Вы находитесь на странице: 1из 2

140 failsafe series

Current to pressure, (I/P) electronic converter

>> Port size: 1/4” >> Fail-Safe (unit pressure


(ISO G/NPT) falls to zero on signal
>> Advanced electronic failure)
control >> Field replaceable filter
>> Explosion proof/ >> Weatherproof
Intrinsically Safe (IP 66 or Type 4X)
>> Complete electronics >> High performance and
modularity for ease accuracy
of maintenance >> Fast response and
>> Jack Socket for minimal temperature
on-site monitoring effect
>> Large flow capacity
Technical features
Medium: Supply sensitivity: I.P. Rating: Materials:
Oil free, dry media, min filtered to <0,1% of span for full supply IP 66, NEMA Type 4X Body: aluminium and zinc
50 µm; internal in-built filter pressure range Maintenance: diecasting
Output pressure: Port sizes: Modular Electronics and in-built Diaphragms: NBR
0,2 ... 1 bar (3 ... 15 psi) Main ports: G1/4 or 1/4 NPT filter offered as field replaceable Black epoxy powder coating
0,2 ... 2 bar (3 ... 30 psi) Integral gauges: G1/4 or 1/4 NPT parts standard
Supply pressure: Exhaust port: 1/8 NPT Mounting position:
1,2 ... 10,3 bar (18 ... 150 psi) Calibration: Integral bracket allows for
Flow capacity: Independent user adjustment of flat surface or 2” (50 mm) pipe
up to 300 NL/min 0% and 100% calibration points. mounting in any orientation.
Air Consumption: Independent adjustment of tight Designed for mounting with
< 2,5 NL/min at 50% signal shut off point. Adjustable by 57 ... 73 mm pitch U bolts.
Linearity independent: potentiometers up to 20% of Vibration effect:
Typically <0.1%, guaranteed <0.2% output range. Unit is factory Output pressure changes less
Hysteresis & deadband: calibrated to within 1% of span. than 3% for vibration amplitude
Typically <0.1%, guaranteed <0.2% Ambient/Media Temperature: 4 mm 5 ... 15 Hz,
Response time: -40 ... +85 °C (-40 ... +185 °F) 2g15 ... 150 Hz,
<1 second (from 0 ... 90% or Air supply must be dry enough to 1g150 ... 1000 Hz
90 ... 10% of output pressure avoid ice formation at temperatures Leak sensitivity:
into a 0,5 litre load) below +2°C (+35°F). <0,875% of span for up to 3,0
Temperature sensitivity: scfm downstream leakage
Typically <0,06% span/°C between
-40 ... +85°C (-40 ... +185°F)

Technical data - standard models


Symbol Certification Port size Output Conduit Weight Model
pressure Entry (kg) Multi certified units only –
IS/Exd
Cenelec only G1/4 0,2 ... 1 bar M20 x 1,5 2,07 EX14001BJ4LE2
G1/4 3 ... 15 psi M20 x 1,5 2,07 EX14001PJ4LE2
Triple certification / Triple agency 1/4 NPT 0,2 ... 1 bar 1/2 NPT 2,07 EX14001BK4EE1
1/4 NPT 3 ... 15 psi 1/2 NPT 2,07 EX14001PK4EE1
Standard models: conduit entry 1/2 NPT
Options available: conduit entry M20, output pressure monitoring gauge

Electrical parameters
Input Signal 4 ... 20 mA (two wire) Terminal voltage < 6,5 V at 20 mA
Failure Mode Pressure falls to below 15 mbar (0,2 psi) in < 2 sec when input signal fails
Overload Protection 100 mA max overload current
Insulation Resistance > 100 MΩ at 850 V d.c., electrical terminals to chassis
Connections 1/2 NPT or M20; internal terminal block with capacity up to 2,5 mm2 conductor
Span/Zero Independently adjustable tight shut off point adjustable up to 4,5 mA .
Input Impedance The impedance changes with applied current, because it’s terminal voltage remains fairly constant,
therefore 4 mA = approx 1370 Ω; 12 mA = approx 470 Ω; 20 mA = approx 290 Ω

base@basesistemas.com
www.basesistemas.com
976 587 019
Our policy is one of continued research and development. We therefore reserve the right to amend, 08/19
without notice, the specifications given in this document. (2006 - 115e) © 2015 Norgren Ltd. en 6.6.330.01
140 failsafe series
Current to pressure, (I/P) electronic converter

Option selector EX140˙˙˙˙4˙˙˙


Output pressure Substitute Certification Substitute
bar (psi) Triple certification/ triple agency E1
0,2 ... 1 (3 ... 15) 01 Cenelec only (M20x1,5) E2
0,4 ... 2 (6 ... 30) 02 Conduit Entry Substitute
Unit of Pressure Substitute 1/2 NPT E
Bar B M 20 Cenelec Only L
Psi P Ports Substitute
KPa K G1/4 J
Kg/cm2 G 1/4 NPT K

Accessories
Pipe mounting kit

ZZ0150 (2”)

Certification
Certification agency Flame Proof / Intrinsically Non-Incendive others
Explosion Proof Safe

Sira 01ATEX1006 Sira 01ATEX2007X


Ex d IIC T4 Gb Ex ia IIC T4 Ga
(Ta = -20 ... +40°C) Ex ia IIIC Da T95°C
SIRA
Ex d IIB+H2 T5 Gb (Ta = -40 ... +85°C)
(CENELEC ATEX approved)
(Ta = -20 ... +80°C)
Ex d IIB+H2 T6 Gb Ui = 30 V d.c.
(Ta = -20 ... +65°C) Ii = 110 mA
Ex t IIIC T95 °C Db Pi = 0.84 W
II (Ta = -20 ... +85°C) Ci = 6 nF
Umax = 30 V d.c. Li = 100 µH
2GD 1GD

Dust Ingress Protection:


Class II & III, Division 1,
Class I, II & III, Division 1,
Group EFG.
FACTORY MUTUAL Group ABCDEFG.
T6 Ta = 75°C,
T4 Ta = 85°C.
Class I, Division 1, Class I, Division 2, T5 Ta = 85°C.
Group BCD. Group ABCD.
Vmax = 30 V d.c.
T6 Ta = 75°C, T6 Ta = 75°C, Suitable for:
Imax = 110 mA
T5 Ta = 85°C. T5 Ta = 85°C. Class II, III
Division 2,
Ci = 0,006 µF
Group FG,
Li = 100 µH
T6 Ta = 75°C,
T5 Ta = 85°C;

Ex ia, Class I, Division 1, Class I, Division 2,


Group ABCD. Group ABCD.
CSA Class II, Groups EFG, CL III Class II, Division 2,
Class I, Division 1,
Ta = -40 ... +85°C; T4 Group EFG, Class III
Group BCD.
Ta = -40 ... +85°C; T5
Class II, Groups EFG
Vmax = 30 V d.c. Ta = -40 ... +75°C; T6
Class III
Imax = 100 mA
Ta = -40 ... +85°C; T5
Pmax = 0.75 W Ii = 24 mA
Ta = -40 ... +65°C; T6
Ci = 10,5 nF
Li = 100 µH Ci = 6 nF
(30 V d.c. max, 300 Ohms). Li = 100 µH

base@basesistemas.com
www.basesistemas.com
976 587 019
Our policy is one of continued research and development. We therefore reserve the right to amend, 
en 6.6.330.02 without notice, the specifications given in this document. (2006 - 115e) © 2015 Norgren Ltd. 08/19

Вам также может понравиться