1.

One is not found involve in colorimetric:


a. Cuvette b. light source c. photo sensor and analyser d. fule source e. filter
2. The atomic mass of an atom is the number of:
a. Protons and neutrons b. protons only c. neutrons only d. electrons e. none of the above
3. Deionization of impure water means:
a. Boiling b. filtration c. exchange of protons and electrons d. exchange of neutrons and
electrons e. exchange of neutrons and protons
4. Most common method (technique) used to detect hormone amount in the laboratories:
a. UV-Spectrophotometry b. enzyme linked immunosurbant assay (ELIZA) c. Gas Chromatography
-Mass Spectrometry d. HPLC e. None of the above
5. Buffer solution is:
a. Changing colour when changing pH b. resist acidic pH c. resist alkaline pH d. Weak acid + weak
base e. Strong acid + weak base
6. An indicator is:
a. Change colour with change pH b. resist acidic pH c. resist alkaline pH d. weak acid + weak base
e. strong acid + weak base
7. In spectrophotometric determination, the amount of light of a specific wavelength absorbed by a
coloured solution is: a. Directly proportional to the intensity of the colour b. directly proportional
to the concentration of solute in the solution c. indirectly proportional to the concentration of solute
in the solution d. indirectly proportional to the intensity of the colour e. None of the above
8. Heparin is:
a. Protein b. enzyme c. polysaccharide d. oligosaccharide e. none of the above
9. How much water should we add to 500ml of a solution of 10% of NAOH to bring it to 7.5%?
a. 666 b. 250 c. 166 d. 476 e. 662
10. Which of the following is not find in the flame photometry:
a. Burner b. filter c. fuel source d. cuvette for sample e. photo
11. A buffer made of …………………………………………? a. strong acid + strong salt b. weak acid + weak
salt c. weak acid + strong salt d. strong acid + weak salt e. none of the above
12. if five ml of coloured solution has an absorbance of 0.500 nm, what will be the absorbance of 10
ml of the same solution. a.1.000 nm b. 0.250 nm c. 0.500 nm d. 0.050 nm e. 0.100 nm
13. The purpose of standard deviation is to? a. measure external quality control b. measure internal
quality control c. both a and b d. addition of values e. none of the above
14. In spectrophotometeric, the amount of light absorbed is: a. Directly proportional to the amount
of light transmitted b. Inversely proportional to the amount of solute c. Directly proportional to the
concentration of the analyte d. Inversely proportional to the absorbance e. Inversely proportional
to the emitted colour
15. To obtain an isotonic media, the Sodium chloride content should be: a. 0.85 g % b. 0.085 g%
c . 8.5 g% d. 6.5 g% e. 0.50 g
16. The life span of red blood cells in the circulation (body): a. 80 days b. 120 day c. 130 day d.
20 day e. 5- 7 day
17. A standard micro plates in ELISA test has? a. 75 wells b. 50 wells c. 96 wells d. 34 wells e.
102 wells
18. The sterilization of autoclave is? a. 85c for 30 min b. 150 oc for 30 min c. 121oc for 15 min d.
101oc for 15min e. 115 oc for 25 min
19. Bacteria can cause pathogenesis to human by: a. Capsullar b. secret enzymes c. endogenous
toxins d. exogenous toxins e. all of the above
20. The best kidney function test? a. Urea b. total protein c. creatinine d. glucose e. albumin

Solution
1. D
2. A
3. C
4. B
5. D
6. A
7. C
8. A
9. C
10. D
11. C
12. C
13. E
14. C
15. A
16. B
17. C
18. C
19. E
20. c