Вы находитесь на странице: 1из 10

Canon iR2530 Error Codes List page 1 (from 5)

Code Description Remedy


1.Go through the following to clear the error:
CLEAR > ENGIN > ERRCLR; and then turn
Fixing temperature abnormal rise
OFF and then ON the power. 2.Check
The temperature detected by the
E000- connection of the Connectors (Thermistor
main thermistor does not rise to
0001 Connector and AC Connector). 3.Replace the
the specified value during startup
Fixing Main Thermistor (Film Unit). 4.Replace
control.
the Fixing Assembly. 5.Replace the DC
Controller PCB (PCB4).
1.Go through the following to clear the error:
CLEAR > ENGIN > ERRCLR; and then turn
Fixing unit temperature rise
OFF and then ON the power. 2.Check
detection
E001- connection of the Connectors (Thermistor
The reading of the main
0000 Connector and AC Connector). 3.Replace the
thermistor is 250 deg C or more
Fixing Main Thermistor (Film Unit). 4.Replace
continuously for 200 msec.
the Fixing Assembly. 5.Replace the DC
Controller PCB (PCB4).
Fixing unit temperature rise
1.Go through the following to clear the error:
detection
E001- CLEAR > ENGIN > ERRCLR; and then turn
The hardware circuit detects
0001 OFF and then ON the power. 2.Replace the
overheating of the main or sub
DC Controller PCB (PCB4).
thermistor for 200 msec.
1.Go through the following to clear the error:
CLEAR > ENGIN > ERRCLR; and then turn
Fixing unit temperature rise
OFF and then ON the power. 2.Check
detection
E001- connection of the Connectors (Thermistor
The reading of the sub thermistor
0002 Connector and AC Connector). 3.Replace the
is 295 deg C or more
Fixing Main Thermistor (Film Unit). 4.Replace
continuously for 200 msec.
the Fixing Assembly. 5.Replace the DC
Controller PCB (PCB4).
Fixing unit temperature
insufficient rise
1.Go through the following to clear the error:
1.The reading of the main
CLEAR > ENGIN > ERRCLR; and then turn
thermistor is less than 115 deg C
OFF and then ON the power. 2.Check
continuously for 400 msec 1.3
E002- connection of the Connectors (Thermistor
sec after it has indicated 100 deg
0000 Connector and AC Connector). 3.Replace the
C. 2.The reading of the main
Fixing Main Thermistor (Film Unit). 4.Replace
thermistor is less than 150 deg C
the Fixing Assembly. 5.Replace the DC
continuously for 400 msec 1.3
Controller PCB (PCB4).
sec after it has indicated 140 deg
C.
1.Go through the following to clear the error:
Low fixing temperature detection CLEAR > ENGIN > ERRCLR; and then turn
after standby OFF and then ON the power. 2.Check
E003- The reading of the main connection of the Connectors (Thermistor
0000 thermistor is less than 140 deg C Connector and AC Connector). 3.Replace the
continuously for 400 msec or Fixing Main Thermistor (Film Unit). 4.Replace
more. the Fixing Assembly. 5.Replace the DC
Controller PCB (PCB4).
Thermistor disconnection
1.Check connection of the Connector (J214).
detection error
E004- 2.Replace the Film Unit. 3.Replace the Fixing
When disconnection is detected
0000 Assembly. 4.Replace the DC Controller PCB
with connector (J214) for 30 sec
(PCB4).
continuously.
Unstable rotation of the Main
Motor (M1)
Detection is executed every 100
E010- 1.Replace the Main Motor (M1). 2.Replace the
msec after the start of motor
0001 DC Controller PCB (PCB4).
rotation; however, the drive
detection signal is absent for 2
sec.
Unstable rotation of the Main
Motor (M1)
E010- During motor rotation, detection 1.Replace the Main Motor (M1). 2.Replace the
0002 is executed every 100 msec; DC Controller PCB (PCB4).
however, the drive signal is
absent 5 times in sequence.
Unstable rotation of the Fixing
Motor (M2)
Detection is executed every 100
E014- 1.Replace the Fixing Motor (M2). 2.Replace
msec after the start of motor
0001 the DC Controller PCB (PCB4).
rotation; however, the drive
detection signal is absent for 2
sec.
Unstable rotation of the Fixing
Motor (M2)
E014- During motor rotation, detection 1.Replace the Fixing Motor (M2). 2.Replace
0002 is executed every 100 msec; the DC Controller PCB (PCB4).
however, the drive signal is
absent 5 times in sequence.
Error in Waste Toner Sensor
E019- (S17) 1.Replace the Waste Toner Sensor (S17).
0000 Warning when the sensor goes 2.Replace the DC Controller PCB (PCB4).
on for 2000 consecutive sheets,
and error when the sensor goes
on for 100 consecutive sheets.
* Error occurs after the delivery if
a paper in passage exists.
The path between the sub
hopper and the developing
assembly is clogged with toner.
The Developing Assembly Toner
Sensor (TS1) detects the
absence of toner,while the Sub 1.Check the rotation of hopper motor gear. (If
Hopper Toner Sensor (TS2) rotating, false detection by the sensor is
detects the presence of toner. doubted. Feed the toner to the developing unit
E020- With the Developing Cylinder in service mode: CLEAR>ENGIN>TNRINST.)
0000 Clutch (CL3) turned on, the 2.Replace the Developing Assembly Toner
hopper feedscrew motor (M7) is Sensor (TS1). 3.Replace the Sub Hopper
rotated for 1 sec intermittently Toner Sensor (TS2). 4.Replace the DC
194 times; still, theDeveloping Controller PCB (PCB4).
Assembly Toner Sensor (TS1)
does not detect the presence of
toner.
* Error occurs after the delivery if
a paper in passage exists.
The connector (J207) of
Developing Assembly Toner
Sensor (TS1) is disconnected.
1.Check connection of the Connector (J207).
The Developing Assembly Toner
E024- 2.Replace the Developing Assembly Toner
Sensor (TS1) connection
0000 Sensor (TS1). 3.Replace the DC Controller
detection signal is absent for 100
PCB (PCB4).
msec 10 times in sequence. *
Error occurs after the delivery if a
paper in passage exists.
The Developing Assembly Toner
Sensor (TS1) is disconnected
<At LOW SPEED> - The
developing assembly toner
sensor (TS1) ON counter is
checked every 2.5 seconds, and
1.Check connection of the Connector (J207).
E024- the counter increments 1 count
2.Correct the cable. 3.Replace the Developing
0001 every 25 times when the sensor
Assembly Toner Sensor (TS1).
goes on, and 300 counts are
reached.
<At HIGH SPEED> - The
developing assembly toner
sensor (TS1) ON counter is
checked every 1.5 seconds, and
the counter increments 1 count
every 15 times when the sensor
goes on, and 300 counts are
reached.

Code Description Remedy


The connector (J207) of Sub
Hopper Toner Sensor (TS2) is
disconnected.
1.Check connection of the Connector
The Sub Hopper Toner Sensor
E025- (J207). 2.Replace the Sub Hopper Toner
(TS2) connection detection signal is
0000 Sensor (TS2). 3.Replace the DC Controller
absent for 100 msec 10 times in
PCB (PCB4).
sequence.
* Error occurs after the delivery if a
paper in passage exists.
Failure of the Bottle Motor (M6)
The bottle motor (M6) is unlocked
E025- when it goes on for 12 consecutive 1.Replace the Bottle Motor (M6).
0001 times at 0.1 sec. intervals. 2.Replace the DC Controller PCB (PCB4).
* Error occurs after the delivery if a
paper in passage exists.
Failure of the Scanner Motor (M21)
The Scanner Motor (M21) speed
lock signal does not indicate a
1.Check the cable. 2.Replace the Laser
E110- locked state a specific period of time
Scanner Unit. 3.Replace the DC Controller
0001 after the Scanner Motor (M21) has
PCB (PCB4).
been started.
* The same condition is detected
after the error retry is performed.
Failure of the Scanner Motor (M21)
The speed lock signal indicates a
deviation 10 times in sequence at 1.Check the cable. 2.Replace the Laser
E110-
intervals of 100 msec after the Scanner Unit. 3.Replace the DC Controller
0002
signal has indicated a locked state. PCB (PCB4).
* The same condition is detected
after the error retry is performed.
Failure of the Scanner Motor (M21)
The scanner motor (M21) speed
1.Check the cable. 2.Replace the Laser
E110- lock signal does not indicate a
Scanner Unit. 3.Replace the DC Controller
0003 locked state for 6.5 sec. after a
PCB (PCB4).
switchover is made from low to
normal speed or for 8 sec. after a
switchover is made from normal to
low speed.
* The same condition is detected
after the error retry is performed.
Error in EEPROM access
20 retries failed after error occurred
E196- during communication with
1.Replace the DC Controller PCB (PCB4).
0000 EEPROM.
* Error occurs after the delivery if a
paper in passage exists.
Error in communication of Laser
1.Check the cable. 2.Replace the Laser
E197- Driver PCB (PCB14)
Scanner Unit. 3.Replace the DC Controller
0000 Communication error 1 with image
PCB (PCB4).
PCB
Error in communication of Laser
1.Check the cable. 2.Replace the Laser
E197- Driver PCB (PCB14)
Scanner Unit. 3.Replace the DC Controller
0001 Communication error 2 with image
PCB (PCB4).
PCB
There is an error in the detection of 1.Disconnect and then connect the flexible
the CIS home position. cable(Relay PCB (PCB2)-Main Controller
1.The attempt to detect the home PCB (PCB1) 64pin). 2.Replace the flexible
E202- position fails when the CIS is moved cable. 3.Replace the CIS HP sensor (S31).
0000 forward. 4.Replace the Scanner Motor (M31).
2.The attempt to detect the home 5.Replace the Relay PCB (PCB2).
position fails when the CIS is moved 6.Replace the Main Controller PCB
back. (PCB1).
Error in controller communication
E240- The serial communication error such 1.Check the Connectors. 2.Replace the
0000 as parity error or overrun error is DC Controller PCB (PCB4).
constantly detected.
Error in controller communication
E240- The serial communication error such 1.Check the Connectors. 2.Replace the
0001 as parity error or overrun error is DC Controller PCB (PCB4).
detected while printing.
E246- Writing to the counter PCB (FRAM)
0000 failed
E247- Mismatched checksum between the
0000 Flash Rom and the FRAM
Error in Zero Cross
E261- Zero Cross failed to be detected for 1.Check the Connectors. 2.Replace the
0000 500ms or more while the relay was DC Controller PCB (PCB4).
ON.
* The same condition is detected
after the error retry is performed.

Code Description Remedy


E354- Mismatched serial number for
0000 the SOFT-ID PCB
Mismatched serial number
E355-
between the SOFT-ID, the
0000
Flash Rom and the FRAM
E355-
System information error
0004
E355-
System information error
0005
Communication error 1.Check the cable. 2.Replace the Finisher
E500-
The communication with the Controller PCB (PCB1). 3.Replace the DC
0000
host machine is interrupted. Controller PCB.
EEPROM error
E505- 1.Replace the Finisher Controller PCB
The checksum for the EEPROM
0001 (PCB1).
data has an error.
Shift Motor (M4) error
The shift roller does not leave 1.Replace the Shift Roller HP Sensor (S2).
E520-
the shift roller home position 2.Replace the Shift Motor (M4). 3.Replace the
0001
when the Shift Motor (M4) has Finisher Controller PCB (PCB1).
been driven for 1.2 seconds.
Shift Motor (M4) error
The shift roller does not return 1.Replace the Shift Roller HP Sensor (S2).
E520-
to the shift roller home position 2.Replace the Shift Motor (M4). 3.Replace the
0002
when the Shift Motor (M4) has Finisher Controller PCB (PCB1).
been driven for 1.2 seconds.
Stapler Motor (M10) error
1.Check the wiring between the Finisher
The stapler does not leave the
E531- Controller PCB and Stapler. 2.Replace the
staple home position when the
8001 Stapler. 3.Replace the Finisher Controller PCB
Staple Motor (M10) has been
(PCB1).
driven for 0.5 sec.
Stapler Motor (M10) error
1.Check the wiring between the Finisher
The stapler does not return to
E531- Controller PCB and Stapler. 2.Replace the
the staple home position when
8002 Stapler. 3.Replace the Finisher Controller PCB
the Stapler Motor (M10) has
(PCB1).
been driven for 0.5 sec.
1.Replace the Stapler Move HP Sensor (S10).
STP Move Motor (M1) error
2.Check the wiring between the Finisher
The stapler does not leave the
E532- Controller PCB and the STP Move Motor.
stapler move home position
0001 3.Check the stapler shift base. 4.Replace the
when the STP Move Motor (M1)
STP Move Motor (M1). 5.Replace the Finisher
has been driven for 0.25 sec.
Controller PCB (PCB1).
1.Replace the Stapler Move HP Sensor (S10).
STP Move Motor (M1) error
2.Check the wiring between the Finisher
The stapler does not return to
E532- Controller PCB and the STP Move Motor.
the stapler move home position
0002 3.Check the stapler shift base. 4.Replace the
when the STP Move Motor (M1)
STP Move Motor (M1). 5.Replace the Finisher
has been driven for 2.8 sec.
Controller PCB (PCB1).
Tray Lift Motor (M11) time out
1.Replace the Tray Lift Motor (M11).
E540- error
2.Replace the Finisher Controller PCB
0001 The stack tray does not move
(PCB1).
within a specified time period.
Tray Lift Motor (M11) closing
detect switch error 1.Replace the Stack Tray Clock Sensor (S13).
E540- The FG input cannot be 2.Replace the Tray Lift Motor (M11).
0005 detected when the Tray Lift 3.Replace the Finisher Controller PCB
Motor (M11) has been driven for (PCB1).
0.1 second.
Additional Tray Lift Motor (M12)
1.Replace the Additional Tray Lift Motor (M12).
E542- time out error
2.Replace the Finisher Controller PCB
0001 The stack tray does not move
(PCB1).
within a specified time period.

Code Description Remedy


Additional Tray Lift Motor (M12) closing 1.Replace the Additional Tray Clock
detect switch error Sensor (S23). 2.Replace the
E542-
The FG input cannot be detected when Additional Tray Lift Motor (M12).
0005
the Additional Tray Lift Motor (M12) has 3.Replace the Finisher Controller
been driven for 0.1 second. PCB (PCB1).
Shift Roller Release Motor (M5) error
1.Replace the Shift Roller Release
The shift roller does not leave the shift
E567- Sensor (S3). 2.Replace the Shift
roller release home position when the
0001 Roller Release Motor (M5). 3.Replace
Shift Roller Release Motor (M5) has
the Finisher Controller PCB (PCB1).
been driven for 0.1 sec.
Shift Roller Release Motor (M5) error 1.Replace the Shift Roller Release
E567-
The shift roller does not return to the Sensor (S3). 2.Replace the Shift
0002
shift roller release home position when Roller Release Motor (M5). 3.Replace
the Shift Roller Release Motor (M5) has the Finisher Controller PCB (PCB1).
been driven for 0.06 sec.
Gripper Open/Close Motor (M7) error
1.Replace the Grip Arm Sensor
The gripper unit does not leave the
E571- (S13). 2.Replace the Gripper
gripper unit home position when the
0001 Open/Close Motor (M7). 3.Replace
Gripper Open/Close Motor (M7) has
the Finisher Controller PCB (PCB1).
been driven for 0.25 seconds.
Gripper Open/Close Motor (M7) error
1.Replace the Grip Arm Sensor
The gripper unit does not return to the
E571- (S13). 2.Replace the Gripper
gripper unit home position when the
0002 Open/Close Motor (M7). 3.Replace
Gripper Open/Close Motor (M7) has
the Finisher Controller PCB (PCB1).
been driven for 0.15 seconds.
Gripper Unit Move Motor (M2) error
1.Replace the Gripper Unit HP
The gripper unit does not leave the
E575- Sensor (S7). 2.Replace the Gripper
gripper unit home position when the
0001 Unit Move Motor (M2). 3.Replace the
Gripper Unit Move Motor (M2) has been
Finisher Controller PCB (PCB1).
driven for 3.8 seconds.
Gripper Unit Move Motor (M2) error
1.Replace the Gripper Unit HP
The gripper unit does not return to the
E575- Sensor (S7). 2.Replace the Gripper
gripper unit home position when the
0002 Unit Move Motor (M2). 3.Replace the
Gripper Unit Move Motor (M2) has been
Finisher Controller PCB (PCB1).
driven for 0.1 seconds.
E602-
The built-in SD card is not detected
0001
E602-
Access to the built-in SD card failed
1105
Error in UFDI communication 1.Check and Replace the cable.
E711- The communication system error (such 2.Replace the DC Controller PCB
0001 as reception timeout or checksum error) (PCB4). 3.Replace the Finisher
occurred. Controller PCB.
Erroneous communication with finisher
1.Check the cable. 2.Replace the DC
E713- The communication does not restart by
Controller PCB (PCB4). 3.Replace
0000 the error retry after the communication
the Finisher Controller PCB.
failure with the finisher.
Erroneous communication with optional
cassette or 2-way unit 1.Check the cable. 2.Replace the DC
E716- After the presence of a cassette Controller PCB (PCB4). 3.Replace
0000 pedestal or a 2-way unit has been the Cassette Pedestal Driver PCB.
detected, the communication fails to be 4.Replace the 2-way unit driver PCB.
normal for 5 sec.
E716- Failure of the communication with the 2- 1.Install the 2-way unit. 2.Check the
0010 way unit cable. 3.Replace the DC Controller
When the communication with the 2- PCB (PCB4). 4.Replace the 2-way
way unit is faulty after detecting the unit driver PCB.
connection with the finisher.
E719- Erroneous communication with New
0000 Card Reader (serial communication)
E719- Erroneous communication with Coin
0002 Vendor (serial communication)

Code Description Remedy


E736- Erroneous communication between
0000 CCU and controller.
E744- Mismatched version between the
0001 language file and the Bootable
E744-
Oversized language file in HDD
0002
E744- Mismatched version between the
0003 language file and the Bootable
E744-
Language file reading error
0004
Failure of the Power Supply
Cooloing Fan (FAN6) 1.Disconnect and then connect the
When lock signal is detected for 5 connector (J205) on the DC Controller
E804-
sec while the Power Supply PCB (PCB4). 2.Replace the Power Supply
0000
Cooloing Fan (FAN6) is stopped. Cooloing Fan (FAN6). 3.Replace the DC
* The same condition is detected Controller PCB (PCB4).
after the error retry is performed.
Unstable rotation of the Power
Supply Cooloing Fan (FAN6)
1.Disconnect and then connect the
When lock signal failed to be
connector (J205) on the DC Controller
E804- detected for 5 sec while the Power
PCB (PCB4). 2.Replace the Power Supply
0001 Supply Cooloing Fan (FAN6) is
Cooloing Fan (FAN6). 3.Replace the DC
driven.
Controller PCB (PCB4).
* The same condition is detected
after the error retry is performed.
Failure of the Exhaust Fan (Rear) 1.Disconnect and then connect the
(FAN3) connector (J206) on the DC Controller
E805-
When lock signal is detected for 5 PCB (PCB4). 2.Replace the Exhaust Fan
0000
sec while the Exhaust Fan (Rear) (Rear) (FAN3). 3.Replace the DC
(FAN3) is stopped. Controller PCB (PCB4).
* The same condition is detected
after the error retry is performed.
Unstable rotation of the Exhaust
Fan (Rear) (FAN3) or Finisher Fan
1 (M8) or Finisher Fan 2 (M9)
1.When lock signal failed to be
detected for 5 sec while the Exhaust 1.Disconnect and then connect the
Fan (Rear) (FAN3) is driven. connector (J206) on the DC Controller
E805- 2.When lock signal failed to be PCB (PCB4). 2.Replace the Exhaust Fan
0001 detected for 5 sec while the Finisher (Rear) (FAN3). 3.Replace the Finisher Fan
Fan 1 (M8) is driven. 3.When lock 1 (M8). 4.Replace the Finisher Fan 2 (M9).
signal failed to be detected for 5 sec 5.Replace the DC Controller PCB (PCB4).
while the Finisher Fan 2 (M9) is
driven.
* The same condition is detected
after the error retry is performed.
Failure of the Exhaust Fan (Front)
(FAN4) 1.Disconnect and then connect the
When lock signal is detected for 5 connector (J206) on the DC Controller
E805-
sec while the Exhaust Fan (Front) PCB (PCB4). 2.Replace the Exhaust Fan
0002
(FAN4) is stopped. * The same (Front) (FAN4). 3.Replace the DC
condition is detected after the error Controller PCB (PCB4).
retry is performed.
Unstable rotation of the Exhaust
Fan (Front) (FAN4) 1.Disconnect and then connect the
When lock signal failed to be connector (J206) on the DC Controller
E805-
detected for 5 sec while the Exhaust PCB (PCB4). 2.Replace the Exhaust Fan
0003
Fan (Front) (FAN4) is driven. (Front) (FAN4). 3.Replace the DC
* The same condition is detected Controller PCB (PCB4).
after the error retry is performed.