PULSE-LORAWAN PULSE-LORAWAN BRIDGE REED SWITCH SPEC

BRIDGE REED SWITCH


Electrical Parameters WIRA ENERGI
ER1850M Lithium Thionyl Chloride Battery
Power Supply / 3XAA Battery

Standby Current 40μA 

TX Transmission Current 126mA


REED SWITCH DAN
RS 485 BRIDGE
MCU Arm 32-bit Cortex -M0+ with MPU 
® ®

Memories 192KB Flash Memory; 20KB RAM; 6KB EEPROM 

Local LCD Display No

Wireless Parameters

Communication Protocol Standard LoRaWAN Class A 

Supporting Frequency 470-510MHz, 863-870MHz, 902-926MHz 


Reed switch Pulse Reading Device is a solution to convert a traditional
Reed-Switch pulse output meters gas meter LoRaWAN wireless node. TX Power Up to +20dBm 

This bridge read the pulse output from the reed switch of the device and RX Sensitivity Down to -137dBm 
transmit to LoRaWAN network.
Channels 8 settable channels with band width of 125KHz 
Built-in Li-SOCl2 battery, it can last up to 5 year.
980bps ~ 3.125Kbps 
The IP67 water proof level casing makes it convenient working in any Data rate Adaptive data rate supporting spreading
out-door environment. factor of SF8 - SF10  

RTC function: each data with time stamps. Listen Before Talk (LBT) Yes

Data cache when wireless connection break down. Number of Data cached when 10
wireless network interrupted
RS485 MODBUS LORA BRIDGE INFRASTRUCTURE

RS485-LORA
Existing Modbus
BRIDGE NODES Slave-Meter
RS485-LORA BRIDGE SPECIFICATION

Wired
RS485 RS485
1. Power Supply : 8-30V DC

2. Application : Indoor
485-LoRa
Bridge Node

3. Standby Current : 20mA

LoRa
4. MCU : Arm® 32-bit Cortex®-M0

5. Frequency : 470-510MHz, 863-870MHz, 902-926MHz

6. TX Power : Up to +20dbm LoRa GateWay

7. RX Sensitivity : Down to -137dBm

TCP/IP
8. Channels : 8 settable channels

9. Data rate : Adaptive data rate

RS485-LoRa bridge is a data channel between traditional devices with RS485 output 10. Listen Before Talk(LBT)
(Modbus Protocol) and LoRa gateway.
11. LoRa Class : Both Class A & Class C LoRa Cloud
RS485 Slave Devices can be any device with RS485 output compliant with the standard Server
Modbus protocol. 12. Power supply isolated & RS485 interface isolated
RS485-LoRa bridge access the registers of RS485 slave devices every interval period set

RESTful

MQTT
13. Compatible with IEC 61000-4-2 (ESD): Air 15kV, Contact 8kV
by system and report the data to LoRaWAN server via gateway.

One LoRa-485 allowed to connect with multi slave devices which also subject to the
number of register to be visited.
Customer