This guide provides instructions for an experienced installer to install and connect the Extron
Cable Cubby 500 and 700 Cable Access Enclosures.
The Cable Cubby units are furniture-mounted enclosures for cable access,
connections, and AC power. Cables that are not in use can be stored out of the
way while remaining connected to the presentation system.

Planning
Check with local and state regulations before starting
the installation:
……Ensure that the planned installation complies with building and electrical codes.
……Ensure that the planned installation complies with the Americans with Disabilities Act or
other accessibility requirements.

Check all parts and equipment before installation:


……Ensure that all parts are present in each kit.
……Ensure that necessary tools and equipment are available for the installation.
Kit Contents
Cable Cubby 500 Cable Cubby 700

Zip Ties V~
12A
MA
X TO
TA
L

125

Cable Cubby 500 Cable Cubby 700i i B Cable Grommet Plate


Connectivity k
Bracket
Cable Cubby 500 and Cable Cubby 500 CCB Cable Cubby 700
500 Cable CubbyHole
700Plugs

Zip Ties 1AAP Frame Plate 2 Module


AC Power
Tweeker
L
TA
X TO
MA
12A
V~
125

#6 Mounting Screws L

and Star Washers Cable Grommet Plate


TA
X TO
MA
12A
V~

i i B
Connectivity k
Bracket
125

Hole iPlugs Cable Grommet Plate


i B
Connectivity k
Bracket
#4-40 Module ScrewsCable Cubby 700
4 8
Cable Cubby 500

Tweeker AAP Frame Plate AC Power Module


Retractor Trim 1
Retractor Pin & Clip 2
#6 Mounting Screws and Screws AC Power Module
Tweeker
and Zip
Star Washers AAP Frame Plate
Ties X TO
TA
L

ws
MA
12A
V~
125

s0
00 Cable
CableCubby
Cubby700
700
#4-40 Module Screws Cable Cubby 500 1
Cable Grommet PlateCable Cubby 700 2
i i B
Connectivity k
Bracket
ews “Show Me” Cable Trim Plate
Hole Plugs
Retractor Trim Retractor Pin & Clip
and Screws
L
TA
X TO

1 2
MA L
12A TA
V~ X TO

Zip Ties
125 MA
12A
V~

Retractor Pin & Clip


125

Retractor Trim
L
TA

AC Power Module
X TO
MA

Tweeker
12A

AAP Frame Plate


V~
125

and Screws Cable


Connectivity Bracket
i ii i B kk Cable GrommetPlate
Grommet Plate
#6 Mounting
Connectivity Screws
B
Bracket Cable Grommet Plate
and Star Washers i i B
Connectivity k
Bracket
Cable Cubby 500 (3) 3/8",
Cable (1) 1/4"
Cubby 700 (6) 3/8", (2) 1/4"
Hole Plugs
#4-40 Module Screws
Tweeker AAP AC
ACPower
PowerModule
Module
Tweeker AAPFrame
FramePlate
Plate
Tweeker 1 trim, 2 screws
AAP Frame Plate AC Power
2 trims, Module
4 screws
s Zip Ties
Retractor Pin & Clip
L
TA

Retractor Trim
X TO
MA

#6 Mounting Screws
12A
V~
125

andand Screws
Star Washers
Cable Grommet Plate
i i B
Connectivity k
Bracket
ws
ws
#4-40 Module
Hole PlugsScrews 1 2
Retractor Retractor
RetractorPin
Pin&&Clip
RetractorTrim
Trim Clip
and
andScrews Retractor Retractor Pin & Clip AC Power Module
Screws Tweeker Trim AAP Frame Plate
and Screws
#6 Mounting Screws 4 8
and Star Washers
1
#4-40 Module Screws
Cable Cubby 500 and 700 • Installation Guide (Continued)
Preparing the Table
Cut a hole in the surface where the enclosure will be installed. Read the following information before making a cut.
Determine the best location for the enclosure.
……Ensure that the location where the Cable Cubby is to be installed is convenient for as many users as possible.
……Ensure that the edge on which the lid opens is oriented correctly.
……Ensure that there is ample space under the table for cables.
……When installing Retractors in the Cable Cubby, ensure that there is enough space for the Retractor assembly under the table
or furniture (see dimensions for the Retractors below).
NOTES:
• To prevent objects from impeding cable retraction, allow at least 3 inches of clearance from the exposed cable side of
the enclosure (see the diagrams below).
• Excess cabling may cause clearance issues. Use zip ties to secure under-table cabling to prevent accidental contact or
entanglement (see Routing and Connecting Cables on page 6).

Table Top
15.2"
(38.6 cm) 8.8" 11.8"
9.0" (22.4 cm) (30.0 cm)
(22.9 cm)

3.0"
(7.6 cm) 23.3" 21.7" 26.9"
(59.2 cm) (55.0 cm) (68.3 cm)
Series/2
29.3"
(74.4 cm)

21.2"
(53.8 cm)

Cu
t-O
ut
Te
30
C

m
ab

pla
te
3.0"
le

for
2.

C
0"

the
(7.6 cm)
u

Series/2 XL Ex
b
Ta

Series/2 tro
b
ble

n
C
la
m

50
p

(14 5.7 S
(1

5. 0

CU URF
4.

75 cm

.60 5"
6

" )

T cm
AR T-O ACE
Lip rim 0.2
+ WidRing 5" ) 30
EA UT
th
0. 02
00 (0
0.

” .0

P P
(0 5

ag ri n
.0 c
0 m
cm )

e nt ot Series/2 XL
)

S S Sh
iz ca r
D

e: l in
o
1. R gr su he w all d ni

11 1 k
2. ( e k ure st ck pe

C em y) re po er d. e g.

" :1
o o fr th s e
n v o e it t

x
e
fi e m c io h
3. M ur be e c th

rm t

17
4. f il bl ut

M ar it in he o

th e e tou on ab

"
a t

e su te t th le
h th u n C

p rf m an e C

Choose a method for cutting the hole in the table.


ro a p d
5.

w ou c

d ce la t
u c te e
D en

ct u . m
th

to t-o
U

b ut
se

h e im n
(0

e a
0. cm
.6

in r
25 )
r

35

st ea
" R
A

al
e
e

le
cc

d
.
es

ATTENTION: The opening in the table for the Cable Cubby should be cut only by licensed and bonded craftspeople.
la
n
si

t e.
s

u
n

b
Tr o

b
im no
(D

y
an
R tc

50
d
in ut
g’ th

0
p
s is

o
O

si

Exercise care to prevent scarring or damaging the furniture.


ut lin

ti
er e.

o
n
E )

,
dg
e

ATTENTION : L’ouverture dans la table pour le Cable Cubby devrait être coupée seulement par des artisans autorisés et
qualifiés. Faites attention à ne pas faire de marques sur le meuble et à ne pas l’endommager. P/N
68
-85
99
-01
Re
v. A

CAUTION: Wear safety glasses when operating power equipment. Failure to comply can result in eye injury.
ATTENTION : Portez des lunettes de sécurité lorsque vous utilisez l’équipement électrique. Ne pas respecter cela peut
conduire à une blessure à l’oeil.

Choose one of the following methods for cutting the hole:


Hand Router and Routing Template Jigsaw and Paper Cut-Out Template CNC Wood Router
Jigsaw If using a CNC wood router or other
precise machinery, use the exact
cut-out dimensions for your model
(see the table below).
Ca
C
ut-t

ble
O
ut
Te

Cu
m

2.0"
pla

bb
te
fo

Ta
y5
r
th

ble
e

Clam
00
E
xtr

p
on
Tri ip

0.2 in
m id
L

+ 0.0
5"
R th
W

0.0 0”
g

2 (0 (0.00
P P o

.05
cm cm)
ag ri n
e t t

)
S S Sh
iz ca r
n
D

e: l in
1. R ra su e w ll dim nin

11 1 k
2. (g e

Cut-out Dimensions
C em y) re po ere d. e g.

" :1
o o fr th s

Cable
n v o e it th

x
e
fi e m c io
3. M rn be c th

rm th

17
4. fu il ble ut

M ark itu in he o

th e e tou on ab

"
a th re ta k e

e su te t th le
p rf m an e C
ro a p d
5. th

w ou c

d ce la te
th u n C

u c te
D en

ct u . m
to t-o
U

b ut
se

h e
s c p

e a
in re
r

sta a
A

e
e

lle
cc

Cubby
d
.
es

p
n

la
sio

Tri
te
s

(D m Ri
u

.
n

o no ng
s

User Access Side


y
an

t cu ’s Ou
50
d

0
p

t thi ter
o
sit

s lin Ed
io

e.) ge
n
,

Model Width Dimension


P
/N
68
-8
59
9-0
1
R
ev.

500 5.75" (14.6 cm) 5.75" (14.6 cm)


A

700 7.125" (18.1 cm) 5.75" (14.6 cm)


Visit www.extron.com for Cable Cubby routing Dimensions and cut-out templates are
template part numbers and instructions. available online at www.extron.com. 500 CCB 5.75” (14.6 cm) 7.125” (18.1 cm)
2
Preparing the Cable Cubby
Step 1 — Assemble the connectivity modules of your choice.
Connectivity modules allow you to populate the Cable Cubby with a combination of AAPs, cable pass-through modules, or
Retractors.
AAP Module
NOTE: After assembling the 3 Secure the AAP plate on the
connectivity brackets, using
module, proceed to “Step 2 — 1 Secure up to two
two of the provided module
single-space AAPs
in the AAP plate. screws.
Install the modules” below.

Connectivity bracket

#4-40 Nut
w/ Captive Washer
2 I
Insert cables through the bottom
of the connectivity bracket.
Connect cables to the AAPs.

Cable Pass-Through Module


NOTE: After assembling the module, proceed to “Step 2 — Install the modules” below.

For Show Me Cables:


3 Snap the included
2
hole plugs into
any unused holes. 1 Attach the Show Me
Cable Trim Plate to the
Insert cables
through the
1 top of the module, using
bottom of the Flip grommet plate the module screws.
2 Secure the connectivity upside down and
grommet plate bracket and into insert Show Me
on the connectivity the holes of the Cables into the 3
bracket using two grommet plate. grommet plate.
of the provided Attach the grommet
module screws. plate to the bottom
of the module, using
the module screws.

Retractor Trim

Secure the Retractor trim


using the provided
mounting screws (2). NOTE:
• Use a screwdriver to secure the Retractor trim with the screws.
• After installing the trim, proceed to “Step 2 — Install the
modules” below to install the power module.
• Retractors are installed after the Cable Cubby is mounted on the
table (see Installing Retractors on page 5).

Step 2 — Install the modules.


Determine where the connectivity modules and power module will be installed
in the Cable Cubby. The modules may be installed at various heights.
NOTE: Ensure that there is enough room above the 2
modules for the Cable Cubby lid to close completely. Use top A
MA
X TO
TA
L

Secure the modules


using the provided
~ 12
5V
12

hole only.
mounting screws and
star washers on the
L

For the power module:


OTA
XT
MA
2A

front and back of


~1
5V
12

the enclosure.
WARNING: Risk of electric shock. To ensure proper
electrical grounding, use at least two of the provided
#6-32 mounting screws with the star washers.
AVERTISSEMENT : Risque de choc électrique.
L
TA
X TO

1
MA
A
~ 12
5V
12

Afin d’assurer une mise à la terre correcte, utilisez un For Show Me Cable Insert the modules
minimum de deux vis de mise à la terre #6-32 et les assemblies, only use the into the Cable Cubby.
top holes of the bracket.
rondelles en étoile fournies.
3
Connecting a Cable Cubby 500 CCB
For Cable Cubby 500 CCB models, follow the instructions below, then proceed to “Mounting the Cable Cubby in the Table.”
The Cable Cubby 500 CCB contains three contact closure buttons to control input selection on Extron switchers and products with
contact closure control ports. Wire the Cable Cubby switches to the control product as shown in the wiring diagram below.

To wire the captive screw connectors:


1. Strip away 3 inches of the outer jacket
from the end of the cable, and
3/16 inch (5 mm) of the inner jacket
from the end of each wire.
2. Secure the wires to the captive screw
connector using an Extron Tweeker
or other small screwdriver. Follow the
wiring diagram at the right.

Momentary switch
(single pole, double throw)
on captive screw terminal

Contact (C)
Ground (G)
Tally output (T)
Tally voltage (+V)
C G T +V
C NO NC Extron Switcher with
Contact Closure Input
and Tally Output

RESISTOR

NOTE: See the table at the right to 1A @ See


4.52 K, 13 K,
24 VDC / Blue note
determine and select the appropriate 125 VAC below
1% 1%

current-limiting resistor, if needed. NOTE: No resistor required for 5 VDC source.

Mounting the Cable Cubby in the Table


Step 1 — Mount the Cable Cubby flush with the table.

1 Remove the plastic strips


and film on the surface of CAUTION: The flanged edges of the top of the
the Cable Cubby. surface enclosure are sharp. These edges are also
soft and may be easily nicked or bent. Exercise
caution when handling the enclosure to prevent
personal injury or damage to the enclosure.
ATTENTION : Les extrémités à brides du haut de la
2 Ensure that the surface du boîtier sont aiguisées. Ces extrémités
side clamps are sont aussi lisses et peuvent facilement être
seated against
the enclosure. coupées ou pliées. Soyez prudents lorsque vous
manipulez le boîtier afin d’éviter de l’endommager
ou de vous blesser.

3 Lower the Cable Cubby into the hole to test the fit.
If necessary, carefully enlarge the opening.

4
Cable Cubby 500 and 700 • Installation Guide (Continued)
Step 2 — Under the table, adjust the side clamps on the enclosure.

NOTE: To lower the side


clamp, turn the lever
down, then press and
hold the locking plate
1
while sliding down the
clamp.

Lever

Locking
1 Rotate the side clamp 2 Slide the clamp all the way 3 Ensure the Cable Cubby plate
outward and ensure that up against the bottom of is firmly seated in the table.
the lever is down. the table. Raise the lever to secure
the Cable Cubby.

Installing Retractors
Follow the steps below to install Retractors. For horizontal or angular Retractor
mounting, see the information at right, then follow the steps below. Horizontal Mounting
CableCable
Release
Release
Assembly
Assembly

3 Secure the clip


on the pin.

Remove two enclosure


Remove screws
two enclosure screws
(one (one
on each side) side)
on each from from
this position.
this position.
1 Insert retractors into Then,Then,
mount the Retractors
mount as shown
the Retractors as shown
the retractor trim. at left.
at left.

See the Cable Retractor Setup Guide, available on the


Extron website, for additional steps.

Angular Mounting
2 Remove the enclosure screws as shown above, then follow
this step:
Insert the pin through the
retractor mounting hole on
the side of the Cable Cubby
and retractor assembly.

4 Secure the locking screw on


each Retractor.
Do not overtighten. The locking
screw only needs to be snug. MoveMove
the cable release assembly upward until until
the cable release assembly upward
the angular mounting
the angular hole hole
mounting is visible. Reinstall
is visible. the the
Reinstall
enclosure screws
enclosure in thisinhole
screws (both(both
this hole sides).
sides).

5
Routing and Connecting Cables

CAUTION:
Risk of Electric Shock.
This equipment must be grounded.
ATTENTION :
Risque de choc électrique.
3 Connect cables to the AV system Cet équipement doit être fixé au sol.
and connect the AC power cord.

NOTE: Ensure that there is no tension on the power cable.

2 Secure cables with zip ties to the rectangular


holes in the rear of the Cable Cubby.

1 For cable pass-through applications, allow at least 36 inches (0.9 m)


of cable loop for each cable.

Installation Checklist
Planning (page 1)
†† Check with local and state regulations before starting the installation.
†† Check all parts and equipment before installation.
Preparing the Table (page 2)
†† Determine the best location for the enclosure.
†† Choose a method for cutting the hole in the table.
Preparing the Cable Cubby (page 3)
†† Choose and assemble a combination of AAP, cable-pass through, and Retractor connectivity to populate
the Cable Cubby.
†† Secure the connectivity modules and power module in the Cable Cubby.
Connecting a Cable Cubby 500 CCB (page 4)
Mounting the Cable Cubby in the Table (page 4)
†† Mount the Cable Cubby flush with the table.
†† Adjust the side clamps.
Installing Retractors (page 5)
Routing and Connecting Cables (page 6)

68-2491-50
Rev. G
08 17
Extron Headquarters Extron Europe Extron Asia Extron Japan Extron China Extron Middle East Extron Australia Extron India
+800.633.9876 Inside USA/Canada Only +800.3987.6673 +65.6383.4400 +81.3.3511.7655 +86.21.3760.1568 +971.4.299.1800 +61.8.8113.6800 1800.3070.3777
Inside Europe Only +65.6383.4664 FAX +81.3.3511.7656 FAX +86.21.3760.1566 FAX +971.4.299.1880 FAX +61.8.8351.2511 FAX (Inside India Only)
Extron USA - West Extron USA - East
+1.714.491.1500 +1.919.850.1000 +31.33.453.4040 +91.80.3055.3777
+1.714.491.1517 FAX +1.919.850.1001 FAX +31.33.453.4050 FAX +91.80.3055.3737 FAX

© 2017 Extron Electronics All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com
6

Вам также может понравиться