Вы находитесь на странице: 1из 4

D

N° x Ø

ØC
ØA
ØB

All Dimension in mm.

Weight Max.Motor* Weight Max.Motor*


MODEL A B C D N  ( kg ) FrameSize MODEL A B C D N  ( kg ) FrameSize

315 315 355 395 200 8 10 6 D71 710 710 755 810 406 18 12 30 D112M

355 355 395 435 200 8 10 7 D80 800 800 845 900 406 18 12 40 D132M

400 400 440 480 235 12 10 7.5 D90S 900 900 945 1000 495 18 12 51 D160M

450 450 490 530 255 12 10 8 D90L 1000 1000 1050 1100 550 24 12 57 D160M

500 500 540 580 285 12 10 11 D90L 1120 1120 1185 1250 650 24 12 96 D225M

560 560 605 660 346 12 10 16 D112M 1250 1250 1315 1380 700 24 12 147 D250M

630 630 675 730 346 12 10 18 D112M 1400 1400 1465 1530 770 32 14 171 D250M

* Motor frame size beyond this range, please consult KRUGER for details.
* Weight without motor and impeller.

The company is always improving and developing its products, therefore the company reserves the right of making changes to the illustrated products.
Certified dimension can be provided upon request.

A member of
LEA006.E1 03/06
Edition 2 NO. 10 Buroh Street #06-06, West Connect Building,
Printed on Jun 12 Singapore-627564
QUICK SELECTION GUIDE – 50 Hz
2 POLES - 2800 RPM

Hst (Pa)
1400

1200

1000

800 630

560
600
500
450
400
400
355
200 315

0 1 2 3 4 5 6 7 8
Air Flow (M3/S)

4 POLES - 1420 RPM

Hst (Pa)
320

280

240
630
200
560
160
500
120
450

80 400

40 355
315

0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5


Air Flow (M3/S)

4 POLES - 1420 RPM

Hst (Pa)
1200

1000

800
1250

1120
600
1000
400
900
800
200 710

0 3 6 9 12 15 18 21 24 27 30
Air Flow (M3/S)

*** Shaded portion is the recommended operating range based on the duct velocity consideration (friction loss of 1 Pa/m)
QUICK SELECTION GUIDE – 50 Hz
6 POLES - 900 RPM

Hst (Pa)
210

180

150

120
800
90
710

60 630

560
30 500
450

0 1 2 3 4 5 6 7 8
Air Flow (M3/S)

6 POLES - 900 RPM

Hst (Pa)
600

500

1400
400

1250
300
1120

200
1000

100 900

0 5 10 15 20 25 30 35
Air Flow (M3/S)

8 POLES - 720 RPM

Hst (Pa)
400

350

300
1400
250
1250
200

150 1120

100
4 POLES - 1750 RPM1000
900
50 800

0 3 6 9 12 15 18 21 24 27 30
Air Flow (M3/S)

*** Shaded portion is the recommended operating range based on the duct velocity consideration (friction loss of 1 Pa/m)
QUICK SELECTION GUIDE – 60 Hz
4 POLES - 1750 RPM

Hst (Pa)
1200

1000

1000
800

900
600
800
400 710
560
630
500
200 450
400
355

0 2 4 6 8 10 12 14 16 18
Air Flow (M3/S)

6 POLES - 1150 RPM

Hst (Pa)
350

300

250
800
200
710
150
630
100 560
500
450
50

0 1 2 3 4 5 6 7 8
Air Flow (M3/S)

6 POLES - 1150 RPM


Hst (Pa)
1000
900
800
1400
700
600 1250

500 1120

400
300 1000

200 900

100

0 5 10 15 20 25 30 35 40
Air Flow (M3/S)

*** Shaded portion is the recommended operating range based on the duct velocity consideration (friction loss of 1 Pa/m)