Вы находитесь на странице: 1из 1

proje / project : yapan / by : sayfa / page :

tarih / date :

Slab Flexure Calculation (ACI 318RM-02)

Section and Material Properties


Concrete C 25
Reinforcement S 420
Width of Section bw = 1400 mm
Height of Section h= 1500 mm d
h
Concrete Cover cc = 50 mm

Distance From Extreme Compression cc


Fiber to the Centroid of Reinforcement d= 1450 mm As

Strength Reduction Factor φ= 0.9


bw
Reinforcement Design
Design Moment Mu = 5165 kNm
Compression Block Factor β1 = 0.85 (a = β1 c)

ϕM n= ϕA s f y (d − a2 )
As f y
Required Reinforcement c= 9900.65 mm2 (5.7.3.2.3)
0 . 85 f ′ β 1 bw
c
¿} ¿
¿ ⇒ A s= ¿
Selected Reinforcement Φ 26 / 125 10203.89 mm2 √
Φ 22 / 125

Reinforcement Limits
Minimum Reinforcement

A s,min  0.0018b w d  3654.00 mm2 √ (7.12.2.1)

Maximum Reinforcement
Steel strain in nominal strength shall not be less than 0.004. (10.3.5)

ε cu c
=
ε cu + ε t d
As f y
c=
0 . 85 f ′ b w
c 44017.86 mm2 √
ρ max =0 . 025
¿} ¿ } ¿
f ′ ε cu
c
¿ A s ,max =ϕ 0 . 85 bw d = ¿
f y ε cu +ε t