Вы находитесь на странице: 1из 5

Notes

1 FOR GENERAL NOTES, HOLDS AND ABBREVIATIONS, SEE SHEET-2

Capacity Absorbed
Capacity Design Conditions Equipment Details
Unit Power
Eqpt Duty /
Eqpt No Unit Train Description Notes Remarks Revision
Type Standby
Pressure Pressure Temp Temp
Size ID / L Size TT / W Size H
kW Max Min Max Min Type Internals MOC
mm mm mm
bar (g) bar (g) °C °C

ON-PLOT EQUIPMENT

Gross Liquids : 110,000 SBPD


V-0201 Oil: 10,000 SBPD Two working Bulk separators,
V 02 - Bulk Separators 2W SBPD 8 FV 82 -29 4500 16500 Horizontal Yes Note-2
A/B Produced water: 100,000 SBPD designed for 2x50% capacity
GOR: 22 - 40 scf/bbl

Gross Liquid: 1,000-4000 SBPD


V V-0202 02 - Test Separator 1W Water cut: 0- 99.7% SBPD 8 FV 82 -29 2500 7000 Horizontal Yes Note-2
GOR: 22 - 40 scf/bbl
5740 BPD
P-0801 Desalter Crude transfer Discharge Pressure: 9.5 barg.
P 08 - 2W+1S (38 m³/h) BPD / m³/h 15.4 15.5 82 5 Centrifugal (VFD) Note-2
A/B/C Pumps Differential Head: 72 m.
Note-1

28 (Note Package includes V-0801/02, P-


Z Z-0801 08 - Desalter Package 1000 - 10000 SBPD SBPD 15.5 FV 82 5 Note-2
-3) 0802A/B & X-0801, Note-4

Discharge Pressure: 9.4 barg.


750 BPD
P-0802 Differential Head: 72 m.
P 08 - Dilution water pumps 1W+1S (5 m³/h) BPD / m³/h 2.5 15.5 82 5 Centrifugal Note-2
A/B Pumps are part of Desalter Package
Note-5
(Z-0801).
Electrostatic Coalescing
V V-0801 08 - 1W 10000 SBPD SBPD 15.5 FV 82 5 Note-3 Horizontal Yes Note-2 Part of Package Z-0801
Desalter

530 BPD
Dilution Water Surge
V V-0802 08 - 1W (3.5 m³/h) BPD / m³/h 10 FV 82 5 Note-3 Vertical Note-2 Part of Package Z-0801
drum
Note-5
530 BPD Part of Package Z-0801. Absorbed
127.2
X X-0801 08 - Dilution water Preheater 1W (3.5 m³/h) BPD / m³/h 15.5 82 5 Note-3 Plate & Frame Note-2 power of 127.2 kW is process heat
(Note -3)
Note-5 duty.

X-0802 Electric heater 2 x 100% heaters will be installed (1


X 08 - Crude Oil Heater 1W+1S 10000 SBPD SBPD 904 15.5 FV 82 5 Note-3 Note-2
A/B (Thyristor based) working & 1 stand-by)

100
Crude Oil Storage Tank Working volume: 10330 bbl mbarg + -8.5 Vertical Fixed Cone
T T-1001 A 10 - 1W bbl / m³ 82 -5 15000 11500 Note-2 Tank sized for 24 hours storage
(On-spec) (1645 m³) Liquid mbarg roof
column
100
Crude Oil Storage Tank Working volume: 10330 bbl mbarg + -8.5 Vertical Fixed Cone
T T-1001 B 10 - 1W bbl / m³ 82 -5 15000 11500 Note-2 Tank sized for 24 hours storage
(Off-spec) (1645 m³) Liquid mbarg roof
column
P-1001 Crude Oil Shipping 10400 BPD Discharge Pressure: 87 barg.
P 10 - 1W+1S BPD / m³/h 256 95 82 5 Centrifugal (VFD) Note-2
A/B Pumps (69 m³/h) Differential Head: 1121 m.

P-1003 Off spec Crude Oil 2150 BPD Discharge Pressure: 4.0 barg.
P 10 - 1W+1S BPD / m³/h 2.3 8 82 5 Centrifugal Note-2
A/B circulation Pumps (14.3 m³/h) Differential Head: 46 m.

Comprises of V-1101A/B/C, V-
Produced water 10000 – 100,000 BPD
Z Z-1101 11 - BPD / m³/h 8 82 5 1102A/B, S-1101A/B, P-1102A/B/C,
treatment package Note-3
P-1103A/B, P-1104A/B, T-1202

Discharge Pressure: 3.0 barg.


10000 – 56,800 BPD
P-1102 IGF Water transfer Centrifugal Differential Head: 29 m.
P 11 - 2W+1S (66 – 376 m³/h) BPD / m³/h 45 8 82 5
A/B /C Pumps VFD Equipment will be installed in Future
Note-3
under separate Project scope

Equipment List
DB Output. Page 3 of 7
Notes
1 FOR GENERAL NOTES, HOLDS AND ABBREVIATIONS, SEE SHEET-2

Capacity Absorbed
Capacity Design Conditions Equipment Details
Unit Power
Eqpt Duty /
Eqpt No Unit Train Description Notes Remarks Revision
Type Standby
Pressure Pressure Temp Temp
Size ID / L Size TT / W Size H
kW Max Min Max Min Type Internals MOC
mm mm mm
bar (g) bar (g) °C °C

Discharge Pressure: 4.0 barg.


10,000 BPD
P-1103 Differential Head: 39 m.
P 11 - IGF Recycle Pumps 1W+1S (66 m³/h) BPD / m³/h 17.2 8 82 5 Centrifugal
A/B Equipment will be installed in Future
Note-3
under separate Project scope

Discharge Pressure: 3.0 barg.


3000 - 10,000 BPD
P-1104 IGF Water transfer Differential Head: 29 m.
P 11 - 1W+1S (20 – 66 m³/h) BPD / m³/h 12.6 8 82 5 Centrifugal
A/B Pumps (low flow) Equipment will be installed in Future
Note - 3
under separate Project scope

10000 – 100,000 BPD


S-1101 Multi Media Filters (with Equipment will be installed in Future
S 11 - 1W+1S (66 – 665 m³/h) BPD / m³/h 8 82 5 Note-3 Vertical Yes
A/B media) under separate Project scope
Note-3

Two working CPI separators


V-1101 5000 – 50,000 BPD
V 11 - CPI Separators 2W+1S BPD / m³/h 8 FV 82 5 Note-3 Horizontal Yes Note-2 designed for 2x50% capacity. To be
A/B/C (33 – 333 m³/h)
confirmed by the vendor (Note-3).
100
Produced water break Working Volume: 132 bbl mbarg + -8.5 Vertical Fixed Cone Equipment will be installed in Future
T T-1202 12 - 1W 82 5 Note-3
tank (21 m³) Liquid mbarg roof under separate Project scope
column
P-1101 300 BPD Discharge Pressure: 4.5 barg.
P 11 - Slops Tank Pumps 1W+1S BPD / m³/h 0.4 8 82 5 Centrifugal Note-2
A/B (2 m³/h) Differential Head: 52 m.

100
Working Volume: 132 bbl mbarg + -8.5 Vertical Fixed Cone
T T-1101 11 - Slops tank 1W bbl / m³ 82 5 3000 4000 Note-2
(21 m³) Liquid mbarg roof
column
10000 – 100,000
V-1102 Equipment will be installed in Future
V 11 - IGF Vessel 1W+1S (66 – 665 m3/h) 8 FV 82 5 Note-3 Vertical Yes
A/B under separate Project scope
Note-3

P-1201 52000 BPD 1269 Discharge Pressure: 86 barg.


P 12 - Water Disposal Pumps 2W+1S BPD / m³/h 95 82 5 Centrifugal (VFD) Note-2
A/B/C (345 m³/h) (Hold-10) Differential Head: 888 m.

100
T-1201 Treated Produced Water Working volume: 25950 bbl mbarg + -8.5 Vertical Fixed Cone Two tanks (2 x 50%) provided for
T 12 - 2W bbl / m³ 82 5 24000 11300 Note-2
A/B Storage Tanks (4125 m³) Liquid mbarg roof total 12 hours storage capacity.
column
Concrete
Existing evaporation pond at Bisat-2
Existing Evaporation Working volume: 263,482 bbl lined pit
N N-1201 12 - 1W bbl / m³ Atm. 82 5 215000 105000 2600 is used for reject water and off-spec
Pond at Bisat-2 (41889 m³) (membrane
produced water disposal
liner)

Export Pipeline Scraper 10400 BPD


V V-1403 14 - 1W BPD / m³/h 95 90 5 Hold-2 CS+3mm CA
Launcher (69 m³/h)

Export Pipeline Scraper 10400 BPD


V V-1404 14 - 1W BPD / m³/h 95 90 5 Hold-2 CS+3mm CA
Receiver (69 m³/h)

Comprises of Z-1502, Z-1503, F-


Z Z-1501 15 - Flare Package 45,000 (Hold-3) Kg/h 7 FV 82 -29 Note-2
1501A/B

F-1501
F 15 - Fuel Gas Filter 1W+1S Note-3 8 82 -29 Note-3 Note-2 Part of flare package, Z-1501
A/B

Z Z-1502 15 - Flare ignition panel Note-3 Note-3 82 -29 Note-3 Note-2 Part of flare package, Z-1501

Equipment List
DB Output. Page 4 of 7
Notes
1 FOR GENERAL NOTES, HOLDS AND ABBREVIATIONS, SEE SHEET-2

Capacity Absorbed
Capacity Design Conditions Equipment Details
Unit Power
Eqpt Duty /
Eqpt No Unit Train Description Notes Remarks Revision
Type Standby
Pressure Pressure Temp Temp
Size ID / L Size TT / W Size H
kW Max Min Max Min Type Internals MOC
mm mm mm
bar (g) bar (g) °C °C
Propane gas piping
Part of flare package, Z-1501. Quads
Z Z-1503 15 - manifold and Quads 1W+1S Note-3 17.3 60 -29 Note-3 Note-2
located under shade.
package
Discharge Pressure: 4 barg.
Differential Head: 47 m.
P-1501 4.0
P 15 - Flare KOD pumps 2W Hold-3 BPD / m³/h 10 82 0 Centrifugal Note-2 Both pumps are operating; pump
A/B (Hold-4)
start/stop based on different level set
points

V V-1501 15 - Flare KOD 1W Hold-3 bbl / m³ 7 FV 82 -29 Hold-2 Horizontal Note-2

Earthern pit with


N N-1601 16 - Water pit for WSW-10 Effective volume: 100 m3 bbl / m³ Atm. 82 5 10000 10000 2000
HDPE liner

P-1701 3020 BPD Discharge Pressure: 4.0 barg.


P 17 - Utility water pumps 1W+1S BPD / m³/h 5.6 10 82 5 Centrifugal Note-2
A/B (15 m³/h) (Hold-3) Differential Head: 42 m.

Atm. +
Working volume: 1900 bbl Vertical Fixed Cone
T T-1701 17 - Utility water storage tank 1W bbl / m³ Liquid 82 5 8000 7500 Note-2
(300 m³) roof
column
Comprises of raw water tank, N+1
Water Treatment Treated water capacity: 150 75 (Note
Z Z-1701 17 - m³/d 10 82 5 Note-3 Note-2 raw water pumps, pre treatment unit,
Package m³/day -3)
RO unit, pumps, CI skids, ect.)

Z Z-1801 18 - Potable water unit 5 m³/day m³/d 10 82 5 Note-3 Note-2

Atm. +
T-2001 Vertical Fixed Cone Part of Fire Water System
T 20 - Fire Water Tanks 2W 1000 m³ (Hold-7) m³ Liquid 82 5 Hold-7 Hold-7 Note-2
A/B roof (Hold-7)
column

Fire Water Pump- 125 Part of Fire Water System


P P-2001A 20 - 1W 275 m³/h (Hold-8) m³/h 16 82 5 Centrifugal Note-2
Electric Motor Driven (Hold-8) (Hold-8)

Fire Water Pump-Diesel 125 Part of Fire Water System


P P-2001B 20 - 1S 275 m³/h (Hold-8) m³/h 16 82 5 Centrifugal Note-2
Engine Driven (Hold-8) (Hold-8)

P-2002 Jockey Pumps-Electric 8.2 Part of Fire Water System


P 20 - 1W+1S 15 m³/h (Hold-9) m³/h 16 82 5 Centrifugal Note-2
A/B Motor Driven (Hold-9) (Hold-9).

By By By
T T-2002 20 - Diesel Storage Tank By Vendor By Vendor By Vendor Part of Fire Water System
Vendor Vendor Vendor

Based 15 min residence time. Hold-


V V-2101 21 - Dry air Receiver 1W bbl / m³ 10 FV 82 0 Hold-2 Horizontal Note-2
1

1000
Total instrument air requirement is 2 W + 1S Air compressors,
Z Z-2101 21 - Instrument air package 2000 Nm3/h (170 Nm3/h for plant Nm³/h 118 16 FV 82 0 Note-3 Note-2 1W+1S Instrument air dryer and
and 1830 Nm3/h for Nitrogen filters
generation) (Hold-3)

V V-2201 22 - Nitrogen Gas Receiver 1W Hold-2 bbl / m³ 10 FV 82 0 Hold-2 Horizontal Note-2

Z Z-2201 22 - Nitrogen Generation unit 760 (Hold-3) Nm³/h 10 FV 82 0 Note-3 Note-2

Equipment List
DB Output. Page 5 of 7
Notes
1 FOR GENERAL NOTES, HOLDS AND ABBREVIATIONS, SEE SHEET-2

Capacity Absorbed
Capacity Design Conditions Equipment Details
Unit Power
Eqpt Duty /
Eqpt No Unit Train Description Notes Remarks Revision
Type Standby
Pressure Pressure Temp Temp
Size ID / L Size TT / W Size H
kW Max Min Max Min Type Internals MOC
mm mm mm
bar (g) bar (g) °C °C
Discharge Pressure: 4.0 barg.
Differential Head: 42 m.
P-2301 Closed Drain vessel 1500 BPD
P 23 - 1W+1S BPD / m³/h 4.2 10 82 5 Vertical Centrifugal Note-2 Both pumps are operating; pump
A/B pumps (10 m³/h)
start/stop based on different level set
points

V V-2301 23 - Closed Drain vessel 1W Hold-3 bbl / m³ 7 FV 82 5 Hold-2 Horizontal Note-2

Underground
N N-2401 24 - Open Drain pit Hold-3 bbl / m³ Atm. 82 5 Hold-2
Concrete pit

Underground
N N-2402 24 - Chemical Drain pit Hold-3 bbl / m³ Atm. 82 5 Hold-2
Concrete pit

1.5
P P-2401 24 - Open Drain pit pump 1W 5.0 m³/h (Hold-3) BPD / m³/h Hold-6 82 5 Vertical Centrifugal Note-2
(Hold-4)

0.4 Discharge Pressure: 1.0 barg.


P P-2402 24 - Recovered Oil pump 1W 2.0 m³/h (Hold-3) BPD / m³/h Hold-6 82 5 Note-2
(Hold-4) Differential Head: 10 m.

0.4
Z Z-2401 24 - Recovered Oil Skimmer 1W Hold-3 Atm. 82 5 Note-2
(Hold-4)

Package comprises of 1 Storage


Demulsifier Injection 0.5 15.5 Diaphragm pump
Z Z-2501 25 - Hold-3 82 5 Note-2 vessel & 2x 100 % dosing pumps.
package (Hold-4) (Hold-6) (Multi-head)
Dosing Rate by OOCEP
Package comprises of 1 Storage
Antifoam Injection 0.5 8 Diaphragm pump
Z Z-2502 25 - Hold-3 82 5 Note-2 vessel & 2x 100 % dosing pumps.
package (Hold-4) (Hold-6) (Multi-head)
Dosing Rate by OOCEP
Package comprises of 1 Storage
Scale Inhibitor Injection 0.5 8 Diaphragm pump
Z Z-2503 25 - Hold-3 82 5 Note-2 vessel & 2x 100 % dosing pumps.
package (Hold-4) (Hold-6) (Multi-head)
Dosing Rate by OOCEP
Package comprises of 1 Storage
Wax Inhibitor Injection 0.5 8
Z Z-2504 25 - Hold-3 82 5 Diaphragm pump Note-2 vessel & 2x 100 % dosing pumps.
package (Hold-4) (Hold-6)
Dosing Rate by OOCEP
Package comprises of 1 Storage
Corrosion Inhibitor 0.5 8 Diaphragm pump
Z Z-2505 25 - Hold-3 82 5 Note-2 vessel & 2x 100 % dosing pumps.
Injection package (Hold-4) (Hold-6) (Multi-head)
Dosing Rate by OOCEP
Package comprises of 1 Storage
Biocide Injection 0.25 8
Z Z-2506 25 - Hold-3 82 5 Diaphragm pump Note-2 vessel & 2x 100 % dosing pumps.
package (Hold-4) (Hold-6)
Dosing Rate by OOCEP
Package comprises of 1 Storage
De-oiling chemical 0.25 8
Z Z-2507 25 - Hold-3 82 5 Diaphragm pump Note-2 vessel & 2x 100 % dosing pumps.
Injection package (Hold-4) (Hold-6)
Dosing Rate by OOCEP
Package comprises of 1 Storage
Oxygen Scavenger 0.5 8 Diaphragm pump
Z Z-2508 25 - Hold-3 82 5 Note-2 vessel & 2x 100 % dosing pumps.
Injection package (Hold-4) (Hold-6) (Multi-head)
Dosing Rate by OOCEP

Gas: 4.2 MMSCFD MMSCFD 8


J J-2901 29 - Fuel gas Eductor FV 82 -29 Note-3 Note-3 Note-2
Motive fluid: Hold 5 / BPD (Hold-6)

Gas: 4.2 MMSCFD MMSCFD


V V-2901 29 - Fuel gas KOD 8 FV 82 -29 Hold-2 Vertical Note-2
Liquid: Hold 5 / BPD

Gas: 4.2 MMSCFD MMSCFD


V V-2902 29 - Well fluids KOD 8 FV 82 -29 Hold-2 Vertical Note-2
Liquid: 300 BPD / BPD

Equipment List
DB Output. Page 6 of 7
Notes
1 FOR GENERAL NOTES, HOLDS AND ABBREVIATIONS, SEE SHEET-2

Capacity Absorbed
Capacity Design Conditions Equipment Details
Unit Power
Eqpt Duty /
Eqpt No Unit Train Description Notes Remarks Revision
Type Standby
Pressure Pressure Temp Temp
Size ID / L Size TT / W Size H
kW Max Min Max Min Type Internals MOC
mm mm mm
bar (g) bar (g) °C °C

F&G System

UPS

OFF-PLOT EQUIPMENT

Gross Liquids: 28,000 BPD Inlets & Test port outlet: 4",
Y Y-0101 01 - Multiport Selector Valve BPD 65 82 -29 DSS
(7 wells) Trunk line port outlet: 8"

Gross Liquids: 28,000 BPD Inlets & Test port outlet: 4",
Y Y-0102 01 - Multiport Selector Valve BPD 65 82 -29 DSS
(7 wells) Trunk line port outlet: 8"

Gross Liquids: 28,000 BPD Inlets & Test port outlet: 4",
Y Y-0103 01 - Multiport Selector Valve BPD 65 82 -29 DSS
(7 wells) Trunk line port outlet: 8"

Gross Liquids: 28,000 BPD Inlets & Test port outlet: 4",
Y Y-0104 01 - Multiport Selector Valve BPD 65 82 -29 DSS
(7 wells) Trunk line port outlet: 8"

Gross Liquids: 28,000 BPD Inlets & Test port outlet: 4",
Y Y-0105 01 - Multiport Selector Valve BPD 65 82 -29 DSS
(7 wells) Trunk line port outlet: 8"

Working volume: 145 bbl Underground


N N-0101 01 - Y-0101 Drain pit bbl / m³ Atm. 82 5 Hold-2
(23 m³) Concrete pit

Working volume: 76 bbl Underground


N N-0102 01 - Y-0102 Drain pit bbl / m³ Atm. 82 5 Hold-2
(12 m³) Concrete pit

Working volume: 76 bbl Underground


N N-0103 01 - Y-0103 Drain pit bbl / m³ Atm. 82 5 Hold-2
(12 m³) Concrete pit

Working volume: 76 bbl Underground


N N-0104 01 - Y-0104 Drain pit bbl / m³ Atm. 82 5 Hold-2
(12 m³) Concrete pit

Working volume: 189 bbl Underground


N N-0105 01 - Y-0105 Drain pit bbl / m³ Atm. 82 5 Hold-2
(30 m³) Concrete pit

Equipment List
DB Output. Page 7 of 7

Вам также может понравиться