturdy and vandal proof Zinc Alloy electroplated case. Alarm Output Load Max 20A Net Weight 550 g Connection Diagram
The electronics are fully potted so the W1-B is waterproof and conforms to IP68.
Connect the negative pole of the lock to NC is for Fail safe lock. 10. W1-B Detailed Programming Guide To add a card user (Method 1) 1 Read Card #
Operating Temperature -20℃-60℃℃ Gross Weight 700 g Connect the negative pole of the lock to NO is for Fail secure lock. This is a fast way to enter cards
The W1-B supports up to 2500 users in either a Card, 4 digits PIN, or a Card + PIN Alarm Cards can be added continuously without exiting
+ using ID number auto generation. programming mode
option. The inbuilt card reader supports EM 125KHZ frequency card/Tag. The W1-B has Power“+”
Alarm “-” -
10.1 User Settings
many extra features including block enrollment, wiegand 26 bits interface, and backlit Pink To add a card user (Method 2)
5. Installation GND To enter the programming mode * Master code #
keypad...etc. This is the second way to enter
Green Power 888888 is the default factory master code
These features make the W1-B an ideal choice for door access not only for small shops D0 cards using User ID Allocation.
l
Remove the back cover from the keypad using the supplied security screwdriver 12-24V DC/ 1 ID Number # Card #
and domestic households but also for commercial and industrial applications such as
l
Drill 4 holes on the wall for the screws and I hole for the cable D1
White 12-18V AC/3A 7. To Reset to Factory Default To exit from the programming mode * In this method a User ID is allocated
factories, warehouses, laboratories, banks and prisons. Exit button to a card. Only one user ID can be
l
Fix the back cover firmly on the wall with 4 flat head screws ALARM-
Grey Note that to undertake the following programming the master user must be logged in allocated to a single card.
l
Thread the cable through the cable hole Yellow To reset to factory default, power off, press * , hold it and power on, release it until
OPEN 0 New code # New code # 5 ID number # 8 digits Card number # Card quantity #
l
Attach the keypad to the back cover hear two beeps and the LED shines in orange, then read any two EM cards, the LED will To change the master code
Brown Door detecting switch
The master code is any 6 digits. To add card user (Method 3) Card quantity is between 1-2500.
3. Features D_IN turn in red, means reset to factory default setting successfully. Of the two EM cards The 8 digits card number is the last 8 digits on
Add a series cards users
Red read, the first one is Manager Add card, the second one is Manager Delete card. Setting the working mode: the card.
AC&DC Block Enrollment
l
Waterproof, conforms to IP68 Black Maximum 2500 cards can be enrolled at a stretch
AC&DC Remarks: Reset to factory default, the user's information is still retained. within 3 minutes.
l
Strong zinc alloy electroplated anti-vandal case 1 2 Set valid card only users 3 0 # Entry is by Card only

ALARM-

AC&DC

AC&DC
Blue

OPEN
l
Full programming from the keypad NO To delete card user by card

D_IN

COM
GND
3 4

D0

D1
ALARM-

NO
AC&DC

AC&DC

NC
OPEN

D_IN

COM
GND

D0

D1

NO

NC
l
2500 users, supports Card, PIN, Card + PIN Purple number
5 6 J1 COM Set valid card and PIN users
l
Can be used as a stand alone keypad
3 1 # Entry is by Card and PIN together Note: Users can be deleted 2 Read Card #
7 8
NC
Orange 8. Anti Tamper Alarm continuously without exiting
l
Programmable one relay output 9 0 J1 Power“+” + Set valid card or PIN users 3 2 # Entry is by either Card or PIN (default) from programming mode.
l
Backlight keypad Anti-demolition alarm

In4004
# Electric bolt:NC Lock
l
Wiegand 26 bits input & output W1-B - The W1-B uses a LDR (light dependent resistor) as an anti tamper alarm. If the keypad
Electric strike:
NO
is removed from the cover then the tamper alarm will operate. To delete a card user by user ID
l
Adjustable door output time, alarm time, door open time
This option can be used when a 2 User ID #
l
Block enrollment, can enroll maximum 2500 consecutive card within 3 minutes user has lost their card
To add and delete users in either card or PIN mode ( 3 2 # ) (Default setting)
l
Very low power consumption (60Ma)
l
Fast operating speed, <20ms with 2500 users Common Power Supply
l
Easy to install and program W1-B PCB connect diagram
l
Built in light dependent resistor (LDR) for anti tamper
.1. .2. .3. .4. .5. .6.