Вы находитесь на странице: 1из 7

SLAB DESIGNING (S2)

Ref. Calculations Output

SPECIFICATION

4 3
4500
B

3575

Long span, Ly 4500


Short span, Lx 3575
Ly/Lx 1.258741 < 2

two way slab

Characteristic Actions :
Permanent, Gk (excluding selfweight) 1.5 kN/m²
Permanent, Qk 1 kN/m²
Design Life 50 years
Fire Resistance R60
Exposure Classes XC3
Materials :
Characteristic strength of concrete, fck 30 kN/m²
Characteristic strength of concrete, fyk 500 kN/m²
Unit weight of reinforced concrete 25 kN/m³
Assumed : øbar 12 mm

Slab Thickness

Min. thickness for fire resistance 80 mm


Estimated thickness for deflection control, h Lx/35
102.1429 mm Use, h
150 mm
Ref. Calculations Output

Durability, Fire, and Bound Requirements

Min. concrete cover regard to bond, Cmin,b 12 mm


Min. concrete cover regard to durability, C min,dur 20
Min. required axis distance for R60, a 20 mm

Min. concrete cover regard to fire


Cmin = a - øbar / 2 14 mm

Allowance in design for deviation, Δ Cdev 10 mm

Nominal cover, Cnom = Cmin + Δ Cdev Cnom


30 mm

Loading and Analysis

Slab self-weight 0.15 x 25


3.75 kN/m²
Permanent load (excluding self-weight) 1.5 kN/m²
Characteristic permanent action, Gk 5.25 kN/m²
Characteristic permanent action, Qk 1.5 kN/m²

Design action, nd = 1.35 Gk + 1.5 Qk


9.3375 kN/m

Moment :
Short span, Msx1 = βsx1 n Lx² 4.3613883 kNm/m βsx 0.065
Msx2 = βsx2 n Lx² 3.3549141 kNm/m βsx 0.05

Long span, Msy = βsy n Lx² 2.2813416 kNm/m βsy 0.034


Msy2 = βsy1 n Lx² 3.0194227 kNm/m βsy 0.045

Shear:
Short span, Vsx1 = βvx1 n Lx 4.879875 kNm/m βvx 0.26
Vsx1 = βvx1 n Lx 7.5075 kNm/m βvx 0.4

Long span, Vsy1 = βvy1nLx 7.132125 kNm/m βvy 0.38


10.698188 kNm/m βvy 0.57
Ref. Calculations Output

Main reinforcement

Effective depth :

dx =h - Cnom - 0.5 øbar


150 - 30 - 6
114 mm

dy =h - Cnom - 1.5 øbar


150 - 30 - 18
102 mm

Short span :( midspan)

Msx
K =M / bd²fck
4361388.3 / 1000 12996 30
0.0111865

Kbal = 0.167

0.0111865 < 0.167

Compression reinforcement is not required

z = d[0.5+(0.25-K/1.134)^1/2]
0.7450677 d < 0.95 d Use : 0.74d

As = M/0.87fykz
118.04155 mm²/m Use : H12-300
(377 mm²/m)
Ref. Calculations Output
Short span: (support)
Msx
K =M / bd²fck
3354914 / 1000 12996 30
0.009

K bal = 0.167
0.01 < 0.167

z = d[0.5+(0.25-K/1.134)^1/2]
0.7455908 d < 0.95 d Use : 0.75d

As = M/0.87fykz
90.737484 mm²/m Use : H12-300
(377 mm²/m)

Long span :(midspan)


Msy
K =M / bd²fck
2281341.6 / 1000 10404 30
0.0073092

Kbal = 0.167

0.0073092 < 0.167

Compression reinforcement is not required

z = d[0.5+(0.25-K/1.134)^1/2]
0.7499585 d < 0.95 d

As = M/0.87fykz
54.122429 mm²/m Use : H12-300
377 mm²/m

Min. and max. reinforcement area,


As min = 0.26 (fctm/fyk)bd
137.904 mm²/m

As max = 0.04bh
6000 mm²/m

Ref. Calculations Output

Shear

Max. design shear force, Ved = nLx/2


16.69078 kN

Design shear resistance, k = 1+(200/d)^1/2


1.877193 < 2

ρ¹ = As1/bd =< 0.02


0.0010355

VRd,c = [0.12k(100ρ¹fck)^1/3]bd
28329.973 N = 28.329973 kN

Vmin = [0.35k^3/2.fck^1/2]bd
2394000 N = 2394 kN

VRd,c VEd
28.32997 > 16.69078

Vmin VEd
2394 > 16.69078 OK!

Deflection

Percentage of required tension reinforcement, ρ = As,req/bd


0.001035

Reference reinforcement ratio, ρo = (fck)^1/2 x 10^-3


0.015

Percentage of required compression reinforcement, ρ = As',req/bd


0

Ref. Calculations Output

Factor for structural system,K= 1 use equation 2

l/d = 269.995

Modification factor for span less than 7m 1

Modification factor for steel are provided = As,prov / As,req


0.989362 < 1.5

Therefore allowable span-effective depth ratio = (l/d)allowable


269.995

Actual span-effective = (l/d)actual


39.47368 < 269.995 OK!

Cracking

h = 150 mm < 200mm

Main bar, Smax,slabs = 400 mm

450 > 400


mm mm

Secondary bar, Smax,slabs = 450 mm

525 > 450


mm mm

Detailing 4500

01

02
3575
Reinforcement :
01 01 : H6-300
02
02 : H6-300