SOLUTIONS
GUIDE
Solutions guide
Index
Introduction
Zoning systems 3
Efficient control
· Q-Adapt
· Eco-Adapt
· BMS Integration
Solutions
Commercial 6
Single-family applications 10
74º
It permits to individually control the temperature of every zone conditioned by the same ducted indoor
unit. This occurs thanks to the communications that exist between the sensors installed on each zone
and the motorized elements installed on ducts. Because of this, it allows the system to cover only the
thermal load of those zones where both thermal demand and occupancy exists.
% Comfort % Efficiency
100 60
50
80
40
60
30
40
20
20 10
0 0
Living kitchen Bed Bed
Room Room1 Room2
% of time in comfort
The cornerstone of this system is the communications It sets the following parameters according to the
gateway, a device that manages the communication zones status:
between the integrated zoning system and heat pump
Inverter units, increasing both comfort and energy • The operation mode
savings. The heat pump and integrated zoning system • The heat pump set-point temperature
will work as one thanks to the Airzone Communication • The ventilation speed
Gateway.
Due to these features, Airzone VAF does not require
All the zones information is gathered to determine the any bypass damper, making it the most efficient zoning
most efficient operation of the heat pump equipment. solution for HVAC installations.
The Airzone Blueface thermostat allows users to quickly In addition, the end user will be able to, by means of the
adjust the temperature at which the HVAC system is Blueface thermostat, adjust the set point temperature
operating and also to regulate it depending on their of every room in order to optimize the energy savings.
requirements.
Oversized
indoor units
Refrigerant
pipes length and
refrigerant quantity
Noncompliance with
ASHRAE 15 & 34 /
B-52 Standards
Costly
maintenance
15% reduction in
installed thermal
power
49.5% reduction in
pipes length
27.5% reduction
in refrigerant
charge
Compliance with
ASHRAE 15 & 34/
B-52 standards*
The case study, consisting of eight Offices and an IT By implementing a combination of an Airzone ZBS
Room has been calculated using two different options system and ducted indoor units to a VRF system, a user
(VRF Installation with individual indoor units and VRF creates a system that optimizes efficiency.
Installation with ducted and individual indoor units).
*According to ASHRAE 15 & 34/B-52, lowest allowed volume of a room crossed by a refrigerant pipe has been reduced from 1819.1 ft3 to 1319.8 ft3.
4 5
2 3
BACNET BMS
SYSTEMS
6
1
2 3 4
7
BACNET BMS
SYSTEMS
5 6
2 3 4
WIFI CLOUD 7
5 6
WIFI CLOUD 7
8 2 3 4