Вы находитесь на странице: 1из 6

All Metal

Variable Area Flowmeter


for liquids and gases

KDS

OO Measuring range:
0.1 - 1 l/h ... 20 - 200 l/h water
3 - 30 Nl/h ... 600 - 6 000 Nl/h air
OOAccuracy:
±3 % of full scale
OO pmax: 420 bar; tmax: 130 °C
OO Connection:
¼" NPT female thread (option
valve)
OO Material: stainless steel
OO  ontacts, analogue output
C
(optional)

base@basesistemas.com
976 587 019
https://basesistemas.com/kobold-elementos-de-instrumentacion-y-control-industrial/
All Metal Variable Area Flowmeter Model KDS

Function Technical Details


The fluid flows from bottom to top through the meter tube Materials
of the flow meter. The float is lifted until an annular gap Measuring cone,
between the measuring cone and the float is produced which float, armature: stainless steel
corresponds to the flow. The forces acting on the float are in other materials on request
equilibrium.
Sealing: PTFE (special on request)
The height of the float resulting from the flow rate is transmitted
by the permanent magnet in the float through the magnetic Process connection: ¼" NPT (F), adapter for other connec-
tracking system in a rotation to the pointer axis of the analog tions available
indicator unit. special connections on request
The variable-area flowmeter consists of a stainless steel device Nominal pressure: PN 40 (KDS-K, C)
with an integrated conical stainless steel measuringtube and PN 63 (KDS-S)
a vertically movable float. The valve for setting the flow rate is optional up to 420 bar (KDS-S)
built-in (only KDS-K/C).
Accuracy
liquid/gas: ±3 % qG 50 acc. VDE/VDI 3513
Application
The KDS meter is suitable for flow measurement of liquid or Process temperature: -40 °C ... +130 °C
gaseous products in pipes. (without switch/electronic)
limit switch: NJ 1, 5-6, 5N
It shows the current flow rate in volume or mass per unit in
-25 °C ... +100 °C
time.
NJ 2-11 SN -40 ... +100 °C
-40 °C ... +100 °C
Areas of Application (c/w electronic KDS- ... E)
OO Flow measurement of liquids and gases
Ambient temperature: -25 °C ... +70 °C
OO Dosing
Weight: 0.65 kg
OO Can be used in the chemical industry or in medical or
laboratory engineering Protecion: IP 65 (EN60529)
OO Robust mechanical system with a low rate of wear
Certificate and Approval
Explosion protection: BVS 03 ATEX H/B 113
The devices are available with additional electrical equipment
for process monitoring and control. Pressure drop: [H2O/mbar]
OO Design for horizontal and vertical connections available
Measuring range KDS-S... KDS-K/C...
OO A variety of sealing materials
A 6 6
OO Wall mounting possibility (KDS-C)
B 7.5 7
OO Flow Controller (option)
C 7.5 7
OO High pressure application (option)
D 8 10
E 9 12
F 10 17
G 11 25
H 12 45
I 15 95
J 20 -
K 28 -
Reference condition:
according to IEC 770, water at 20 °C
complete opened valve

base@basesistemas.com
976 587 019
https://basesistemas.com/kobold-elementos-de-instrumentacion-y-control-industrial/
All Metal Variable Area Flowmeter Model KDS

Display: %-scale Certification and Approvals


measuring range scale
Explosion protection: NJ1,5-6,5N PTB 00 ATEX 2048 X II
Electrical outputs: 2G Ex ia IIC T6-T4
Limit contacts: 1 up to max. 2 inductive limit NJ 2-11SN PTB 00 ATEX 2049 X II
contacts, NAMUR (Pepperl & Fuchs 2G Ex ia IIC T6-T4
NJ 1.5 ... 6.5 N); 8.2 V (Ri ~1 KΩ)
ZELM 03 ATEX 0128 X II 1D Ex iaD
(NJ 2 ... 11-SN); 5 … 25 VDC (safety
20 T ...°C
wiring)
KDS-(E) II 2G Ex ib IIC T4 Gb, II 2D Ex
Analogue output
ib IIIC T 135°C Db
(KDS-…E): 4 ... 20 mA, 2-wire, passive;
14-30 V; burden max. 500 Ω version CE-Marking: Explosion Protection Directive
Ex (intrinsically safe) electrical 94/9/EC, PED 97/23/EG
connection via M12 plug Electromagnetic
Ambient temperature: -25 °C ... +70 °C compatibility for
add-on electrical
sensors: EMC-Directive 2004/108/EG
EN 61326-1:2006
SIL: SIL conformity acc. IEC-61508-
2:2000 and IEC-61508-2:2010,
declaration of conformity as separate
document available

Connection vertical KDS-S... (Example: KDS-SA P 30 A 00)


Measuring range Order- Material Connection Scale Contacts Special
code option
Water Air
(1000 kg/m 3)
1.013 bar
abs., 20 °C
l/h Nl/h

0,1 - 1,0 3 - 30 KDS-SA...

0,25 - 2,5 5 - 50 KDS-SB...


0 = without
for gases
only
6 - 60 KDS-SL... 1 = 1 x In-
for gases ductive
7 - 70 KDS-SM... A = % scale
only contact
B = standard-
for gases 2 = 2 x In-
only
11 - 110 KDS-SN... scale H2O
ductive
C = standard-
0,6 - 6,0 18 - 180 KDS-SC... contacts
scale air
3 = 1 x In- 0 = without
P = st. steel/ D = % scale
1,0 - 10 30 - 300 KDS-SD... ductive X = special
PTFE 30 = ¼" NPT fluid
contact acc. to
fitting female E = MR-scale
1.6 - 16 48 - 480 KDS-SE... acc. to specifi-
X = special fluid
safety cation
2.5 - 25 75 - 750 KDS-SF... F = double scale
standard
acc. to
E = transmit-
4.0 - 40 120 - 1200 KDS-SG... specification
ter 4-20
X = special
6.0 - 60 180 - 1800 KDS-SH... mA
scale
without
10 - 100 300 - 3000 KDS-SI... HART®,
EEX ib
16 - 160 480 - 4800 KDS-SJ...

20 - 200 600 - 6000 KDS-SK...

base@basesistemas.com
976 587 019
https://basesistemas.com/kobold-elementos-de-instrumentacion-y-control-industrial/
All Metal Variable Area Flowmeter Model KDS

Connection horizontal KDS-K... (Example: KDS-KA P 30 A 0 0)


Measuring range Order- Material Connection Scale Contacts Special
code option
Water Air
(1000 kg/m3) 1.013 bar
abs., 20 °C
l/h Nl/h

0.1 - 1.0 3 - 30 KDS-KA...

0.25 - 2.5 5 - 50 KDS-KB...

for gases
only
6 - 60 KDS-KL... A = % scale 0 = without
B = standard- 1 = 1 x Inductive
for gases
only
7 - 70 KDS-KM... scale H2O contact
30 = ¼" NPT
C = standard- 2 = 2 x Inductive
for gases female
only
11 - 110 KDS-KN... scale air contacts
U0 = ¼ NPT
D = % scale 3 = 1 x Inductive 0 = without
P = st. steel/ female
0.6 - 6.0 18 - 180 KDS-KC... fluid contact X = special
PTFE valve at
E = MR-scale acc. to acc. to
fitting bottom
1.0 - 10 30 - 300 KDS-KD... fluid safety specifi-
X = special O0 = ¼" NPT
F = double standard cation
female
1.6 - 16 48 - 480 KDS-KE... scale acc. E = transmitter
valve at
to specifi- 4-20 mA
top
2.5 - 25 75 - 750 KDS-KF... cation without
X = special HART®,
4,0 - 40 120 - 1200 KDS-KG... scale EEX ib

6.0 - 60 180 - 1800 KDS-KH...

10 - 100 300 - 3000 KDS-KI...

base@basesistemas.com
976 587 019
https://basesistemas.com/kobold-elementos-de-instrumentacion-y-control-industrial/
All Metal Variable Area Flowmeter Model KDS

Connection horizontal for wall mounting KDS-C... (Example: KDS-CA P 30 A 0 0)


Measuring range Order- Material Connection Scale Contacts Special
code option
Water Air
(1000 kg/m3) 1.013 bar
abs., 20 °C
l/h Nl/h

0.1 - 1.0 3 - 30 KDS-CA...

0.25 - 2.5 5 - 50 KDS-CB...

for gases
only
6 - 60 KDS-CL... A = % scale 0 = without
B = standard- 1 = 1 x Inductive
for gases
only
7 - 70 KDS-CM... scale H2O contact
30 = ¼" NPT
C = standard- 2 = 2 x Inductive
for gases female
only
11 - 110 KDS-CN... scale air contacts
U0 = ¼ NPT
D = % scale 3 = 1 x Inductive 0 = without
P = st. steel/ female
0.6 - 6.0 18 - 180 KDS-CC... fluid contact X = special
PTFE valve at
E = MR-Scale acc. to acc. to
fitting bottom
1.0 - 10 30 - 300 KDS-CD... fluid safety specifi-
X = special O0 = ¼" NPT
F = double standard cation
female
1.6 - 16 48 - 480 KDS-CE... scale acc. E = transmitter
valve at
to specifi- 4-20 mA
top
2.5 - 25 75 - 750 KDS-CF... cation without
X = special HART®,
4.0 - 40 120 - 1200 KDS-CG... scale EEX ib

6.0 - 60 180 - 1800 KDS-CH...

10 - 100 300 - 3000 KDS-CI...

base@basesistemas.com
976 587 019
https://basesistemas.com/kobold-elementos-de-instrumentacion-y-control-industrial/
All Metal Variable Area Flowmeter Model KDS

Dimensions (mm)

KDS-K, C
min. 92
max. 102

¼" NPT
D - D (1 :
¼"NPT

100
90
80
D
70 D: 1000 kg/m³
T: 20 °C
V: 1m/Pas
60 P: 40 bar über
122

50
90

KDS
50
93

40

30

20
10
0

¼" NPT 100


90
80

70 D: 1000kg/m³
77
180

T: 20 °C
V: 1 m/Pas
63 60 P: 40 bar über

115
KDS
50
D - D (1 : 1)
92,5

40

KDS-S ¼"NPT 30

20

D 10
0
22,5

100
90
2 4
80 SW
70 D: 1000kg/m³
180

T: 20 °C
V: 1 m/Pas
60 P: 40 bar über
115

KDS
50
93

40

30

20
10
0
23

base@basesistemas.com
976 587 019
https://basesistemas.com/kobold-elementos-de-instrumentacion-y-control-industrial/

Вам также может понравиться