Академический Документы
Профессиональный Документы
Культура Документы
KDS
OO Measuring range:
0.1 - 1 l/h ... 20 - 200 l/h water
3 - 30 Nl/h ... 600 - 6 000 Nl/h air
OOAccuracy:
±3 % of full scale
OO pmax: 420 bar; tmax: 130 °C
OO Connection:
¼" NPT female thread (option
valve)
OO Material: stainless steel
OO ontacts, analogue output
C
(optional)
base@basesistemas.com
976 587 019
https://basesistemas.com/kobold-elementos-de-instrumentacion-y-control-industrial/
All Metal Variable Area Flowmeter Model KDS
base@basesistemas.com
976 587 019
https://basesistemas.com/kobold-elementos-de-instrumentacion-y-control-industrial/
All Metal Variable Area Flowmeter Model KDS
base@basesistemas.com
976 587 019
https://basesistemas.com/kobold-elementos-de-instrumentacion-y-control-industrial/
All Metal Variable Area Flowmeter Model KDS
for gases
only
6 - 60 KDS-KL... A = % scale 0 = without
B = standard- 1 = 1 x Inductive
for gases
only
7 - 70 KDS-KM... scale H2O contact
30 = ¼" NPT
C = standard- 2 = 2 x Inductive
for gases female
only
11 - 110 KDS-KN... scale air contacts
U0 = ¼ NPT
D = % scale 3 = 1 x Inductive 0 = without
P = st. steel/ female
0.6 - 6.0 18 - 180 KDS-KC... fluid contact X = special
PTFE valve at
E = MR-scale acc. to acc. to
fitting bottom
1.0 - 10 30 - 300 KDS-KD... fluid safety specifi-
X = special O0 = ¼" NPT
F = double standard cation
female
1.6 - 16 48 - 480 KDS-KE... scale acc. E = transmitter
valve at
to specifi- 4-20 mA
top
2.5 - 25 75 - 750 KDS-KF... cation without
X = special HART®,
4,0 - 40 120 - 1200 KDS-KG... scale EEX ib
base@basesistemas.com
976 587 019
https://basesistemas.com/kobold-elementos-de-instrumentacion-y-control-industrial/
All Metal Variable Area Flowmeter Model KDS
for gases
only
6 - 60 KDS-CL... A = % scale 0 = without
B = standard- 1 = 1 x Inductive
for gases
only
7 - 70 KDS-CM... scale H2O contact
30 = ¼" NPT
C = standard- 2 = 2 x Inductive
for gases female
only
11 - 110 KDS-CN... scale air contacts
U0 = ¼ NPT
D = % scale 3 = 1 x Inductive 0 = without
P = st. steel/ female
0.6 - 6.0 18 - 180 KDS-CC... fluid contact X = special
PTFE valve at
E = MR-Scale acc. to acc. to
fitting bottom
1.0 - 10 30 - 300 KDS-CD... fluid safety specifi-
X = special O0 = ¼" NPT
F = double standard cation
female
1.6 - 16 48 - 480 KDS-CE... scale acc. E = transmitter
valve at
to specifi- 4-20 mA
top
2.5 - 25 75 - 750 KDS-CF... cation without
X = special HART®,
4.0 - 40 120 - 1200 KDS-CG... scale EEX ib
base@basesistemas.com
976 587 019
https://basesistemas.com/kobold-elementos-de-instrumentacion-y-control-industrial/
All Metal Variable Area Flowmeter Model KDS
Dimensions (mm)
KDS-K, C
min. 92
max. 102
¼" NPT
D - D (1 :
¼"NPT
100
90
80
D
70 D: 1000 kg/m³
T: 20 °C
V: 1m/Pas
60 P: 40 bar über
122
50
90
KDS
50
93
40
30
20
10
0
70 D: 1000kg/m³
77
180
T: 20 °C
V: 1 m/Pas
63 60 P: 40 bar über
115
KDS
50
D - D (1 : 1)
92,5
40
KDS-S ¼"NPT 30
20
D 10
0
22,5
100
90
2 4
80 SW
70 D: 1000kg/m³
180
T: 20 °C
V: 1 m/Pas
60 P: 40 bar über
115
KDS
50
93
40
30
20
10
0
23
base@basesistemas.com
976 587 019
https://basesistemas.com/kobold-elementos-de-instrumentacion-y-control-industrial/