Вы находитесь на странице: 1из 17

MAIN PAGE NEXT

CHAPTER 10

SUPPORTS FOR ROAD SIGNS

DRAWING TITLE DRAWING NO. REVISION

SUPPORT FOR DIRECTIONAL AND INFORMATION SIGNS


(SHEET 1 OF 3) LTA/SDRE14/10/SUP1 B

SUPPORT FOR DIRECTIONAL AND INFORMATION SIGNS


(SHEET 2 OF 3) LTA/SDRE14/10/SUP2 A

SUPPORT FOR DIRECTIONAL AND INFORMATION SIGNS


(SHEET 3 OF 3) LTA/SDRE14/10/SUP3 -

SUPPORT FOR TRAFFIC SIGN (SHEET 1 OF 4) LTA/SDRE14/10/SUP4 A

SUPPORT FOR TRAFFIC SIGN (SHEET 2 OF 4) LTA/SDRE14/10/SUP5 A

SUPPORT FOR TRAFFIC SIGN (SHEET 3 OF 4) LTA/SDRE14/10/SUP6 B

SUPPORT FOR TRAFFIC SIGN (SHEET 4 OF 4) LTA/SDRE14/10/SUP7 -

ROAD GANTRY TRUSS (SHEET 1 OF 2) LTA/SDRE14/10/SUP8 A

ROAD GANTRY TRUSS (SHEET 2 OF 2) LTA/SDRE14/10/SUP9 A

ROAD GANTRY SIGN LTA/SDRE14/10/SUP10 -

SUPPORT FOR CANTILEVER DIRECTIONAL SIGNS


(SHEET 1 OF 3) LTA/SDRE14/10/SUP11 A

SUPPORT FOR CANTILEVER DIRECTIONAL SIGNS


(SHEET 2 OF 3) LTA/SDRE14/10/SUP12 -
PREVIOUS

CHAPTER 10

SUPPORTS FOR ROAD SIGNS

DRAWING TITLE DRAWING NO. REVISION

SUPPORT FOR CANTILEVER DIRECTIONAL SIGNS


(SHEET 3 OF 3) LTA/SDRE14/10/SUP13 A

TYPICAL STEEL BRACKETS FOR 4.5m HEIGHT LIMIT SIGN


(900mm X 900mm) LTA/SDRE14/10/SUP14 -

SUPPORT FOR TRAFFIC SIGN (FOR ARTERIAL & EXPRESSWAY) LTA/SDRE14/10/SUP15 -


NEXT
NEXT
CHAPTER 10 - MAIN PAGE
DETAIL FOR DIFFERENT TYPE OF SUPPORTS (FOR DETAILS, SEE LTA/SDRE14/10/SUP2 & 3)
W = 5000 (MAXIMUM) (NTS)

MAXIMUM AREA OF SIGNBOARD POST SIZE FOOTING SIZE BASE PLATE SIZE DIAMETER OF BOLT
SUPPORT HD BOLT ANCHORAGE FIN PLATE
TYPE SHS L B D L X B X THK (GRADE 8.8) LENGTH SIZE
AREA, (m² ) = W X H
(mm) (mm) (mm) (mm) (mm) FOR BASE PLATE (mm) (mm)

DIA 75 G.I. PIPE


A AREA ≤ 1.54 450 450 750 200 X 200 X 10 - - 150 X 50 X 8
3.2 THK

B 1.54 < AREA ≤ 10 100 X 100 X 6 1650 800 300 250 X 250 X 12.5 16 600 100 X 75 X 10

C 10 < AREA < 20 120 X 120 X 8 2300 800 400 300 X 300 X 15 20 650 150 X 75 X 12.5

D 20 < AREA ≤ 27.5 150 X 150 X 6 2600 800 500 350 X 350 X 15 24 700 200 X 75 X 15

M AXI
H = 5500 ( NTS)
M UM )(
100 100

M UM )
90
R

M AXI
1
SDRE14/10/SUP3

H = 858 (
400

W = 1800 (MAXIMUM)

2400
2400
MINIMUM 1000
MINIMUM 1000
50

L
A B
- -

500
D
150

STUMP 500 X 500 STUMP


M.S. FIN PLATE
50 WELDED TO POST

M.S. BASE PLATE

D
100

WELDED TO POST
B
L

M.S. BASE PLATE 50 THK LEAN CONCRETE

150 THK HARDCORE

B B B

SECTION A-A SUPPORT TYPE A SECTION B-B SUPPORT TYPE B, C & D

NOTES: 7. All structural steel work shall be hot-dipped galvanised to 125 microns
1. The concrete shall be of C25/30. before one coat epoxy based primer and two coats of epoxy paint of
2. The minimum concrete cover to all reinforcement shall be 35mm. approved color (International Paint Intergard EAA001/EAA002 or STANDARD DETAIL
3. The minimum soil bearing capacity shall be 75 kPa. equivalent) are applied.
4. Yield strength of galvanised iron pipes as specified in SS EN 10255:2013 8. All bolts strength grade used are as specified in BS 4190 GRADE 8.8
shall be 195N/mm². unless noted otherwise.
5. Fabrication and erection of steel structure shall be in accordance with 9. All welding shall be 6mm continuous fillet weld. SUPPORT FOR DIRECTIONAL DRAWING NO. REV.
BS EN 1, SS EN 1993, BS EN 1090, SS EN 1994. 10. The rigidity of a sign plate may be improved by forming a flange around AND INFORMATION SIGNS LTA/SDRE14/10/SUP1 B
6. All structural steel sections shall be in accordance with BS EN 10025, its perimeter. The flange must be provided along all edges and be B SEP 2017 (SHEET 1 OF 3)
folded at right angles to the sign face and to a depth not less than 25mm. A OCT 2015 DATE OF ISSUE SCALE SHEET NO.
BS 7668, BS EN 10029 AND BS EN 10210-1.
(To be continued at sheet 2 of 3) REV. DATE 1st APR 2014 1:25 1 OF 3

10-1
CHAPTER 10 - MAIN PAGE PREVIOUS NEXT

A
-
1 75 DIA X 3.2 THK G.I. ELBOW
2
SDRE14/10/SUP3 JOINED TO G.I. PIPE BY SINGLE V
FULL STRENGTH BUTT WELD SDRE14/10/SUP3 2
6 THK M.S. BRACKET BUTT SHS TO BE SEALED WITH
M.S. EYELET TO BE SDRE14/10/SUP3
WELDED TO POST ON 5 THK M.S. PLATE ON TOP
WELDED TO G.I. PIPE COUNTER SUNK
RIVETS AT 150 PERIMETER TO SUPPORT SIGN
(TYP.) 10 DIA BOLT
C/C STAGGERED

100
5 THK CIRCULAR END
PLATE WELDED TO END
OF G.I. PIPE 75 X 75 X 6 BRACKET BUTT

200
WELDED TO POST ON 3 SIDES
75 X 38 X 3 RHS TO SUPPORT STIFFENERS OF SIGN

SIGN

200
3
SDRE14/10/SUP3 COUNTER SUNK
BUTT JOINT BACKING RIVETS 5
SDRE14/10/SUP3
4
SDRE14/10/SUP3
ALUMINIUM SHEETING 14SWG. LAMINATED ON 75 X 38 X 3 RHS
ONE SIDE / BOTH SIDES WITH HIGH INTENSITY
/ DIAMOND GRADE REFLECTIVE SHEETING
75 X 38 X 3 RHS

M UM
SIGNBOARD TYPE A 4

700 M AXI
6

200
SCALE 1:25 SDRE14/10/SUP3 SDRE14/10/SUP3

2 X 10 DIA BOLT
)
TYP.

B 6 THK M.S. BRACKET BUTT


ALUMINIUM BACKING WELDED TO POST ALONG
50 (

50 (TYP.)
PIECE TO BE USED PERIMETER TO SUPPORT SIGN
HD BOLT WITH ALUMINIUM
WASHER & NUT SHEETING

100
L

NO. 14 SWG
6 THK FILLET WELD ALL ROUND

1000 (MAXIMUM) B
75 FIN PLATE WELDED TO
-
M.S. BASE PLATE BASE PLATE AND SHS
2400

SECTION B-B
NON-SHRINK GROUT
SUPPORT POST
SCALE 1:25

100
25 THK CEMENT GROUT

25
NKS
BOLT

T10-
200
8T13

LI
ANCHORAGE
C
LENGTH
-

400
DETAIL AS RHS
4 NOS.
3T13
100 X 100 X 6
THK ANGLE WELDED
T10-200 LINKS
2T13 TO FORM A SQUARE T13-200 T&B
BOTHWAY
STUMP
3T13 REAR VIEW OF SIGNBOARD TYPE B, C & D
SECTION A-A
SCALE 1:50
SCALE 1:50

SECTION C-C
SCALE 1:25

NOTES:(Continued) STANDARD DETAIL


11. Backing is required when the sign is made up of separate sheets.
12. Further stiffening can be effected by reinforcing the flange with
25mm x 25mm x 3mm thick angles.
13. The position of signboard shall not be obstructed and shall be determined on site. SUPPORT FOR DIRECTIONAL DRAWING NO. REV.
14. All circular hollow section pipe sizes shown are normal. AND INFORMATION SIGN LTA/SDRE14/10/SUP2 A
15. All rectangular hollow section and square hollow section sizes shown are (SHEET 2 OF 3)
DATE OF ISSUE SCALE SHEET NO.
external dimensions. A SEP 2017

REV. DATE 1st APR 2014 AS SHOWN 2 OF 3

10-2
CHAPTER 10 - MAIN PAGE PREVIOUS NEXT

6 DIA
M.S. BOLT
& NUT

28
4.
5

18
5 THK CAPPING PLATE

ON
EXTENSI
6 THK M.S. PLATE
WELDED ALL ROUND

18
5
.
18 37
5
.
EXISTING CAPPING 37
PLATE TO REMAIN

ISOMETRIC VIEW OF DETAIL 1


FULL PENETRATION
EYELET FOR SUPPORT TYPE A ISOMETRIC VIEW OF DETAIL 2 ISOMETRIC VIEW OF DETAIL 3 BUTT WELD ALL 50

REF DWG NO: SDRE14/10/SUP1 & 2 REF DWG NO: SDRE14/10/SUP2 REF DWG NO: SDRE14/10/SUP2 ROUND
SCALE 1:2 SCALE 1:10 SCALE 1:10
EXISTING POST

TYPICAL SPLICING DETAIL FOR


EXTENSION OF POSTS FOR ADDITIONAL SIGNBOARD
(FOR SUPPORT TYPES B, C, D & E ONLY)
38
75
NOTES:
1. The total area of the signboard shall not

100
exceed the maximum for the support.
(See table in Dwg No: LTA/SDRE14/SUP/1)
10
0 2. The height (h) of signboard shall not
exceed 5.5m, including whatever signboard
2 NOS. 10 DIA BOLT which is subsequently added.
2 NOS. 10 DIA BOLT

6 THK M.S. BRACKET


BUTT WELDED TO
100

COUNTER SUNK RIVET


HORIZONTAL MEMBER

ISOMETRIC VIEW OF DETAIL 4 DETAIL 5 ISOMETRIC VIEW OF DETAIL 6


REF DWG NO: SDRE14/10/SUP2 REF DWG NO: SDRE14/10/SUP2 REF DWG NO: SDRE14/10/SUP2
SCALE 1:10 SCALE 1:1 SCALE 1:10

STANDARD DETAIL

SUPPORT FOR DIRECTIONAL DRAWING NO. REV.


AND INFORMATION SIGN LTA/SDRE14/10/SUP3 -
(SHEET 3 OF 3)
DATE OF ISSUE SCALE SHEET NO.

REV. DATE 1st APR 2014 AS SHOWN 3 OF 3

10-3
CHAPTER 10 - MAIN PAGE PREVIOUS NEXT

1000 (MAXIMUM)

R50
ALUMINIUM FLAT
50 X 3 THK
AS STIFFENER

M UM )
350 800 350

M AXI

50
900 (
R50

400
4.8 DIA POP RIVETS
-
(3 NOS)

50
TRAFFIC SIGN
TRAFFIC SIGN (3 THK ALUMINIUM FLAT
(3 THK ALUMINIUM SHEET) 50 X 3 THK
4.8 DIA RIVETS
ALUMINIUM SHEET) APPROVED 25 WIDE
(MINIMUM 3 NOS. & AS STIFFENER
(1.1 THK MINIMUM)
NOT MORE THAN

ES FROM 500 -1200


VERY HIGH BOND
150mm APART) SHS
DOUBLE COATED
1 50 X 50 X 2.3 THK HOT DIPPED ACRYLIC FOAM TAPE
SDRE14/10/SUP6 GALVANISED SQUARE HOLLOW SECTION

1
50 X 50 X 2.3 THK CEMENT MORTAR
CEMENT MORTAR SDRE14/10/SUP6 TRAFFIC SIGN
HOT DIPPED GALVANISED 300 X 300 X 75
GHT VARI

300 X 300 X 75
SQUARE HOLLOW SECTION (ON FOOTPATH) 4.8 DIA RIVETS
(ON FOOTPATH)
400 X 400 X 75 ALUMINIUM FLAT
400 X 400 X 75
(ON FOUNDATION) 50 X 3 THK STIFFENER
HEI

(ON FOUNDATION)

SECTION A-A
REF DWG NO: SDRE14/10/SUP6
SCALE 1:2

400 X 400 X 400


GRADE 20 CONCRETE

SINGLE POST SUPPORT DOUBLE POST SUPPORT


SCALE 1:10 SCALE 1:10

NOTES: STANDARD DETAIL


1. Minimum height clearance:
- 900mm - 1200mm - sharp deviation barrier traffic sign
- 500mm - Keep Left / Right Pass Either Side traffic sign
2. Stiffener to use approved 25mm (1.1mm thk minimum) very high bond double SUPPORT FOR DRAWING NO. REV.
coated acrylic foam tape firmly bonded to traffic sign. TRAFFIC SIGN LTA/SDRE14/10/SUP4 A
(SHEET 1 OF 4)
A OCT 2015 DATE OF ISSUE SCALE SHEET NO.

REV. DATE 1st APR 2014 AS SHOWN 1 OF 4

10-4
CHAPTER 10 - MAIN PAGE PREVIOUS NEXT

60 60

TRAFFIC SIGN TRAFFIC SIGN

TRAFFIC SIGN

TRAFFIC SIGN HOLDER


REFER TO ISOMETRIC
19 WIDTH STAINLESS
VIEW
STEEL BAND WITH BUCKLE
SECURED AROUND LAMP

25

25
POST OR VERTICAL
SUPPORT

19
600 & BELOW
4.8 DIA RIVETS
LAMP POST OR
VERTICAL SUPPORT

2400
4.8 DIA RIVETS
(3 NOS)

600 600
25 X 20 X 6 THK
ALUMINIUM FLAT BAR WELDED
GROUND LEVEL TO 250 X 25 X 6
THK ON 450 X 25 X 6 THK

25
FLAT BAR ALUMINIUM

250 X 25 X 6 THK
ALUMINIUM FLAT BAR

900
TRAFFIC SIGN ON VERTICAL SUPPORT
SCALE 1:20

25
450 X 25 X 6 THK
ALUMINIUM FLAT BAR

LAMP POST OR
VERTICAL SUPPORT
25

FULL WELD
GN)
GN)

25
FOR 600 SI
FOR 900 SI

25 X 6 THK ALUMINIUM FLAT BAR


FABRICATED AT RIGHT ANGLES AND
WELDED TO 250 X 25 X 6 THK OR
250 (
450 (

450 X 25 X 6 THK ALUMINIUM FLAT BAR

250 X 25 X 6 THK OR
450 X 25 X 6 THK ALUMINIUM FLAT BAR
25

FULL WELD

ISOMETRIC VIEW TRAFFIC SIGN HOLDER TYPE 1


SCALE 1:5 SCALE 1:5

STANDARD DETAIL

SUPPORT FOR DRAWING NO. REV.


TRAFFIC SIGN LTA/SDRE14/10/SUP5 A
(SHEET 2 OF 4)
A SEP 2017 DATE OF ISSUE SCALE SHEET NO.

REV. DATE 1st APR 2014 AS SHOWN 2 OF 4

10-5
CHAPTER 10 - MAIN PAGE PREVIOUS NEXT
900 (MAXIMUM)

50
SHS (WITHOUT HAND
CUT FACE) TO BE SEALED
WITH RIGHT SIZE
RUBBER PLUG ON TOP

TRAFFIC SIGN TRAFFIC SIGN

M UM )
1100 - 1700

M AXI
SHS (WITHOUT HAND CUT FACE)
4.8 DIA RIVETS (NOT 4.8 DIA RIVETS (NOT
TO BE SEALED WITH RIGHT SIZE

1000 (
MORE THAN 150 APART) MORE THAN 150 APART)
RUBBER PLUG ON TOP

50
50 A
SDRE14/10/SUP4

4.8 DIA RIVETS


(NOT MORE THAN
150 APART)
ES
VARI

50
SDRE14/10/SUP4

50
50 X 50 X 2.3 THK HOT DIPPED GALVANISED
SQUARE HOLLOW SECTION (SHS)
TRAFFIC SIGN ALUMINIUM FLAT
50 X 3 THK
AS STIFFENER

800

2400
SIDE ELEVATION
50 X 50 X 2.3 THK SCALE 1:10
HOT DIPPED GALVANISED
SQUARE HOLLOW SECTION EXPANSION BOLTS HOLE
200 X 200 X 10 THK
CEMENT MORTAR M.S. PLATE WELDED TO SHS 200 X 200 X 10 THK M.S. PLATE
2400

1 300 X 300 X 75
(ON FOOTPATH)
- 400 X 400 X 75

40
(ON FOUNDATION)
CEMENT MORTAR
300 X 300 X 75 (ON FOOTPATH)
75
450 X 450 X 75 (ON FOUNDATION) 40

200
SHS

4 NOS. EXPANSION BOLTS


FULL WELD

400 X 400 X 600


C16/20 CONCRETE

200
450 X 450 X 600
DOUBLE POST SUPPORT C16/20 CONCRETE
PLAN
VERTICAL SUPPORTS FOR TRAFFIC SIGN
2
DETAIL 1
WITH AREA NOT EXCEEDING 1.35m SINGLE POST SUPPORT
REF DWG NO: SDRE14/10/SUP4
SCALE 1:20 SCALE 1:10 SCALE 1:5

STANDARD DETAIL

SUPPORT FOR DRAWING NO. REV.


TRAFFIC SIGN LTA/SDRE14/10/SUP6 B
B SEP 2017 (SHEET 3 OF 4)
OCT 2015 DATE OF ISSUE SCALE SHEET NO.
A

REV. DATE 1st APR 2014 AS SHOWN 3 OF 4

10-6
CHAPTER 10 - MAIN PAGE PREVIOUS NEXT
NOTES:
1. The notes are applicable for support for traffic sign.
2. The dimension of the galvanised Square Hollow Section (SHS) shall
be 50mm x 50mm and measured externally (unless otherwise
specified). Its wall thickness shall be 2.3mm.
3. Square Hollow Section (SHS) shall comply with ASTM A500-74a and
shall be hot-dip galvanised according to BS EN ISO 1461.
4. Rivet used shall be of minimum diameter of 4.8mm.
5. Bolt and nut used must be approved stainless steel and of the
round head type.
6. A minimum of two numbers of rivets or bolts are required per
600 X 600 OR traffic sign.
600 X 450 7. Expansion bolt used shall comply with the followings :
TRAFFIC SIGN
a) Anchor/hole diameter : 15mm (minimum)
b) Anchor length/hole depth : 50mm (minimum)
25 X 25 X 2 THK c) Thread length/depth : 18mm (minimum)
ALUMINIUM SQUARE HOLLOW
d) Internal thread size : 12mm (minimum)
SECTION (SHS)
8. Welding must be continuous and all round.
9. In general, traffic signs are to comprise of 2mm thick aluminum sheets.
LAMP POST OR However, 3mm thick aluminium sheets must be used for the following
VERTICAL SUPPORT
signs:
2 NOS. 50 X 20 X 6 THK a) Traffic signs of size 900mm x 900mm.

10
ALUMINIUM FLAT BAR WELDED b) 'Directional Arrows' signs of size 600mm x 150mm.
TO 250 X 50 X 6 THK
c) Signs erected at height clearance less than 2.2m such as 'Sharp

20
ALUMINIUM FLAT BAR 600 X 150 TRAFFIC SIGN WITH
PROPOSED Deviation', 'Keep Left / Right' and 'Pass Either Side' or
4.8 DIA RIVETS (AS REQUIRED)
25 X 25 d) Street name board installed on walls or bus shelters.
STIFFENER 10. Approved 25mm wide (1.1mm thick minimum) very highly bonded double
2 NOS. 19 WIDTH STAINLESS FULL WELD coated acrylic foam tape is required for all traffic signs of 3mm
STEEL BAND WITH BUCKLE 40 thick aluminum sheets, and or signs with area 1 sq. metre.

20
SECURED AROUND LAMP 600 X 600 OR 11. Stainless steel band used must be approved with minimum thickness
POST OR VERTICAL SUPPORT 600 X 450 TRAFFIC SIGN
of 0.76mm.
12. Appropriate sized aluminum flats shall act as wedge between the
450 traffic sign and lamp post such as to maintain true verticality of
the sign.
(REDUCE TO 100mm IF TRAFFIC
SIGN CAN CLEAR TOP OF
VERTICAL SUPPORT)

TRAFFIC SIGN HOLDER TYPE 2


SCALE 1:10

25 X 25 X 2 THK 7.9 DIA HOLE FOR HIGH


ALUMINIUM SQUARE HOLLOW TENSILE THREADED STUD
SECTION (SHS)
6 THK ALUMINIUM PLAIN PLATE

10
WALL

150
600 X 150 TRAFFIC SIGN
PROPOSED HOLDER TYPE 2
TRAFFIC SIGN
25 X 25
(AS REQUIRED)
STIFFENER

20
FULL WELD

20
150

450

DETAILS OF WALL PLATE TRAFFIC SIGN


SCALE 1:5
TRAFFIC SIGN ON WALL
SCALE 1:10

STANDARD DETAIL

SUPPORT FOR DRAWING NO. REV.


TRAFFIC SIGN LTA/SDRE14/10/SUP7 -
(SHEET 4 OF 4)
DATE OF ISSUE SCALE SHEET NO.

REV. DATE 1st APR 2014 AS SHOWN 4 OF 4

10-7
CHAPTER 10 - MAIN PAGE PREVIOUS NEXT

1
2 A
SDRE14/10/SUP9
SDRE14/10/SUP9 SDRE14/10/SUP9

CENTRE-LINE OF SPLICE

1600
2500
0.3L 0.3L

(LANE WIDTH) (LANE WIDTH) (LANE WIDTH) (LANE WIDTH) (LANE WIDTH)

50

OVERHEAD
APPLICABLE ONLY TO LOW-OVERHEAD

NED ON
STRUCTURES WITH HEADROOM
CLEARANCE IS LESS THAN OR

5700
EQUAL TO 4.8m

TO BE DETERM I
TE FOR LOW -
STRUCTURE)
SI
(
TYPICAL LAYOUT OF TRUSS

2
SDRE14/10/SUP9

CENTRE-LINE OF SPLICE

1600
2500

0.3L

(LANE WIDTH) (LANE WIDTH) (LANE WIDTH) (LANE WIDTH) (LANE WIDTH)

50
APPLICABLE ONLY TO LOW-OVERHEAD
STRUCTURES WITH HEADROOM
OVERHEAD

CLEARANCE IS LESS THAN OR


NED ON

EQUAL TO 4.8m
5700

TO BE DETERM I
TE FOR LOW -
STRUCTURE)
SI
(

ALTERNATIVE ARRANGEMENT OF N-TRUSS


FOR OTHER SPANS OF GANTRY

NOTES: 5. All cut edges shall be dressed to a neat workmanlike finish and shall be
1. Fabrication of all structural steel work shall be carried out in accordance with free from distortions. STANDARD DETAIL
SS EN 1993, BS EN 1090, SS EN 1994. All steel work shall be fabricated 6. All welding shall be in accordance with BS EN 1011 & electrodes to
from new sections and in such manner that they are bent, twisted or damaged. BS EN ISO 2560:2005
2. Fabrication of all structural steel work including welding, trimming & painting shall be7. No site welding shall be allowed unless approved by the S.O.
inspected and approved by the S.O. 8. Bolts and locking nuts shall comply with BS 4933. DRAWING NO. REV.
ROAD GANTRY TRUSS
3. The material for all structural steel work shall comply with BS EN 10025, BS 7668, 9. All bolts shall be fitted with washers & locking nuts complying with BS 4320.
(SHEET 1 OF 2) LTA/SDRE14/10/SUP8 A
BS EN 10029 AND BS EN 10210-1. Nut shall be of at least the strength grade appropriate to the grade of bolt
4. All steel sections shall be hot-dipped galvanised and two coats of compatible paints A OCT 2015 DATE OF ISSUE SCALE SHEET NO.
used.
shall be applied to all damaged surfaces. (To be continued at sheet 2 of 2) REV. DATE 1st APR 2014 1:100 1 OF 2

10-8
CHAPTER 10 - MAIN PAGE PREVIOUS NEXT

CHS

RHS

2500

10 THK CIRCULAR
PACKER PIECE INSIDE

2 NOS. 40 X 40 X 6 THK
M.S. PLATE WELDED TO RHS
1400 1400 (MAXIMUM) CHS

50 DIA G.I. PIPE


APPLICABLE ONLY TO LOW
CENTRE-LINE OF SPLICE OVERHEAD STRUCTURE

SINGLE V FULL
STRENGTH BUTT WELD
RHS

DETAIL 2 3 2 NOS. 40 X 40 X 6 THK


M.S. PLATE WELDED TO R.H.S.

200
-
DETAIL 1 COLUMN / TOPCHORD SPLICE DETAIL
8 DIA G.I. CHAIN
REF DWG NO: SDRE14/10/SUP8 REF DWG NO: SDRE14/10/SUP8
SCALE 1:50 SCALE 1:10 50 DIA WITH 3 THK
G.I. PIPE WRAPPED WITH RED
& WHITE REFLECTED SHEETING
10 THK 'U' BAR WELDED TO G.I. PIPE

SECTION A-A (CHAIN TYPE)

REINFORCED CONCRETE FOUNDATION FOR LOW-OVERHEAD STRUCTURES (4.8m AND BELOW)


SCALE 1:20

RHS

10 DIA BOLT 2 NOS. 40 X 40 X 6 THK


(GALVANISED) PLATE WELDED TO R.H.S.

SETTING OUT PLAN OF FOUNDATION

200
SCALE 1:100 8 DIA G.I. CHAIN

50 DIA WITH 3 THK G.I. PIPE


10 THK `U' BAR WELDED
WRAPPED WITH RED & WHITE
NOTES: (Continued) TO G.I. PIPE
REFLECTED SHEETING
17. 75mm lean concrete blinding (C12/15) shall be provided under the footing.
10. All gantry steel members such as columns, truss members, base plates and
18. Concrete shall be of strength class C28/35. DETAIL 3
stiffener plates, etc are to be at least grade S275.
19. For gantry over carriageway (wholly span or cantilever), the supports shall SCALE 1:10
11. Stainless steel holding down bolts shall conform to BS EN ISO 3506 Grade A4-80.
be designed to comply with the requirement in BD 51/98. When checking
12. Aluminum sign board shall be attached to frame with aluminum head fixing bolt of
against the sliding and bearing capacity of the gantry foundations, even
an approved type and a rubber setting of 3mm thickness be used between all the
for piled foundations, the collision loads shall be reduced by 50% but full
contact area of the aluminum signboard and the frame.
loading shall be considered for checking against overturning in accordance STANDARD DETAIL
13. The top of the concrete footing shall be at a depth of 500mm below the final
with BD 60/04.
ground level.
20. Gantries shall not be located less than two times their maximum height
14. Subgrade below the concrete footing shall be compacted to at least 95% off the
clear of any overhead bridge.
maximum dry density and minimum bearing capacity of soil directly under the
DRAWING NO. REV.
footing shall be 150KN/m². ROAD GANTRY TRUSS
(SHEET 2 OF 2) LTA/SDRE14/10/SUP9 A
15. Section B-B applicable to low-overhead structure of 4.8m and below.
16. Minimum concrete cover to nearest reinforcement shall be 50mm for the footing A OCT 2015 DATE OF ISSUE SCALE SHEET NO.

and stump. REV. DATE 1st APR 2014 AS SHOWN 2 OF 2

10-9
CHAPTER 10 - MAIN PAGE PREVIOUS NEXT

1400
1400 (MAXIMUM) 1400 (MAXIMUM) (MAXIMUM)

CHS 25 X 25 X 3 SHS

200
SIGNBOARD
SIGNBOARD

5
401.
75

200

200
75
TO BE CUT FROM
25 X 25 X 3 SHS
125 X 75 X 5 RHS

THIS END TO 75 50 X 25 X 3 RHS


BE SEALED UP FRAME
TRUSS
50 X 25 X 3 RHS
1800

1400

1400
1000
1

1600
-
150 X 100 X 6 RHS
50 X 25 X 3 RHS
50 X 25 X 3 RHS

THIS END TO
BE SEALED UP

75
200

200
75
75

5
398.
200

25 X 25 X 3 SHS 6 NOS. OF 8 DIA STAINLESS STEEL


BOLTS AND NUTS OF MINIMUM LENGTH
A
45 PER PANEL OF SIGNBOARD.
RHS -
SECTION A-A
DETAIL OF FRAME FOR SIGNBOARD
STAINLESS STEEL SCALE 1:20
SCALE 1:20
CONNECTION DETAILS OF SIGNBOARD TO TRUSS 8 DIA BOLTS
& NUTS WITH 2 NOS.
SCALE 1:20 18 DIA WASHERS

DETAIL 1
1400 (MAXIMUM) NOT TO SCALE
50 X 25 X 3 RHS 25 X 25 X 3 SHS SIGNBOARD
200

10 DIA BOLT WITH


22 DIA WASHER 3 THK
1800

1400

50 x 25 x 3 RHS

50 x 25 x 3 RHS
200

37.5
6 NOS. 8mm DIA STAINLESS STEEL
BOLTS AND NUTS OF MINIMUM
150 x 100 x 6 RHS
LENGTH 45 PER PANEL OF SIGNBOARD.

6 75
TYPICAL LAYOUT OF FRAME SUPPORTING SIGNBOARD
SCALE 1:50

CONNECTION DETAILS OF SIGNBOARD TO TRUSS


SCALE 1:10

STANDARD DETAIL

DRAWING NO. REV.


ROAD GANTRY SIGN LTA/SDRE14/10/SUP10 -

DATE OF ISSUE SCALE SHEET NO.

REV. DATE 1st APR 2014 AS SHOWN 1 OF 1

10-10
CHAPTER 10 - MAIN PAGE PREVIOUS NEXT
6 THK M.S. PLATE FILLET 2 THK ALUMINIUM PLATE
WELDED TO SUPPORT SIGN GENERAL NOTES :
TOP HORIZONTAL

400

100
MEMBER 1) Backing is required when the sign board is made 5) The material for all structural steelwork shall
up of separate sheets. comply with BS 7668, BS EN 10025, BS EN 10029 and

M UM )
2) Every section of the signboard shall be bolted BS EN 10210.
6) All steel sections shall be hot-dipped galvanised
and applied with two coats of compatible paint
being applied to all damaged surfaces, except
the stainless steel holding-down bolts.

700
EQ

M AXI
onto the signboard frame using 8mm diameter 6) All steel sections shall be hot-dipped galvanised
(
2 THK ALUMINIUM
PACKING PIECE stainless steel bolts and nuts at 500mm C/C. and applied with two coats of compatible paint
3) Fabrication of all structural steelwork shall being applied to all damaged surfaces, except
M UM )

be carried out in accordance with BS EN 1, the stainless steel holding-down bolts.


200

1 75 X 38 X 3 THK RHS
700
EQ

SS EN 1993, BS EN 1090, SS EN 1994. 7) All cut edges shall be dressed to a neat


M UM ) M AXI
(

- 100 X 100 X 6 SHS All steelwork shall be fabricated from new workmanlike finish and shall be free from distortions.
sections and in such manner that they are not 8) All welding shall be in accordance with BS EN 1011
bent, twisted or damaged. and electrodes to BS EN ISO 2560.
200

2
700
EQ

BOTTOM HORIZONTAL 4) Fabrication of all structural steelwork including 9) No site welding shall be allowed unless
M AXI
(

- 100
MEMBER welding, trimming and painting shall be inspected approved by the S.O.
and approved by the S.0. 10) Ordinary bolts and nuts shall comply with
100

25
400

BS 3692 OR BS 4190, BS 4933.


11) All ordinary bolts shall be fitted with washers
and nuts complying with BS 4320. Nut shall be
700 EQ EQ EQ EQ EQ EQ 700 of at least the strength grade appropriate to

(1025 MAXIMUM) (1025 MAXIMUM) (1025 MAXIMUM) (1025 MAXIMUM) (1025 MAXIMUM) (1025 MAXIMUM) the grade of bolt used.
12) The grade and diameter of bolts shown in column 's' in
the table for directional signs shall be
A strictly adhered for their specific function.
REAR VIEW OF SIGN BOARD
10 DIA BOLT Using higher or lower grade and bigger or
- SCALE 1:50
TOP HORIZONTAL MEMBER smaller diameter of bolts are not acceptable.
1100 l B 13) The bolts strength grades are as specified in
- BS 4190. Grade 4.6 and 8.8 are made of mild steel
INNER EDGE OF SIGN BOARD
3 and high-strength steel with yield stress of
235N/mm² and 627N/mm² respectively.
SDRE14/10/SUP12
100 X 100 X 6 SHS 14) All steel reinforcement bars shall conform to
75 X 38 X 3 THK RHS SS 560. All welded steel fabric reinforcement shall
6 THK M.S. BRACKET FILLET
WELDED TO conform to SS 561.
100 X 100 X 6 SHS ALONG 15) Stainless steel holding-down bolts comforming to

h
PERIMETER TO SUPPORT SIGN 10 DIA BOLT BS EN ISO 3506 Grade A4-80 shall provided to connect
the steel post base plate with the anchorages in
the 800mm x 800mm stump.
75 X 75 X 6 THK ANGLE
4 MS BRACKET WELDED TO
16) Minimum concrete cover to nearest reinforcement

SDRE14/10/SUP12 100 X 100 X 6 SHS ON shall be 50mm for the footing & stump.
75 X 75 X 6 THK ANGLE 3 SIDES TO SUPPORT SIGN 17) 75mm lean concrete blinding (C12/15) shall be
M.S. BRACKET WELDED TO
400

2 THK ALUMINIUM PACKING PIECE provided under the footing.


ADDITIONAL MEMBER FOR 100 X 100 X 6 SHS ON 3
18) Concrete shall be of strength class C28/35.
5 TYPE `4', `5', `10' AND `11' ONLY SIDES TO SUPPORT SIGN
DETAIL 1 SECTION B-B 19) Subgrade below the concrete footing shall be
SDRE14/10/SUP12
100 X 100 X 6 SHS compacted to at least 95% of the maximum dry density
(a) 100 X 100 X 6 SHS SCALE 1:20 SCALE 1:20
WELDED TO TOP & and minimum bearing capacity of soil directly under
75 X 38 X 3 THK RHS the footing shall be 130KN/m².
BOTTOM HORIZONTAL
5700

MEMBERS C
-

2 NOS. 10 DIA BOLT

100 X 100 X 6 SHS


1250 900 2750 3700
2 NOS. 10 DIA BOLT
EXPRESSWAY EXPRESSWAY
1050

SHOULDER OUTER LANE 6 THK MS BRACKET WELDED


TO 100 X 100 X 6 SHS
ALONG PERIMETER TO
SUPPORT SIGN

2 THK ALUMINIUM DETAIL 2 SECTION C-C


PLATE
SCALE 1:20 SCALE 1:20
FOUNDATION
BOTTOM HORIZONTAL MEMBER
The dimension of the components in the drawings shall be taken as the minimum size required.
ELEVATION OF DIRECTIONAL SIGN ALONG EXPRESSWAY The bolts shown in column 's' shall be strictly followed as highlighted in drawing note no 12.
SECTION A-A
The specified structural strength of the components shall be checked by professional engineer.
SCALE 1:100
SCALE 1:20

STANDARD DETAIL

SUPPORT FOR CANTILEVER DRAWING NO. REV.


DIRECTIONAL SIGNS LTA/SDRE14/10/SUP11 A
(SHEET 1 OF 3)
OCT 2015 DATE OF ISSUE SCALE SHEET NO.
A

REV. DATE 1st APR 2014 AS SHOWN 1 OF 3

10-11
CHAPTER 10 - MAIN PAGE PREVIOUS NEXT
300 X 6 THK M.S. PLATE
WELDED TO CHS BY 6 THK (q) CHS INNER TUBE WELDED
FILLET WELD ALL ROUND B TO BOTTOM PLATE BY
FULL STRENGTH BUTT WELD CHS WELDED TO BASE PLATE BY
A -
FULL STRENGTH BUTT WELD
-

300
8 NOS. 20 THK STIFFENER PLATE (x)
WELDED TO CHS AND BASE PLATE BY
(e) BOTTOM HORIZONTAL SHS FILLET WELD (y) ALL ROUND
WELDED TO CHS BY
FULL STRENGTH BUTT WELD
4 NOS. 6 THK STIFFENER PLATE
WELDED TO CHS AND SHS BY (w) THICKNESS OF BASE PLATE
6 THK FILLET WELD ALL ROUND
4 NOS OF STIFFENER (f) WELDED TO CHS
AND SHS WITH 6 THK FILLET WELD ALL ROUND
(b) TOP HORIZONTAL SHS WELDED TO
CHS BY FULL STRENGTH BUTT WELD
(j) CHS FOR UPPER SECTION OF COLUMN (t) CHS FOR LOWER SECTION OF COLUMN
(j) CHS FOR UPPER SECTION OF COLUMN

125
DETAIL 3 DETAIL 4

50
REF DWG NO: SDRE14/10/SUP11 REF DWG NO: SDRE14/10/SUP11

175
6 THK FILLET WELD ALL ROUND

600
6 THK FILLET WELD ALL ROUND

175
125
50
8 NOS. OF STAINLESS STEEL
75 (FOR TYPE `1' & `6') HOLDING-DOWN BOLTS
50 (FOR THE REST) 125 175 175 125

50
75 (FOR TYPE `1' & `6') 75 100
50 (FOR THE REST)
50

75 100
600

SECTION A-A SECTION B-B BASE PLATE FOR LOWER SECTION OF COLUMN

50
475 DIA
50
(n) 475 DIA TOP PLATE

100 100
50
(j) CHS FOR UPPER SECTION OF

125 100
PROJECTION OF
COLUMN WELDED TO TOP PLATE HORIZONTAL MEMBERS

100 100
BY FULL STRENGTH BUTT WELD

200

150
ON
101

IA ID
p)
O

RECTI
C
V

TRAFFI
.(
(q) CHS INNER TUBE WELDED TO BOTTOM

D
PLATE BY FULL STRENGTH BUTT WELD
101 20 80

DI
50
1000

CHS OF THE UPPER 8 NOS. 10 THK OF STIFFENERS PLATE


SECTION OF COLUMN (j) WELDED TO CHS AND TOP PLATE STIFFENER CUM STIFFENER PLATE
BY FILLET WELD (m) ALL ROUND STIFFENER (k) (7 NOS.)
STOPPER (k1) (1 NO.) DETAIL (x) (8 NOS.)
7 NOS 10 THK STIFFENER PLATE TOP PLATE
WELDED TO CHS AND TOP PLATE
BY FILLET WELD (m) ALL ROUND 20 80 475 DIA
475 DIA
1 NO. 10 THK STIFFENER CUM STOPPER 101
(r) 475 DIA BOTTOM PLATE 101

150
PROJECTION OF
3 THK PTFE SHEET

100 100

100 100
HORIZONTAL MEMBERS

200

200
SANDWICH BETWEEN THE

ID
p)
TWO PLATE (q) CHS INNER TUBE

VO

(
ON

A
DI
RECTI
C
(s) 8 NOS. OF BOLTS

TRAFFI
8 NOS. OF 10 THK STIFFENERS PLATE 50 50
CONNECTING TWO PLATES 50
WELDED CHS BOTTOM 50

DI
PLATE BY FILLET WELD (v) ALL ROUND
CHS OF THE LOWER 8 NOS. 10 THK OF STIFFENERS PLATE STIFFENER CUM
SECTION OF COLUMN (t) WELDED TO CHS AND BOTTOM PLATE
BY FILLET WELD (v) ALL ROUND STIFFENER (u) (7 NOS.) STOPPER (u1) (1 NO.) PTFE SHEET
(t) CHS FOR LOWER
SECTION OF COLUMN

BOTTOM PLATE
The dimension of the components in the drawings shall be taken as the minimum size required.

DETAIL 5 The bolts shown in column 's' shall be strictly followed as highlighted in drawing note no 12.

REF DWG NO: SDRE14/10/SUP11 The specified structural strength of the components shall be checked by professional engineer.

STANDARD DETAIL

SUPPORT FOR CANTILEVER DRAWING NO. REV.


DIRECTIONAL SIGNS LTA/SDRE14/10/SUP12 -
(SHEET 2 OF 3)
DATE OF ISSUE SCALE SHEET NO.

REV. DATE 1st APR 2014 1:20 2 OF 3

10-12
CHAPTER 10 - MAIN PAGE PREVIOUS NEXT
TABLE FOR SUPPORT FOR CANTILEVER DIRECTIONAL SIGNS

NOS. OF 100 x DETAILS OF TOP HORIZONTAL DETAILS OF BOTTOM HORIZONTAL DETAILS OF UPPER SECTION OF DETAILS OF TOP PLATE OF DETAILS OF BOTTOM PLATE DETAILS OF 8 NOS. OF BOLTS
100 x 6 THK MEMBER OF GRADE 43 STEEL MEMBER OF GRADE 43 STEEL COLUMN OF GRADE 43 STEEL 475 DIA (GRADE 43) OF GRADE 43 STEEL CONNECTING THE TWO PLATES
CHS OF INNER
SHS OF GRADE
SIZE OF STIFFENER FILLET WELD SIZE OF STIFFENER FILLET WELD SIZE OF STIFFENER FILLET WELD TOP PLATE DIAMETER OF TUBE -GRADE 43 BOTTOM PLATE DIAMETER OF GRADE DIAMETER
43 STEEL
SHS PLATE THK LEG LENGTH SHS PLATE THK LEG LENGTH CHS PLATE THK LEG LENGTH THK CENTRAL VOID THK BOTTOM PLATE OF BOLTS OF BOLTS
TYPE
(h) (I) (a) (b) (c) (d) (e) (f) (g) (j) (k, k1) (m) (n) (p) (q) (r) (s) (s)
NO.
(m) (m) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)

1 2.50 ≤ l ≤ 3.75 2 150 X 150 X 6 6 6 150 X 150 X 12.5 8 6 273 X 8 CHS 10 6 16 257 219.1 X 8.0 CHS 16 475 GRADE 4.6 16

2 3.75 < l ≤ 4.70 2 200 X 200 X 6 6 6 200 X 200 X 16.0 15 6 273 X 16 CHS 10 12 25 241 219.1 X 12.5 CHS 25 475 GRADE 4.6 20

3 1.0 ≤ h ≤ 1.5 4.70 < l ≤ 5.60 2 200 X 200 X 6 6 6 200 X 200 X 16.0 15 6 273 X 16 CHS 10 12 25 241 219.1 X 12.5 CHS 25 475 GRADE 4.6 22

4 5.60 < l ≤ 6.60 3 200 X 200 X 6 6 6 200 X 200 X 16.0 15 6 273 X 16 CHS 10 12 25 241 219.1 X 12.5 CHS 25 475 GRADE 4.6 24

5 6.60 < l ≤ 7.50 3 200 X 200 X 6 6 6 200 X 200 X 16.0 15 6 273 X 16 CHS 10 12 25 241 219.1 X 12.5 CHS 25 475 GRADE 4.6 27

6 2.50 ≤ l ≤ 3.75 2 150 X 150 X 6 6 6 150 X 150 X 12.5 8 6 273 X 8 CHS 10 8 16 257 219.1 X 8.0 CHS 16 475 GRADE 4.6 16

7 3.75 ≤ l ≤ 4.50 2 250 X 250 X 6 6 6 250 X 250 X 12.5 20 6 273 X 20 CHS 10 15 25 233 219.1 X 20.0 CHS 25 475 GRADE 4.6 20

8 1.5 ≤ h ≤ 2.5 4.50 ≤ l ≤ 5.25 2 250 X 250 X 6 6 6 250 X 250 X 12.5 20 6 273 X 20 CHS 10 15 25 233 219.1 X 20.0 CHS 25 475 GRADE 4.6 22

9 5.25 ≤ l ≤ 6.00 2 250 X 250 X 6 6 6 250 X 250 X 12.5 20 6 273 X 20 CHS 10 15 25 233 219.1 X 20.0 CHS 25 475 GRADE 8.8 16

10 6.00 < l ≤ 6.75 3 250 X 250 X 6 6 6 250 X 250 X 12.5 20 6 273 X 20 CHS 10 15 25 233 219.1 X 20.0 CHS 25 475 GRADE 4.6 27

11 6.75 ≤ l ≤ 7.50 3 250 X 250 X 6 6 6 250 X 250 X 12.5 20 6 273 X 20 CHS 10 15 25 233 219.1 X 20.0 CHS 25 475 GRADE 8.8 20

800

8T28

800
TABLE FOR SUPPORT FOR CANTILEVER DIRECTIONAL SIGNS
3000

T13-250 LINK T13-125 LINK DETAILS OF LOWER SECTION OF COLUMN DETAILS OF BASE PLATE

SECTION B-B TYPE


GRADE OF SIZE OF STIFFENER FILLET WELD GRADE OF THK OF STIFFENER FILLET WELD
NO. STEEL CHS PLATE THK LEG LENGTH STEEL BASE PLATE PLATE THK LEG LENGTH
800 x 800 (t) (t) (u, u1) (v) (w) (w) (x) (y)
STUMP (mm) (mm) (mm) (mm) (mm) (mm)

1 GRADE 43 273 X 16 10 6 GRADE 43 40 12 15


400

A 2 GRADE 50 273 X 25 10 12 GRADE 50 50 20 18


HIGH STRENGTH NON-SHRINK
- CEMENTITIOUS GROUT OF
100
400

3 GRADE 50 273 X 25 10 12 GRADE 50 50 20 18


MINIMUM STRENGTH 40N/mm 2

4 GRADE 50 273 X 25 10 12 GRADE 50 50 20 18


600

350 400 400 350 8 NOS. OF 30 DIA STAINLESS STEEL 5 GRADE 50 273 X 25 10 12 GRADE 50 50 20 18
HOLDING-DOWN BOLTS CONFORMING
1500 B TO BS EN ISO 3506 GRADE A4-80 6 GRADE 43 273 X 16 10 8 GRADE 43 40 12 15
NK

4 NOS. 100 X 100 X 6 THK


1500

T13 LI

- ANGLE WELDED TO FORM A SQUARE 7 GRADE 50 323.9 X 20 10 15 GRADE 50 50 20 18


3000

8 GRADE 50 323.9 X 20 10 15 GRADE 50 50 20 18


13T20 8T28
9 GRADE 50 323.9 X 20 10 15 GRADE 50 50 20 18
T13-150

10 GRADE 50 323.9 X 20 10 15 GRADE 50 50 20 18


500

1T20 1T20
11 GRADE 50 323.9 X 20 10 15 GRADE 50 50 20 18

75 THK LEAN CONCRETE


13T20 T13-150
1500

FOOTING PLAN SECTION A-A


The dimension of the components in the drawings shall be taken as the minimum size required.
The bolts shown in column 's' shall be strictly followed as highlighted in drawing note no 12.
DETAILS OF FOUNDATION
The specified structural strength of the components shall be checked by professional engineer.
SCALE 1:50

STANDARD DETAIL

SUPPORT FOR CANTILEVER DRAWING NO. REV.


DIRECTIONAL SIGNS LTA/SDRE14/10/SUP13 A
(SHEET 3 OF 3)
A OCT 2015
DATE OF ISSUE SCALE SHEET NO.

REV. DATE 1st APR 2014 AS SHOWN 3 OF 3

10-13
CHAPTER 10 - MAIN PAGE PREVIOUS NEXT

1 50 X 50 BOTTOM RAIL OF
5 NOS. 12 DIA
PEDESTRIAN OVERHEAD BRIDGE
- ADHESIVE TYPE
ANCHOR BOLTS
2 NOS. 10 DIA BOLTS 13
0

DISTANCE TO BE ADJUSTED
ACCORDING TO BEAM DESIGN
AND SPECIFICATION REQUIREMENT
WALL / BEAM
( < 1000 = )

250
200
50
50
38 X 9
FLAT BAR

1000
500
HIGH BOND HIGH BOND
TAPE WITH TAPE WITH
6 NOS. OF 6 NOS. OF
10 DIA 10 DIA
BOLTS WITH BOLTS WITH
WASHERS FOR WASHERS FOR
SIGN SIGN

67
10 DIA BOLT

38 X 9
FLAT BAR

38
67

50 X 50
(EXTERNAL)
BOTTOM RAIL 0
40
OF PEDESTRIAN
OVERHEAD BRIDGE
75

100
38

DETAIL 1 TYPE A TYPE B


SCALE 1:50 (FOR DIMENSION REFER TO TYPE A)
SCALE 1:100
SCALE 1:100

NOTES: STANDARD DETAIL


1. All steel brackets and flats bar are to be of stainless steel.
2. All bolts and nuts are to be of stainless steel.
3. All joints are to be fully welded.
TYPICAL STEEL BRACKETS
4. Where aluminium are used instead of stainless steel. The grade of aluminium
FOR 4.5m HEIGHT DRAWING NO. REV.
shall of HE 30 WP.
LIMIT SIGN LTA/SDRE14/10/SUP14 -
(900mm x 900mm)
DATE OF ISSUE SCALE SHEET NO.

REV. DATE 1st APR 2014 AS SHOWN 1 OF 1

10-14
CHAPTER 10 - MAIN PAGE PREVIOUS

VARIES VARIES

ES

ES
4.8 DIA RIVETS 4.8 DIA RIVETS

VARI

VARI
(NOT MORE THAN (NOT MORE THAN
150 APART) 150 APART)

TRAFFIC SIGN TRAFFIC SIGN

75 X 75 X 3 THK 100 X 100 X 3 THK


HOT DIPPED GALVANISED HOT DIPPED GALVANISED
SQUARE HOLLOW SECTION SQUARE HOLLOW SECTION
2400

2400
EXPANSION BOLTS HOLE
CEMENT MORTAR CEMENT MORTAR
1 300 X 300 X 75 1 300 X 300 X 75 200 X 200 X 10 THK M.S. PLATE
(ON FOOTPATH) (ON FOOTPATH)
- 400 X 400 X 75 - 400 X 400 X 75
(ON FOUNDATION) (ON FOUNDATION)

40
40

200
SHS

FULL WELD

550 X 550 X 550 650 X 650 X 650


C16/20 CONCRETE C16/20 CONCRETE

200

VERTICAL SUPPORTS FOR TRAFFIC SIGN VERTICAL SUPPORTS FOR TRAFFIC SIGN PLAN
WITH AREA NOT EXCEEDING 1.1m² WITH AREA NOT EXCEEDING 2.3m² DETAIL 1
FOR ARTERIAL ROAD FOR EXPRESSWAY REF DWG NO: SDRE14/10/SUP4
SCALE 1:5
SCALE 1:20 SCALE 1:20

STANDARD DETAIL

SUPPORT FOR
TRAFFIC SIGN DRAWING NO. REV.

(FOR ARTERIAL AND LTA/SDRE14/10/SUP15 -


EXPRESSWAY)
DATE OF ISSUE SCALE SHEET NO.

REV. DATE SEP 2017 AS SHOWN 1 OF 1

10-15