CMS Simulator User Guide

www.nojapower.com.au
NOJA-793-00

Revision History

Rev Author Date Comment


OS 3/06/2011 Draft

This document is copyright and is intended for users and distributors of NOJA Power Switchgear product. It
contains information that is the intellectual property of NOJA Power Switchgear and the document, or any
part thereof, should not be copied or reproduced in any form without written permission from NOJA Power
Switchgear.
®
NOJA Power is a trademark of NOJA Power Switchgear and should not be reproduced or used in any
way without written authorisation.

NOJA Power Switchgear applies a policy of ongoing development and reserves the right to change product
without notice. NOJA Power Switchgear does not accept any responsibility for loss or damage incurred as a
result of acting or refraining from action based on information in this Document.

© NOJA Power Switchgear Pty Ltd 2011


www.nojapower.com.au

1 User Guide CMS Simulator


NOJA-788-01

GENERAL INFORMATION.

This procedure provides the instruction for use of CMS built-in simulator of primary voltage and
current.

INTRODUCTION.

CMS software package has an optional module for simulations of voltages and current. Thi module
also allows the operation of the simulated recloser when the tank is not available or RC-10 demo box
is used.

This is licensed module. In order to obtain the licence for this feature, Licence Request must be issued
from CMS (Administration/License details/Request for new licence) or alternatively contact NOJA
Power on sales@nojapower.com.au.

Care should be taken when simulator is used on the equipment installed in service.
Incorrect use of the simulator might result in tripping of the recloser.

APPLICABILITY.

This procedure is applicable for CMS software version 1.0.1238 and above. The person, working with
Simulator, shall have good knowledge of OSM and RC products and be familiar with CMS software
package.

EQUIPMENT AND TOOLS REQUIRED.

 Personal Computer (PC) with CMS software installed and Simulator module licensed
 USB A to USB B cable for connection of the PC to RC-10 cubicle or Demo Box
 RC-10 Control cubicle or Demo Box.

USING OF SIMULATOR

When Simulator module is licensed, the Simulator configuration will be added to the “System -> Libraries” tab:

The icons in “Simulator” tab perform the following functions:

- “Open”: This function provides the list of the files and allows you to open selected file.
- “New”: This function generate the new file template
- “Delete”: This function allows you to delete the selected file
- “Simulation Library” allows to view the database of the files available
- “Import”: This allows you to bring the files from another PC
- “Export”: This allows you to export the file to another PC

CMS Simulator User guide 2


NOJA-788-01

The simulated signals must be configured and saved in the Simulator file first. To create the file,
select “New” from Simulator Libraries option:

- Select “New”. New windows will appear

- Enter required parameters:


o Phase Current and angles between the phases. Please note that the residual current will be
calculated automatically
o Terminal voltages and angles
o Frequency
o End Condition which include
 Open. The simulated signals will remain simulated in the Relay until OSM opens
 Closed. The simulated signals will remain simulated in the Relay until OSM closes
 Timeout (in msec). The simulated signals will remain simulated in the Relay for the
specified duration of time
o “Use OSM Simulator” tick box. This is required to be checked if the CMS working with the RC-10
demo box or RC-10 controller when the recloser is not connected.

The Example of the fully configured sequence is given below:

3 User guide CMS Simulator


NOJA-788-01

In order simulate the primary signals or fault in the relay, CMS should be on-line with the RC-10 controller or
Demo Box. The controller/demo box must be in Local mode to allow the sequence to be simulated.

To inject the sequence in the Relay, go to “System -> Online Operations” and select the desirable file from the
drop down list under “Start Simulator” button:

When Simulation is applied to the relay, the analogue values will be reported on the Panel, CMS and DNP3
protocol. Protection operation of the recloser can be tested – this will require the configuration of the protection
settings. Also the OSM simulator can be operated from Panel, CMS or protocol.

To stop the simulation – please press “Stop Simulation” button or wait till the end of the sequences.

CMS Simulator User guide 4