Академический Документы
Профессиональный Документы
Культура Документы
Mechanical Page
Components: Review 6
Review of Ring-Torsion Load Cells and Mounts 8
Ring-Torsions Load Cells
– Diaphragmless Ring-Torsion Load Cells 9
– Compact Ring-Torsion Load Cells 13
Mounts for Ring-Torsion Load Cells
– Elastomer Mounts 17
– Compact Mounts 21
– Pendulum Mounts 25
Weighbeams
– Weighbeams DWB 1 ... 5 t 29
– Weighbeam DWB 11.5 t-S 33
– Weighbeams DWB 11.5 t - 25 t 37
– Weighbeams DWB 40 ... 200 t 41
Measuring Eyes 45
Platform Scales 49
Weighing Modules for Hopper Level Measuring Systems 55
Weighing Modules for Road Weighbridges 59
Belt Weighers 61
MULTISTREAM-B Solids Flow Meter 67
MULTISTREAM-G Solids Flow Meters 71
MULTICOR-S Coriolis Mass Flow Meter 75
Weighfeeder DEA 79
Volumetric Feeders, AccuRate Series 83
Electronic
Components: Review 94
DISOMAT E Measuring Amplifier 97
DISOMAT T Weigh Transmitter 101
DISOMAT C Weighing Controller 107
– Limit Value Monitoring 113
– Discharge Scale 115
– Filling Scale 117
– Check Scale 119
DISOMAT F Weight Indicators 121
DISOMAT B Weighing Terminal 127
– Cargo Scale 133
– Crane Scale 135
– Check Scale 137
– Filling Scale 139
– Discharge Scale 143
– Road Weighbridges ZEUS 147
– Platform Scale MILAN 149
DISOMATS Weighing and Automation System 151
– DISOMAT S Herkules for Rail and Road Weighbridges 157
ECOCONT Weighing Electronics 161
INTECONT PLUS for Measuring Systems 165
INTECONT PLUS for Feeding Systems 169
Accessories: Display and Control Units 173
Large Display Units 177
Printers
– DISOPRINT VPR 20150 and DISOPRINT 10 181
– DISOPRINT 330/431 183
Load Cell Cables, Data Cables and Control Cables 185
DKK Cable Box 187
Components for Vibration Machines:
Directional Force Exciter DF 189
Springs for Vibration Machines 193
r Services
Consulting for your application and for installation 195
See price list for prices and terms of
sale and delivery Systems and Package Units for the Process Industries 196
5
Review of mechanical components/
Selection aid
Determination of weight
Hopper Level
Load Cells
Measuring Systems
Ring-torsion load cells are Weighing modules for
suitable for legal-for-trade hopper level measuring
applications and for use in systems. Perfectly tuned
high accuracy processes. components for gravimetric
level measurement of big
hoppers.
r Page 8 ff r Page 55 ff
Weighbeams Road Weighbridges
r Page 59 ff
moments have to be
transferred.
r Page 29 ff
Measuring Eyes
The attractive alternative
where the integration of
conventional weighing
sensors has reached its
limits.
r Page 45 ff
Platform Scales
Legal-for-trade scales in
floor-mounting and dormant
versions.
r Page 49 ff
6
Determination of mass flow
r Page 61 ff r Page 79 ff
AccuRate-Feeder
7
Review of Ring-Torsion Load Cells and Mounts
Diaphragmless Ring-Torsion Load Cells Compact Ring-Torsion Load Cells RTN Mounts for Ring-Torsion Load Cells
Accuracy
C3MI- C3Mi- C4Mi- Elastomer Compact Pendu-
class 0.1% 0.04% C3 C4 C6 0.1% 0.05% C3 C4 C5 lum
7.5 7.5 7.5 Mounts Mounts Mounts
Rated capacity RTW RTV RTK RT4K RTMK RT6K RTN DEM VEN DKM VKN VPN
0.33 t
0.47 t
0.68 t
1,0 t
2.2 t
4.7 t
10 t
15 t
22 t *)
33 t
47 t
68 t
100 t
150 t *)
220 t *)
330 t *)
470 t *)
Rated capacity RTW RTV RTK RT4K RTMK RT6K RTN DEM VEN DKM VKN VPN
0.33 t
0.47 t
0.68 t
1.0 t
2.2 t
4.7 t
10 t
15 t
22 t
33 t
47 t
68 t
100 t
150 t
220 t
330 t
470 t
8
Diaphragmless Ring-Torsion Load Cells RT
9
Rated Capacities: 0.33 t - 15 t Earthing connection
Dimensions
Type Dimensions (mm) F (4 borings)
RT A B C D F K
0.33 F (3 borings)
0.47 75 35 61 66 3xM4/120° 7
0.68
1
2.2 105 43 76 90 4xM6/90° 9.5
4.7
10 14
130 55 89 106 4xM6/90°
15 13
Technical Data
10
Technical Data (as per VDI/VDE 2637 and OIML R60)
Max. utilisation Bamax Bamax = Emax (Bamax = 0,7 Emax for RT4K, RTMK, RT6K for 0,33 t - 0,68 t)
Input resistance Re 4480 q ± 50 q tr
Output resistace Ra 4010 q ± 10 q 4010 q ± 0,5 q tr
Zero signal So ±2% ±1% Cn
Max. supply voltage Usmax 100 V 60 V
Nominal temperature range Btn -10°C to +40°C
Service temperature range Btu -30°C to +80°C, Option to +100°C
Reference temperature tr 22°C
Storage temperature range Bts -50°C to +85°C
Protection class IP68
Cable specification Special silicone RAL 7000 (grey), x 6.5 x 5m, -30°C to +150°C
Colour code black : input + / blue : input -
red : output + / white : output -
green-yellow : screening
Corrosion protection Stainless steel
11
Variants and Order No.
Rated Capacity Order No. Order No. Order No. Order No. Order No. Order No.
t RTW RTV RTK RT4K RTMK RT6K
0.33 D 703642.03 D 703642.02 D 703642.01 D 703642.05 D 703642.05 D 703642.04
0.47 D 703647.03 D 703647.02 D 703647.01 D 703647.05 D 703647.05 D 703647.04*)
0.68 D 703650.03 D 703650.02 D 703650.01 D 703650.05 D 703650.05 D 703650.04
1 D 703630.03**) D 703630.02**) D 703630.01**) D 703630.05**) D 703630.05**) D 703630.04**)
2.2 D 701069.03**) D 701069.02**) D 701069.01**) D 701069.05**) D 701069.05**) D 701069.04**)
4.7 D 703639.03**) D 703639.02**) D 703639.01**) D 703639.05**) D 703639.05**) D 703639.04**)
10 D 703658.03**) D 703658.02**) D 703658.01**) D 703658.05**) D 703658.05**) -
15 D 703901.03**) D 703901.02**) D 703901.01**) D 703901.05**) D 703901.05**) -
Accessories
Elastomer mounts and Compact mounts
Option:
K Protection to EEx ib llC T 6
”intrinsically safe” for use in hazardous
areas, upon request
Order No. D 990001.07
K Variant for service temperature range
of up to 100°C
12
Compact Ring-Torsion Load Cells RTN
13
CE S/N 10049603 Cn = 2.85mV/V
J
E
Admissible static side load Lq = 0.5 (Emax- 0.8 Lz), but no higher than Lqmax = 0.3 Emax; Emax = rated capacity;
Lz = load in measuring direction
14
Technical Data
Combined error Fcomb 0.1% 0.05% 0.02% 0.015% 0.01% 0.013% 0.013% Cn
Temperature coefficient TK0 ±0.1%/10K ±0.03%/10K ±0.007%/10K ±0.0058%/10K ±0.0058%/10K ±0.0058%/10K ±0.0058%/10K Cn in Btn
of zero signal ±0.1%/10K ±0.05%/10K ±0.02 %/10K ±0.02 %/10K ±0.02 %/10K ±0.02 %/10K ±0.02 %/10K Cn in Btu
Temperature coefficient TKc ±0.1%/10K ±0.05%/10K ±0.008%/10K ±0.007%/10K ±0.0062%/10K ±0.007%/10K ±0.007%/10K Cn in Btn
of characteristic value ±0.1%/10K ±0.07%/10K ±0.02 %/10K ±0.02 %/10K ±0.02 %/10K ±0.02 %/10K ±0.02 %/10K Cn in Btu
Protection class IP 68
Cable specification Special silicone RAL 7000 (grey) ∅ 6.5, -30°C to +150°C,
Length 5 m for RTN 1-15 t and RTN 150-470 t
Length 15 m for RTN 22-100 t
15
Order No.
Order No.
Example for ordering: Rated Capacity 47t, accuracy class C5: Variant RTN 47t C5 – Option:
Order No.: D 724782.10 K Variant for service temperature range
*) Available from April 1998 and later of up to 110°C
**) Available from January 1998 and later
Acessories:
Elastomer mounts, Compact mounts, and
Pendulum mounts
16
Elastomer Mounts for Ring-Torsion Load Cells
K Self-centering capability
K Dynamic load damping
properties
K Minimal reaction to side forces
K Simple, rugged, and flat design
K High resistance to environmen-
tal influences and chemicals
K Insensitivity to inclined
position of connecting
structure up to 0.6° = 10 mm/m
K Legal-for-trade
K Easy installation
K Maintenance-free
17
Elastomer Mounts DEM 0.33 t – 4.7 t for RTK/V/W-Load Cells
– Elastomer is installed above the contact
plate Admissible play ± 2 mm
Shims
– Contact plate is bolted or fastened to (5 x 1 mm)
the connecting structure with two straps Elastomer
fitted on sides
– Height adjustment (max. 5 mm) via Contact plate
shims
– Alignment through shifting the base Load cell
plate secured by bolted or fastened
fixing pieces
Base plate
Fixing piece
18
Elastomer Mount DEM 10 t – 15 t for RTK/V/W-Load Cells
Admissible play ± 3 mm – Elastomer is installed below the load
Shims cell
(5 x 1 mm)
– Contact plate is secured by a centering
Centering piece ring bolted onto the supporting
structure
Contact plate
– Height adjustment (max. 5 mm) via
Load cell shims
Base plate
– Alignment through shifting the base
plate secured by bolted or fastened
straps
Elastomer
19
Technical Data
20
Compact Mounts for Ring-Torsion Load Cells
21
Compact Mount DKM 0.33 t – 0.68 t for RTK/V/W Load Cells Compact Mount DKM 1.0 t – 4.7 t
Top and bottom plate can be
welded during installation. Prior
to welding, remove load cell.
Shims (5 x 1 m)
1 mm play
For M12 Screws
with washers DIN 125
- by user -
K
Type Rated capacity C D E F G H L 1 mm play
x
DKM t mm mm mm mm mm mm mm
0.33 - 0.68 0.33 t - 0.68 t 195 120 45 65 10 95 12 M8 1 mm play
22
Compact Mount DKM 10 t - 15 t for RTK/V/W Load Cells
*) Available from April 1998 and later **) Available from Januar 1998 and later
23
Technical Data
Variant DKM VKN
Rated capacity load: 0.33 ... 15 t 1 ... 33 t
Weight: DKM 0.33 - 0.68 8,5 kg VKN 1 - 4.7 12.3 kg
(including load cell) DKM 1.0 - 4.7 26 kg VKN 10 - 22 19 kg
DKM 10 - 15 34 kg VKN 22 39 kg
VKN 33 42 kg
Material
- Metal parts: Stainless steel DKM 0.33 - 15 t and VKN 1 - 15 t
St 37 (galvanized) VKN 22 - 33 t
- Elastomer: Neoprene (chlorine butadiene rubber)
Option: Viton (fluorinated rubber FKM)
(available upon request) SBR (styrene butadiene rubber)
EPDM (ethylene propylene diene rubber)
Height adjustment: 5 mm
Deflection: Approx. 0.8 mm at rated capacity
Options: Heat insulation plates, spray water protection,
welding plates
24
Pendulum Mount VPN for Compact Ring-Torsion Load Cell RTN
25
Dimensions
Admissible play ± M mm K Pressure plate is secured through a
centering piece screwed onto the
Height adjustment shims connecting structure.
K Height is adjusted (max. 5 mm) with
shims.
Centering piece
max. 5
Load cell
Foot plate
Earthing
Centering pin x 25h9 x 20
connection
Base plate, e.g. from St37
Circular L/C
mounting area
Uhg
Earthing connection
V-0,2
Material X20CrNi17V
Min. x B + 30
26
Type Rated Dimensions (mm)
Capacity
VPN t A B C D E F G H1 H2 K L M N O U V
100 100 100 150 160 10 129 180 140 371 331 130 45 8 M16x30 40 25 6
Technical Data
(Load Cells are not included) *) Available from April 1998 and later
27
Notes:
28
Weighbeams DWB 1 ... 5 t
29
Mounting dimensions
A B C D E
Variants F G
mm mm mm mm mm
Operating principle
Load L2 Load L2
Weighbeam
Supports
30
Technical Data
Rated capacity Ln 1t 5t 5t
Limit load L l
2t 10 t 10 t
Rupture load Ld 4t 20 t 20 t
Reference temperature t r
+ 22°C
Temperature coeffizient of characteristic value TK c± 0.07% / 10K (in case of HD-quality: ± 0.03% / 10K) C n in B tu
Dead weight m e
3 kg 10 kg 18 kg
Surface electro-galvanized
Protection class IP 67
DWB 1 t D 507 699.01 High-quality (HD) Available on Elastomer mounts for 6250.340
design for extremely request DMB 5 t and
DWB 5 t D 507 728.01 high accuracies DWB 5 t long
x 65 mm x 22 mm
DWB 5 t long D 703 627.03
x 76 mm x 24 mm 6250.341
31
Notes:
32
Weighbeam DWB 11.5 t - S
K High accuracy
K Hermetically sealed, proteced
to IP 67 by laser welding
K Easy and economic mounting
by permanent bolting to the
connecting structure
K Transmission of extreme
interfering forces and
moments with minimal effects
on measurement values
K Designed for high
temperatures and rugged
environments
K Suitable for construction of
maintenance-free scales
33
Mounting dimensions
Operating principle
Load L
Load L
Lateral load
Lq
Weighbeam
Supports
34
Technical Data
Reference temperature t r
+ 22°C
Dead weight m e
15 kg
35
Quality requirements for connecting surfaces
Weighbeam
36
Weighbeams DWB 11.5t - 25 t
37
Mounting dimensions
Operating principle
Load L Load L
Lateral load
Lq
Weighbeam
Supports
38
Technical Data
Temperature coefficient of zero value TK o ± 0.1% / 10K (in case of HD-quality: ± 0.05%) C n in B tu
Temperature coefficient of characteristic value TK c ± 0.07% / 10K (in case of HD-quality: ± 0.05%) C n in B tu
Dead weight me 18 kg 18 kg 18 kg
Surface electro-galvanized
Protection class IP 67
39
Quality requirements for connecting surfaces
Weighbeam
40
Weighbeams DWB 40 ... 200 t
41
Mounting dimensions
DWB 40 t
80 (Width of load application)
ca. 150
ca. 150
Variant A B C D E F G H I K L M N P Q R S T
mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm
DWB 50 t 450 120 130 105 298 398 68 75 40 80 110 26 M20x30 19 31 26 25.5 0
DWB 100 t 500 140 143 118 336 444 80 90 44 90 130 30 M24x36 25.5 36 26 28.5 0
DWB 150 t 560 160 158 133 372 500 94 102 44 90 150 33 M24x36 31.5 43 26 32 0
DWB 200 t 620 180 175 150 400 560 114 110 44 90 160 33 M24x40 41.5 46 26 32 40
42
Operating principle
Load L Load L
Lateral load
Lq
Weighbeam
Supports
Load L Load L
Lateral load
Lq
Weighbeam
Supports
Technical Data
DWB 40t DWB 50t DWB 100t DWB 150t DWB 200t Reference
Rated capacity Ln 40 t 50 t 100 t 150 t 200 t
Limit load (with L q=0.15xL n) L l
80 t 100 t 175 t 240 t 300 t
Rupture load (with L q=0.15xL n) Ld 160 t 200 t 350 t 480 t 600 t
Max. admissible lateral load L qmax 40 t 50 t 85 t 120 t 150 t
Nominal characteristic value C n
0.95 mV/V 1.08 mV/V 1.38 mV/V 1.57 mV/V 1.63 mV/V L n
Temperature coefficient
TK ± 0.05% / 10K C n in B
of characteristic value c tu
Dead weight m e
39 kg 40 kg 55 kg 85 kg 120 kg
Surface electro-galvanized
Protection class IP 67
Cable specification Silicone RAL 7000 (grey) x 6.5 mm x 15 m - 30°C to + 150°C
43
Quality requirements for connecting surfaces
DWB 40 t
Weighbeam
Weighbeam
44
Measuring Eye, Type DMA
45
There are two types of measuring eyes: Typical applications
K DMA-V: Standard measuring eye with
a complete strain gauge full
bridge
K DMA-H: Special variant with strain
gauge half bridge (if more
than 4 measuring eyes/
system are used)
Normal force
measurement:
Section A-A
Lateral force
measurement:
46
Technical Data
The technical data apply to one DMA-V measuring eye or a pair of DMA-H measuring eyes (two DMA-H measuring eyes combined
to form a Wheatstone bridge).
Sensitivity at required
Cn ≥ 0.3 mV/V
rated stress
System accuracies and switching accuracies depend on several factors, e.g. vessel geometry, installation site, nature of measuring
task. Typically, system accuracies of ± 0.5 % for lateral force measurement or ± 1.5 % for normal force measurement can be
reached, with achievable switching accuracies for preset filling levels (setpoints) being approx. ± 0.2 % (each in relation to full scale).
These accuracies require highly qualified engineering and proper and workmanlike installation.
We offer measuring system layout as a service, i.e., we offer to determine the accuracies which are to be expected for the actual
geometry of your application and which we warrant, provided that Schenck supplies the components and that mounting of the
measuring eyes is carried out by Schenck-authorized personnel.
47
Projecting notes
K To determine whether an existing
vessel can be retrofitted with
SCHENCK measuring eyes, calculate
rated stress as under:
DMA-V
Measuring eye with strain gauge full bridge D 705 336.01
DMA-V-ex
Measuring eye with strain gauge full bridge
for use in hazardous area D 724 987.02
DMA-H
Measuring eye with strain gauge half bridge D 705 226.01
DMA-H-ex
Measuring eye with strain gauge half bridge
for use in hazardous area D 724 988.01
Mounting kit
for pressing-in measuring eyes D 705 046.01
DKK69/DMA
Cable junction box for connection of
up to 8 measuring eyes D 727 243.01
Closing device to protect measuring
eyes against mechanical damage D 705 968.01
Manual, German D 707 200.01
Manual, English D 707 204.01
48
Platform Scales, DVS Type
K Minimum headroom
K Legal-for-trade
K Option: Calibration ex factory
up to 3000 d
K Rugged and maintenance-free
K Low price
K Easy to clean (platform
removable)
K Corrosion protection: St 37
varnished or VA tanned
K All cavities in the frame
construction are sealed and
thus protected from dirt or
condenser water
49
In addition to the weighing platform, we
can supply
- a foundation frame
or
- a dirt channel frame,
both as options.
These mechanical components are
available either in
K St 37, varnished (to RAL 7015, slate
grey)
K Stainless steel 1.4301, tanned.
Floor-mounted scale
50
Variants
Platform Scale DVS-2
Variant Capacity Possible Preload* Weighing Range Division
When ordering a DVS-2, the following
features can be combined: 1 1500 kg 1000 kg 2-200 kg 0.1 kg
K Material
– St. 37, varnished (to RAL 7015, 2 1500 kg 900 kg 2-300 kg 0.1 kg
slate grey)
3 1500 kg 700 kg 4-500 kg 0.2 kg
– Stainless steel 1.4301, tanned.
K Platform size / weight 4 1500 kg 600 kg 4-600 kg 0.2 kg
– 750 x 750 mm approx. 65 kg
– 1000 x 1000 mm approx. 100 kg 5 2000 kg 500 kg 10-1000 kg 0.5 kg
K Headroom 80 mm
6 2000 kg 200 kg 10-1500 kg 0.5 kg
K For capacity, possible preload,
weighing range and division, see table * Maximum admissible weight of platform and superstructures
on the right.
Platform Scale DVS-4 Variant Capacity Possible Preload* Weighing Range Division
When ordering a DVS-4, the following
features can be combined: 1 4000 kg 2000 kg 10-1000 kg 0.5 kg
K Material
– St. 37, varnished (to RAL 7015, 2 4000 kg 1500 kg 10-1500 kg 0.5 kg
slate grey)
3 4000 kg 2000 kg 20-2000 kg 1.0 kg
– Stainless steel 1.4301, tanned.
K Platform size / weight 4 4000 kg 1500 kg 20-2000 kg 1.0 kg
– 1250 x 1000 mm approx. 169 kg
5 4000 kg 1000 kg 20-3000 kg 1.0 kg
– 1500 x 1250 mm approx. 227 kg
– 1500 x 1500 mm approx. 265 kg * Maximum admissible weight of platform and superstructures
– 2000 x 1500 mm approx. 365 kg
K Headroom 100 mm
K For capacity, possible preload,
weighing range and division, see table
on the right.
51
Dirt Channel Frame Option Construction Prerequisites
For dimensions, see Spec Sheet DDP Foundation must correspond to carrying
8834. loads (see Foundation Frame Technical
Data Sheet). If platform scale is installed
outdoors or where spray water is to be
Foundation Frame Option
expected, some sort of drainage should
Application be provided.
Foundation frame enables platform scales Foundation depth and construction
to be mounted in pits in simple and form- depend on load to be applied and local
locking fashion. conditions.
When ordering a foundation frame or dirt
Construction channel frame, the following features can
Foundation frame consists of an angular be combined:
section with anchor plate.
K Material
Functions – St. 37, varnished (to RAL 7015,
slate grey)
Foundation frame ensures continuous
(not available with dirt channel
transition from bottom plate to weighing
frame)
platform and prevents side-travel of
bottom edge. – Stainless steel 1.4301, tanned
K Platform size/weight Foundation frame
– 750 x 750 mm 12.5 kg
– 1000 x 1000 mm 16.5 kg
– 1250 x 1000 mm 18.5 kg
– 1500 x 1250 mm 22.0 kg
– 1500 x 1500 mm 24.5 kg
– 2000 x 1500 mm 29.5 kg
52
Foundation Frame Dimensions
Technical Data
Support pressure of feet (P1) at
L50x50x5
2 000 kg capacity 8 000 N
4 000 kg capacity 16 000 N Anchor
min 70
Anchor recess Floor top edge
53
Variants and Order Numbers Dirt Channel Frame
DVS-2* Dimensions Stainless Steel,
Tanned
Dimensions Max.Weighing ST 37, Stainless Steel
Range Varnished Tanned 750 x 750 E 056 977.07
750 x 750 600 kg E 056 974.01 E 056 974.19 1000 x 1000 E 056 977.08
1000 x 1000 600 kg E 056 974.02 E 056 974.20 1250 x 1000 E 056 977.09
750 x 750 1500 kg E 056 974.04 E 056 974.22 1500 x 1250 E 056 977.10
1000 x 1000 1500 kg E 056 974.05 E 056 974.23 1500 x 1500 E 056 977.11
2000 x 1500 E 056 977.12
54
Weighing Modules for Hopper Level Measuring Systems
55
Modules with DMA Measuring-Eyes
Mounting on vertical supports:
Normal force
measurement: Module with 4 measuring eyes DMA-V
and 1 cable junction box DKK 69/DMA
Mounting on
vertical silo Mounting on horizontal supports
supports (preferred solution)
Module with 8 measuring eyes DMA-H
and 1 cable junction box DKK 69/DMA
If modules with measuring eyes are used,
there is no dependance on hopper load.
System accuracies of +/- 0.5 % with
Required space L ≥ 2.5 × H lateral force measurement or +/- 1.5 %
with normal force measurement can be
realized. However, these values require
Section A-A
qualified engineering and mounting.
Please see our offer on page 195.
Planning Help:
If you wish to find out whether your plant is suitable for use of SCHENCK measuring
Lateral force eyes, calculate the occurring stress using the following formula:
measurement:
Mounting on
horizontal silo Normal force measurement (required stress σ ≥ 30 N/mm2):
supports
(Mass of max. hopper level in [kg]) x 10
2
Stress σ in [N/mm ] = ________________________________________
(Number of supports) x
2
(Support cross-section area in [mm ])
56
Modules with DMA Measuring Eyes Order No. Modules with 4 Ring-Torsion Load Cells Order No.
57
For details, see the respective component descriptions:
Measuring Eyes DMA page 45 ff
RTN Load Cells page 13 ff
RTW, RTK Load Cells page 9 ff
Compact Mounts page 21 ff
Cable Junction Box page 187 ff
58
Weighing Modules for Road Weighbridges
59
Kits For Weighing Ranges Up To 22 t Order Number Option Order Number
VSK 4 - 22 (4 load cells) D 708640.01**) Additional bumper check plate VSF 001 2460.272
- 4 load cells RTN 22t, accuracy class C3
- 4 elastomer mounts VEN 22
- 1 cable junction box DKK 5 D 708640.11*) Accessories
- 8 bumper checks VSF 001
Special measuring cable for
VSK 6 - 22 (6 load cells) D 708640.02**) interconnection of cable junction
- 6 load cells RTN 22t, accuracy class C3 box and weighing electronics page 185 ff
- 6 elastomer mounts VEN 22
- 2 cable junction boxes DKK 5 D 708640.12*) For details of individual components, please see
- 8 bumper checks VSF 001
Compact load cells page 13 ff
Elastomer mounts page 17 ff
Cable junction boxes page 187 ff
Kits For Weighing Ranges Up To 33 t Order Number Upon request, all modules can be supplied as variants suitable
for hazardous areas.
VSK 4 - 33 (4 load cells) D 708640.03
- 4 load cells RTN 33t, accuracy class C3
- 4 elastomer mounts VEN 33
- 1 cable junction box DKK 5
- 8 bumper checks VSF 001 Bumper Check Plate VSF 001
VSK 6 - 33 (6 load cells) D 708640.04 Dimensions (mm)
- 6 load cells RTN 33t, accuracy class C3
- 6 elastomer mounts VEN 33
- 2 cable junction boxes DKK 5
- 8 bumper checks VSF 001
*) Deliverable from April 1998 onwards with elastomer mount VEN 10-22
**) Deliverable until March 1998 with elastomer mount VEN 22
Basic electronics for display, printing and transfer DISOMAT F Weight Indicator
of weight values See page 121 ff
Weighing terminal with extended functionality and DISOMAT B ZEUS Road Weighbridge
higher operating convenience See page 147 ff
Compact control and evaluation unit with high functionality, DISOMAT S HERKULES Road Weighbridge
memory capacity and operating convenience See page 157 ff
Connecting road weighbridges Upon request
Utilization of PC functionality PC-based systems, upon request
60
Belt Weighers
61
Dimensions (mm)
800 L≤ L1250
800 ≤ 1250 800 ≤LL1250
800 ≤ 1250 800 ≤L L1250
≤ 1250
55
150
Min 150
163.5
120
335
Max 275
Min 100
500 200-300
B
Option
Min 100 / Max 150
120
31 111 90
Min 50 / Max 90
800≤ LL ≤1250
800 1250 800≤ LL ≤1250
800 1250 ≤ LL≤ 1250
800
800
450
Min 150
Max 390
Min 180
Option
55
B 200-300 824.5
C
A
280 280
A
62
Dimensions (mm)
E (Min)
513 225
Max 470
Min 210
200-300 Option
D D
Two weighing stations side by B B
side for belt widths of 1600 mm
and more
C C
Two BMP weighing stations arranged one after the other to achieve higher accuracies
(Weighing station dimensions are the same as those of the BMP weighing stations)
63
Technical Data
Accuracy
Variant without speed measurement system Flow Rates Weight Belt Speed Belt Rise
only achievable at constant speed
± 1.0% to ca.
BEM ≈ 60 kg
of nominal flow rate 4,000 t/h
± 0.5%
of nominal flow rate to ca.
BEP ≈ 100 kg
Single Belt ± 1.0% 6,000 t/h
Weighers of actual flow rate
± 0.5%
of nominal flow rate to ca.
BED ≈ 300 kg ~ 20°
± 1.0% 15,000 t/h to. ca. 6 m/s
(No relative material
of actual flow rate (Preferential range))
movement)
± 0.25% to ca.
2 BMP ≈ 400 kg
of actual flow rate 15,000 t/h
K Belt speed
.......................................[m/s]
K Accuracy
........................................[%]
Nominal flow rate ( )
Actual flow rate ( )
64
Variant Order-Number Documentation Order-Number
German D707377.01
Options Order-Number English D707378.01
French D707379.01
FGA 24 A F010296.01
Speed measurement system
NAMUR switch with perforated disc On set of documentation is supplied. Should you need additional
copies, please order separately. Remember to indicate desired
FGA 20 RSE F020401.01 language version.
Speed measurement system
Friction wheel with rocker and support
FGA 20 RSE-VA F020401.02
Speed measurement system
Friction wheel with rocker and support
VA version
65
Notes:
66
MULTISTREAM-B Solids Flow Meter
67
Dimensions (mm)
600
Electronic housing
Elektronikgehuse
600
600
600
1400
110
1400
110
1400
110
110
250
1400
250
180
180
Ansicht ‘Auslauf’
x 200
200
Top View
190
190 180
180
°
x 45
8
0
295 295
600
600
0
20
22
22
x
202
202 695
695
68
Technical Data
MULTISTREAM-B80 Solids Flow Meters
Flow rate min. 1 t/h - max. 80 m3/h (100 t/h)
Accuracy ± 2% of nominal flow rate
Measuring range 1:5
Operating pressure -25 mbar to 50 mbar
Inlet/outlet flange dimensions (DIN) 200 mm / 200 mm
Weight 50 kg
Ambient temperature - 30° to + 60°C
Material temperature max. 70°C
Bulk density min. 0.4 t/m3
Grain size max. 10 mm (single grain up to 30 mm)
Flow properties non-packing, pulverized to granular
69
Variant Order No. Documentation Order No.
MULTISTREAM-B80, MULTISTREAM-B80
Solids Flow Meter, max. 80 m3/h F018320.01 Service Manual
German D707380.01
English D707381.01
French D707382.01
70
MULTISTREAM-G Solids Flow Meters
71
Dimensions (mm)
MULTISTREAM-G
Solids Flow Meters tc.
~550 ecke, e
e, Schn .
Luftrinnlide, screw, ..
Air s
560
1360
560
CableKlemmkasten
junction box
1360
600
600
Wgezelle
Wägezelle
Load cell
F G
G 400/750 G 1250
60 760 60
25
200 15 15 200 15
60
60
15
15
15
150
150
H
J
H
K
L
K
M
L
60
60
25
15
130
15
24 4 x 208 24
230 230
72
Technical Data
MULTISTREAM Solids Flow Meters
G 400 G 750 G 1250
3 3
Flow rate min. 4 t/h - max. 400 m /h min. 16 t/h - max. 750 m /h min. 40 t/h - max. 1250 m3/h
(max. 1000 t/h) (max. 1000 t/h) (max. 1000 t/h]
Accuracy ± 2% of nominal flow rate
Measuring range 1:5
Weight 155 kg 250 kg 390 kg
Ambient temperature -30°C to +60°C
Material temperature max. 100° (optional 200°) Celsius
Bulk density min. 0,4 t/m3
Grain size max. 10 mm (single grain up to 30 mm)
Flow properties non-sticky, pulverized to granular
73
Variant Order Number Documentation Order Number
74
MULTICOR-S Coriolis Mass Flow Meter
75
Dimensions (mm)
Top View
25°
Inlet View
Inlet View
DIN 24145
8 x x 11.5
76
Technical Data
S 40 S 80
Flow rate min. 0.5 t/h - max. 40 m3/h (20 t/h) min. 2 t/h - max. 80 m3/h (60 t/h)
Accuracy ± 0.5 % of actual flow rate
(± 1.0 % of actual flow rate at 0.5 t/h - 2 t/h)
Measuring range 1 : 10
Operating pressure -2 mbar to 20 mbar
Pressure variations ± 5 mbar
Inlet dimensions (inside diameter) x 140 mm (DIN 2501 DN 125) x 200 mm (DIN 24145)
Outlet connecting dimensions x 356 mm
Weight 180 kg 230 kg
Ambient temperature -30° to +50° Celsius
Material temperature max. 130° Celsius
Material density min. density 0.3 t/m3
Grain size max. 5 mm (single grain up to max. x 30 mm)
Flow properties non-sticky, pulverized to granular
77
Variant Order Number Documentation Order Number
MULTICOR-S40 MULTICOR-S40/S80
Coriolis Mass Flow Meter for Operating/Service Manual and
0.5 t/h - 10 t/h, 50 Hz drive F 014 960.05 Transport Instructions
0.5 t/h - 10 t/h, 60 Hz drive F 914 960.06
MULTICOR-S40 German D 707 386.01
Coriolis Mass Flow Meter for English D 707 387.01
2 t/h - 20 t/h, 50 Hz drive F 014 960.07 French D 707 388.01
2 t/h - 20 t/h, 60 Hz drive F 014 960.08
MULTICOR-S80 One set of documentation is supplied as standard. Should you
Coriolis Mass Flow Meter for wish additional copies to be supplied, please order separately.
2 t/h - 60 t/h, 50 Hz drive F 014 960.09 Please remember to indicate desired language version.
2 t/h - 60 t/h, 60 Hz drive F 014 960.10
Extensive display, operating and control capabilities for scales, or scale groups,
including peripherals; convenient integration into existing process control systems Upon request
78
Weighfeeder DEA
79
Dimensions (mm)
Weighfeeder
DEA 300/600
523/692
80
Technical Data
Gravimetric feed rate 100 kg/h - 18.000 kg/h 200 kg/h - 38.000 kg/h
AC drive
0.5 kW 0.5 kW
(400 V / 3-phase / 50 or 60 Hz)
Order Data
To be able to process your order smoothly
Material Data
and quickly, please remember to indicate
order number and data shown on the Bulk density [t/m3] : min._______ max. ________
right when placing your order. Material temperature [° C] :
Material :
Feed Rate
Gravimetric feed rate [t/h] : min._______ max. ________
Network Frequency
Network frequency : ( ) 50 Hz ( ) 60 Hz
Belt Change
Direction of travel : ( ) left ( ) right
81
Variant Order No. Documentation Order No.
Measuring, control and supervisory electronics for single applications INTECONT PLUS
for feeding systems
Scale monitoring, operating and controlling;
Easy integration into existing process control systems. See page 169 ff
Measuring, control and supervisory electronics for complete scale groups MULTICONT
Comprehensive display, operating and control capabilities for scales and scale groups
including scale environment; convenient into existing process control systems Upon request
82
Volumetric Feeders, AccuRate Series
83
Dimensions (mm)
AccuRate Feeder
Top View
4 x M8
B
L
C
19-41
D G
F E
H L
AccuRate Feeder
Fitted With Extension Hopper
M P
AccuRate Feeder
Free Standing Hopper
U U
Z Z
84
Dimensions
85
Technical Data
AccuRate Feeders
Drive Design
AC drive m
DC drive m
86
AccuRate Feeders - Series 300
Feed Unit/Tube Options (length and size to be indicated in your order) Order Number
Additional discharge unit (helix and nozzle)
for extension of feed rate range in particular standard length (Series 300: 102 mm); Upon request
diameter in accordance with desired feed rate range extension
Helix and nozzle extension, to max. 300 mm F021551.02
stainless steel; length (from feeder front) to be specified in your order
Nozzle support with Series 300, we recommend min. 300mm length F021552.02
Side nozzle discharge, for flushing material, to improve feeding constancy F021553.02
Outlet shut-off gate, pneumatically actuated, suitable for batching F021554.02
Vertical discharge head of stainless steel (in place of vinyl) F021555.02
87
AccuRate Feeders - Series 600
Feed Unit/Tube Options (length and size to be indicated in your order) Order Number
Additional discharge unit (helix and nozzle)
for extension of feed rate range in particular standard length (Series 600: 178 mm); Upon request
diameter in accordance with desired feed rate range extension
Helix and nozzle extension, to max. 1200 mm F021564.03
stainless steel; length (from feeder front) to be specified in your order
Nozzle support with Series 600, we recommend min. 400mm length F021565.03
Side nozzle discharge, for flushing material, to improve feeding constancy F021566.03
Outlet shut-off gate, pneumatically actuated, suitable for batching F021567.03
Vertical discharge head of stainless steel (in place of vinyl) F021568.03
88
AccuRate Feeders - Series 900
Feed Unit/Tube Options (length and size to be indicated in your order) Order Number
Additional discharge unit (helix and nozzle)
for extension of feed rate range in particular standard length (Series 900: 305 mm); Upon request
diameter in accordance with desired feed rate extension
Helix and nozzle extension, to max. 1200 mm F021576.04
stainless steel; length (from feeder front) to be specified in your order
Nozzle support with Series 900, we recommend min. 400mm length F021577.04
Side nozzle discharge, for flushing material, to improve feeding constancy F021578.04
Outlet shut-off gate, pneumatically actuated, suitable for batching F021579.04
Vertical discharge head of stainless steel (in place of vinyl) F021580.04
89
AccuRate Feeders - Series 1200
Feed Unit/Tube Options (length and size to be indicated in your order) Order Number
Additional discharge unit (helix and nozzle)
for extension of feed rate range in particular standard length (Series 1200: 305 mm);
diameter in accordance with desired feed rate extension Upon request
Helix and nozzle extension, to max. 1200 mm
stainless steel; length (from feeder front) to be specified in your order F021588.05
Nozzle support with Series 1200, we recommend min. 400 mm length F021589.05
Side nozzle discharge, for flushing material, to improve feeding constancy F021590.05
Outlet shut-off gate, pneumatically actuated, suitable for batching F021591.05
Vertical discharge head of stainless steel (in place of vinyl) F021592.05
90
AccuRate Feeders - Series 300/600/900/1200 - Options
Series 900 Model 951l 140 liters; fitted onto feeder F021599.04
Model 953l 280 liters; fitted onto feeder F021601.04
Model 961l 425 liters; fitted onto feeder F021603.04
Model 955l 560 liters; free standing F021605.04
Model 957l 1420 liters; free standing F021607.04
Series 1200 Model 1251l 140 liters; fitted onto feeder F021600.05
Model 1253l 280 liters; fitted onto feeder F021602.05
Model 1261l 425 liters; fitted onto feeder F021604.05
Model 1255l 560 liters; free standing F021606.05
Model 1257l 1420 liters; free standing F021608.05
One set of documentation (German and English) and safety guidelines in all European languages (conform to CE) are supplied.
Should you need further copies, please order separately. Remember to indicate desired language version.
91
Notes:
92
Review of electronic components/
Selection aid
DISOMAT E DISOMAT S
Low-price basic solution for Complex weighing and
weighing and monitoring automation tasks made
tasks. easy.
r Page 161 ff
many weighing and feeding
applications.
INTECONT PLUS
DISOMAT E DISOMAT T DISOMAT C DISOMAT F DISOMAT B DISOMAT S ECOCONT
measuring / feeding
Typical applications
Weight monitoring X X X
Cargo scale X X X
Check scale X X
X
Road weighbridge X X
in connection with a PC
Rail weighbridge
X
static + dynamic
Crane scale X X
Discontinuous totalizing
X X
autom. weighing device
Automatic gravimetric
X X X
filling machine
Single-ingredient feed
control (filling/discharge X X X
scale)
Multi-ingredient feed
X
control
Application-specific
X
programming
Ex-protective circuitry X X X X X X
Belt weighers X X
Weighfeeders DEA X
Handling
Parametrization via PC
Setup/calibration Keyboard/PC via PC Keyboard/PC Keyboard/PC Keyboard/PC Keyboard/PC Keyboard/PC (automatic calibration
program)
Communication
Analog outputs 1 1 1 / 1 2 1 1 2
Option: 4 inputs /
2 inputs / 4 inputs / 2 inputs / 2 inputs / 3 inputs / 3 inputs /
Binary inputs/outputs 3 inputs / 4 outputs 4 relay outputs 256 inputs/outputs
3 outputs 4 relay outputs 4 relay outputs 3 outputs 7 outputs 8 outputs
(Optocoupling) (option: 6)
1 + 1 service 4 + 1 service
Serial Interfaces 1 2 2 3 1 2 2
interface interface
Printer connection X X X X X
Technical
characteristics
Memory card X
95
Notes:
96
DISOMAT E Measuring Amplifier
97
Dimensions (mm)
TS 35
133.6
196.5
max
max 200
200 22
51
73.5
170.5
170.5
110
91
260
240
98
DISOMAT E in Use (Hopper level measurement with load cells or measuring eyes)
99
DISOMAT E, basic version FEN 0100 - Technical Data Options
Display for Display 7-segment, 4-digit Field housing Housing for installation of DISOMAT E
parametrization 3 LEDs for DISOMAT E (IP 65 / Nema 4)
260 mm x 160 mm x 91 mm
Power supply 24 VDC +30% / –20%
Power consumption 10 W Field housing Housing (IP 65) with 230 V / 24 V
with power power supply unit
Ambient Operating temperature (-25°) 0°- 50°C supply unit 160 mm x 160 mm x 90 mm
conditions According to CE regulations (115 V upon request)
100
DISOMAT T Weigh Transmitter
Application Equipment
DISOMAT T weigh transmitter is used The main board DWT 100 comprises DISOMAT T is supplied as plug-in
as weight value transducer particularly the following functions: board, or mounted in a 19" rack or a
for weight value monitoring and K Measuring circuit with A/D field housing.
hopper level measurement. Hopper converter
level measurements with accuracies
K 4 relay outputs with safe isolation
in the percent range are realized by
easy-to-mount SCHENCK Measuring K 1 analog output
Eyes, type DMA. K Service interface
Highly accurate weight acquisition K EDP interface (various protocols)
with accuracies in the pars promille Expansion boards provide additional
range is made possible by RT load functions:
cells. K DISONET interface (DISOMAT
Equipped with analog output and network) and 4 input contacts via
serial interface, it is suitable for all DISONET Board DDN V100,
scales connected to higher level EDP K PROFIBUS interface via PROFI-
or PLC systems that are not operated BUS Board DPB V100,
locally.
K INTERBUS-S interface via INTER-
BUS-S Board BIB V100.
101
Functions An on-line help function assists the DISOPLAN T user by providing comprehensive
In DISOMAT T, various EDP protocols are information on all important menu items.
implemented. In addition, it can be
integrated into common field bus systems
(J-BUS, PROFIBUS, INTERBUS-S).
Four relay outputs serve for limit value
monitoring and output of status reports.
Safety in critical applications is ensured
by the safe isolation of outputs and EMC
immunity.
All dialogs for configuration, calibration,
and diagnosis are conveniently conducted
from a PC using the DISOPLAN T
program operating under Windows.
If no Windows PC is available, DISOMAT
T can also be configured using the built-in
Command-Line-Interpreter (TCLI) on a
VT Terminal or PC with VT emulation.
DISOMAT T configuration
102
Housing Dimensions:
19" rack DNG 100
(Fig.1)
Fig.1
Designed for control cubicles accessible 19" rack DNG 100
from the rear or equipped with swivelling
frame. DNG 100 can be equipped with
max. 10 main boards. One slot each is
required for:
- DWT 100
DISOMAT T as printed circuit board
- DXB 100
ex-protective circuitry
- DNT Power supply unit for 115/230 VAC
supply (one-only power supply unit per
rack)
- Blanking panel
Fig.2
Field housing
Front protected to: IP 20 DFG 100
Weight (equipped): 10 kg
Material: Polyester
0
15
Protected to: IP 65
Weight: Approx. 3-4 kg
Fig.4
Expansion boards
- DISONET board DDN V100
- PROFIBUS board DPB V100
One expansion board can be
plugged onto weigh transmitter
Fig.3
board DWT 100.
Weigh transmitter DWT 100
- Ex-protective circuitry DXB 100
- Power supply DNT 300 and DNT 310
are of the same size.
103
Technical Data
104
Technical Data DISOMAT T - Designed for expansion
Primary and secondary side
galvanically isolated to VDE 0160.
Ex-protective circuitry Ex-protective circuitry DXB 100; Weigh Transmitter
board incl. front panel of same size
as main card DWT 100.
Designed „intrinsically safe“ for
- Load cell connection
- Serial interface for secondary
displays
- Analog output for secondary
displays
- Binary input for two contacts (e.g.
initiators)
PTB No. Ex-95. C. 4005 X
Ex-load cells 1 - 8 SCHENCK RT load cells EEx ib
llC T6, PTB No. Ex 82/2135,
supply voltage for RT load cells:
16.8 V with one load cell
15.4 V with two load cells
14.8 V with three load cells
13.1 V with four load cells
11.5 V with six load cells
10.2 V with eight load cells
1 HBM load cell 350 Ù, Z6H,
Z6C, Z6 2, Z6 4, EEx ibllC T4,
PTB No. Ex 90.C.2094,
supply voltage 9.2 V
Options Displays for analog output and for
serial interface.
105
Variants Order No. DFG 102E D 707046.02
DWT 100 D 707039.01 DISOMAT T in DFG field housing,
DISOMAT T weigh transmitter, for 24VDC infeed, with mounted Profibus
PC board including front panel expansion card, DPB-info project
proposal disk, special Siemens connection
DWT 101 D 707039.02 solution for Profibus networks in Simatic
DISOMAT T weigh transmitter, controls, Ex protective circuitry
PC board including front panel, with
mounted Profibus expansion card and DFG 103E D 707043.06
DPB-info project proposal disk DISOMAT T in DFG field housing,
for 24VDC infeed, with mounted
DWT 103 D 707039.03
DISONET expansion card and
DISOMAT T weigh transmitter,
Ex protective circuitry
PC board including front panel,
with mounted DISONET expansion card DFG 110E D 707044.04
DFG 100 D 707043.01 DISOMAT T in DFG field housing,
DISOMAT T in DFG field housing, with transformer for 115/230VAC
for 24VDC infeed infeed and Ex protective circuitry
106
DISOMAT C Weighing Controller
Application Equipment
Designed for weight value monitoring The reliable separation of input and DISOMAT C is a complete evaluation
and simple control tasks, the output prevents possible interfering system for scales mounted on strain
DISOMAT C weighing controller is noise from connected devices. gauge load cells. The basic unit
suitable for hopper level monitoring, DISOMAT C is prepared to communi- already comprises load cell supply,
single-ingredient fill and discharge cate with its environment through amplifier, A/D converter, digital
feed operations, tolerance and limit analog output, serial interfaces, two display, logical function block system,
value monitoring as well as for scales contact and four relay outputs. input/output contacts, analog output,
with data coupling to host systems. serial interfaces, safety isolation,
DISOMAT C is particularly well connection for 24 V DC power supply.
suitable for weighing tasks which are This basic unit is the DWC 300
likely to be altered at a later stage: cassette. It can be supplied loosely or
The combination of built-in logical installed in the housing of your choice.
function blocks can be changed via All types of housing are designed to
serial communication interface or accommodate a DNT power supply
directly via the DISOMAT C keypad. unit. Interactive dialogs for operation,
setting and calibration are in German
or English, selectable using the
keypad.
107
Functions
DISOMAT C-B version
DISOMAT C-B comes with three standard
function block configurations:
– Limit value monitoring
– Discharge feed
– Fill feed
The user can select the desired confi-
guration by menu.
Housing variants
For panel mounting:
Panel mounting housing DEG 300 (Fig. 1)
Front protected to: IP 54
Weight (equipped): 4.6 kg
Designed to accommodate one DMC 300
cassette and one DNT power supply or
for one DWC 300 for use in hazardous
areas (without DNT). Fig. 2 Wall mounting housing DWG 300
108
Technical Data Technical Data
Display: Backlit LCD, two lines, 16 digits, 5 mm Max. switch-on peak: 10 A
character height, 5-digit weight display Binary input/output functions
Load cells: Max. 12 RT load cells determined through logical function
Max. four 350 q load cells blocks; galvanically isolated (to
VDE 0160).
Load cell supply: 20 V and 10 V
3 Serial interfaces: SS1: RS 485/RS 422 for EDP or
Load cell cable: Max. 1000 m secondary display, max. 9600 Baud
Measuring input SS2: RS 232 on 20mA current loop,
overload protection: + 30 V for EDP, PLC, or PC, max. 9600 Baud
DISONET: RS 485 for DISONET
Accuracy: Linearity: < 0.01 % Master option card
Range stability: EDP interface installed on SS1
< 6 ppm/K legal-for-trade version or SS2
< 20 ppm/K basic version Protocol 3964 R for PC and
Zero point stability: SIMATIC S5 mode. More than
0.2 µV/K legal-for-trade version 40 EDP commands, up to 9600 baud.
1.0 µV/K basic version Serial interfaces SS2 and DISONET
Number of increments: 100 to 50 000 d galvanically isolated.
100 to 3 000 d Analog output: 0 to 20 mA, or 4 to 20 mA
(with legal-for-trade applications) Load: max 500 q
Measuring rate: 100 measured values/second Linearity: 0.05 %
Range stability: < 0.05 % / 10 K
Temperature range: -10° to +50°C Zero point stability: < 0.1 % / 10 K
-10° to +40°C (with legal-for-trade Analog outputs assigned to Gross,
applications) Net, residual value, dW/dt or total
Sensitivity: 1 µV/d; legal-for-trade: 2 µV/d through logical function blocks;
galvanically isolated.
Input signal: 0.1 to 57 mV
0.2 to 57 mV (with legal-for-trade Interface expansion - MODBUS (SS1 or SS2)
applications) option: - Teleperm M (SS1 or SS2)
- DISONET Master connection
Dead load signal: 0 to 57 mV (DISONET)
Power supply: 24 V DC, 10 W, 17 to 36V tolerance, Ex protective circuitry Ex protective circuitry DXB 300; card
incl. residual ripple (option): incl. front plate and blind plate which
Data backup: Maintenance free, no battery. All adapts the width to DWC 300. The
setting data stored voltage fail-safe in DXB 300 can be combined with all
EEPROM. All process data (e.g. DISOMAT C housings.
accumulated or tare values) protected Hazardous area equipment
from power failure by 30-minute short („intrinsically safe“):
time buffer. - Connection to load cells
Zero setting function: Max. 20% - 8 x 4000 q load cells
Max. 4% (-1% to +3%) (legal-for supply voltage:
trade version) 17.8 V for one load cell
Automatic zero tracking 0.5 d/s; 16.3 V for two load cells
deselectable 14.4 V for three load cells
13.3 V for four load cells
Filter: Low-pass and software filter
11.1 V for six load cells
1 to 10 sec.
10.2 V for eight load cells
Line interference suppression:
- 4 x 1000 q load cells
100 dB, 48 to 62 Hz
Supply voltage 7.8 V
Mains synchronous interference
- 1 x 350 q load cells
suppression: > 110 dB
Supply voltage 7.8 V
EMC interference - serial interface for secondary display
immunity: To DIN IEC 770, IEC 801, and others - analog output for secondary display,
EMC radio interference To DIN VDE 0871 Class B, BMP Reg. max. 200 q
suppression: 243/1991 - 2 binary inputs
Ex secondary displays see
Electrical safety: To IEC 348, DIN VDE 0411, Part 1 accessories
Binary inputs/outputs 2 inputs, optocouplers, 12 to 35V, Suitability for trade use Approved as legal-for-trade scale
5 to 17 mA (option): up to 3 000 d
4 relay outputs, 220 V AC/0.2 A, Type code „e“
or 24 V DC/0.5 A, Legal-for-trade cassettes DWC 310
109
Variants Order No. Variants Order No.
with 24VDC power supply D 721050.01 with 24VDC power supply D 721050.05
with DNT 300 power supply with DNT 300 power supply
for 230VAC D 721050.02 for 230VAC D 721050.06
with DNT 310 power supply with DNT 310 power supply
for 115VAC D 721050.09 for 115VAC D 721050.17
with DNT 310 power supply with DNT 300 power supply
for 115VAC D 721050.14 for 230VAC D 721050.22
with DNT 310 power supply with 24VDC power supply D 708519.05
for 115VAC D 721050.16
with DNT 300 power supply
DISOMAT C-B weighing controller for 230VAC D 708519.06
with Ex protective circuitry DXB 300
as circuit board incl. front plate with DNT 310 power supply
in wall mounting housing DWG 300 for 115VAC D 708519.07
with DNT 310 power supply with 24VDC power supply D 708519.08
for 115VAC D 708519.04
with DNT 300 power supply
for 230VAC D 708519.09
DISOMAT C-B weighing controller
in 19" rack DNG 300 with DNT 310 power supply
for 115VAC D 708519.10
with 24VDC power supply D 721050.11
with DNT 300 power supply All housing types are provided with blind front plates in the
for 230VAC D 721050.12 empty rack spaces.
110
The following products and services may be combined with the
above variants:
111
Notes:
112
DISOMAT C - Limit Value Monitoring
113
Four limit value stages Acquire/clear tare Analog output
Every limit value stage consists of a "Aquire tare" function stores current Output of NET weight as analog value 4
comparator used to compare the entered GROSS weight of load on scale as TARE to 20 mA.
limit value with the weight of load on and switches display over to NET weight.
scale, and a relay serving for the output NET weight means the difference
EDP interface
of comparative result. between actual GROSS weight and
stored TARE weight. DISOMAT C comes with serial interfaces
Relay contacts switching value (opening
for connection of DISOMAT C to EDP,
or closing when exceeding limit value) "Clear tare" function resets tare memory
PLC or secondary display.
and hysteresis behaviour of each limit to zero, with display returning to GROSS
value stage are determined by preset value.
start/stop values of the comparators. "Acquire/clear tare" functions can be Flexibility
Two of the four limit value stages started either via Even though Limit Value Monitoring
compare the entered limit value with the 1. Potential-free external contacts configuration is supplied ready set up, the
GROSS weight of load on scale, no controlling the two DISOMAT C binary logical function block concept allows the
matter wheter scale displays GROSS or inputs preconfigured weighing sequence to be
NET. Comparison takes place every adapted to match your individual needs:
2. Two pushbuttons on DISOMAT C
10 ms. modifications or new weighing sequences
3. Serial interface. can be enabled by new combinations of
The other two limit value stages compare
the net value. This comparison takes stored function blocks. Changing is done
place every 100 ms. via DISOMAT C keypad or, even more
conveniently, on your PC using the
DISOPLAN C software tool.
114
DISOMAT C Discharge Scale
115
Weighing sequences Typical EDP commands Messages initiated by DISOMAT C
– Discharge feed – Tare – Feeding complete
– Discharge feed with refilling – Clear tare – Feeding stopped
– Multiple discharge feeds with refilling – Preset tare value – Weight at standstill
– Set to zero – Cyclic weight
Function keys
– Preset setpoint – Taring complete
– Acquire tare
– Clear tare – Request setpoint – Zeroing complete
– Display tare – Start feeding
– Start – Stop feeding Flexibility
– Stop – Abort feeding Even though discharge scale configuration
– Request feed status is supplied ready set up, the logical
Other menu tree functions function block concept allows the
– Request single weight preconfigured weighing sequence to be
– Set to zero
– Request weight at standstill adapted to match your individual needs.
– Enter setpoint
– Request weight in cycles Modifications or new weighing sequences
– Key-in tare are made possible by new combinations of
– Display gross – Request cumulative total
stored function blocks. Changing is done
– Display cumulative total – Clear cumulative total via DISOMAT C keypad or, even more
– Settings conveniently, on PC using the DISOPLAN
– Test functions Response messages by DISOMAT C C software tool.
– Service functions for parametrization – Message is processed
and calibration
– Command executed
– Command executed, send data to EDP
Input contact assignment
1: Start
2: Stop
Analog output
Output of residual amount related to full
scale value (0/4-20mA)
EDP communication
For DISOMAT C, two EDP transmission
protocols are available:
– SIEMENS 3964 R
– SIEMENS 3964 R for SIMATIC S5
DISOMAT C has a fixed set of commands
that can be addressed by the EDP
programmer, if required. Eligible
commands, messages and protocols are
detailed in the data communication
manual. The EDP commands most
frequently used are listed below:
116
DISOMAT C Filling Scale
117
Weighing sequences Typical EDP commands Messages initiated by DISOMAT C
– Fill feed – Tare – Feeding complete
– Fill feed with discharge – Clear tare – Feeding stopped
– Multiple fill feeds with discharge – Preset tare value – Weight at standstill
– Set to zero – Cyclic weight
Function keys – Preset setpoint – Taring complete
– Acquire tare – Request setpoint
– Zeroing complete
– Clear tare – Start feeding
– Display tare – Stop feeding
Flexibility
– Start – Abort feeding
Even though filling scale configuration is
– Stop – Request feed status
supplied ready set up, the logical function
– Request single weight block concept allows the preconfigured
Other menu tree functions – Request weight at standstill weighing sequence to be adapted to
– Set to zero – Request weight in cycles match your individual needs: modifications
– Enter setpoint – Request cumulative total or new weighing sequences are made
– Key-in tare – Clear cumulative total possible by new combinations of stored
function blocks. Changing is done via
– Display gross DISOMAT C keypad or, even more
– Display cumulative total Response messages by DISOMAT C conveniently, on PC using the DISOPLAN
– Settings – Message is processed C software tool.
– Test functions – Command executed
– Service functions for parametrization – Command executed, send data to EDP
and calibration
Analog output
Output of residual amount related to full
scale value (0/4-20mA)
EDP communication
For DISOMAT C, two EDP transmission
protocols are available:
-SIEMENS 3964 R
-SIEMENS 3964 R for SIMATIC S5
DISOMAT C has a fixed set of commands
that can be addressed by the EDP
programmer, if required. Eligible
commands, messages and protocols are
detailed in the data communication
manual. The EDP commands most
frequently used are listed below:
118
DISOMAT C Check Scale
DISOMAT C
Secondary display
Binary EDP
inputs/outputs
119
Input contacts
Variant Order No.
– Weight of load on scale
(start of weight check cycle) Weighing controller DISOMAT C see DISOMAT C
– Clear total/reset counter Activating „Check scale“
function block linkage D 991 002.04
Output contacts
– Correct weight
– Underweight
– Overweight
– READY message
Flexibility
Even though the check scale configu-
ration is supplied ready set up, the logical
function block concept allows the
preconfigured weighing sequence to be
adapted to match your individual needs:
modifications or new weighing sequences
are made possible by new combinations
of stored function blocks. Changing is
done via DISOMAT C keypad or, even
more conveniently, on PC using
DISOPLAN C software tool.
Options
– Suitability for trade use
– Intrinsically safe connections, PTB/
CENELEC approved to EEx ib
– Secondary display: see accessories
120
DISOMAT F Weight Indicators
K Legal-for-trade
K PC-, desk- and wall-mounted
versions
K Easy-to-read LC display
K Flexible membrane keypad
K Two-language operator
prompting
K Serial interfaces
K Binary inputs/outputs
Application Equipment
DISOMAT F Weight Indicators are DISOMAT F is available in three system (for instance, in the case of
optimally suitable for applications different types of housing: repair work on PC).
which require weight values to be K PC-mounting unit of standard size Direct printer connection on DISOMAT
acquired legal-for-trade, displayed, (5.25") for installation in a drive or F-P enables system to operate in
printed and, if need be, transferred to CD ROM shaft (DISOMAT F-P) emergency mode whenever complete
a host system for further processing. PC functionality is not available. In this
K Desk-top unit with large backlit
Focus is on platform scales with no display and keypad for input of tare case, operation and display are
need for sophisticated control tasks values (DISOMAT F-D) directly performed on DISOMAT F-P.
and on applications where DISOMAT With legal-for-trade scales, printer is
K Wall-mounting unit for vertical
F is used as weight value transducer directly connected to DISOMAT F-P.
installation (DISOMAT F-W).
for PC based weighing and data DISOMAT F Weight Indicator is
processing systems (e.g. road The DISOPLAN-F configuration
equipped with 16-digit LCD for
weighbridges). software permits convenient system
indication of weight value and status
parametrization and calibration via
All hardware and software items are information. Two LEDs signal that
PC.
designed for smooth interaction with scale is totally relieved, or that weight
PC. Appropriate software protocols ensure value displayed is not legal-for-trade
easy and safe data transfer from a at the time being.
DISOMAT F into PC applications.
For printing of weighing results and
The PC variant is designed such that interfacing with EDP station, two RS
no recalibration is necessary after 232 interfaces are available.
dismounting and reassembly of
121
Connection is made via 9-pole, sub-D variant is available equipped with 3 binary Inputs can be read through EDP
plugs (exception: load cell connection via inputs and 4 binary outputs. Outputs can (e.g.read-in of inductive loops). System
plug-in block terminal). Calibration data be set via EDP command and used, for inputs can be firmly assigned to Acquire
and all settable parameters are stored instance, for signal or gate control in Tare, Clear Tare and Set To Zero
fail-safe in EEPROM. In case of power conjunction with a road weighbridge. functions.
failure, a storage battery stores date and
time (real-time clock) for approx. one week.
Functions
DISOMAT-F functionality comprises: Types of Housing
- Weight value display
- Tare value input PC-Mounting Unit
- Weight value and weigh data printout DISOMAT F-P
- Weight transmission to host EDP (PC).
Operation
DISOMAT-F standard operating language
is English. A second language can be
loaded into the system at all times and
put into non-volatile storage using the
DISOPLAN-F configuration software.
In addition to German and French,
several other languages are available.
Language selection as well as scale
calibration and residual settings are
performed in the dialog mode with multi-
level password protection. Scale control
functions, e.g. Acquire Tare, Clear Tare,
Set To Zero, can be called up by function Desk-Top Unit
key operation. DISOMAT F-D
121
Printing
Variable print pattern formatting gives the
user the freedom to design his own
weighing report. The following data can be
7
25
printed:
- Weight values
177
- Date and time
- Current number
- 3 stored texts of 25 digits each.
Arrangement of print elements is defined
by form formats, with one format put into Wall-Mounting Unit
non-volatile storage. Additional formats DISOMAT F-W
can be loaded into the system via EDP Hole pattern
interface and remain stored until any
recurring power failure. Construction of
data message sent to EDP partner can
be configured via loadable form format.
Options
153.5
166.2
146.6
169.9
122
Sample screens with DISOMAT-F
connected to PC
123
Technical Data
Display LCD, backlit; 16 digits, alphanumeric Serial interfaces SS1: RS 232 for EDP or secondary
Character height: display
PC-mounting unit: 5 mm SS2: RS 232 for printer
Desk-top unit: 14 mm Baud rate ≤ 9600 baud
Keypad EDP Protocols SCHENCK DDP8672,
- PC-mounting unit: 4 flexible membrane keys, 8785, 8861 or Siemens 3964R.
multiply assigned Message sequence for cyclic sending:
- Desk-top unit, 0.5 to 99s
wall-mounting unit: 16 flexible membrane keys
Printers:
Protection class: - Local printer Schenck Process DISOPRINT,
- PC-mounting unit: IP 20 Epson and compatible
- Desk-top unit, - Remote printer Schenck Process DISOPRINT
wall-mounting unit: IP 43
Secondary displays: Schenck Process secondary displays
CPU Siemens 80C166, 32kB RAM, DLZ, VLZ, DLS, DLK
8kB EEPROM, 128kB Flash EPROM
CE conformity In accordance with EU directives:
Power supply 9 - 26 VDC, approx. 10 VA 89/336 EC
PC-mounting unit supplied by PC 73/23 EC
power unit 90/384 EC
Temperature range Service temperature: +5 to +35°C
Input signal 0.2 to 68 mV
Sensitivity >1 µV/d standard
>2 µV/d in legal-for-trade use
Measuring rate 77 measurements/second
Unit g, kg, t, lb
Number of increments
- in legal-for-trade use: 100 to 3 000 increments
- in other applications: 100 to 50 000 increments
Taring 0 ... 100% of weighing range
Zero setting function Max. 20% settable,
with legal-for-trade applications:
0 ... +4%, automatic zero
tracking 0.5 d/s, de-selectable
Filter Fixed low-pass for 50Hz suppression;
Suppression of mains-synchronous
interference signals ≥ 100 dB in 47
to 63 Hz range;
Common mode suppression ≥ 110 dB;
Software filter with 0 ...10s filter time
set in the dialog mode
System accuracy Linearity error: ≤ 0.01 %
Zero point stability: ≤ 0.2 uV/K
Range stability: ≤ 6 ppm/K
Clock Date: dd.mm.yy
Time: hh:mm:ss
Back-up time: min. 1 week
Load cells 12 x RT load cells (4000 ohms)
6 x 350-ohm load cells
6 x 1000-ohm load cells
Load cell supply 12 V
Binary inputs/outputs Update in system cycle: every 100 ms
(option) 3 inputs, galvanically isolated
(optocouplers), 10-14VDC, > 10 mA
4 outputs, galvanically isolated
(optocouplers), passive, 5-30VDC,
loadable with 50 mA
124
PC-Mounting Unit Order Number Wall-Mounting Variants Order Number
DISOMAT F-P, PC-mounting unit, D 707 264.01 DISOMAT F-W wall-mounting unit
including WINDOWS 3.x, 95 program for designed for vertical mounting on wall
scale control via PC, driver for DISOMAT or standby column,
control via application packages, complete with printed manual in
DISOPLAN-F configuration software, - German D 707 228.01
documentation on disk, - English D 707 228.02
serial PC connecting cable - French D 707 228.03
DISOMAT F-P, PC-mounting unit extended D 707 218.01 DISOMAT F-W wall-mounting unit
by I/O contacts, including WINDOWS 3.x, designed for vertical mounting on wall or
95 program for scale control via PC, standby column, extended by I/O contacts,
driver for DISOMAT control via application complete with printed manual in
packages, DISOPLAN-F configuration - German D 707 190.01
software, documentation on disk, serial - English D 707 190.02
PC connecting cable - French D 707 190.03
DISOMAT F-P connecting cable module D 707 265.01 DISOMAT F-W PC connecting set D 707 268.01
designed to lead connections for printer including 1.5 m serial PC connecting cable,
(9-pole sub-D connector) and optional WINDOWS 3.x, 95 program for scale
I/O contacts (9-pole sub-D socket) to slot control via PC, driver for DISOMAT
plate mounted on PC rear wall control via application packages,
Manual in DISOPLAN-F configuration software,
German D 707 273.01 documentation on disk
English D 707 273.02 Power supply 230 VAC, VNT 20000 D 707 269.01
French D 707 273.03 Power supply 115 VAC, VNT 20001 D 707 271.01
Power supply 230 VAC, VNT 20000 for D 707 269.01 Power supply 24 VDC, VNT 20002 D 707 272.01
supply of PC unit after dismounting
(Emergency Mode)
Power supply 115 VAC, VNT 20001 for D 707 271.01
supply of PC unit after dismounting
(Emergency Mode)
125
Notes:
126
DISOMAT B Weighing Terminal
Application Equipment
Designed as basic weighing controller, remote display as well as data In all types of housing, DISOMAT B is
the compact DISOMAT B is used for communication with an EDP or PLC fully equipped with 2 serial interfaces,
weighing, controlling, and data pro- system. 4 binary inputs and 4 outputs in an
cessing including printer control. For control tasks four inputs and industrial-type design, DISONET
The large, backlit LCD ensures easy outputs are available which can network interface, and real time clock.
reading of weight values and para- directly control scale functions. All connections are designed as plug-
meters which can be typed in using The DISONET network interface for in terminals.
the 21 membrane keys. Variable print multi-scale systems enables Calibration data and all adjustable
pattern formatting and alphanumeric DISOMAT B to be cross-linked with parameters are stored voltage fail safe
text input is possible.The standard DISOMAT T, DISOMAT C, and in the EEPROM. Date, time, and
function block configurations permit DISOMAT S. process data are stored for at least 10
the DISOMAT B to be used with 6 days.
different types of scales with no need
For special requirements, an interface
for additional software.
expansion card is available.
The user retains flexibility: the logical
function block configuration can be
changed at any time.
The range of standard housings offers
the right type for every environment.
Two serial interfaces permit the
connection of peripherals, printer and
127
Functions Housings
DISOMAT B functionality, the assignment
Desk-top housing DTG 400 DTG 400 with wall support
of keys and control contacts are
Protection: IP 54, plastic DWH 400
established by function block linkage. This
6 cable inlets incl. power cable and Console ergonomically styled by means
concept ensures easy adaptation to very
load cell cable of a rotated front
specific operating requirements.
Weight: 5 kg Protection: IP 54, plastic
The configurations most frequently used
Weight: 5 kg
are stored in the EPROM so that
DISOMAT B is ready to operate as:
- Cargo scale (e.g. platform scale, roller
train scale, or road weighbridge)
- Crane scale
- Check scale
- Filling scale
- Discharge scale
- Receiving scale
Operation
The interactive dialog is in German,
English, French, Italian or Spanish, as
desired. Language combination German,
English, French, Polish and Czech is
available as an option. Language
selection, scale calibration and all other
settings are in the dialog mode, with
multi-level password protection. The scale
control functions are called by key
operation.
Panel cut-out to
DIN 43700
128
Technical Data
Display: Backlit LCD, 16 digits, alphanumeric,
Stainless steel housing DKG 400
character height 14 mm
Protection: IP 65, designed for desk-
top or wall mounting Keyboard: Membrane keyboard with 21 multi-
Weight: 5 kg function keys, 4 keys reserved for
individual assignment
129
Supply for Ex(i) option: 21 V for 1 RT load cell
19.5 V for 2 RT load cells
18 V for 3 RT load cells
17 V for 4 RT load cells
12.7 V for 6 RT load cells
12 V for 350 q load cells
Binary input/outputs: Update cycle: every 100 ms
Quick-acting contacts: every 10 ms
4 inputs, galvanically isolated, safely
separated (optocouplers),
18 to 36V DC, 90 to 250V AC
(47 to 63Hz), > 10 mA
4 outputs, galvanically isolated,
safely separated (relays),
maximum load at 24V AC/DC: 500 mA
maximum load at 90 to 240V AC: 200 mA
Serial interfaces: SS1: RS 232 or RS 485 for EDP,
printer, secondary display or serial
BCD converter.
SS2: RS 232 or 20 mA (TTY) for EDP
or printer.
Baud rate up to 19200 bits/s, EDP
procedure Schenck DDP8 672, or
Siemens 3964R (also S5 operation)
or J-bus.
DISONET network interface for
multi-scale systems
Message cycle: 0.5 to 99s
Options: Communication software ‘DISO 525 B’
for connection to S5
DISOPLAN B: PC program for simple
and comfortable configuration,
parametrization and calibration
Interface expansion card
DSS V400/DSS V401
Analog output:
4(0) to 20 mA, or 4 to 20 mA,
galvanically isolated
Load: < 500 q
Resolution: 10 000 divisions
Update cycle: 10 values/s
Linearity error: < 0.05%
Zero point stability: < 0.10%/10K
Span stability: < 0.05%/10K
Binary outputs:
2 additional outputs (relays)
Serial interface:
RS 232 or TTL for terminal
for connection to Minitel or VT 220
or modem.
EMC interference
immunity: DIN IEC 770, IEC 801, and others
EMC radio interference CISPR 11, DIN VDE 0871, Class B,
suppression: T Fed. Reg. 243/1991
Electrical safety: IEC 348, DIN VDE 0411, Part 1
Climatic test: IEC 68-2-1, IEC 68-2-2, IEC 68-2-14
CE conformity: According to EC directives 89/336,
73/23, 90/384
130
Variants Order No. Variant Order No.
131
Notes:
132
DISOMAT B Cargo Scale
EDP interface
Clear tare
MIN
Output 3
MAX
Printer
Output 4
133
Weighing sequence Print pattern 1: The EDP commands most frequently used
– Gross weighing 1 head line and 1 line for weigh data. A are listed below.
– Gross/Net weighing with automatic string with product data of up to 30
taring digits can be entered for each print. Typical EDP commands:
This string remains stored until being
– Net weighing with manual input of tare – Tare
overwritten. After each print a page
value – Clear tare
feed is effected.
– Net weighing with selection of stored – Preset tare value
tare value
Print pattern 2: – Set to zero
1 line for weigh data. String can be – Request single weight
Function keys
entered and remains stored until being – Request weight at standstill
– Acquire tare overwritten. After each print a line feed – Request cyclic weight
– Clear tare is effected.
– Request cumulative total
– Display tare
– Clear cumulative total
– Manual input of tare Print pattern 3:
– Preset string
– Enter string 1 line for totals print without string.
– Print patterns 1, 2, 3
– Print single weight
– Print with copy to EDP
– Print total and clear cumulative total EDP communication
For DISOMAT B, three EDP transmission
Response messages
Other menu tree functions procedures are available:
– Schenck standard procedure – Message is processed
– Set to zero
– Siemens 3964 R – Command executed
– Select fixed tare
– Siemens 3964 R for SIMATIC S5 – Command executed, send data to EDP
– Display gross DISOMAT B caters for a fixed set of – When receiving command „Print with
– Display cumulative total commands that can be addressed by the copy to EDP“ DISOMAT B after the
– Print sub-total EDP programmer, if required. Eligible successful print sends a response
– Repeat printing commands, messages and procedures message whose data are identical with
are detailed in the commissioning manual. printed variables.
– Settings
– Test functions
134
DISOMAT B Crane Scale
Totals print
Printer
135
Input contact assignment Print pattern
1: Acquire/clear tare
2: Test/zero set/acknowledge error
3: Totals print
Single print:
4: Single print
With cabin controlled cranes, you can enter a product data string for each print.
Function keys String remains stored until being overwritten.
– Acquire tare
– Clear tare
– Display tare Single print with string:
– Manual input of tare
– Set to zero 23.04.93 10:45:00 123 1234567890 <99.5kg>Net
– Enter string 23.04.93 10:47:00 124 1234567890 <100.0kg>Net
.
– Print single weight
23.04.93 11:55:00 150 333-247-A <99.5kg>B
– Print total and clear cumulative total
23.04.93 12:10:00 151 333-247-A <99.0kg>B
23.04.93 12:25:00 152 333-247-A <100.5kg>Net
Other menu tree functions
– Select fixed tare
– Display gross Totals print:
– Display cumulative total
23.04.93 12:30:00 30 3001.5kg SU
– Print sub-total
– Repeat printing
– Settings
– Test functions
Options
Printers and large-size displays see
Variants Order No.
Accessories
DISOMAT B weighing terminal: see DISOMAT B
136
DISOMAT B Check Scale
DISOMAT B
Input contact 1
137
Function keys Print pattern
– Acquire tare
– Clear tare Single print with header (print pattern 1):
– Enter string Date Time Cons. (String) Weight
No.
– Restart
25.10.93 10:45:00 123 1234567890 <123.5kg>B <24.0kg>T <99.5kg>Net
– Print single weight
– Print total, clear cumulative total
Single print (print pattern 2):
– GROSS display . .
– Print repeat
– Settings Totals print (print pattern 3):
– Test functions 25.10.93 11:50:00 30 3001.5kg SU
Printing
Single print is preset with print pattern 2;
totals print, with print pattern 3. The DISOMAT B has a fixed set of – Clear cumulative total
Assignment of print pattern to function can commands that can be addressed by the – Enter string
be changed at will, e.g. single print key EDP programmer, if required. Eligible
– Print print pattern 1, 2, 3
can also be assigned to print pattern 1 commands, messages and protocols are
detailed in the commissioning manual. – Print with copy to EDP
with header.
The variable print pattern formatting gives
the users the possibilty to design their own Typical EDP commands Response messages
weighing reports. – Read function block parameters – Message is processed
(e.g. MIN/MAX limits)
– Command is executed
Input contact assignment – Set function block parameters
– Command executed, send data to EDP
1: Start weighing – Set to zero
– Request single weight – When receiving command „Print with
2: Restart after fault copy to EDP“, DISOMAT B after
– Request weight at standstill successful printout sends a response
3: Stand-by
– Request cyclic weight message whose data are identical with
4: Stand-by
– Request cumulative total printed variables.
EDP communication
For DISOMAT B, three EDP transmission
Variants Order No.
protocols are available:
– Schenck standard protocol DISOMAT B weighing terminal see DISOMAT B
– Siemens 3964 R
Activating „Check scale“ function block configuration D 991 001.03
– Siemens 3964 R (for SIMATIC S5)
138
DISOMAT B Filling Scale
139
Weighing sequences Print pattern 1:
– Fill weighing One head line and one line for weigh data. Typical EDP commands:
– Fill weighing with discharge A string with product data of up to 30 digits – Tare
can be entered for each print. This string
– Multiple fill feeds with discharge – Clear tare
remains stored until being overwritten.
After each print a page feed is effected. – Preset tare value
Function keys – Set to zero
– Acquire tare Print pattern 2: – Preset setpoint
– Clear tare One line for weigh data. String can be – Request setpoint
– Display tare entered and remains stored until being – Start feeding
– Start overwritten. After each print a line feed is – Stop feeding
effected. – Abort feeding
– Stop
– Single print – Request feed status
Print pattern 3: – Request single weight
– Print total and clear cumulative total
One line for totals print without string. – Request weight at standstill
– Request cyclic weight
Other menu tree functions
EDP communication – Request cumulative total
– Set to zero
For DISOMAT B, three EDP transmission – Clear cumulative total
– Enter setpoint
procedures are available: – Preset string
– Enter string – Schenck standard procedure – Print patterns 1, 2, 3
– Manual input of tare – Siemens 3964 R – Print with copy to EDP
– Select fixed tare – Siemens 3964 R for Simatic S5
– Display gross The DISOMAT B has a fixed set of Response messages by DISOMAT B
– Display cumulative total commands that can be addressed by the
– Message is processed
– Print sub-total EDP programmer, if required. Eligible
commands, messages and procedures – Command executed
– Repeat print
are detailed in the commissioning manual.
– Settings The EDP commands most frequently
– Test functions used are listed below.
4: Ready
Single print list (print pattern 2):
Single print is preset with print pattern 2; 25.02.93 10:47:00 124 1234567890 <100.0kg>Net
totals print, with print pattern 3. Assign- . .
ment of print pattern to function key can . .
be changed, e.g. single print key can also
be assigned print pattern 1. . .
The variable print pattern formatting gives 25.02.93 11:45:00 150 1234567890 <99.5kg>Net
the users the possibility to design their 25.02.93 11:47:00 151 1234567890 <99.0kg>Net
own weighing reports. Defaults are as 25.02.93 11:49:00 152 1234567890 <100.5kg>Net
follows:
140
Messages initiated by DISOMAT B
Variants Order No.
– Feeding complete
– Feeding interrupted DISOMAT B weighing terminal see DISOMAT B
– Weight at standstill Activating "Filling scale" function block linkage and setting
– Cyclic weight parameters for print D 991 001.04
– Taring complete
– Zeroing complete
– When receiving command "Print with
copy to EDP" DISOMAT B after
successful print sends a response
message. This message may largely be
configured by the user.
Flexibility
Even though the filling scale configuration
is supplied ready set up, the logical
function block concept allows the
preconceived weighing sequence to be
adapted to match your individual needs:
modifications or new weighing sequences
are made possible by new combinations
of stored function blocks. Changing is
done via DISOMAT C keypad or, even
more conveniently, on PC using the
DISOPLAN C software tool.
142
Notes:
142
DISOMAT B Discharge Scale
Dribble feed
systems or PLC contact
Load
cells
143
Weighing sequences Print pattern 1: commands, messages and procedures
– Discharge weighing One head line and one line for weigh are detailed in the commissioning manual.
data. A string with product data of up to The EDP commands most frequently used
– Discharge weighing with refilling
30 digits can be entered for each print. are listed below.
– Multiple discharge weighings with
This string remains stored until being
refilling
overwritten. After each print a page feed Typical EDP commands
is effected.
– Tare
Function keys
– Clear tare
– Acquire tare Print pattern 2:
– Preset tare value
– Clear tare One line for weigh data. String can be
– Set to zero
– Display tare entered and remains stored until being
overwritten. After each print a line feed is – Preset setpoint
– Start
effected. – Request setpoint
– Stop
– Start feeding
– Single print
Print pattern 3: – Stop feeding
– Print total and clear cumulative totals
One line for totals print without string. – Abort feeding
– Request feed status
Other menu tree functions
EDP communication – Request single weight
– Set to zero
For DISOMAT B, three EDP transmission – Request weight at standstill
– Enter setpoint procedures are available: – Request cyclic weight
– Enter string – Schenck standard procedure
– Request cumulative total
– Manual input of tare – Siemens 3964 R
– Clear cumulative total
– Select fixed tare – Siemens 3964 R for Simatic S5
The DISOMAT B has a fixed set of – Preset string
– Display gross
commands that can be addressed by the – Print patterns 1, 2, 3
– Display cumulative total
EDP programmer, if required. Eligible – Print with copy to EDP
– Print sub-total
– Repeat print
– Settings
– Test functions
144
Response messages by DISOMAT B Flexibility
– Message is processed Even though the discharge scale
– Command executed configuration is supplied ready set up, the
logical function block concept allows the
– Command executed, send data to EDP
preconceived weighing sequence to be
adapted to match your individual needs:
Messages initiated by DISOMAT B modifications or new weighing sequences
– Feeding complete are made possible by new combinations
of stored function blocks. Changing is
– Feeding interrupted
done via DISOMAT C keypad or, even
– Weight at standstill more conveniently, on PC using the
– Cyclic weight DISOPLAN C software tool.
– Taring complete
– Zeroing complete
– When receiving command „Print with
copy to EDP“ DISOMAT B after
successful print sends a response
message. This message may largely be
configured by the user.
145
Notes:
146
DISOMAT B Road Weighbridges ZEUS
K DISOMAT B special
configuration for road DISOMAT B weighing controller
weighbridges
K Excellent price/performance
Printer interface
ratio
K Easy operation
K Operation in German, English, EDP interface
Spanish, Italian, and French
K Legal-for-trade weigh data
transmitter with PC-controlled
scale workplaces
Road weighbridge
147
Single weighing Files
The truck is weighed only once. You can First weighing file
type the known tare weight of truck and contains the data of 40 trucks expected
have the system acquire the net weight. for second weighing
Materials file
File updating functions
contains 25 sorts of materials to be
For clearing/modifying/printing of contents weighed
of
– Materials file
– Vehicle file Truck file
– Fixed file contains number of trucks weighed
Date Time Cons. Mem. Truck No. Mat. Mat. Name Load on Stored Net weight
No. No. No. scale first weight
Weighed by:
Complete package:
DISOMAT B - Road Weighbridge ZEUS in desk-top housing DTG
with user program road weighbridge, printer DISOPRINT 330,
1 package weighing slips ZEUS, operating manual D 721 204.01
DISOMAT B - Road Weighbridge ZEUS in desk-top housing DTG
with user program road weighbridge, power supply unit 230 VAC,
printer cable K 002 028.01
1 package weighing slips (200 slips) 2383.010
Operating manual D 708 455.01
Option: Printer See Accessories
148
DISOMAT B Platform Scale MILAN
K DISOMAT B special
configuration for platform
scales Platform scale Single printout
Input contact 1
K Weighing sequence control via
Acquire tare
keyboard or input contacts Material Input contact 2
K Variable print pattern Pallet Clear tare
formatting with 3 preset print Input contact 3
Ready to operate
Output 2
MIN
Printer interface
Output 3
MAX
Output 4
149
Weighing sequences: Other menu tree functions Printing
– GROSS weighing – Zero set Single print is preset with print pattern 1;
– GROSS/NET weighing with automatic – Select fixed tare totals print with print pattern 3.
taring – GROSS display The variable print pattern formatting gives
– NET weighing with manual input of the user the possibility - within certain limits
– Cumulative totals display
TARE value - to design his own weighing report. The
– Sub-totals print following formats are preset:
– NET weighing with selection of stored
– Print repeat
TARE value
– Settings Print pattern 1:
– Test functions One head line and one line for weigh
Function keys
data. A string with product data of up to
– Acquire tare
Input contact assignment 30 digits can be entered for each
– Clear tare printout. This string remains stored until
1: Single print
– Display tare it is overwritten. After each print a page
2: Acquire tare feed is effected.
– Manual input of tare
3: Clear tare
– Enter string
4: Set to zero Print pattern 2:
– Print single weight
– Print total, clear cumulative total One line for weigh data. String can be
Output contact assignment entered and remains stored until it is
1: Weighing complete overwritten. After each print a line feed
is effected.
2: Ready
3: MIN contact
Print pattern 3:
4: MAX contact
One line for totals print without string.
Print pattern
150
DISOMAT S Weighing and Automation System
Application Equipment
Designed as a high-end compact The DISOMAT S base unit in all K Instrument for copying programs into
system to solve sophisticated static housing variants is equipped with one DISOMAT S.
weighing tasks in conjunction with measuring circuit, two serial interfaces
A specially designed board permits
integral data processing and control and an additional diagnosis interface.
the scale to be used in hazardous
capabilities, the DISOMAT S is Depending on the application, the
areas with no need for external
particularly suitable for applications equipment can be expanded with a
barriers. All connections are designed
where, in addition to high functionality, second measuring circuit for twin-unit
as plug-in block terminals. Calibration
high operating convenience and quick scales and scale groups, colour
data and settable parameters are
and easy service is required. monitor, input/output cards, additional
stored voltage fail safe in EEPROM.
serial interfaces, binary and analog
Date, time and process data are
input/outputs and a host controller
buffered for at least 10 days by a
board (Profibus, Interbus S). I/O
storage battery.
requirements exceeding the interface
board capability are realized with a Options:
CAN bus. The memory card (PCMCIA K Digital displays for reading weight
card) with max. 64 MB storage values from a distance
capacity is used as: K Large PC-compatible keyboards
K Additional high-capacity memory, K Printer for result reporting
e.g. for recipies or as data base and
K Replacement for “alibi” printer. K further operating units
Memory card is designed
legal-for-trade and can be archived. can be connected in addition.
151
Functions Housing
DISOMAT S functionality and the
assignment of function keys and control Desk-top unit DTG Wall mounting unit DWG
contacts are established by software Plastic housing: IP 54 Wall mounting housing with
modules and function block links which 16 cable inlets incl. panel-type control front
ensures flexible adaptation to varying power and load cell cables Plastic housing: IP 54
applications. Weight: 4.5 kg Weight: 4.5 kg
The basic software comprises the
following functions enabling comfortable
operation of platform scales:
Wall holder
K Weighing
K Setting tare
K Clearing tare
K Displaying gross/tare
K Set to zero
K Input of weigh data (40 positions)
K Data recording on printer (option)
K Storing totalized value
K Print-out as intermediate or final total
(option)
K Communication with external operating
units
K Control of remote display
K Preset and definable function keys
K Function test
K Service functions for parametrization
and calibration Front-of-panel mounting unit DEG 19" rack DNG
K Selecting of second scale (Option) Plastic front: IP 54 Plastic front: IP 54
K Selecting coupled scales 1 + 2 (option) Sheet steel housing: IP20 Sheet steel housing: IP20
Weight: 4.5 kg Weight: 5 kg
K Data exchange with on-site EDP as
per protocol of Schenck standard
procedure or SIEMENS protocol
3964 R:
Beginning of weighing per EDP is
possible. The weigh data can also be
transmitted for printing. After the
completion of weighing DISOMAT S
sends a configurable result text to EDP
(e.g.; date, time, current number,
weight, weigh data)
Industrial applications are realized by incl. cable
using application specific software
modules. Customized solutions can be
programmed individually. incl. cable
Panel cut-out to
DIN 43700
Operation
281+0.1 x 135+0.1
Operation and data input is done via a
wash-off flexible membrane keyboard with
tactile feedback enabling alphanumerical
characters to be entered. A PC keyboard The optional colour display offers special
is available as an option. operating convenience. In addition to
The 1/4 VGA light-intense, monochrome improved contrast, safety relevant
LC display with graphics capability is messages and important inpuVoutput
divided into weight display, status display fields, for instance, are highlighted with
and control fields. Control is in the dialog different colours. External control
mode. Context related help text can be terminals and secondary displays can be
added by key operation. connected.
152
Printing Safety concept
Variable print pattern formatting allows Particularly in cases where failure of
Stainless steel unit DKG weigh slips to be designed individually. In weighing electronics may be the cause for
Protection IP 65 addition to weight values, the following high ensuing costs, the new DISOMAT S
Designed for wall mounting data can be printed: safety concept offers to the user
Material: 1.4301 enormous savings in costs and time:
K Date and time
Weight: 13 kg
K Consecutive number K All scale parameters are stored in an
intelligent load cell plug.
K Cumulative total
K Complete application software is
K Number of accumulated weighing
stored in memory card as safety copy.
operations
In case of a fault, the DISOMAT S is
K Weigh data
simply exchanged, the application
K Stored texts software is read in from memory card and
The arrangement of print elements is the scale is again ready to operate.
established by form formats.
Technical Data
Display Monochrome or colour LCD,
backlit, 15 lines of 40 characters
(1/4 VGA), alphanumeric, 3.6 cm
character height, enlargeable to
8 cm. Weight value can also be
represented with 17 mm height.
Keyboard Flexible membrane keyboard with
42 multi-use keys, 10 of which are
for double assignment, partly by
the user himself.
Option: PC key stroke keyboard or
PC flexible membrane keyboard.
CPU Siemens SABC 167, up to 4 MB
RAM or ROM available
Power supply 24V DC, -10%, +15%,
approx. 40VA
Option:
Auxiliary power supply DNT 510 for
115V
Auxiliary power supply DNT 520 for
230V
Temperature range Service temperature: -10°C to
+45°C
Storage temperature: -20°C to
+60°C
Input signal 0.2mV to 68 mV
153
Sensitivity 1µV/d in not-legal-for-trade Climatic test IEC 68-2-1, IEC 68-2-2, IEC 68-2-14
applications, NAMUR DISOMAT S is designed to meet the
2µV/d in legal-for-trade recommendations NAMUR recommendations (NE 21)
applications
Option: CE conformity to EU directives 89/336 EEC
0.5µV/d in not-legal-for-trade 73/23 EEC
applications, 90/394 EEC
1µV/d in legal-for-trade Serial interface S1: DISONET for connection of DT and
applications DTA control and display units and
Measuring rate 75 measurements/second per for interfacing other DISOMAT units
measuring circuit for multi-scale systems
S2: RS 232 for EDP, printer or
Increment value 1; 2; 5; etc. secondary display
Settable from 0.01 to 5 000.00 S3: RS 232 for EDP, printer or
Unit g, kg, t secondary display
No. of increments 4 000 d, legal-for-trade Diagnosis interface:
Option: 6 000 d 9-pole sub D connector for interfacing
Multi-range/multi-divisional scale diagnosis PC, or modem for remote
3 x 3 000 d diagnosis or parametrization
Baud rate up to 19 200 bit/s
Taring 0...100% of full scale EDP protocols Schenck DDP 8 672,
Zero setting function Max. 20% settable; with certified Siemens 3964 R (also S5 mode), via
applications: -1...+3 %; automatic optional input/output card DIO V501 also
zero tracking 0.5 d/s, deselectable J-bus or MODBUS, message rate for
Filter Fixed low-pass for 50 Hz cyclic sending: 0.5...99 s
suppression, suppression of mains Options 8 binary inputs, galvanically- and
synchronous interference signals Input/output card safe-isolated (optocouplers),
≥ 100 dB in the 47 to 63 Hz range, DIO V 500 18 - 36 V DC, 90 - 250 V AC
common mode rejection ≥ 110 dB, (47-63 Hz), > 10 mA
software filter with 0.6 to 10 s filter 8 binary outputs, galvanically- and
time set in dialog safe-isolated (relays), passive, loadable
Accuracy Linearity ≤ 0.01 % at 24 V AC/DC: 500 mA;
Zero point stability ≤ 0.2 µV/K at 90 - 240 V AC: 200 mA
Span stability ≤ 6 ppm/K Input/output card 8 binary inputs, galvanically- and
Data backup Minimum 10 days DIO V 501 safe-isolated (optocouplers),
Load cells 2 measuring circuits, 18 - 36 V DC, 90 - 250 V AC
each 8 x RT load cells (4 000 h), (47 - 63 Hz), > 10 mA
or 4 x 350 h load cells, altogether 2 analog inputs 0(4) - 20 mA,
max. 12 x RT load cells (4000 h) accuracy 0.1 %, can also be used as
or 8 x 350 h load cells counter inputs up to 5 kHz
8 binary outputs, galvanically- and
Load cell supply 24V at 4 000 h safe-isolated (relays), passive, loadable
12V at 350 h at 24 V AC/DC: 500 mA;
Load cells in 1 to 8 Schenck RT load cells at 90 - 240 V AC: 200 mA
hazardous areas EEx ib 11 CT6, PTB No. Ex 82/ 4 transistor outputs for pulse output,
2135, supply voltage for RT load PNP open collector, 24 V, 200 mA,
cells 10-kh pull-down resistor, supplied from
15.3V with one load cell DISOMAT or external source
14.7V with two load cells 2 analog outputs 0(4) - 20 mA
13.7V with three load cells 1 serial interface RS 485
13.1 V with four load cells (4-core) for J bus and MODBUS
11.9V with six load cells 1 serial interface RS 232 or 20 mA-TTY
11.0V with eight load cells or for EDP, printer or secondary displays
1 load cell 350 h, Second measuring 2µV, legal-for-trade DFE 510
Z6H_, Z6C_, Z6-2, Z6-4, circuit 1µV, legal-for-trade DFE 511
EEx ibilC T4, PTB No.
Ex 90.C.2094, supply voltage 9.6V Ex protective circuitry
DXB V 500 for intrinsically safe connection of
EMC interference DIN IEC 770, IEC 801,
immunity and others - 2 scales
- 1 control terminal DT 20 E or DT
EMC radio interference CISPR 11, DIN VDE 0871 30 E or secondary display DTA
suppression Class B. Fed.Reg. 243/1991 10 E, DTA 20 E
Electrical safety IEC 348, DIN VDE 0411, Part 1 - 4 binary inputs
154
Technical Data Options Order No.
DXB V 501 see DXB V500, but without binary Auxiliary power supply 115V/24V DNT 510 3672.054
inputs
Auxiliary power supply 230V/24V DNT 520 3672.053
Fieldbus connection - Profibus interface module
Second measuring circuit 2µV/d,
(10 - 100 msec response time) or
legal-for-trade DFE V510 K 004 078.01
- Interbus S interface
(1 - 20 msec response time) Second measuring circuit 1µV/d,
legal-for-trade DFE V511 D 707 180.01
CAN BUS for extension of binary and serial
peripheral interfaces available in Input/output card DIO V500 K 004 157.03
DISOMAT S Input/output card DIO V501 K 003 967.03
Memory expansion with memory card interface (already (Ex)i protective circuitry DXB V500 K 006 073.01
installed in variants 511, 521, 531) (Ex)i protective circuitry DXB V501 K 006 086.01
Memory expansion up to 4 MB Profibus board DPB V100 D 707 227.01
Slot for memory card (type I or type
11) with up to 64 MB memory Interbus-S board DIB V100 D 707 065.01
capacity for data, recipes or CAN-Bus board DCB 500 K 002 889.01
replacement of “alibi” printer in Alphanumeric PC key-stroke
certified applications. keyboard DTT 510 E 056 925.01
Alphanumeric PC flexible membrane
keyboard DTT 520 E 056 926.01
Housing variant Panel-mounting 19" rack Desk-top unit Wall mounting Stainless steel Plate mounting
unit unit unit unit
Equipment DEG DNG DTG DWG DKG DSG
510 Blind front panel D 707 140.0x D 707 146.0x D 707 152.0x D 707 158.0x - D 707 168.0x
511 Blind front panel with memory D 707 141.0x D 707 147.0x D 707 153.0x D 707 159.0x - D 707 169.0x
expansion and memory card interface
520 Monochrome LC display D 707 142.0x D 707 148.0x D 707 154.0x D 707 160.0x D 707 164.0x -
521 Monochrome LC display with memory D 707 143.0x D 707 149.0x D 707 155.0x D 707 161.0x D 707 165.0x -
expansion and memory card interface
530 Colour LC display D 707 144.0x D 707 150.0x D 707 156.0x D 707.162.0x D 707 166.0x -
531 Colour LC display with memory D 707 145.0x D 707 151.0x D 707 157.0x D 707 163.0x D 707 167.0x -
expansion and memory card interface
To find the order number, please replace the “x” in the above numbers by the code figure for the desired sensitivity:
2 = 2 µV/d in legal-for-trade applications; 1 µV/d in non-legal-for-trade applications
1 = 1 µV/d in legal-for-trade applications; 0.5 µV/d in non-legal-for-trade applications
Example: Desk-top unit with colour monitor, DTG 530, 2 µV/d: Order number D 707 156.02
155
Notes:
156
DISOMAT S Herkules for Rail and Road Weighbridges
157
First weighing: Fixed tare weighing: Customer file
1. Enter 1. Enter Stores 100 customer addresses
- Vehicle number -Vehicle number Structure:
- Customer number -Customer number Customer number 4 characters
- Material number -Material number Name 20 characters
2. Feed weigh slip into printer 2. Feed weigh slip into printer Street 20 characters
3. Perform weighing Place 20 characters
3. Perform weighing
Functions:
4. Print of 4. Print data (see second weighing)
Enter Data
- Customer number Change Data
- Customer address Data bases Print Data
- Date/time Delete Data
Weigh file
- Current number of weighing
- Vehicle number Stores 100 weighing operations/data
- Material number records Vehicle file
- Material name Functions: Stores 100 vehicles/data records
- Weight of load on scale Update Data Structure:
Print Data Vehicle number
Delete Data Weight
Second weighing:
Functions:
1. Enter vehicle number
Materials file Enter Data
2. Enter material number and/or Change Data
customer number if not entered at the Stores 100 material sorts/data records
Print Data
time of first weighing Structure: Delete Data
3. Feed weigh slip into printer Material number 4 characters
Material name 20 characters
4. Perform weighing
Material total
5. Print of Functions:
- Customer number Enter Data
- Customer address Change Data
- Date/Time Print Data
- Current number of weighing Delete Data
- Vehicle number
- Material number
- Material name
- Weight of load on scale
- Stored first weight
- Calculated net weight
Single weighing
1. Enter WEIGH SLIP for Road Weighbridges
- Vehicle number
- Customer number
5822
- Material number
2. Enter tare weight Babcock Materials Handling
3. Feed weigh slip into printer Rose Kiln Lane, Reading
4. Perform weighing Berks RG2 OBY
5. Print of
- Customer number
Date Time Cons Truck Material Material Weight of Load Stored Net
- Customer address No. No. No. Name on Scale 1st Weight Weight
- Date/time
- Current number of weighing
- Vehicle number
06.09.95 13:17 0004 345 XYZ 0001 Coarse Sand <19.78 t>
- Material number
- Material name
06.09.95 13:48 0005 345 XYZ 0001 Coarse Sand <28.18 t> <19.78 t> 08.40tC
- Weight of load on scale
- Entered tare weight
- Calculated net weight
Operator
First weighing, second weighing and
single weighing results are printed on size
A5 weigh slips from left to right, with 1
original and 3 copies:
158
Variant Order No.
DISOMAT S weighing system in D 718 180.01
Materials file on ........ at .....
desk-top housing, with PC keyboard,
0001 Cement 0000007.55t monochrome display, local printer
DISOPRINT 330, 200 weigh slips,
0002 Quartz Sand 0000018.70t
operating manual in English,
0003 Fine Sand 0000014.68t 1 connecting cable, length 5 m.
0004 Coarse Sand 0000021.78t
DISOMAT S weighing system in D 718 180.02
0005 Mortar 0000000.00t desk-top housing, with PC keyboard,
monochrome displayand second
Print on continous paper measuring circuit, local printer
Example: materials print DISOPRINT 330, 200 weigh slips,
operating manual in English and
1 connecting cable, length 5 m.
EDP interface DISOMAT S weighing system in D 718 180.03
RS 423 (or V.10) includes RS 232 desk-top housing, with PC keyboard,
(or V.24/28). Data is transmitted colour display, local printer
automatically after each weighing DISOPRINT 330, 200 weigh slips,
operation. operating manual in English,
Five protocols are available: 1 connecting cable, length 5 m
- SCHENCK standard protocol DISOMAT S weighing system in D 718 180.04
- SIEMENS protocol 3964 R desk-top housing, with PC keyboard,
- SIMATIC S5 colour display and second measuring
- Modbus circuit, local printer DISOPRINT 330,
- SCHENCK poll protocol 200 weigh slips, operating manual
in English and 1 connecting cable,
length 5 m.
Operating manual, German
BVH 2017DE D 708 636.02
Operating manual, English
BVH 2017GB D 708 636.03
Installation/commissioning manual,
English D 991 004.05
Complete signal light and/or gate control upon request
159
Notes:
160
ECOCONT Weighing Electronics
161
Dimensions (mm)
TS 35
133.6
196.5
max
max 200
200 22
51
73.5
170.5
170.5
110
91
260
240
162
ECOCONT in Use
Belt weigher
Impact-
plate
Mass Flow
Solids Flow Meter
Meter
163
ECOCONT, Version FEN 0110 - Technical Data Options
Parametrization Display 7-segment, 4-digit Field housing Housing for ECOCONT accommodation
3 LEDs for ECOCONT (IP 65 / Nema 4)
260 mm x 160 mm x 91 mm
Power supply 24 VDC +30% / –20%
Power consumption 10 W Field housing Housing (IP 65) with 230 V / 24 V
with 230 V power power supply
Ambient Operating temperature supply unit 160 mm x 160 mm x 90 mm
conditions (-25°) 0° - 50°C (115 V upon request)
According to CE regulations
Power supply unit Mounting on TS35 top-hat rail
Protection IP 20 for top-hat rail 115 V and 230 V / 24 V 1.5 A
Inputs Speed input mounting
(NAMUR level 0.04-2500 Hz) Power supply unit 120 V / 24 V, 1 A
Load cell input 120 V (for plug socket)
(Rmin 80 ohms, up to 500 m cable)
Release contact (24V, 5mA) Power supply unit 230 V / 24 V, 1 A
Taring contact (24V, 5mA) 230 V (for plug socket)
Outputs 2 limit values PC connection set 1.5 m cable connection (9-pole) to COM
(230 V, 8 A ohm./1 A induct.) port of PC/Laptop; max. 10 m possible
1 Ready contact Adapter for 25-pole COM port
(230 V, 8 A ohm./1 A induct.) Analog display 0-100%, front-of-panel mounted
Analog output 4-20 mA, 96 mm x 24 mm
(Feed rate/load 0/4 ... 20 mA)
Pulse output Pulse counter, 6-digit, non-resettable
(Totalizing counter 24V/0, 1 A, non-resettable 52 mm x 28 mm
max. 10 Hz) Pulse counter 6-digit, resettable in manual
resettable 52 mm x 28 mm
Serial interface RS 232 for PC configuration
Scale electronics Length to be specified in order
Remote para- PC configuration under Windows 3.x, special cable (when not specified, 20 m are supplied and charged)
metrization display WINDOWS 95 (3.5" disk)
Front panel dimensions 196.5 mm x 133.6 mm
One set of documentation is supplied as standard. Should you FNT 0052 F217982.01
wish additional copies, please order separately. Remember to Field housing with 230V power supply
indicate desired language version. PSLC 242 3669112
Power supply for top-hat rail mounting
115 and 230 V
FNT 0056 3669109
Power supply unit, 120 V (for plug socket)
FNT 0055 3669106
Power supply unit, 230 V (for plug socket)
PC connection set F217479.01
Analog display 3333115
Pulse counter, non-resettable 3380035
Pulse counter, resettable in manual 3380036
Scale electronics special cable 3849059
164
INTECONT PLUS For Measuring Systems
Application Equipment
The INTECONT PLUS Weighing INTECONT PLUS functionality varies K Calibration intervals with signal
Electronics is specially designed for depending on type of scale used. outputs (intervals selectable as
use with continuous weighing However, all variants have the desired)
systems. It is the right solution following common features: K Flow rate pulse (level and pulse
whenever continuous processes K System accuracy better than 0.05% width) settable by parameter
require materials flows to be (DIN 43782), K Status, event, calibration and
measured and acquired with high
K Manual and/or automatic zeroing quantity reports
accuracy with the aid of
K Full feed/dribble feed control for K Simulation mode for testing and
K Belt weighers
accurate batching training.
K Solids flow meters or K High electromagnetic compatibility The system is supplied as front-of-
K Coriolis mass flow meters. K Galvanically isolated outputs panel mounting unit or with wall-
The INTECONT PLUS is primarily K High degree of protection also for mounting housing for local installation.
designed for applications with a need hazardous applications (Ex) Operation is via ergonomically styled
for convenient and elaborate display, keyboard organized by operating and
K Fail-safe data memory (EEPROM) service functions. A luminescent, anti-
control and monitoring functions, in
K Integrated diagnostics and self-test glare two-line clear text display
addition to basic measuring functions.
functions (SPC) ensures good legibility of results.
The weighing electronics ensures
repeatability and transparency of the K Factory presettings for simple and For connection to EDP systems, serial
production process. quick commissioning interfaces (3964(R) or MODBUS) are
K Auto calibration (automatic available. Commercial printers can be
calibrations programs, self-starting connected via RS232 interface.
taring)
165
Functions Dimensions (mm)
Actual flow rate is acquired depending on
INTECONT PLUS For Front-of-Panel Mounting
mechanical system used through
K Belt load and belt speed (belt
weighers)
K Reactive force (solids flow meters)
K Direct mass flow measurement on the Panel Cut-Out
Coriolis principle (mass flow meters).
96
282+0.5 x 88+0.5
In addition to comprehensive basic
equipment, the following scale specific
functions are available:
288
K Belt weighers
- Accurate belt speed measurement
- Belt influence compensation (BIC)
- Belt run monitoring
- Shifting of weighing to point of
discharge
- Legal-for-trade variant
max. 10
(upon request)
K Solids Flow Meters 16
- Adaption to varying measuring 224.5
chute characteristics
K Coriolis Mass Flow Meters
- Accurate speed acquisition
300
242
242
242
330
300
242
330
300
322 322
380 380
410 410
Bottom View
236
236
166
INTECONT PLUS, Basic Variant FIP 400 Options - Technical Data
Technical Data Wall housing for Wall housing protected to
Display Clear text fluorescent display, belt weighers, solids IP 65 (Nema 4) 120 V or
2 lines with 20 digits each, flow meters with 120 V 230 V / 24 V power supply
6 mm character height or 230 V power supply 380 mm x 300 mm x 236 mm
Voltage supply 24 VDC +30% / -25% Wall housing for Coriolis Wall housing protected to
Consumption 20 VA mass flow meters with IP 54 (Nema 4), 120 V or
Ambient conditions Operating temperature -40°C to +45°C control unit and power 230 V / 24 V power supply,
Humidity Class F (DIN 40040) switch, 120V or 230 V control unit and power switch
EMC (OIML, IEC 801, EN 45501) power supply 380 mm x 300 mm x 236 mm
Interference suppression Power supply, 120 V 120 V / 24 V, 1 A (for plug socket)
(EN 55011, VDE 871-B) Power supply, 230 V 230 V / 24 V, 1 A (for plug socket)
according to CE regulations
Analog display 0 - 100%, front-of-panel mounting unit
Protection Front-of-panel mounting housing 4 - 20 mA, 96mm x 24 mm
Front protected to IP 65
Pulse counter, 6-digit, non-resettable
Inputs Speed (RPM) input non-resettable 52 mm x 28 mm
(NAMUR level 0.04 - 2500 Hz)
Load cell input Pulse counter, 6-digit, resettable in manual
(Rmin 80 Ω, up to 500m cable) resettable 52 mm x 28 mm
Release contact (24V, 5mA) Printer 9-dot matrix printer with serial
Outputs 2 limit values interface RS 232 (V 24) and
(230 V 8 A ohm./ 1 A induct.) system cable
Faults S5 interface protocol FSP 0010 program module for
(230 V 8 A ohm./1 A induct.) Siemens S5 (110U / 115U / 135U)
for serial interfacing
Data are made available in a data module.
INTECONT PLUS, Extended Variant FIP 401
User prerequisite: CP524 or equivalent
with 3964(R)- or MODBUS Interface Modules
Additional Functions Technical Data S5 interface protocol FSP 0011 program module for
Inputs Measurement Siemens S5 (115U / 135U)
(Start/Stop 24 V / 5 mA) for serial interfacing
Data are made available in a data module.
Outputs Pulse output (Totalizing counter User prerequisite: CP524 or equivalent
24 V/0,1A, max. 10 Hz)
Analog output (flow rate Weighing electronics Length to be indicated in your order
0/4 ... 20 mA, 500 Ω load) special cable (Without specifications, we supply and charge 20 m)
167
Variants for Belt Weighers Order Number Options Order Number
FIP 400-FBW0200 F217987.01 FNT 0056 3669109
INTECONT PLUS, basic variant 120 V power supply (for plug socket)
FIP 401-FBW0200 F217987.03 FNT 0055 3669106
INTECONT PLUS, extended variant 230 V power supply (for plug socket)
complete with 3964(R) interface module, Analog display 3333115
24 VDC
Pulse counter, non-resettable 3380035
FIP 401-FBW0201 F217988.01
INTECONT PLUS, extended variant Pulse counter, resettable 3380036
complete with MODBUS interface module, Printer F202925.02
24 VDC FSP 0010 F216477.01
S5 interface protocol via 3964(R)
Variants for Solids Flow Meters Order Number
FSP 0011 F216477.02
FIP 401-FDM0200 F217988.04 S5 interface protocol via MODBUS
INTECONT PLUS, extended variant
Weighing electronics special cable 3849059
complete with 3964(R) interface module,
24 VDC
Documentation Order Number
FIP 401-FDM0201 F217988.05
INTECONT PLUS, extended variant INTECONT PLUS Belt Weighers
complete with MODBUS interface module, Operating/Service Manual and
24 VDC Interface Description
Variants for Coriolis Mass Flow Meters Order Number German D707356.01
English D707357.01
FIP 401-FMM0200 F217988.02
French D707358.01
INTECONT PLUS, extended variant
complete with 3964(R) interface module, INTECONT PLUS - Solids Flow Meter
24 VDC Operating/Service Manual and
Interface Description
FIP401-FMM0201 F217988.03
INTECONT PLUS, extended variant
German D707359.01
complete with MODBUS interface module,
English D707360.01
24 VDC
French D707361.01
Wall Housing Options Order Number INTECONT PLUS - Mass Flow Meter
Operating/Service Manual and
FIP 0050 K001381.01 Interface Description
Wall housing for belt weighers,
solids flow meters, 230 V power supply German D707362.01
FIP 0060 K001381.02 English D707363.01
Wall housing for belt weighers, French D707364.01
solids flow meters, 120 V power supply
One set of documentation is supplied as standard. Should you
FIP 0052 F216218.01 wish to receive additional copies, please order separately.
Wall housing for MULTICOR-S40/80 Remember to indicate desired language version.
Coriolis mass flow meter complete with
control unit, power switch and 230 V
power supply unit
FIP 0062 F216218.02
Wall housing for MULTICOR-S40/80
Coriolis mass flow meter complete with
control unit, power switch and 120 V
power supply unit
168
INTECONT PLUS for Feeding Systems
Application Equipment
The INTECONT PLUS Measuring, INTECONT PLUS functionality varies K Feed rate pulse (level & pulse width)
Control and Supervisory System is depending on type of scale used. All settable by parameter
specially designed for use with variants have the following common K Status, event, calibration and
continuous feed systems operating as features: quantity reports
single scales. K System accuracy better than 0.05%
K Simulation mode for testing and
This system is the optimum economic (DIN 43782)
training.
solution for applications which require K Exact speed measurement
material to be fed accurately with no The system is supplied as front-of-
K Optimum control for accurate panel mounting unit or with wall-
need for additional elaborate control of
batching through adaptive control mounting housing for local installation.
the scale environment.
loop Operation is via ergonomically styled
It can be used with
K High electromagnetic compatibility keyboard organized by operating and
K Weighfeeders service functions. A luminescent, anti-
K Galvanically isolated outputs
K Belt weighers, prefeeder controlled glare two-line clear text display
K High degrees of protection
weigh belts ensures good legibility of results.
K Fail-safe data memory (EEPROM),
K Coriolis mass flow meters For connection to EDP systems, serial
K integrated diagnostics and self-test interfaces (3964(R) or MODBUS) are
K Loss-in-weight feeders (discharge
functions (SPC) available. Commercial printers can be
and fill weighings).
K Factory presettings for simple and connected via RS232 interface.
Our catalog offers the INTECONT
quick commissioning
PLUS variant of weighfeeders, DEA
type. Other INTECONT PLUS K Auto calibration (automatic
variants will be quoted upon request. calibration programs), arithmetic
range calibration with no need for
auxiliaries
169
Functions Dimensions (mm)
With weighfeeders, the actual feed rate is
INTECONT PLUS For Front-of-Panel Mounting
acquired purely arithmetically from belt
load and belt speed.
The actual feed rate is compared to
setpoint, with the difference being used
as control signal for speed-controlled belt
drive. Panel Cut-Out
96
282+0.5 x 88+0.5
The control loop ensures that the actual
feed rate is exactly controlled for the
selected setpoint.
In addition to comprehensive basic 288
features, the following functions are
implemented for weigh-feeders:
- Feed control for point of discharge
- Automatic belt run monitoring
- Belt influence compensation
(BIC)
max. 10
16
224.5
630
PG Cable inlet
PG-Kabeleinfhrung
430
430 300
300
500
500
170
IINTECONT PLUS, FIP 403 - Technical Data Power Unit, AC 3-Phase - Technical Data
Display Clear text fluorescent display, Power Unit Power supply for AC 3-phase drive
2 lines with 20 digits each, FAE 5003.01L, 0.75 kW 230V, 50 Hz, IP 20,
6 mm character height including INTECONT PLUS
Power Supply 24 VDC +30% / -25% system cable (1.3 m)
Consumption 20 VA Max. 100 m distance to feeder / other distances upon
request
Ambient temperatures Operating temperature -40° - 45°C
Humidity Class F (DIN 40040)
EMC (OIML, IEC 801, EN 45501)
Interference suppression
(EN 55011, VDE 871-B)
Wall-Mounting Housing - Technical Data
According to CE regulations
Protection Front-of-panel mounting housing, Wall-mounting housing Wall-mounting housing IP 54
front protected to IP 65 with INTECONT PLUS, (Nema 4)
Inputs Speed input 0.75 kW power unit and for power units up to 1.5 kW
(NAMUR level 0.04 - 2500 Hz) 230 V power supply with 230V / 24V power supply,
Load cell input 500 mm x 600 mm x 300 mm
(Rmin 80 q) All parts completely mounted and wired in housing,
circuit diagrams included in documentation
Analog input
(galvanically non-isolated for external
setpoint 0...20mA)
Belt circuit pulse
(NAMUR level)
Options
3 digital inputs
(galvanically free, safety separated; Power supply 120 V 120 V / 24 V, 1 A (for plug socket)
24 V, 5 mA release contact,
taring contact) Power supply 230 V 230 V / 24 V, 1 A (for plug socket)
Outputs Pulse output Local control box with On/Off switch (IP 65) on scale for
(totalizing counter 24V/0,1A, changeover device and support of maintenance work
max. 10Hz) system cable complete with changeover device
2 analog outputs (control circuit) for connection of
(feed rate/load 0/4...20 mA) switch and system cable
8 digital outputs Analog display 0 -100%, front-of-panel mounting unit
(galvanically free, safety separated; 4 - 20 mA, 96 mm x 24 mm
230 V, 8 A ohm./ 1 A induct.; limit Pulse counter, 6-digit, non-resettable
value, ready, prefeeder, drive, non-resettable 52 mm x 28 mm
deviation contacts)
Pulse counter, 6-digit, resettable in manual
Interfaces Printer RS 232 resettable 52 mm x 28 mm
3964(R) interface module (RS422)
MODBUS interface module Printer 9-dot matrix printer with serial
(RS422 or RS485) interface RS 232 (V 24)
and system cable
S5 interface protocol FSP 0010 program module for
via 3964(R) Siemens S5 (110U / 115U / 135U)
used for serial interfacing
Data are made available in a data module.
User prerequisite: CP524 or equivalent
171
Variants for Weighfeeders Order Number Wall-Mounting Housing Option Order Number
FIP403 - FDB0200 F217987.05 FIP 0055
INTECONT PLUS with Wall-mounting housing with 0.75 kW
3964(R) interface module, 24 VDC power unit, 230 V power supply and
FIP403 - FDB0201 F217988.08
INTECONT PLUS, FIP 403 - FDB0200 F215200.11
INTECONT PLUS with
with 3964(R) interface module 24VDC
MODBUS interface module, 24 VDC
INTECONT PLUS, FIP403 - FDB0201 F215200.12
with MODBUS interface module, 24VDC
Housing comes completely mounted and wired.
Power Unit, AC 3-Phase Order Number Other wall-housing variants can be offered upon request.
German D707365.01
English D707366.01
French D707367.01
172
Display and Control Units
K Easily-readable, high-contrast
displays
K Rugged, washable keyboards
K Industrial, versatile program
for a variety of applications
and local conditions
K Legal-for-trade
K Use in explosion hazardous
areas
173
Unit Size
,5
82
72
DLZ 030 E 144
DLZ 030 E
(138)
(138)
134
134
Befestigungsbohrung
Mounting hole
(14)
6
138 65 14
(6) 138
(184)
(65) (134)
DLZ 030 EF
DLZ 030 EF (DLZ 050 EF)
DLZ 050 EF
DTT 11 DTT 11
174
Unit Sizes
DTA 10 / DT 10
DTA 10
DT 10
DTA 20 / DTT 20
DTA 21E
DTA 20 DTT 20
DT 30
DT 30
175
Technical Data
VLZ 20150 VLZ 20250 DLZ 030E / DLZ030EF / DLZ 050EF DLZ 444 DTT 11
Display technique LED, 7-segment LED, 7-segment LCD LCD ---
Display colour Red Red Black Black ---
Unit symbol g / kg / t g / kg/ t Selectable Selectable ---
Display format 6-digit 5-digit 4-digit 3.5-digit ---
Character height 14 mm 25 mm 30 mm/30 mm/50 mm 25 mm ---
Keyboard None None None None Alphanumeric,
flexible membrane keys
Protected to IP40, optionally IP65 Front to IP 65 IP40/IP65/IP65 IP65 IP65
Ambient temperature 0...60°C 0...60°C -10°... 50°C, 65°C / @ T5 -10...50°C -10 ... +50°C
Legal-for-trade No No No No Yes
Ex Protection No No EEx ib IIC T6 EEx ib IIC T6 No
Housing Panel-mounting Panel-mounting Panel-mounting, field, field Wall Desk-top
Data interface RS232; RS422/485 RS232; RS422/485 Analog Analog ---
TTY 20mA TTY20mA 4...20mA 4...20mA
Connection to DISOMAT B, F, S, T B, F, S, T B, F, C, S, T B, F, C, S, T DTA 10, DTA 20
External supply voltage 16-30VDC, 230VAC opt. 16-30VDC, 230VAC opt. --- --- ---
Maximum cable length 100m 100m 750m 1000m 2m
Order number E054592.01/02 (IP65) E054593.01 E909034.01/E909034.02/E909033.01 D415961.01 D706938.01
176
Large Display Units
177
Unit dimensions
All dimensions in mm A B C D E F
DLZ 055 DLZ 055 470 181 109 541 190 135
DLZ 111 945 181 109 1019 190 135
All dimensions in mm G H K L M
DLZ 055 380 70 x 12 480 110
DLZ 111
DLZ 111 855 70 x 12 955 110
–––––––––––––E
b
F
a F–––––E
––––––––––––––––––––––––––––––––––––––––––––––
F E
Seitenansicht
Lateral view
Dimensions in mm
Maße in mm Rear view
Rückansicht
–––––––––––E
b–32
DLK 100-300
F
DLS 160-250
a–32
F ––––––––––––––––––––––––––––––––––––––––––––E
All dimensions in mm a b c
DLK 100 6800 2300 1450
DLS 160 11000 2800 1450
DLK 160 9600 2800 1450
DLS 250 17300 3900 1650
DLK 250 15000 3900 1650
DLK 300 17800 4800 1650
178
Technical Data
DLZ 055 / DLZ 111 DLK 100 / DLK 160 / DLK 250 / DLK 300 DLS 160/ DLS 250
Display type LED Light-reflecting digits LED
Display colour Digits red, matrix yellow Yellow Red
Number of positions 5 5 5
Character height [mm] 55 / 111 100 / 160 / 250 / 300 160 / 250
Units g / kg / t g / kg / t g / kg / t
Status displays Zero/tare/net ----- Zero/tare/net/no-motion
Print active
Reading distance 25 m / 50 m 40 m / 60 m / 100 m / 125 m 60 m / 100 m
Protection type IP 54 IP 54 IP 54
Temperature range -10 ... +50°C 0 ... 60°C 0 ... 60°C
Legal-for-trade Yes No Yes
Place of mounting Floor, wall and Floor, wall and Floor, wall and
ceiling mounting ceiling mounting ceiling mounting
Weight Approx. 7 kg/ Approx. 15 kg/approx. 15 kg/ Approx. 15 kg/
approx. 11 kg approx. 27 kg/approx. 28 kg approx. 26 kg
Swivel-mounted Yes Yes Yes
Data interface RS 423, RS 232 RS 232 RS 232
Connection to DISOMAT DISOMAT B, S, T DISOMAT B, S, T DISOMAT B, S, T
Power supply 100 ... 240 V AC 85 ... 264 V AC 85 ... 264 V AC
(47 ... 63 Hz) (47 ... 63 Hz) (47 ... 63 Hz)
Max. cable length approx. 100 m 100 m 100 m
179
Notes:
180
DISOPRINT VPR 20150 Flat Bed Printer and DISOPRINT 10
DISO
PRIN
T VPR
20150
DISOPR
INT 10
181
Technical Data
DISOPRINT 10 DISOPRINT VPR20150 Printed Area:
Print Speed: 2.6 lines/s 2.1 lines/s DISOPRINT 10 / DISOPRINT VPR 20150
Line spacing: Adjustable Adjustable 109/67
5.2/4
33/26
Number of characters: 54 char/line; normal PICA 35 char/line; normal PICA
65 char/line; compressed 42 char/line; compressed
27 char/line; elongated 27 char/line; elongated
Copies: 1 original, 4 copies, 1 original, 2 copies,
Paper thickness: Paper thickness:
0.05-0.45 mm 0.09-0.35 mm
33/26
Paper Specification:
Form size: Min: h = 80 mm ×w = 70 mm Min: h = 80 mm ×w = 70 mm DISOPRINT 10 / DISOPRINT VPR 20150
Max: Unlimited; print area Max: 182 mm × 257 mm
5.2/4
open to sides and to rear 109/67
33/26
Interfaces: RS 232 C / V24 and Centronics RS 232 C / V24 and Centronics
Option: 20 mA or RS 422
Power supply: 230 VAC ± 10 % - 15 % 24 VDC ± 10 %
50 Hz ± 1 Hz
Option: 24 VDC (9-35 V)
Consumption: 60 VA 15 VA
33/26
Operating temperature: 0°C to +40°C +5°C to +40°C
Storage temperature: -10°C to +50°C -10°C to +50°C Print Pattern:
Dimensions w x h x d: 250 × 160 × 280 mm 180 × 101.5 × 190.5 mm
DISOPRINT 10,
Weight: 6 kg 1.6 kg Sample weighing card for air cargo
Print area: Width:109 mm, length: variable Width: 67 mm, length: variable
DISOPRINT 10 3691.006
Flat bed printer with matrix print head for printing
cut sheets complete with 230 VAC power supply
DISOPRINT 10 E 056 954.01
Flat bed printer with matrix print head for printing
cut sheets complete with 24 VDC power supply
DISOPRINT VPR 20150 D 713 193.01
Flat bed printer with matrix print head for printing
cut sheets complete with 24 VDC power supply
DISOPRINT VPR 20150
Sample Print
Option Order Number 17.06.96 09:08 33
Power supply for DISOPRINT VPR 20150 230 VAC 3691.918
<2252kg> Net
Signature:
182
DISOPRINT 330/431 Printer
183
Technical Data
Variants Order Number
Print speed 225 characters/s DISOPRINT 330 Matrix Printer
(at 10 char/inch) with dot matrix print head D 707 170.03
Line spacing 4.2 mm standard
DISOPRINT 330 F Matrix Printer
Character height 3.1 mm remote printer with dot matrix print head D 707 170.01
Number of characters 80 char/line at 10 char/inch DISOPRINT 330 C Matrix Printer
(normal, PICA) with dot matrix print head and
40 char/line at 5 char/inch Centronics interface D 707 170.02
(elongated)
96 char/line at 12 char/inch (ELITE) DISOPRINT 330 B Matrix Printer
120 char/line at 15 char/inch with dot matrix print head
(compressed) and bar code printing D 707 170.04
136 char/line at 10 char/inch
(normal, PICA; DISOPRINT 431 only)
DISOPRINT 330 Options Order Number
Copies 1 original and 3 copies depending on
paper weight Add-on infeed tractor
Interfaces Centronics or RS 232 C for better form feed E 077 880.02
Power supply 220-240 VAC; 50-60 Hz Cut sheet infeed (50 sheets) E 056 529.01
Consumption Max. 36 W Cut sheet infeed (150 sheets) E 056 529.02
Operating temperature +5°C to +35°C Ribbon cassette E 035 002.07
Storage temperature -30°C to +60°C
Dimensions/weight Without options and connectors Variants Order Number
(w x h x d)
DISOPRINT 431 Matrix Printer
DISOPRINT 330 434 x 160 x 368 mm / 6.7 kg
with dot matrix print head for wider
DISOPRINT 431 639 x 257 x 402 mm / 13 kg
horizontal print area D 713 194.03
Options Add-on infeed tractor
DISOPRINT 431 C Matrix Printer
2 single-bin cut sheet feeders
with dot matrix print head and
(50 or 150 sheets)
CENTRONICS interface, for
With DISOPRINT 431: wider horizontal print area D 713 194.02
Wide horizontal print area (line length) up to 345 mm. DISOPRINT 431 B Matrix Printer
(136 characters at 10 char/") with dot matrix print head
and bar code printing function D 713 194.04
Print Areas
Form set glued at top
DISOPRINT 431 Options Order Number
Add-on infeed tractor
for better form feed E 909 164.05
Min. 70 mm
Max. 364 mm Cut sheet infeed (50 sheets) E 909 164.06
Cut sheet infeed (150 sheets) E 909 164.07
203 mm (80 characters with 10 char/“)
Ribbon cassette E 909 164.04
182-216 mm DISOPRINT 330
182-364 mm DISOPRINT 431
Edge-punched endless paper Manuals Order Number
Manual, German E 909 164.01
Manual, English E 909 164.02
Manual, French E 909 164.03
184
Load Cell Cables, Data Cables, and Control Cables
185
Technical Data
Load cell cable 2 x 4 x 0.5 mm2 Standard load cell cable for inter- 12 25 3849.808
screened connection of load cells and DISOMAT
evaluation and control system
Load cell cable 7 x 0.5 mm2 Load cell cable for cable catenary 11 12.5 3849.701
screened
Load cell cable 8 x 1.5 mm2 Load cell cable for cable catenary H =8 mm 46 E05661301
W=42.2 mm
Load cell cable 7 x 0.5 mm2 Pull-relieved for cable drum 10 20 3849.711
screened
Load cell cable 7 x 0.5 mm2 For permanent installation and 8 11 3813.070
ambient temperatures up to 200°C
Load cell cable 2 x 4 x 0.5 mm2 Light blue, for intrinsically safe 12 25 3849.807
screened connection of (Ex)i load cells used
in hazardous areas
Data cable 4 x 0.14 mm2 Connection of displays, computers, and 6 3.8 3849.420
screened printers to DISOMAT evaluation and
control system
Load cell cable 5 x 2 x 0.56 mm2 Connection of load cell and tachometer 12 19.2 3849.059
screened to DISOMAT E, ECOCONT, and
INTECONT PLUS
Data cable 3 x 2 x 0.23 mm2 Connection of computers and printers 6.8 5.7 3849.306
screened to INTECONT PLUS and ECOCONT
as well as DISOMAT E
(no printer connection)
186
DKK Cable Box
K Easy to install
K Protected to IP 65
K Different variants for extension
or summation of load cell
cables
K Suitable for use in hazardous
areas and extreme environmen-
tal conditions
K Highly resistant against ag-
gressive media
K Extendable for excessive
voltage protection
Application Functions
The cable extension boxes DKK 49 As cable summation box, types DKK For use in the hazardous area, the
and DKK 50, are designed for 5, DKK 69 and DKK 70 are available cable boxes types DKK 49 and DKK
extension of the load cell connecting for 4 load cells, type DKK 68 for 6 69 are available as „EExi“ variants.
cable. load cells. The cable summation boxes The cable boxes types DKK 5,
The cable summation boxes are universally applicable. DKK 50, DKK 68 and DKK 70, if with
DKK 5, DKK 68, DKK 69 and DKK 70, At high temperatures (up to approx. static charge instructions, are likewise
are designed for interconnecting the +150°C), housings are made of suitable for „EExi“ use in hazardous
load cells of a scale. In case of high aluminium, depending on load cell areas.
demands on accuracy, the built-in cable used.
series resistors can be used to If the cable box is exposed to aggres-
perform a corner balance. sive media or mounted in severe
environments, plastic housings are
preferred.
All cable boxes are equipped with
Equipment potential equalization rail for proper
The DKK cable boxes are made of connection of the potential
aluminium die cast or polyester and equalization lines.
sealed between cover and housing.
For easy mounting, all cable
connections are designed as screw-
type terminals.
187
Functions Dimensions
Variants Order No.
Evaluation
unit
DKK 69/DKK 70
Load cell
Options
Variant
a b c d Height ∅ Pro- Weight
mm mm mm mm mm tection kg
DKK 5 260 210 240 110 90 6 2.50
DKK 49 175 80 163 52 57 4.3 0.85
DKK 50 190 75 178 45 55 4.5 IP 65 0.80
DKK 68 260 220 220 192 120 6 3.40
DKK 69 175 80 163 52 57 4.3 0.90
DKK 70 190 75 178 45 55 4.5 0.85
188
Directional Force Exciter DF
189
Dimensions DF DF DF DF DF DF DF DF DF DF DF DF
in mm 100S 200S 300S 401L 400S 401V 5L 5S 501S 501V 601S 601V
A 2x125 1x75 4x120 4x120 4x120 4x120 5x120 5x120 5x120 5x120 4x120 4x120
A1 - 115 - - - - - - - - 150 150
B 380 435 600 600 600 600 730 730 730 730 910 910
C 515 636 690 780 780 780 830 830 830 830 1040 1040
E 434 438 537 568 568 568 568 568 569 569 659 675
F x 31 x 27 x 31 x 25 x 25 x 25 x 31 x 31 x 31 x 31 x 31 x 31
G 18 18 18 34 34 34 23 23 23 23 25 25
H 250 250 310 310 310 310 315 315 315 315 370 370
J 536 646 701 786 786 786 819 819 819 819 1032 1032
K 190 230 250 275 275 275 300 300 300 300 376 376
M 320 320 340 340 340 340 380 380 380 380 470 470
N 240 260 260 260 260 260 300 300 300 300 390 390
O 504 574 600 670 670 794 814 814 918 918 1087 1087
P 434 494 522 580 580 708 712 712 883 883 934 994
R 439 456 543 560 560 560 579 579 579 579 696 696
S 46 44 84 63 63 63 46 46 46 46 16 16
190
Directional force exciter
Exciter Speed Working Moment max. Rated Power of Weight without Unbalances2) Order No.
Type in min-1 in kg cm Exciter Force Drive Motor Protective
min max in kN in kW1) Box in kg
1)
Standard values at operating voltage, the torque in the 0-300 min-1 speed range must be at least double and not more than 2,5 times
the nominal moment.
2)
Including clamping pins, attachments, dipstick, punch; DF 300S and higher with transport restraint.
Delivery period for standard design approx. 2 weeks from clarification of all technical details, subject to being unsold.
DF 100 S 13 X794990.01
DF 200 S 18 S000011.01
DF 300 S 19 X794985.01
DF 401 S/L 29 X794986.01 59 X794987.01
DF 401 V 29 X794996.01 59 X794997.01
DF 5 S/L 34 S006918.01 66 S006918.02
DF 501 S/V 34 S000010.01 66 S000010.02
DF 601 S/V 63 X794751.01 118 X794752.01
191
Universal-joint drive shafts with cardan joint Low-maintenance, attractive price
Universal-joint shafts with rubber joint Maintenance-free, ensure long service life and high reliability
192
Springs for Vibration Machines
193
Da
Da
d
d
L0
L0
194
Application Consulting
195
Static weighing systems Accessories for weighing systems
Road weighbridges
Rail weighbridges Software
Crane scales Application software for weighing electronics and
Platform scales PC systems
Coil scales EDP solutions for solids flow management
Raising platform scales
Ladle turret scales and Tundish scales Vibration systems technology
Roller conveyor scales Vibrating screens
Hopper scales Vibrating conveyors
Solids filling stations Vibrating feeders
Cooling and drying systems
Continous weighing and feeding systems Shakeout systems for castings
Belt weighers Dewatering and washing systems
Weigh feeders
Volumetric feeders Components for vibration technology
Loss-in-weight feeders Directional force exciters
Solids flow meters and feeders Rotary force exiter cells
Mass flow meters and feeders Unbalance motors
Mass flow feeders for pulverized coal Magnetic exiters
Springs for vibration machines
Weighing components Drive shafts
Load cells Control and monitoring electronics for vibration machines
Load cell mounts
Weighbeams Systems
Measuring eyes Automation of bulk solids handling
Special transducers Bulk solids blending and mixture plants
Automation of grinding mills
Weighing electronics for static and continuous Systems for bulk solids classification
weighing systems Burdening systems
Special weighing systems
Wind tunnel scales
Load machines
196
Schenck Process, represented worldwide by its affiliates and
agents, is always close by and available to you. If you are in touch
with us, you are in contact with experts speaking your language
and who grasp your wishes and purposes immediately – optimal
conditions for successful cooperation.
we provide:
· Systems
· Components
· Services