Вы находитесь на странице: 1из 4

1. Which fitting or fitting combination is best used at the base of a soil or waste stack?

A. ¼ bend
B. 2 – 1/8 bend
C. Short sweep, ¼ bend
D. Wye branch and 1/8 bend
2. A change in direction is achieved with the use of which of the following
A. Pipe
B. Fixture
C. Fitting
D. Appurtenance
3. Which of the following testing method is most recommended for sanitary piping system?
A. Hydrostatic test
B. Water pressure test
C. Smoke test
D. Air pressure test
4. One cubic foot is equal to how many cubic inches?
A. 1728 cu in
B. 1500 cu in
C. 1235 cu in
D. 1444 cu in
5. Which of the following is not considered a plumbing fixture?
A. Water meter
B. Urinal
C. Lavatory
D. Water Closet
6. What is the recommended slope percentage of horizontal drainage pipe as provided in the code?
A. 1%
B. 3%
C. 2%
D. 4%
7. An upright wye combination is a kind of ___.
A. Fitting
B. Tool
C. Pipe
D. Fixture
8. Which of the following is considered the most efficient type of venting system.
A. Combination waste and vent
B. Group vent/Circuit Vent/Looped vent
C. Wet vent
D. Individual/Back vent/ Revent
9. Identify what is shown below.

A. Coupling
B. Nipple
C. Union
D. Socket
10. What do you call the portion of the drainage system which cannot drain by gravity into the building
sewer? It requires the use of a sump pump installed in a sump pit where wastewater is collected and
drained into the sewer line using the sump pump.
A. Building sewer
B. Building subdrain
C. Building drain
D. Subsoil drain
11. Which of the following does not directly affect the size of a sanitary drainage pipe?
A. Type and number of fixtures
B. Slope of drain
C. Brand name of piping materials
D. Fixture unit value of fixtures
12. Every exposed trap must ____.
A. Not able to retain large amount of wastewater
B. Not provided with a removable clean-out plug
C. Have inadequate trap seal in order to cause trap seal loss
D. Be self-cleaning
13. Which of the following is not type of copper pipe?
A. Type K
B. Type L
C. Type M
D. Type N
14. Which of the following is an insanitary type of water closet?
A. Hopper type
B. Plunger type
C. Pan Type
D. All of these
15. Plastic pipes are manufactured from ___.
A. Rubber-based plastic
B. Thermoset plastic
C. Thermoplastic plastic
D. None of the above
16. Which is not a sanitary drainage fitting?
A. Wye branch
B. Nipple
C. Tapped Tee
D. Upright Wye
17. The trap sown below is considered objectionable. What is it?
A. Funnel trap
B. Drum trap
C. P-trap
D. Bell trap
18. This refers to the supply pipe between the fixture supply pipe and the water-distributing pipe.
A. Fixture branch
B. Building supply pipe
C. Fixture supply
D. Water service pipe
19. Which of the following is not a type of flushing design action of a water closet?
A. Siphon jet
B. Siphon vortex
C. Wash Down
D. Blow off
20. Identify the type of ventilation system used in the illustration below.

A. Unit vent
B. Individual vent
C. Circuit vent
D. Yoke vent
21. Which of the following materials is not recommended for use in water supply system application?
A. Concrete pipe
B. Plastic pipe
C. Galvanized steel pipe
D. Brass pipe
22. Which of the following affects the flow of water in a pipe?
A. Size of pipe
B. Internal surface condition of pipes
C. Number of turns or changes in direction of pipes
D. All of these
23. One cubit foot of water has a weight equal to
A. 150 lbs
B. 100 lbs
C. 62.4 lbs
D. All of these
24. The tool shown is used to extract pipes. What is it?

A. Monkey wrench
B. Internal wrench
C. Stillson wrench
D. Spud wrench

Вам также может понравиться