Академический Документы
Профессиональный Документы
Культура Документы
Standard Features
Cat® Engine EMCP 4 Control Panels
• Robust high speed block design provides • User-friendly interface and navigation
prolonged life and lower owning and operating • Scalable system to meet a wide range of
costs installation requirements
• Designed for maximum performance on low • Expansion modules and site specific
pressure gaseous fuel supply programming for specific customer requirements
• Simple open chamber combustion system for
Warranty
reliability and fuel flexibility
• 24 months/1000-hour warranty for standby
• High percentage of component commonality
ratings
with diesel engines
• 12 months/unlimited hour warranty for
• Conservative power density for reliability and
continuous ratings
long operational life span
• Extended service protection is available to
Generator Set Package provide extended coverage options
• Reliability verified through torsional vibration,
Worldwide Product Support
fuel consumption, oil consumption, transient
• Cat dealers have over 1,800 dealer branch
performance, and endurance testing
stores operating in 200 countries
Alternators • Your local Cat dealer provides extensive
• High-efficiency design post-sale support, including maintenance and
• Superior motor starting capability minimizes repair agreements
need for oversizing generator
Financing
• Designed to match performance and output
• Caterpillar offers an array of financial products
characteristics of Cat engines
to help you succeed through financial service
Applications excellence
• Caterpillar generator sets are capable of • Options include loans, finance lease,
maximizing power production opportunities operating lease, working capital, and revolving
in an extensive range of industries line of credit
• Contact your local Cat dealer for availability in
your region
LEXE1548-00 Page 1 of 6
G3520C Continuous
Natural Gas Generator Sets
Electric Power
Optional Equipment
Engine
Engine Generators Control System
Air Cleaner Output voltage Controller
❑ Regular duty - shipped loose ❑ 380V ❑ 6900V ❑ 600V ❑ EMCP 4.3
❑ Heavy duty - shipped loose ❑ 400V ❑ 10000V ❑ 2400V ❑ EMCP 4.4
❑ 415V ❑ 10500V ❑ 4160V Attachments
Cooling System ❑ 3300V ❑ 11000V ❑ 12470V ❑ Discrete I/O module
❑ 6300V ❑ 440V ❑ 13200V ❑ Load share module
❑ JW & SCAC engine driven
❑ 6600V ❑ 480V ❑ 13800V ❑ Local annunciator module
pumps
❑ RH JW outlet flange Temperature Rise ❑ Remote annunciator module
❑ ANSI / DIN flanges (over 40°C ambient) ❑ Remote monitoring software
LEXE1548-00 Page 2 of 6
G3520C Continuous (ADEM A3 W/ IM)
Natural Gas Generator Sets
Electric Power
LEXE1548-00 Page 3 of 6
G3520C Continuous (ADEM A3)
Natural Gas Generator Sets
Electric Power
LEXE1548-00 Page 4 of 6
G3520C Continuous (ADEM A3 W/ IM)
Natural Gas Generator Sets
Electric Power
LEXE1548-00 Page 5 of 6
G3520C Continuous
Natural Gas Generator Sets
Electric Power
A B
Ratings Definitions
Continuous Power Rating Fuel Rates
Output available with non-varying load for an 1. For transient response, ambient, and altitude capabilities
unlimited time. Average power output is 70-100% of consult your local Cat dealer.
the continuous power rating. Typical peak demand is 2. Fuel pressure range specified is to the engine fuel control
100% of continuous rated ekW for 100% of valve. Additional fuel train components may be required and
operating hours. should be considered in pressure and flow calculations.
3. For a complete reference of definitions and conditions see the
Applicable Codes and Standards
following data sheets
AS1359, CSA C22.2 No100-04, UL142,UL489,
a. 60 Hz 1600ekW Continuous / Standard (W/ Pumps)
UL869, UL2200, NFPA37, NFPA70, NFPA99, DM5855-04 (1.0g/bhp-hr NOx) - SCAC IN/OUT:130/210oF
NFPA110, IEC60034-1, ISO3046, ISO8528, NEMA DM5856-04 (0.5g/bhp-hr NOx) - SCAC IN/OUT:130/210oF
MG1-22, NEMA MG1-33, 2006/95/EC, 2006/42/EC, b. 50 Hz 1972ekW Continuous / Standard (W/ Pumps)
2004/108/ EC. EM0114-04 (500mg/Nm3 NOx) - SCAC IN/OUT:130/210oF
EM0115-04 (250mg/Nm3 NOx) - SCAC IN/OUT:130/210oF
Note: Codes may not be available in all model c. 60 Hz 2050ekW Standby / Standard (W/ Pumps)
configurations. Please consult your local Cat dealer EM4131-00 (1.0g/bhp-hr NOx) - SCAC IN/OUT: 130/194oF
for availability. EM4132-00 (0.5g/bhp-hr NOx) - SCAC IN/OUT: 130/194oF
d. 60 Hz 2050ekW Continuous / Standard (W/ Pumps)
EM0080-03 (1.0g/bhp-hr NOx) - SCAC IN/OUT: 130/194oF
EM0081-03 (0.5g/bhp-hr NOx) - SCAC IN/OUT: 130/194oF
http://www.cat.com/powergeneration
©2019 Caterpillar
All rights reserved.
Materials and specifications are subject to change without notice.
The International System of Units (SI) is used in this publication.
CAT, CATERPILLAR, LET'S DO THE WORK, their respective logos, “Caterpillar Yellow”,the
G3520C Natural Gas “Power Edge” and Cat "Modern Hex" trade dress as well as corporate and product identity used
LEXE1548-00 (8-19) herein, are trademarks of Caterpillar and may not be used without permission.