363 SPINDLE_LOAD_BAR_LIM2
decimal Activate utilization display for the spindle, limit value 2 immediately 2/2
100 0 9999999 INTEGER
364 SPINDLE_LOAD_BAR_LIM3
decimal Activate utilization display for the spindle, limit value 3 immediately 2/2
100 0 9999999 INTEGER
365 SPINDLE_LOAD_BAR_MAX
decimal Utilization display for the spindle, maximum immediately 2/2
120 0 120 INTEGER
366 SPINDLE_LOAD_BAR_COL1
decimal Utilization display color for the spindle, range 1 immediately 3/3
10 0 15 Byte
367 SPINDLE_LOAD_BAR_COL2
decimal Utilization display color for the spindle, range 2 immediately 3/3
9 0 15 Byte
368 SPINDLE_LOAD_BAR_COL3
decimal Utilization display color for the spindle, range 3 immediately 3/3
9 0 15 Byte
369 PROBE_MODE
decimal Measuring system type: 1: Probe, 2: Opt. measuring technique immediately 3/3
1 0 2 INTEGER
370 TOOL_REF_PROBE_AXIS1
decimal Absolute position of probe X immediately 2/2
0 999999.999 999999.999 DOUBLE
371 TOOL_REF_PROBE_AXIS2
decimal Absolute position of probe Y immediately 2/2
0 999999.999 999999.999 DOUBLE
372 TOOL_REF_PROBE_AXIS3
decimal Absolute position of probe Z immediately 2/2
9 999999.999 999999.999 DOUBLE
373 MEAS_SAVE_POS_LENGTH2
decimal Activate tool gauging; select Save Pos softkey for all values immediately 2/2
0 0 1 Byte
374 TOOL_WEAR_LIMIT_VALUE
decimal Limit value for wear control during input immediately 2/2
9.999 0 9.999 DOUBLE
375 USER_CLASS_READ_CUS_DIR
decimal Protection level for Read user cycles immediately 2/3
0 7 0 7 Byte
376 USER_CLASS_WRITE_CUS_DIR
decimal Protection level for Write user cycles immediately 2/2
0 2 0 7 Byte