Вы находитесь на странице: 1из 5

Tahoe Design Software’s HYDROFLO 3 (3.0.0.

4) mayo 19, 2019, 11:53 PM


Copyright 2015 (c) All Rights Reserved. www.tahoesoft.com Academic Version

Sistema de hidraulico de bomba - Complete Report


Project file: - Solved

Project Information Open Source/Discharge System


Project: Sistema de hidraulico de bomba Source Elev:
Client: Eduardo Ladino Source Pressure:
Engineer: S.Barbosa-D.Sanchez-J.Caceres-N.Gu Source HGL: 3,00 mtr
Firm: Universidad Autonoma de Colombia Discharge Elev: 18,00 mtr
Address: Calle 12B No. 4-31 Bogota D.C Colombi Discharge Pressure: 0,00 psi
Discharge HGL: 18,00 mtr
Phone: 3219025241 Total Static Head: 15,00 mtr
Fax:
email: joan.barbosa@fuac.edu.co

System Information Liquid Properties


Pipe Head Loss Eq.: Darcy-Weisbach Water,Saturated at 90 deg F
Flow Tolerance: 0,01 USgpm Temperature: 32,20 C
Atmospheric Press: 79,50 psi Specific Gravity: 0,99
Total Elements: 16 (approx) Viscosity: 7,6E-07 ft2/s
Total Branches: 0 (used in solution) Vapor Pressure: 4,00 psi (abs)
Specific Heat: 1,00 Cal/grC

Element Data by type...


Supplys: Pressure Elev Flow HGL
ID Type (psi ) (mtrs) (Ugpm) In/Out (mtrs)
TANQUE 1 reservoir/tank (open) 0,00 3,00 500,00 out 3,00
Inlet/Exit: No pipe inlet/exit losse, Elev=0,00 mtrs
tanque 1
TANQUE 2 reservoir/tank (open) 0,00 18,00 500,00 in 18,00
Inlet/Exit: No pipe inlet/exit losse, Elev=16,50 mtrs
tanque

Pipes: Length Fric Nom D In Dia Flow Direction Vel Head Loss
ID Sched (mtrs) (mm) (inch) (inch) (Ugpm) ->ID (ft/s) (psi )
TUBO1 SP1 5,00 0,002 13 5,016 500,00 ->VALVULA 1 8,12 0,17
succion
TUBO 2 SP1 2,00 0,002 12 3,998 500,00 ->VALVULA 2 12,78 0,21
descarga
TUBO 3 SP1 8,00 0,002 12 3,998 500,00 ->CODO1 12,78 0,83
descarga
TUBO 4 SP1 16,50 0,002 12 3,998 500,00 ->m4 12,78 1,72
descarga
TUBO 5 SP1 4,00 0,002 12 3,998 500,00 ->TANQUE 2 12,78 0,42
descarga
Pipe Schedules...
SP1 = PVC Sched 40

Valves & Fittings: Fric Diameter Flow Direction Head Loss


ID Description K (inch) (Ugpm) ->ID (psi )
VALVULA 1 Globe valve 5,80 5,000 500,00 ->MANOMETRO 1 2,58
VALVULA
VALVULA 2 Gate valve 0,14 4,000 500,00 ->TUBO 3 0,15
VALVULA
CODO1 90 deg bends (r/d= 1) 0,34 4,000 500,00 ->m3 0,37
descarga
CODO 2 90 deg bends (r/d= 1) 0,34 4,000 500,00 ->TUBO 5 0,37
codo

Pumps: Flow inc Shut hd 2nd 3rd 4th Flow Direction Oper Head
ID (Ugpm) (ftlq) (ftlq) (ftlq) (ftlq) (Ugpm) ->ID (ftlq)
BOMBA Undefined pump, design flow = 500,00 Ugpm 500,00 ->MANOMETRO 2 65,13
Elev = 0,00 mtrs
NPSHA = 179,60 ftlq
bomba
Project file: - Solved Page 1
Tahoe Design Software’s HYDROFLO 3 (3.0.0.4) mayo 19, 2019, 11:53 PM
Copyright 2015 (c) All Rights Reserved. www.tahoesoft.com Academic Version

Element Data by type...


Gauges: Elevation Demand Pressure HGL
ID (mtrs) (Ugpm) (psi ) (mtrs)
MANOMETRO 1 0,00 0,00 1,47 1,05
1
MANOMETRO 2 0,00 0,00 29,38 20,90
2
m3 0,00 0,00 27,82 19,78
codo
m4 16,50 0,00 2,90 18,56
codo

Elements in sequence...
Elements in sequence Pressure Elev Head Change HGL
ID Type Desc (ftlq) (mtrs) (ftlq) (ftlq)
Start of Main Line - source side...
TANQUE 1 Supply reservoir/tank (open) 0,00 3,00 9,84
Inlet/Exit: Type=No pipe inlet/exit losses 0,00 9,84
tanque 1
TUBO1 Pipe PVC Sched 40 -0,39 9,45
succion
VALVULA 1 Valve Globe valve -6,02 3,43
VALVULA
MANOMETRO 1 Gauge 1 3,43 0,00 3,43
1
BOMBA Pump bomba 0,00 65,13 68,56
bomba
MANOMETRO 2 Gauge 2 68,56 0,00 68,56
2
TUBO 2 Pipe PVC Sched 40 -0,49 68,07
descarga
VALVULA 2 Valve Gate valve -0,35 67,72
VALVULA
TUBO 3 Pipe PVC Sched 40 -1,95 65,77
descarga
CODO1 Fitt 90 deg bends (r/d= 1) -0,86 64,91
descarga
m3 Gauge codo 64,91 0,00 64,91
codo
TUBO 4 Pipe PVC Sched 40 -4,02 60,89
descarga
m4 Gauge codo 6,76 16,50 60,89
codo
CODO 2 Fitt 90 deg bends (r/d= 1) -0,86 60,03
codo
TUBO 5 Pipe PVC Sched 40 -0,97 59,06
descarga
Inlet/Exit: Type=No pipe inlet/exit losses 0,00 59,06
TANQUE 2 Supply reservoir/tank (open) 0,00 18,00 59,06
tanque
End of Main Line - discharge side...

Elements By ID...
Elements by ID Pressure Elev Head Change HGL
ID Type Desc (ftlq) (mtrs) (ftlq) (ftlq)
BOMBA Pump bomba 0,00 65,13 68,56
bomba
CODO 2 Fitt 90 deg bends (r/d= 1) -0,86 60,03
codo
CODO1 Fitt 90 deg bends (r/d= 1) -0,86 64,91
descarga
m3 Gauge codo 64,91 0,00 64,91
codo
m4 Gauge codo 6,76 16,50 60,89
codo

Project file: - Solved Page 2


Tahoe Design Software’s HYDROFLO 3 (3.0.0.4) mayo 19, 2019, 11:53 PM
Copyright 2015 (c) All Rights Reserved. www.tahoesoft.com Academic Version

Elements by ID...
Elements by ID Pressure Elev Head Change HGL
ID Type Desc (ftlq) (mtrs) (ftlq) (ftlq)
MANOMETRO 1 Gauge 1 3,43 0,00 3,43
1
MANOMETRO 2 Gauge 2 68,56 0,00 68,56
2
TANQUE 1 Supply reservoir/tank (open) 0,00 3,00 9,84
tanque 1
TANQUE 2 Supply reservoir/tank (open) 0,00 18,00 59,06
tanque
TUBO 2 Pipe PVC Sched 40 -0,49 68,07
descarga
TUBO 3 Pipe PVC Sched 40 -1,95 65,77
descarga
TUBO 4 Pipe PVC Sched 40 -4,02 60,89
descarga
TUBO 5 Pipe PVC Sched 40 -0,97 59,06
descarga
TUBO1 Pipe PVC Sched 40 -0,39 9,45
succion
VALVULA 1 Valve Globe valve -6,02 3,43
VALVULA
VALVULA 2 Valve Gate valve -0,35 67,72
VALVULA

Project file: - Solved Page 3


Tahoe Design Software’s HYDROFLO 3 (3.0.0.4) mayo 19, 2019, 11:53 PM
Copyright 2015 (c) All Rights Reserved. www.tahoesoft.com Academic Version

Project: Sistema de hidraulico de bomba Liquid: Water,Saturated at 90 deg F

Main Line (not to scale)

Project file: - Solved Page 4


Tahoe Design Software’s HYDROFLO 3 (3.0.0.4) mayo 19, 2019, 11:53 PM
Copyright 2015 (c) All Rights Reserved. www.tahoesoft.com Academic Version

Sistema de hidraulico de bomba Liquid Properties


Client: Eduardo Ladino Water,Saturated at 90 deg F
Engineer: S.Barbosa-D.Sanchez-J.Caceres-N.Gu Temperature: 32,20 C
Firm: Universidad Autonoma de Colombia Specific Gravity: 0,99
Address: Calle 12B No. 4-31 Bogota D.C Colombi Viscosity: 7,6E-07 ft2/s
Vapor Pressure: 4,00 psi (abs)
Phone: 3219025241 Specific Heat: 1,00 Cal/grC
Notes: joan.barbosa@fuac.edu.co

Operating Results
TDH: 65,13 ft liq
Flow: 500,00 USgpm
NPSHA: 179,60 ft liq
Tot Static Hd: 49,21 ft liq

Pump ID: BOMBA - bomba

Project file: - Solved Page 5