A N OT H E R D I M E N S I O N VACUUM DISTILLATION

AD1160 Automated Vacuum Distillation Analyzer

Everything you need for accurate,


repeatable vacuum distillations…
ASTM D 1160, ISO 6616, JIS K 2254

A n easy to operate instrument, ISL’s AD1160 determines distillation char-


acteristics of petroleum products at reduced pressure. Pressure, distilla-
tion rate, and all parameters specified in ASTM D1160 are tightly controlled
to ensure accurate, repeatable results.
The AD1160 contains everything needed for analysis and documentation
and stores up to 20 distillation programs, each with customized settings for
various testing parameters.

Turn-key system
No bench space required
0ºC at +700ºC AET range
760mm Hg down to 0.1mm Hg pressure
Automatic cleaning program
Programmable pressure reduction steps to prevent flooding
Optional PC-controlled data acquisition and management

SIMPLE, VERSATILE TESTING SAFE, RELIABLE OPERATION


Completely self contained for simple turn-key operation Post-test repressurization begins only once a safe
Locally stores up to 20 configurable distillation programs plus temperature has been reached
a cleaning program Safety features with audible alarm and/or system shutdown:
Automation eliminates subjectivity and frees technician from – overtemperature – reciruculating bath failure
time-consuming test steps – abnormal heating power – cabinet doors opened
User-programmable vacuum control inhibits foaming/flooding – temperature probe failure – power failure during test
during vacuum reduction phase; degassing liquid temperature – vacuum circuit failure
can be set to optimize vacuum lowering conditions On-screen service menus for automatic temperature and
Two heating options for fast determination of IBP, even if volume calibrations
sample is unknown Two built-in vacuum measurement verification programs;
Optional PC-based data acquisition with realtime on-screen performs tests on n-Hexadecane at different vacuum levels
plot of distillation curve Expert sales and service from PAC’s worldwide network of
factory trained authorized representatives
VACUUM DISTILLATION
AD1160 Automated Vacuum Distillation Analyzer
SPECIFICATIONS
Ordering Information Documentation & Data Management
AD1160 V acuum Distilla tion Anal
Distillation yzer turn-key system for stand-alone
Analyzer – Video display for real-time monitoring of test progress and results
operation. Alphanumeric keypad with dedicated keys. Delivered complete – 20 program in memory
with a 500ml flask, graduated cylinger, drip tip, foam breaker, clamps, – Graphic printer delivered as standard with listing paper
graphic printer and paper. – Data output: RS 232C (standard) & PC connection (optional)
Optional PC Software Kit for PC-based data acquisition. Windows – PC-based data management: see “Ordering Information”, above
Winwedge™ automatically collects results, transmits them to spread-
sheet format, and plots a distillation curve in real time. Calibration & Diagnostics
– Calibration routines accessible through on-screen menus
Method – Automatic calibration of temperature & sample volume measurements
ASTM D 1160, ISO 6616, JIS K 2254 – Service display with detailed diagnostics information
– Casters allow service engineer to easily access all components
Performance
– Temperature Range: 0 to 700ºC AET Physical
– Pressure Range: 760mm Hg down to 0.1mm Hg – Dimensions: 104cm W x 60cm D x 173cm H (41" W x 24" D x 69" H)
– Accuracy: ±1% at 10 mmHg, ±.01 mmHg at lower pressure; – Weight: 230 kg (507 lbs)
digital pressure regulation – Electrical: 230 and 240 VAC, 10 A, 50/60 Hz
– Vacuum Sensor Probe: select range – External Connections:
• 0 to 1 mmHg • water inlet: tap water, to cool condenser bath
• 0 to 10 mmHg (standard) • nitrogen inlet (optional): speeds repressurization following a test
• 0 to 100 mmHg
– Condenser Bath Range: 25 to 90ºC; stability ±3ºC VA C U U M C U RV E D U R I N G T E S T
Example Target Vacuum: 0.5mm Hg
Operation FROM
– Password protection for key data access 760 mm Hg
Programmed Stabilization Intervals
– Temperature Display: ºC or ºF 152 mm Hg The AD 1160’s unique multi-step vacuum
– Display Resolution: 0.1ºC 1 lowering system inhibits flooding and foaming
– Sample Heating System: according to ASTM D 1160 of difficult and water-containing samples
– Vapor Trap: built-in cold trap with refrigeration system during the vacuum reduction phase. Vacuum is
Hg))
mm Hg

– Receiver Chamber: 25 to 80º; stability ±1ºC; hot-air heated; lowered in up to 6 steps with programmable
PRESSURE ((mm

quick connect graduate receiver level, duration and transition times for each
39 until the desired operating pressure is
– Both condenser bath and receiver chamber temperature have 2
11 reached. Degassing liquid temperature can be
programmable ramp function to optimize heavy products distillation set to optimize vacuum conditions.
4
– Cleaning: special program for cleaning cycle 3
Sample Measurements: TARGET: 0.5
3
– Temperature: PT100 probe; engraved with serial number and 4 6 H E AT I N G P H A S E I N I T I AT E D
delivered with calibration certificate 5
TIME
– Volume: digital measurement; precision stepper drive
Due to our commitment to continual product development, specifications are subject to change without notice.

FOR ADDITIONAL INFORMATION:


AMERICAS:
PAC — PETROLEUM ANALYZER COMPANY L.P.
3234 Pasadena Freeway, Pasadena Texas 77503, USA
Phone: 800.444.TEST [713.590.7260] | Fax: 713.590.7266
sales@paclp.com | www.paclp.com

EUROPE, ASIA, AFRICA, MIDDLE EAST, AUSTRALIA:


INSTRUMENTATION SCIENTIFIQUE DE LABORATOIRE
BP 70285 - VERSON - 14653 CARPIQUET Cedex - FRANCE
Phone: (33) 2 31 26 43 00 | Fax: (33) 2 31 26 62 93
sales@isl-france.com | www.isl-france.com

| |
© Copyright 2002 PAC Petroleum Analyzer Company L.P. F-02-AD1160 Printed in USA

Вам также может понравиться