1 PK-WFZ 35 949687 10/9/2019

2 PK-WFP 21 957922 28/08/2019


3 PK-WHT 34 957999 29/09/2019

4 PK-WFO 32

5 PK-WGS

DMI OPEN TS TAB


NO REG ATA
DATE/CAT ISSUED
1 PK-WFS 79-34-1 19/6/2019

26/9/2019
2 PK-WHJ 33-41 27/9/2019
"C"

30/9/2019
3 PK-WFQ 22-18-1 30/9/2019
'B'

30/9/2019
4 PK-WGU 30-11-2 30/9/2019
'B'
HIGHLIG
ALERT NO DISCREPANCIES

SP TRICK CREW OXIGEN BOTTLE SIGN OF LEAK

103950 EXHAUST MODE FAULT IN FLIGHT


SOUND TERRAIN PULL UP SOO AT FL
103990 150 THE HIGHEST TERRAIN FOUND
062

BRAKE SYSTEM F/O SIDE R/H PEADAL


NOT WORKING

DURING AILY CHECK FOUND RED


MARKER VISIBLE AT L/H FREE FALL
ASSISTER LDG GEAR.AFTER CHECK
FOUND SIGN OF LEAK

D
DMI NO DISCREPANCIES
00018022 ENG #2 OIL LIGHT ILL

DURING PREFLIGHT FOUND ALL NAV


0031876 LIGHT NOT ILLUMINATE ( CB NAV
NORMAL SUPPLY POP OUT )

AP ON A/C WRONG DIRCTION


013313
( MISTRIM AIL )

0006708 A/F DEICING FAULT


IGHLIGHT ATR 72-
RECOMMENDATION

LEAK CHECK OF OXIGEN SYSTEM


AND REPOSITION OXY MASK
REGULATOR ASSY FOR PROPER
INSTALATION

REPLACE UNDER FLOOR


VENTILATION VLV
REPLACE RA TRANSCIVER

REPLACE MASTER CYLINDER


PN :100-25111Y00

REPLACE LH FREE FALL ASSISTER

DMI INVESTIGATE
RECOMMENDATION
REPLACE PRESS SWITCH

CONTINUE DETAIL VISUAL CHECK CABLE


FROM PLUG 5053VC UMTIL PLUG 5LA &
CHECK WAIRING FROM PLUG 5053 VC
UNTIL PLUG 5LA

CHK MSG, GRD MAINT TEST

CHK MSG, LEAK CHK

REMARK
CONTINUE TS / INPROGRESS
A/C DOCK IN AT HM BTH
AOG
OPEN
CLOSED/REOPEN
TR 72-500/600
MAINTENANCE ACTION STATUS

29/9/2019
OXYGEN PRESSURE REMAIN 1700 PSI
CONTINUE MONITOR.

30/9/2019
PERFORM LEAK CHECK OXYGEN SYSTEM
FOUND LEAK COMING FROM MONITOR
CONNECTION.PERFORM RETIGHTENED
CONNECTION C/O.LEAK CHECK NOT FOUND
LEAK.
PLEASE CONTINUE MONITOR TOMORROW.
01/10/2019
OXYGEN PRESS REMAIN 1600 PSI

PLEASE ARANGE SPARE TO A/C RON OPEN


STATION
PERFORMED REPALCE RA TRANCEIVER ,
CLOSED
RESULT GOOD

PERFORMED BLEEDING LOW PRESS,


RESULT GOOD S/S
A/C S/S

WHEN REMOVE FREE FALL ASSISTER


FOUND THREAD BOLT WAS
BROKEN.WAITING SPARE BOLT
PN : D61016
REFF IPC 32-11-12-040
S/S
PERFORMED REPLACE BOLT AND
CONFORMITY FLIGHT RESULT LDG
EMERGENCY EXTENSION FOUND GOOD

STIGATE
MAINTENANCE ACTION STATUS
REPLACE PRESS SWITCH #2 HAS BEEN
CLOSED
CARRIED OUT IAW AMM JIC 793461-RAI-10000

AFTER CHECK FOUND CABLE TO VARISTOR 19LA BROKEN,


RECTIFICATION C/O BUT TROUBLE STILL EXIST, CAN'T
CONTINUE TS DT BAD WEATHER, WILL CONTINUE TS OPEN
TONIGH,PLEASE LOCK RON A/C AT KNO STATION

PERFORM CHECK FLIGHT FAULT SUMMARY NFF, NEED ROLL


SERVO ACTUATOR CABLE OPEN

PERFORM READ MFC MAINTENANCE MEMORY NO


MESSSAGE, OPT TEST OF AIRFRAME DE ICING SYSTEM CLOSED
GOOD, DMI CLOSED
WO
REMARK
CLOSED
BOTTLE BEHIND SEAT CAPT AND LEAK CHECK
FROM OXYGEN MASK CAPT ,FO AND OBS RESULT
GOOD,NO FOUND LEAK
2. AFTER CHECK FOUND OXY PRESS 1300 PSI P'SE
MONITOR NEXT DAY
3. AFTER CHECK FOUND OXY CONECTOR AND
MASK POS OBSERVER NOT PROPER PERFOREMD
REPOSITION.LEAK CHECK FOUND NOT LEAK .
14/9/2019 PERFOREMD REPLACED OXY BOTTLE
2000 PSI.
4. 15/9/2019 OXY PRESS 1850 PSI
5. 16/9/2019 OXY PRESS 1750 PSI.PLEASE
ARRANGE TOOLS FOR LEAK CHECK
6. 17/9/2019 OXY PRESS 1700 PSI
7. 18/9/2019 CHECK AND REPOST OXY MASK CAPT
8. LEAK CHECK AT LINE OXY MASK CAPT SIDE, FO
SIDE AND OBS FOUND NO LEAK, CONTINUE
MONITOR
P'SE CONTINUE MONITOR
9. PERFORM REPLACE CAPT OXYGEN MASK C/O,
PLEASE MONITOR
SPARE RA TRANSCEIVER
PN : 9599-607-19993
NOT AVAIL AT UPG.
01 / 10/2019 RQ #414645
PLEASE ARRANGE SPARE TO A/C STA RON
INSERT TO DMI PAGE NO 012187
CAT "A" 6 FLIGHTS

AFTER TROUBLE SHOOT SUSPECTED


MASTER CYLINDER F/O SIDE WAS BAD
01 / 10/2019
FUNCTION.WAITING MASTER CYLINDER
PN :100-25111Y00

AFTER CHECK L/H FREE FALL ASSISTER


ACTUATING FOUND SIGN OF LEAK.WAITING
01 / 10/2019
TOOL NOSE AND WINGS JACK.
TEFLON WASHER PN : S6257840420600

REMARK
24/9/2019

A.PERFORMED DISCONNECTED ELECTRICAL


CONNECTOR OF ALL NAV LT ONE BY ONE RESULT
CB STIL POP OUT, CAN'T CONTINUE TS D/T EIC
FOCUS W/O HARD TIME
B.PERFORMED WIRING CHECK/ SHORT CIRCUIT
CHECK ( ASM 33-41-00 SCH 01 )
1. PIN B1 (6LV) TO GROUND : NOT CONNECTED
2. PIIN B2 (6LV) TO GROUND : NOT CONNECTED
3. PIN C1 (6LV) TO GROUND : NOT CONNECTED
4. PIN C2 (6LV) TO GROUND : NOT CONNECTED

NOTE : SWITCH NAV LT OFF POSITION


5. PERFORM DISCONNECT ELECT CONNECTION
88VC PROBLEM STILL EXIST.
6.PERFORM DISCONNECT ELECT CONNECTION
89VC PROBLEM STILL EXIST.
7. PERFORM DISCONNECT ELECT CONNECTION
5053VC FOUND CB NOT POP,LH AND RH NAV
LIGHTS ILLUMINUTE

1/10/2019
STA RON

UPG

UPG
LBJ

TKG

MDC

STA RON
HMBTH

KNO

BDO

PKY
WO
NO REG ATA WO NO
ISSUED

1 PK-WFZ 35 949687 10/9/2019

2 PK-WFP 32 959872 2/10/2019

3 PK-WGY 27 959898 2/10/2019


4 PK-WGP 23 959847 2/10/2019

5 PK-WJK 70 2/10/2019

6 PK-WFP 21 957922 28/08/2019

DMI OPEN TS TAB


NO REG ATA
DATE/CAT ISSUED

26/9/2019
1 PK-WHJ 33-41 27/9/2019
"C"

30/9/2019
2 PK-WFQ 22-18-1 30/9/2019
'B'
2/10/2019
3 PK-WGV 24
''B''
2/10/2019

2/10/2019
4 PK-WGV 28
''C''
2/10/2019
HIGHLIG
ALERT NO DISCREPANCIES

SP TRICK CREW OXIGEN BOTTLE SIGN OF LEAK

SECONDARY IND MLG UNLOCK LT


SP TRICK
REMAIN ON

SP TRICK STICK PUSHER FAULT INFLIGHT


PA SYSTEM AT STATION FA #2
SP TRICK
SOMETIME CAN'T OPERATE

DURING W.A.C LP IMPELLER FOUND


DAMAGE ENG #1

103950 EXHAUST MODE FAULT IN FLIGHT

D
DMI NO DISCREPANCIES

DURING PREFLIGHT FOUND ALL NAV


0031876 LIGHT NOT ILLUMINATE ( CB NAV
NORMAL SUPPLY POP OUT )

AP ON A/C WRONG DIRCTION


013313
( MISTRIM AIL )
DC BTC LIGHT NOT ILLUMINATE
0000085
SYSTEEM WORK NORMALLY

FUEL MISSMATCH SOMETIME


00000086 APPERAR ( R/H FUEL QTY DROP UNTIL
700 KG )
IGHLIGHT ATR 72-
RECOMMENDATION

LEAK CHECK OF OXIGEN SYSTEM


AND REPOSITION OXY MASK
REGULATOR ASSY FOR PROPER
INSTALATION

CHECK MSG AND RESIRTOR


MODULE

CHECK MSG ON AND OPT TEST OF


STICK PUSHER
REPLACE HANDSET

WAITING BOROSCOPE BY EBU


TEAM

REPLACE UNDER FLOOR


VENTILATION VLV

DMI INVESTIGATE
RECOMMENDATION

CONTINUE DETAIL VISUAL CHECK CABLE


FROM PLUG 5053VC UMTIL PLUG 5LA &
CHECK WAIRING FROM PLUG 5053 VC
UNTIL PLUG 5LA

CHK MSG, GRD MAINT TEST


REPLACE CONTACTOR 16PU

REPLACE PROBE 22 QT

REMARK
CONTINUE TS / INPROGRESS
A/C DOCK IN AT HM BTH
AOG
OPEN
CLOSED/REOPEN
TR 72-500/600
MAINTENANCE ACTION STATUS

29/9/2019
OXYGEN PRESSURE REMAIN 1700 PSI
CONTINUE MONITOR.
30/9/2019
PERFORM LEAK CHECK OXYGEN SYSTEM
FOUND LEAK COMING FROM
CONNECTION.PERFORM RETIGHTENED
CONNECTION C/O.LEAK CHECK NOT FOUND MONITOR
LEAK.
PLEASE CONTINUE MONITOR TOMORROW.
01/10/2019
OXYGEN PRESS REMAIN 1600 PSI
02/10/19
OXY PRESS REMAIN 1570 PSI

REFF WWO TS, CAN'T CHECK MESSAGE VIA


MCDU D/T MCDU BLANK (DMI) PERFORM CHECK
RESISTOR MODULE 920VR AND 921VR FOR
OPEN
INSTALLATION AND LOCKING SYSTEM NO
DEFECT. WIRING CHECK CAN'T PERFORMED D/T
LACK OF TIME

NO FEED BACK OPEN


NO FEED BACK OPEN

AFTER CHECK DIMENSION OF DEFECT FOUND


AOG
OUT OF LIMIT, WAITING MRB FOR NEXT PLAN

TRANSFER TO DMI DT WAITING PART UNDER


OPEN DMI
FLOOR VLV

STIGATE
MAINTENANCE ACTION STATUS

CAN'T PERFORM TS D/T WEATHER OPEN

REPLACEMENT ROLL SERVO CABLE IN PROGRESS, PLEASE


INPROGRESS
MONITOR
REOPEN DMI D/T WAITING SPARE CONTACTOR REOPEN

REOPEN DMI D/T WAITING SPARE FUEL PROBE REOPEN


WO
CLOSED 1. PERFORMED LEAK REMARK
CHECK FROM OXYGEN
BOTTLE BEHIND SEAT CAPT AND LEAK CHECK
FROM OXYGEN MASK CAPT ,FO AND OBS RESULT
GOOD,NO FOUND LEAK
2. AFTER CHECK FOUND OXY PRESS 1300 PSI P'SE
MONITOR NEXT DAY
3. AFTER CHECK FOUND OXY CONECTOR AND
MASK POS OBSERVER NOT PROPER PERFOREMD
REPOSITION.LEAK CHECK FOUND NOT LEAK .
14/9/2019 PERFOREMD REPLACED OXY BOTTLE
2000 PSI.
4. 15/9/2019 OXY PRESS 1850 PSI
5. 16/9/2019 OXY PRESS 1750 PSI.PLEASE
ARRANGE TOOLS FOR LEAK CHECK
6. 17/9/2019 OXY PRESS 1700 PSI
7. 18/9/2019 CHECK AND REPOST OXY MASK CAPT
8. LEAK CHECK AT LINE OXY MASK CAPT SIDE, FO
SIDE AND OBS FOUND NO LEAK, CONTINUE
MONITOR
P'SE CONTINUE MONITOR
9. PERFORM REPLACE CAPT OXYGEN MASK C/O,
PLEASE MONITOR
OXYGEN PRESS REMAIN 1400 PSI
REMARK
A.PERFORMED DISCONNECTED ELECTRICAL
CONNECTOR OF ALL NAV LT ONE BY ONE RESULT
CB STIL POP OUT, CAN'T CONTINUE TS D/T EIC
FOCUS W/O HARD TIME
B.PERFORMED WIRING CHECK/ SHORT CIRCUIT
CHECK ( ASM 33-41-00 SCH 01 )
1. PIN B1 (6LV) TO GROUND : NOT CONNECTED
2. PIIN B2 (6LV) TO GROUND : NOT CONNECTED
3. PIN C1 (6LV) TO GROUND : NOT CONNECTED
4. PIN C2 (6LV) TO GROUND : NOT CONNECTED

NOTE : SWITCH NAV LT OFF POSITION


5. PERFORM DISCONNECT ELECT CONNECTION
88VC PROBLEM STILL EXIST.
6.PERFORM DISCONNECT ELECT CONNECTION
89VC PROBLEM STILL EXIST.
7. PERFORM DISCONNECT ELECT CONNECTION
5053VC FOUND CB NOT POP,LH AND RH NAV
LIGHTS ILLUMINUTE
8. AFTER CHECK FOUND CABLE TO VARISTOR 19LA
BROKEN, RECTIFICATION C/O BUT TROUBLE STILL
PERFORM CHECK FLIGHT FAULT SUMMARY NFF, NEED ROLL
EXIST SERVO ACTUATOR CABLE
STA RON

LBJ

UPG
BDJ

UPG

STA RON

KNO

BDO
MDC

MDC
WO
NO REG ATA WO NO
ISSUED

1 PK-WFZ 35 949687 10/9/2019

2 PK-WFP 32 959872 2/10/2019

3 PK-WGY 27 959898 2/10/2019


4 PK-WGP 23 959847 2/10/2019

5 PK-WGH 26 960508 3/10/2019

6 PK-WJK 70 2/10/2019

DMI OPEN TS TAB


NO REG ATA
DATE/CAT ISSUED
26/9/2019
1 PK-WHJ 33-41 27/9/2019
"C"

30/9/2019
2 PK-WFQ 22-18-1 30/9/2019
'B'
HIGHLIG
ALERT NO DISCREPANCIES

CREW OXIGEN BOTTLE SIGN OF


SP TRICK
LEAK

SECONDARY IND MLG UNLOCK


SP TRICK
LT REMAIN ON

SP TRICK STICK PUSHER FAULT INFLIGHT


PA SYSTEM AT STATION FA #2
SP TRICK
SOMETIME CAN'T OPERATE

ENG #1 LOOP A SOMETIMES


SP TRICK
FAULT AFTER LANDING

DURING W.A.C LP IMPELLER


FOUND DAMAGE ENG #1

DM
DMI NO DISCREPANCIES
DURING PREFLIGHT FOUND ALL
0031876 NAV LIGHT NOT ILLUMINATE ( CB
NAV NORMAL SUPPLY POP OUT )

AP ON A/C WRONG DIRCTION


013313
( MISTRIM AIL )
HIGHLIGHT ATR 72-
RECOMMENDATION

LEAK CHECK OF OXIGEN SYSTEM


AND REPOSITION OXY MASK
REGULATOR ASSY FOR PROPER
INSTALATION

CHECK MSG AND RESISTOR


MODULE

CHECK MSG ON AND OPT TEST OF


STICK PUSHER
REPLACE HANDSET

DVI ALL SENSING


ELEMENTS.PRIORITY 34WD

WAITING BOROSCOPE BY EBU


TEAM

DMI INVESTIGATE
RECOMMENDATION
CONTINUE DETAIL VISUAL CHECK
CABLE FROM PLUG 5053VC UNTIL
PLUG 5LA & CHECK WAIRING FROM
PLUG 5053 VC UNTIL PLUG 5LA

CHK MSG, GRD MAINT TEST

REMARK
CONTINUE TS / INPROGRESS
A/C DOCK IN AT HM BTH
AOG
OPEN
CLOSED/REOPEN
TR 72-500/600
MAINTENANCE ACTION STATUS

03/10/2019
MONITOR
OXY PRESS REMAIN 1540 PSI

MONITOR TODAY SECONDARY IND MLG LT


OPEN
NORMAL

CAN'T CONTINUE TROUBLE SHOOT DUE TO


OPEN
GPU NOT AVAIL
OPEN DMI NO 033992 WAITING SPARE
HANDSET. CLOSED

PERFORMED DVI OF SENSING ELEMENT


29WD RESULT NO DAMAGE/NO CHAFING
31 WD RESULT NO DAMAGE/NO CHAFING
34WD RESULT NO DAMAGE/NO CHAFING
150WD RESULT NO DAMAGE/NO CHAFING MONITOR
156WD RESULT NO DAMAGE/NO CHAFING
OPT TEST OF ENG #1 FIRE DETECTION
RESULT NORMAL .
W/O CLOSED

BSI REPORT OUT OF LIMIT AREA CC LP


IMPELLER AOG
RECOVERY PLANREPLACE ENG AT BDJ

STIGATE
MAINTENANCE ACTION STATUS
AFTER TROUBLE SHOOT CABLE FROM PLUG 5053VC TO
PLUG 5LA MANY CHAFING AT SEVERAL CABLE,CAN'T OPEN
CONTINUE RECTIFIED ONE BY ONE DUE BAD WEATHER

SPARE CABLE ACTUATOR SERVO AVAIL AT BDO & STILL


WAITING ROLL SERVO FROM SUB MONITOR
1. PERFORMED LEAK CHECK FROM OXYGEN
BOTTLE BEHIND SEAT CAPT AND LEAK CHECK
FROM OXYGEN MASK CAPT ,FO AND OBS RESULT
GOOD,NO FOUND LEAK
2. AFTER CHECK FOUND OXY PRESS 1300 PSI
P'SE MONITOR NEXT DAY
WO 3. AFTER CHECK FOUND OXY CONECTOR AND
REMARK
CLOSED MASK POS OBSERVER NOT PROPER
PERFOREMD REPOSITION.LEAK CHECK FOUND
NOT LEAK .
14/9/2019 PERFOREMD REPLACED OXY BOTTLE
2000 PSI.
4. 15/9/2019 OXY PRESS 1850 PSI
5. 16/9/2019 OXY PRESS 1750 PSI.PLEASE
29/9/2019
ARRANGE TOOLS FOR LEAK CHECK
OXYGEN PRESSURE REMAIN 1700 PSI
6. 17/9/2019 OXY PRESS 1700 PSI
CONTINUE
7. 18/9/2019 CHECK MONITOR.
AND REPOST OXY MASK
CAPT 30/9/2019
8.PERFORM
LEAK CHECK LEAK CHECK
AT LINE OXYGEN
OXY MASK SYSTEM
CAPT SIDE, FO
SIDE ANDFOUND LEAKNO
OBS FOUND COMING FROM
LEAK, CONTINUE
CONNECTION.PERFORM RETIGHTENED
MONITOR
P'SE CONTINUE C/O.LEAK
CONNECTION MONITOR CHECK NOT FOUND
9. PERFORM REPLACELEAK.CAPT OXYGEN MASK C/O,
PLEASE
PLEASE MONITOR
CONTINUE MONITOR TOMORROW.
OXYGEN PRESS REMAIN 1400 PSI
01/10/2019
OXYGEN PRESS REMAIN 1600 PSI
REFF WO TS, CAN'T CHECK MESSAGE VIA MCDU
D/T MCDU BLANK02/10/19
(DMI) PERFORM CHECK
OXY PRESS
RESISTOR MODULE REMAIN 1570
920VR AND PSI FOR
921VR
INSTALLATION AND LOCKING SYSTEM NO
FOUND DEFECT. WIRING CHECK CAN'T
PERFORMED D/T LACK OF TIME
3/10/2019

3/10/2019

AFTER CHECK DIMENSION OF DEFECT FOUND


OUT OF LIMIT, WAITING MRB FOR NEXT PLAN

REMARK
A.PERFORMED DISCONNECTED ELECTRICAL
CONNECTOR OF ALL NAV LT ONE BY ONE RESULT
CB STIL POP OUT, CAN'T CONTINUE TS D/T EIC
FOCUS W/O HARD TIME
B.PERFORMED WIRING CHECK/ SHORT CIRCUIT
CHECK ( ASM 33-41-00 SCH 01 )
1. PIN B1 (6LV) TO GROUND : NOT CONNECTED
2. PIIN B2 (6LV) TO GROUND : NOT CONNECTED
3. PIN C1 (6LV) TO GROUND : NOT CONNECTED
4. PIN C2 (6LV) TO GROUND : NOT CONNECTED

NOTE : SWITCH NAV LT OFF POSITION


5. PERFORM DISCONNECT ELECT CONNECTION
88VC PROBLEM STILL EXIST.
6.PERFORM DISCONNECT ELECT CONNECTION
89VC PROBLEM STILL EXIST.
7. PERFORM DISCONNECT ELECT CONNECTION
5053VC FOUND CB NOT POP,LH AND RH NAV
LIGHTS ILLUMINUTE
8. AFTER CHECK FOUND CABLE TO VARISTOR
19LA BROKEN, RECTIFICATION C/O BUT TROUBLE
STILL EXIST
PERFORM CHECK FLIGHT FAULT SUMMARY NFF,
NEED ROLL SERVO ACTUATOR CABLE
STA RON

KOE

UPG

KNG
PLM

BPN

BDJ

STA RON
KNO

BDO
WO
NO REG ATA WO NO
ISSUED

1 PK-WFZ 35 949687 10/9/2019

2 PK-WGH 26 960508 3/10/2019


3 PK-WFP 32 959872 2/10/2019

4 PK-WGY 27 959898 2/10/2019

5 PK-WFG 34-25 960939 4/10/2019

6 PK-WFJ 23 960976 4/10/2019

7 PK-WGO 32 4/10/2019
8 PK-WJK 70 2/10/2019

DMI OPEN TS TAB


NO REG ATA
DATE/CAT ISSUED

27/9/2019

26/9/2019
1 PK-WHJ 33-41
"C"
4/10/2019

2/10/2019
2 PK-WJI 21-50-1 4/10/2019
"C"

30/9/2019
3 PK-WFQ 22-18-1 30/9/2019
'B'
HIGHLIG
ALERT NO DISCREPANCIES

CREW OXIGEN BOTTLE SIGN OF


SP TRICK
LEAK

ENG #1 LOOP A SOMETIMES


SP TRICK
FAULT AFTER LANDING
SECONDARY IND MLG UNLOCK
SP TRICK
LT REMAIN ON

SP TRICK STICK PUSHER FAULT INFLIGHT

AHRS DATA INVALID DURING


104232
TAKE OFFMONITOR DO

HF CAN'T TRANSMIT DURING


104217
INFLIGHT

AFTER LANDING AT SXK M/W #3


DEFLATE
DURING W.A.C LP IMPELLER
FOUND DAMAGE ENG #1

D
DMI NO DISCREPANCIES

DURING PREFLIGHT FOUND ALL


0031876 NAV LIGHT NOT ILLUMINATE ( CB
NAV NORMAL SUPPLY POP OUT )
LH PACK FAULT ON GROUND
013001
WITH CL IN FEATHER

AP ON A/C WRONG DIRCTION


013313
( MISTRIM AIL )
HIGHLIGHT ATR 72
RECOMMENDATION

LEAK CHECK OF OXIGEN SYSTEM


AND REPOSITION OXY MASK
REGULATOR ASSY FOR PROPER
INSTALATION

DVI ALL SENSING


ELEMENTS.PRIORITY 34WD
CHECK MSG AND RESISTOR
MODULE

CHECK MSG ON AND OPT TEST OF


STICK PUSHER

CHK MSG ON ADU,OPT TEST AHRS


AS PER TSM 34-25-00 FIG 106
,RPLC COMP 1CA

OPT TEST,BITE CONTROLLER

RPLC PCMCIA CARD & DOWN


LOAD,RPLC M/W #3 & #4
WAITING BOROSCOPE BY EBU
TEAM

DMI INVESTIGAT
RECOMMENDATION

CONTINUE DETAIL VISUAL CHECK


CABLE FROM PLUG 5053VC UNTIL
PLUG 5LA & CHECK WAIRING FROM
PLUG 5053 VC UNTIL PLUG 5LA
REMOVE BUNDLE CABLE,PUSH IN
& CHK CB,SPLICE CABLE,REPAIR
CABLE

CHK ALL DUCT CONNECTION


(CLAMP),X-CHG OR RPLC PACK
VLV

CHK MSG, GRD MAINT TEST

REMARK
CONTINUE TS / INPROGRESS
A/C DOCK IN AT HM BTH
AOG
OPEN
CLOSED/REOPEN
ATR 72-500/600
MAINTENANCE ACTION

03/10/2019
OXYGEN PRESS REMAIN 1540 PSI

04/10/2019
OXYGEN PRESS REMAIN 1540 PSI

PERFORMED DVI OF SENSING ELEMENT 34WD


RESULT NO FOUND DEFECT ,TODAY MONITOR
RESULT NORMAL
MONITOR TODAY RESULT GOOD W/O CLOSD

CAN'T CONTINUE TS DUE TO GPU NOT AVAIL AT


FKQ

MONITOR BY CREW RESULT NORMAL CHECK MSG


ON ADU RESULT NFF,CONTINUE MONITOR NEXT
FLIGHT

ALREADY INSERT DMI N0 008430 & ALREAY


REPLACE UTOMATIC ANTENNA COUPLER TEST
CONTROLL HF PANEL FOUND OK

WAITING SPARE M/W FROM UPG


NVESTIGATE
MAINTENANCE ACTION

AFTER TROUBLE SHOOT CABLE FROM PLUG 5053VC TO


PLUG 5LA MANY CHAFING AT SEVERAL CABLE,CAN'T
CONTINUE RECTIFIED ONE BY ONE DUE BAD WEATHER
PERFORMED RECTIFIED CABLE FROM 5053 VC TO PLUG 5LA
AT AREA TAILCONE FOUND MANY CHAFING,RECTIFIED
CABLE HAS BEEN GOOD ,DMI CLOSED

NO INFO FROM EIC

PERFORMED REPLACMENT A/P SERVO ACTUATOR &


ACTUATOR CABLE S (2EA) OPT TEST FOUND STATISFIED
00/600
WO
STATUS
CLOSED

MONITOR

MONITOR 3/10/2019
CLOSED 4/10/2019

OPEN

MONITOR

MONITOR

AOG
AOG

STATUS

CLOSED 3/10/2019
CLOSED 4/10/2019

OPEN

CLOSED 4/10/2019
1. PERFORMED LEAK CHECK FROM OXYGEN
BOTTLE BEHIND SEAT CAPT AND LEAK CHECK
FROM OXYGEN MASK CAPT ,FO AND OBS RESULT
GOOD,NO FOUND LEAK
2. AFTER CHECK FOUND OXY PRESS 1300 PSI P'SE
MONITOR NEXT DAY REMARK STA RON
3. AFTER CHECK FOUND OXY CONECTOR AND MASK
POS OBSERVER NOT PROPER PERFOREMD
REPOSITION.LEAK CHECK FOUND NOT LEAK .
14/9/2019 PERFOREMD REPLACED OXY BOTTLE
2000 PSI.
4. 15/9/2019 OXY PRESS 1850 PSI
5. 16/9/2019 OXY PRESS 1750 PSI.PLEASE ARRANGE
29/9/2019
TOOLS FOR LEAK CHECK
OXYGEN PRESSURE REMAIN 1700 PSI
6. 17/9/2019 OXY PRESS 1700 PSI
CONTINUE
7. 18/9/2019 CHECK MONITOR.
AND REPOST OXY MASK CAPT KOE
8. LEAK CHECK AT LINE30/9/2019
OXY MASK CAPT SIDE, FO
SIDEPERFORM LEAK CHECK
AND OBS FOUND OXYGEN
NO LEAK, SYSTEM
CONTINUE
MONITOR FOUND LEAK COMING FROM
P'SECONNECTION.PERFORM
CONTINUE MONITOR RETIGHTENED
9. CONNECTION
PERFORM REPLACE CAPT CHECK
C/O.LEAK OXYGENNOTMASK C/O,
FOUND
PLEASE MONITOR LEAK.
OXYGEN
PLEASE PRESS REMAINMONITOR
CONTINUE 1400 PSI TOMORROW.
01/10/2019
OXYGEN PRESS REMAIN 1600 PSI
PERFORMED DVI02/10/19
OF SENSING ELEMENT
29WD RESULT NO DAMAGE/NO CHAFING
OXY
31 WD PRESSNO
RESULT REMAIN 1570CHAFING
DAMAGE/NO PSI
34WD RESULT NO DAMAGE/NO CHAFING
150WD RESULT NO DAMAGE/NO CHAFING BEJ
156WD RESULT NO DAMAGE/NO CHAFING
OPT TEST OF ENG #1 FIRE DETECTION RESULT
NORMAL .
W/O CLOSED
REFF WO TS, CAN'T CHECK MESSAGE VIA MCDU D/T
MCDU BLANK (DMI) PERFORM CHECK RESISTOR
MODULE 920VR AND 921VR FOR INSTALLATION AND
LOCKING SYSTEM NO FOUND DEFECT. WIRING
CHECK CAN'T PERFORMED D/T LACK OF TIME . UPG

3/10/2019
MONITOR TODAY SECONDARY IND MLG LT NORMAL.
PLEASE CONTINUE MONITOR

FKQ

SUB

PKU

SXK
AFTER CHECK DIMENSION OF DEFECT FOUND OUT
OF LIMIT, WAITING MRB FOR NEXT PLAN
BSI REPORT OUT OF LIMIT AREA COMBUSTION BDJ
CHAMBER LP IMPELLER.
RECOVERY PLAN REPLACE ENG AT BDJ

REMARK STA RON


A.PERFORMED DISCONNECTED ELECTRICAL
CONNECTOR OF ALL NAV LT ONE BY ONE RESULT
CB STIL POP OUT, CAN'T CONTINUE TS D/T EIC
FOCUS W/O HARD TIME
B.PERFORMED WIRING CHECK/ SHORT CIRCUIT
CHECK ( ASM 33-41-00 SCH 01 )
1. PIN B1 (6LV) TO GROUND : NOT CONNECTED
2. PIIN B2 (6LV) TO GROUND : NOT CONNECTED
3. PIN C1 (6LV) TO GROUND : NOT CONNECTED
4. PIN C2 (6LV) TO GROUND : NOT CONNECTED

NOTE : SWITCH NAV LT OFF POSITION


5. PERFORM DISCONNECT ELECT CONNECTION
88VC PROBLEM STILL EXIST. KNO
6.PERFORM DISCONNECT ELECT CONNECTION
89VC PROBLEM STILL EXIST.
7. PERFORM DISCONNECT ELECT CONNECTION
5053VC FOUND CB NOT POP,LH AND RH NAV LIGHTS
ILLUMINUTE
8. AFTER CHECK FOUND CABLE TO VARISTOR 19LA
BROKEN, RECTIFICATION C/O BUT TROUBLE STILL
EXIST
PERFORM CHECK FLIGHT FAULT SUMMARY NFF,
BDO
NEED ROLL SERVO ACTUATOR CABLE
WO
NO REG ATA WO NO
ISSUED

1 PK-WFZ 35 949687 10/9/2019


2 PK-WGH 26 960508 3/10/2019

3 PK-WGY 27 959898 2/10/2019


4 PK-WFG 34-25 960939 4/10/2019

5 PK-WFJ 23 960976 4/10/2019

6 PK-WGO 32 4/10/2019

7 PK-WJK 70 2/10/2019

DMI OPEN TS TAB


NO REG ATA
DATE/CAT ISSUED

2/10/2019
1 PK-WJI 21-50-1 4/10/2019
"C"
3/10/2019
2 PK-WFG 33-43-1 5/10/2019
"C"
HIGHLIG
ALERT NO DISCREPANCIES

CREW OXIGEN BOTTLE SIGN OF


SP TRICK
LEAK
ENG #1 LOOP A SOMETIMES
SP TRICK
FAULT AFTER LANDING

SP TRICK STICK PUSHER FAULT INFLIGHT


AHRS DATA INVALID DURING
104232
TAKE OFFMONITOR DO

HF CAN'T TRANSMIT DURING


104217
INFLIGHT

AFTER LANDING AT SXK M/W #3


DEFLATE

DURING W.A.C LP IMPELLER


FOUND DAMAGE ENG #1

D
DMI NO DISCREPANCIES

LH PACK FAULT ON GROUND


013001
WITH CL IN FEATHER
00033949 RH STROBE LT CB POPOUT
HIGHLIGHT ATR 72
RECOMMENDATION

LEAK CHECK OF OXIGEN SYSTEM


AND REPOSITION OXY MASK
REGULATOR ASSY FOR PROPER
INSTALATION
DVI ALL SENSING
ELEMENTS.PRIORITY 34WD

CHECK MSG ON AND OPT TEST OF


STICK PUSHER
CHK MSG ON ADU,OPT TEST AHRS
AS PER TSM 34-25-00 FIG 106
,RPLC COMP 1CA

OPT TEST,BITE CONTROLLER

RPLC PCMCIA CARD & DOWN


LOAD,RPLC M/W #3 & #4

REPLACE ENGINE

DMI INVESTIGAT
RECOMMENDATION

CHK ALL DUCT CONNECTION


(CLAMP),X-CHG OR RPLC PACK
VLV
DISCONNECT ELECT CONNECTOR
OF POWER SUPPLY, REPLACE
POWER SUPPLY, WIRING CHECK

REMARK
CONTINUE TS / INPROGRESS
A/C DOCK IN AT HM BTH
AOG
OPEN
CLOSED/REOPEN
ATR 72-500/600
MAINTENANCE ACTION STATUS

AFTER MONITOR 5 DAYS, RESULT GOOD CLOSED


AFTER MONITOR 2 DAYS RESULT NORMAL CLOSED

NO FEED BACK FROM EIC OPEN


MONITOR TODAY RESULT GOOD, P'SE CONTINUE
MONITOR
MONITOR

MONITOR TODAY RESULT GOOD, P'SE CONTINUE


MONITOR
MONITOR

PERFORMED REPLACE M/W AND BRAKE #3 & #4 SERVICEABLE


C/O. A/C DECLARE SS

WAITING ENGINE SHIPMENT AOG

ESTIGATE
MAINTENANCE ACTION STATUS

PERFORMD EXCHANGE HP VALVE , EGR RESULT GOOD MONITOR


PERFORMED REPLACE PWER SUPPLY, RESULT GOOD DMI
CLOSED CLOSED
WO
REMARK
CLOSED

1. PERFORMED LEAK CHECK FROM OXYGEN


BOTTLE BEHIND SEAT CAPT AND LEAK CHECK
FROM OXYGEN MASK CAPT ,FO AND OBS RESULT
GOOD,NO FOUND LEAK
2. AFTER CHECK FOUND OXY PRESS 1300 PSI P'SE
MONITOR NEXT DAY
3. AFTER CHECK FOUND OXY CONECTOR AND
MASK POS OBSERVER NOT PROPER PERFOREMD
REPOSITION.LEAK CHECK FOUND NOT LEAK .
14/9/2019 PERFOREMD REPLACED OXY BOTTLE
2000 PSI.
4. 15/9/2019 OXY PRESS 1850 PSI
5. 16/9/2019 OXY PRESS 1750 PSI.PLEASE
ARRANGE TOOLS FOR LEAK CHECK
6. 17/9/2019 OXY PRESS 1700 PSI
7. 18/9/2019 CHECK AND REPOST OXY MASK CAPT
8. LEAK CHECK AT LINE OXY MASK CAPT SIDE, FO
SIDE AND OBS FOUND NO LEAK, CONTINUE
MONITOR
P'SE CONTINUE MONITOR
05/10/2019
9. PERFORM REPLACE CAPT OXYGEN MASK C/O,
PLEASE MONITOR
OXYGEN PRESS REMAIN 1400 PSI
29/9/2019
OXYGEN PRESSURE REMAIN 1700 PSI
CONTINUE MONITOR.
30/9/2019
OXYGEN PRESSURE REMAIN 1700 PSI
CONTINUE MONITOR.
30/9/2019
PERFORM LEAK CHECK OXYGEN SYSTEM FOUND
LEAK COMING FROM CONNECTION.PERFORM
RETIGHTENED CONNECTION C/O.LEAK CHECK NOT
FOUND LEAK.
PLEASE CONTINUE MONITOR TOMORROW.
01/10/2019
OXYGEN PRESS REMAIN 1600 PSI
02/10/19
OXY PRESS REMAIN 1570 PSI
03/10/2019
OXYGEN PRESS REMAIN 1540 PSI
04/10/2019
OXYGEN PRESS REMAIN 1540 PSI

PERFORMED DVI OF SENSING ELEMENT


29WD RESULT NO DAMAGE/NO CHAFING
31 WD RESULT NO DAMAGE/NO CHAFING
34WD RESULT NO DAMAGE/NO CHAFING
05/10/2019 150WD RESULT NO DAMAGE/NO CHAFING
156WD RESULT NO DAMAGE/NO CHAFING
OPT TEST OF ENG #1 FIRE DETECTION RESULT
NORMAL .
W/O CLOSED
MONITOR BY CREW RESULT NORMAL CHECK MSG
ON ADU RESULT NFF,CONTINUE MONITOR NEXT
FLIGHT

ALREADY INSERT DMI N0 008430 & ALREADY


REPLACE UTOMATIC ANTENNA COUPLER TEST
CONTROLL HF PANEL FOUND OK

WAITING SPARE M/W FROM UPG

AFTER CHECK DIMENSION OF DEFECT FOUND OUT


OF LIMIT, WAITING MRB FOR NEXT PLAN
BSI REPORT OUT OF LIMIT AREA COMBUSTION
CHAMBER LP IMPELLER.
RECOVERY PLAN REPLACE ENG AT BDJ

REMARK
05/10/2019
STA RON

RTE
BEJ
SUB

PKU

BDJ

STA RON

KOE
SUB
WO
NO REG ATA WO NO
ISSUED

1 PK-WGY 27 959898 2/10/2019

2 PK-WFG 34-25 960939 4/10/2019

3 PK-WFJ 23 960976 4/10/2019

4 PK-WJK 70 2/10/2019

5 PK-WFH 27 6/10/2019
DMI OPEN TS TAB
NO REG ATA
DATE/CAT ISSUED

2/10/2019
1 PK-WJI 21-50-1 4/10/2019
"C"

4/10/2019
2 PK-WFJ 27-65-1 6/10/2019
"C"

5/10/2019
3 PK-WGJ 26-12-1 6/10/2019
"C"

2/10/2019
4 PK-WGT 33-41-1 6/10/2019
"C"

4/10/2019
5 PK-WGG 23-11-1 6/10/2019
"D"
HIGHLIG
ALERT NO DISCREPANCIES

SP TRICK STICK PUSHER FAULT INFLIGHT

AHRS DATA INVALID DURING


104232
TAKE OFFMONITOR DO

HF CAN'T TRANSMIT DURING


104217
INFLIGHT

DURING W.A.C LP IMPELLER


FOUND DAMAGE ENG #1

DURING P.F.C FOUND FLAP


MOVED TO DOWN POSITION
D
DMI NO DISCREPANCIES

LH PACK FAULT ON GROUND


013001
WITH CL IN FEATHER

LH SPOILER INDICATOR NOT


008431
ILLUMINATE

0018695 LOOP A ENG 2 NOT WORKING

002436 TAIL NAV LT BLINKING

0032080 HF FAIL
HIGHLIGHT ATR 72
RECOMMENDATION

CHECK MSG ON MCDU AND OPT


TEST OF STICK PUSHER

CHK MSG ON ADU,OPT TEST AHRS


AS PER TSM 34-25-00 FIG 106
,RPLC COMP 1CA

OPT TEST,BITE CONTROLLER

REPLACE ENGINE

REPLACE FLAP BLOCK VLV, CHECK


FLAP ACTUATOR FOR INTERNAL
LEAKAGE
DMI INVESTIGAT
RECOMMENDATION

CHK ALL DUCT CONNECTION


(CLAMP),X-CHG OR RPLC PACK
VLV

REPLACE 5CT PROX SWITCH,


POWER CHECK,WIRING CHECK

DVI AND RESISTANCE CHECK OF


SENSING ELEMENTS

REFF DO CHAP 33-41 PARHA 3.


OPERATION, WILL BY REPLACE AT
NEXT C CHECK PLEASE CLOSED
THE DMI

CHECK MSG, CONTINUE


TROUBLESHOOT AS PER
MESSAGE

REMARK
CONTINUE TS / INPROGRESS
A/C DOCK IN AT HM BTH
AOG
OPEN
CLOSED/REOPEN
ATR 72-500/600
MAINTENANCE ACTION STATUS

NO INFO FROM EIC OPEN

MONITOR

MONITOR

WAITING ENGINE SHIPMENT AOG

WAITING SPARE FLAP BLOCK VALVE AOG


ESTIGATE
MAINTENANCE ACTION STATUS

AFTER MONITOR 1 DAY GOOD, GROUND IDLE RUN DMI CLOSED


FOUND LH PACK NO FAULT DMI CLOSED

AFTER REPLACE PROXIMITY 5 CT PROBLEM STILL,


WIRING CHECK 28 VDC AT PLUG PROXIMITY 5CT OPEN
PIN A TO C FOUND 28VDC, PIN B TO C INTERMITEN

DURING DVI CHECK FOUND BOBIN AND CLAMP


LOOP SENSING ELEMENT 30WD NOT PROPER,
REINSTALLATION OF CLAMP AND BOBIN FOR DMI CLOSED
PROPER INSTALLATION C/. OPT TEST GOOD, DMI
CLOSED

REFF DO CHAP 33-41 PARHA 3. OPERATION, WILL DMI CLOSED


BY REPLACE AT NEXT C CHECK DMI CLOSE

MSG FOUND 1RE2 , REPOST AND CLEAN OPT TEST


MONITOR
HF FOUND GOOD CONTIUNUE MONITOR
WO
REMARK
CLOSED

MONITOR BY CREW RESULT NORMAL CHECK MSG


ON ADU RESULT NFF,CONTINUE MONITOR NEXT
FLIGHT

ALREADY INSERT DMI N0 008430 & ALREADY


REPLACE AUTOMATIC ANTENNA COUPLER TEST
CONTROLL HF PANEL FOUND OK

AFTER CHECK DIMENSION OF DEFECT FOUND OUT


OF LIMIT, WAITING MRB FOR NEXT PLAN
BSI REPORT OUT OF LIMIT AREA COMBUSTION
CHAMBER LP IMPELLER.
RECOVERY PLAN REPLACE ENG AT BDJ
REMARK

6/10/2019 PERFORMD EXCHANGE HP VALVE , EGR RESULT GOOD

6/10/2019

6/10/2019
STA RON

SUB

TKG

BDJ

GNS
STA RON

SWQ

TKG

BDJ

SRG

UPG
NO REG ATA WO NO

1 PK-WGY 27 959898

2 PK-WHH 27 961464

3 PK-WFG 34-25 960939


4 PK-WFJ 23 960976

5 PK-WJK 70

6 PK-WFH 27

DMI OPEN
NO REG ATA
DATE/CAT

4/10/2019
1 PK-WFJ 27-65-1
"C"
4/10/2019
2 PK-WGG 23-11-1
"D"

6/10/2019
3 PK-WGK 26-12-1
''C''
H
WO
ALERT NO
ISSUED

2/10/2019 SP TRICK

7/10/2019 SP TRICK

4/10/2019 104232
4/10/2019 104217

2/10/2019

6/10/2019

TS TAB
DMI NO
ISSUED

6/10/2019 008431
6/10/2019 0032080

6/10/2019 00024953
HIGHLIGHT
DISCREPANCIES

STICK PUSHER FAULT INFLIGHT

AILERON TRIM INDICATOR


SOMETIMES CROSS AMBER

AHRS DATA INVALID DURING TAKE


OFF MONITOR DO
HF CAN'T TRANSMIT DURING
INFLIGHT

DURING W.A.C LP IMPELLER


FOUND DAMAGE ENG #1

DURING P.F.C FOUND FLAP


MOVED TO DOWN POSITION

DMI
DISCREPANCIES

LH SPOILER INDICATOR NOT


ILLUMINATE
HF FAIL

LOOP A ENG 1 FAULT


HIGHLIGHT ATR 72-
RECOMMENDATION

CHECK MSG ON MCDU AND OPT


TEST OF STICK PUSHER

X CHANGE AILERON TRIM ACT


WITH TLU ACT

CHK MSG ON ADU,OPT TEST AHRS


AS PER TSM 34-25-00 FIG 106
,RPLC COMP 1CA
OPT TEST,BITE CONTROLLER

REPLACE ENGINE

REPLACE FLAP BLOCK VLV,


CHECK FLAP ACTUATOR FOR
INTERNAL LEAKAGE

DMI INVESTIGATE
RECOMMENDATION

REPLACE 5CT PROX SWITCH,


POWER CHECK,WIRING CHECK
CHECK MSG, CONTINUE
TROUBLESHOOT AS PER
MESSAGE

DVI AND RESISTANCE CHECK OF


SENSING ELEMENTS

REMARK
CONTINUE TS / INPROGRESS

A/C DOCK IN AT HM BTH


AOG
OPEN
CLOSED/REOPEN
ATR 72-500/600
MAINTENANCE ACTION

NO INFO FROM EIC

CHECK AILERON ACTUATOR DECISSANT CARTRIDGE


COLOUR WHITE.PERFORM X-CHG AILERON TRIM
ACTUATOR WITH TLU ACTUATOR C/O.OPT TEST FOUND
GOOD.PLEASE MONITOR INFLIGHT
WO CLOSED

FLIGHT FAULT SUMMARY :


- SVO SWNG MON (A)
- SVO SWNG MON (B)
OPT TEST OF AHRS FOUND GOOD.
FGC TEST FOUND PASS.
PLEASE ARRANGE SPARE AP COMPUTER 1CA
PN : 7003947-606
FOR TROUBLE SHOOT.
REFF TRAX AVAIL AT P5
AFTER MONITOR TODAY HF SYSTEM WAS NORMAL .
W/O CLOSED

WAITING ENGINE SHIPMENT

WAITING BLEEDING TOOLS FROM DJJ


P/N : 98S27505001000

ESTIGATE
MAINTENANCE ACTION

CAN'T PERFORM D/T AVO METER NOT AVAIL AT PLM


INFO FROM EIC KRISNA HF HAS BEEN GOOD AFTER
REPOSITION 1RE.
CONTINUE MONITOR BEFORE CLOSE DMI
TOMORROW

AFTER MONITOR TODAY AND OPT TEST FOUND GOOD.


EIC REQUEST MONITOR BEFORE CLOSE DMI
TOMORROW
600
WO
STATUS
CLOSED

OPEN

MONITOR

MONITOR
W/O CLOSED 7/10/2019

AOG

AOG

STATUS

OPEN
MONITOR

MONITOR
REMARK STA RON

JOG

MONITOR BY CREW RESULT NORMAL CHECK


MSG ON ADU RESULT NFF,CONTINUE MONITOR BDO
NEXT FLIGHT
ALREADY INSERT DMI N0 008430 & ALREADY
REPLACE AUTOMATIC ANTENNA COUPLER TEST PLM
CONTROLL HF PANEL FOUND OK

AFTER CHECK DIMENSION OF DEFECT FOUND


OUT OF LIMIT, WAITING MRB FOR NEXT PLAN
BSI REPORT OUT OF LIMIT AREA COMBUSTION
CHAMBER LP IMPELLER. BDJ
RECOVERY PLAN REPLACE ENG AT
BDJ

WAITING SPARE FLAP BLOCK VALVE GNS

REMARK STA RON

AFTER REPLACE PROXIMITY 5CT PROBLEM


STILL, WIRING CHECK 28 VDC AT PLUG
PLM
PROXIMITY 5CT PIN A TO C FOUND 28VDC, PIN B
TO C INTERMITEN
MSG FOUND 1RE2 , REPOST AND CLEAN OPT
BDJ
TEST HF FOUND GOOD CONTIUNUE MONITOR

SUB
WO
NO REG ATA WO NO
ISSUED

1 PK-WGY 27 959898 2/10/2019

2 PK-WFG 34-25 960939 4/10/2019


3 PK-WHH 27 961464 7/10/2019

4 PK-WFH 27 6/10/2019

5 PK-WJK 70 2/10/2019

DMI OPEN TS TAB


NO REG ATA
DATE/CAT ISSUED
4/10/2019
1 PK-WFJ 27-65-1 6/10/2019
"C"

4/10/2019
2 PK-WGG 23-11-1 6/10/2019
"D"

6/10/2019
3 PK-WGK 26-12-1 6/10/2019
''C''
HIGHLIG
ALERT NO DISCREPANCIES

SP TRICK STICK PUSHER FAULT INFLIGHT

AHRS DATA INVALID DURING TAKE


104232
OFF MONITOR DO
AILERON TRIM INDICATOR
SP TRICK
SOMETIMES CROSS AMBER

DURING P.F.C FOUND FLAP MOVED


TO DOWN POSITION

DURING W.A.C LP IMPELLER


FOUND DAMAGE ENG #1

D
DMI NO DISCREPANCIES
LH SPOILER INDICATOR NOT
008431
ILLUMINATE

0032080 HF FAIL

00024953 LOOP A ENG 1 FAULT


HIGHLIGHT ATR 72
RECOMMENDATION

CHECK MSG ON MCDU AND OPT


TEST OF STICK PUSHER

CHK MSG ON ADU,OPT TEST


AHRS AS PER TSM 34-25-00 FIG
106 ,RPLC COMP 1CA
X CHANGE AILERON TRIM ACT
WITH TLU ACT

REPLACE FLAP BLOCK VLV,


CHECK FLAP ACTUATOR FOR
INTERNAL LEAKAGE

REPLACE ENGINE

DMI INVESTIGAT
RECOMMENDATION
REPLACE 5CT PROX SWITCH,
POWER CHECK,WIRING CHECK

CHECK MSG, CONTINUE


TROUBLESHOOT AS PER
MESSAGE

DVI AND RESISTANCE CHECK OF


SENSING ELEMENTS
REMARK

CONTINUE TS / INPROGRESS

A/C DOCK IN AT HM BTH


AOG
OPEN
CLOSED/REOPEN
ATR 72-500/600
MAINTENANCE ACTION

NO INFO FROM EIC

SPARE AP COMPUTER NOT AVAIL AT JOG.


SPARE AP COMPUTER ALREADY AT SUB.
PLEASE ARRANGE SPARE TO A/C STA RON
AFTER MONITOR TODAY AILERON TRIM INDICATION
WAS NORMAL.
W/O CLOSED

PERFORMED REPLACE FLAP BLOCK VALVE AND


BLEEDING FLAP ACTUATOR OPT TEST RESULT
GOOD (NO LEAK).
A/C SERVICEABLE

WAITING ENGINE SHIPMENT

ESTIGATE
MAINTENANCE ACTION
1. PERFORM REPLACE PROX SWITCH 5CT PROBLEM STILL
EXIST.SPARE BACK TO ORIGINAL
2. CHK PWR BETWEEN PIN A TO GROUND FOUND 27 VDC.
3. X-CHANGE DIODE 35VD WITH 25VD PROBLEM STILL EXIST ON
LH SPOILER.BACK TO ORIGINAL.
4. PERFORM CHK PWR PIN B TO GROUND HAS 24DC ON
CONNECTOR 5CT
REFF ASM 27-65-00 SCH 01 P 101 FIG 1
5. PERFORM CHECK DIODE ON 35VD PIN 30 AND 15 RESULT
CONDITION DIODE GOOD.
6. PERFORM CHECK DIODE ON 10VU CONNECTOR 5VC PIN 30
AND 53 RESULT CONDITION DIODE GOOD.
7. PERFORM X-CHANGE PANEL MODULE FOR POSSIBILITY
OPEN CIRCUIT ON CORY AND ASSOCIATED WIRING ON PANEL
MODULE.OPT TEST PROBLEM STILL EXIST.
PLEASE CONTINUE NEXT TROUBLE SHOOT

AFTER MONITOR PROBLEM STILL EXIST.


PERFORM CHECK CONNECTION 1RE2 TO 3WK1 FOUND GOOD.
PERFORM CLEAN FIBRE OPTIC CABLE C/O.
PLEASE CONTINUE MONITOR

AFTER MONITOR TODAY AND OPT TEST FOND GOOD.


DVI ALL SENSING ELEMENT FOUND GOOD.
DMI CLOSED
600
WO
STATUS
CLOSED

OPEN

MONITOR
W/O 8/10/2019
CLOSED

CLOSED 8/10/2019

AOG

STATUS
OPEN

MONITOR

CLOSED 8/10/209
REMARK STA RON

MONITOR BY CREW RESULT NORMAL


CHECK MSG ON ADU RESULT
NFF,CONTINUE MONITOR NEXT FLIGHT
FLIGHT FAULT SUMMARY :
- SVO SWNG MON (A)
- SVO SWNG MON (B)
OPT TEST OF AHRS FOUND GOOD. JOG
FGC TEST FOUND PASS.
PLEASE ARRANGE SPARE AP COMPUTER
1CA
PN : 7003947-606
FOR TROUBLE SHOOT.
REFF TRAX AVAIL AT P5
CHECK AILERON ACTUATOR DECISSANT
CARTRIDGE COLOUR WHITE.PERFORM X-
CHG AILERON TRIM ACTUATOR WITH TLU
ACTUATOR C/O.OPT TEST FOUND PKY
GOOD.PLEASE MONITOR INFLIGHT
WO CLOSED

WAITING SPARE FLAP BLOCK VALVE GNS

AFTER CHECK DIMENSION OF DEFECT


FOUND OUT OF LIMIT, WAITING MRB FOR
NEXT PLAN
BSI REPORT OUT OF LIMIT AREA
COMBUSTION CHAMBER LP IMPELLER. BDJ
RECOVERY PLAN REPLACE
ENG AT BDJ

REMARK STA RON


AFTER REPLACE PROXIMITY 5CT
PROBLEM STILL EXIST.BACK TO
ORIGINAL.
WIRING CHECK 28 VDC AT PLUG PKU
PROXIMITY 5CT PIN A TO C FOUND 28VDC,
PIN B TO C INTERMITEN

MSG FOUND 1RE2 , REPOST AND CLEAN


OPT TEST HF FOUND GOOD CONTIUNUE
MONITOR
INFO FROM EIC KRISNA HF HAS BEEN BUW
GOOD AFTER REPOSITION 1RE.
CONTINUE MONITOR BEFORE CLOSE DMI
TOMORROW

AFTER MONITOR TODAY AND OPT TEST


FOUND GOOD.
EIC REQUEST MONITOR BEFORE
SUB
CLOSE DMI TOMORROW
NO REG ATA WO NO

1 PK-WGY 27 959898

2 PK-WJI 52-31 962863


3 PK-WFG 34-25 960939

4 PK-WJK 70
DMI OPEN
NO REG ATA
DATE/CAT

4/10/2019
1 PK-WFJ 27-65-1
"C"

4/10/2019
2 PK-WGG 23-11-1
"D"
HIGH
WO
ALERT NO
ISSUED

2/10/2019 SP TRICK

9/10/2019 104427
4/10/2019 104232

2/10/2019
TS TAB
DMI NO
ISSUED

6/10/2019 008431

6/10/2019 0032080
HIGHLIGHT
DISCREPANCIES

STICK PUSHER FAULT INFLIGHT

CARGO DOOR UNABLE


ELECTRICAL OPEN
AHRS DATA INVALID DURING TAKE
OFF MONITOR DO

DURING W.A.C LP IMPELLER


FOUND DAMAGE ENG #1

DMI IN
DISCREPANCIES

LH SPOILER INDICATOR NOT


ILLUMINATE

HF FAIL
GHLIGHT ATR 72-5
RECOMMENDATION

CHECK MSG ON MCDU AND OPT


TEST OF STICK PUSHER

REPLACE CARGO DOOR ACTUATOR


CHK MSG ON ADU,OPT TEST AHRS
AS PER TSM 34-25-00 FIG 106 ,RPLC
COMP 1CA

REPLACE ENGINE

DMI INVESTIGATE
RECOMMENDATION

REPLACE 5CT PROX SWITCH,


POWER CHECK,WIRING CHECK

CHECK MSG, CONTINUE


TROUBLESHOOT AS PER MESSAGE,
INSTALL FIBER OPTIC FROM HF#1
(SPARE )
REMARK

CONTINUE TS / INPROGRESS

A/C DOCK IN AT HM BTH


AOG
OPEN
CLOSED/REOPEN
ATR 72-500/600
MAINTENANCE ACTION

NO FEED BACK

CAN'T PERFORM DT SPARE STILL AT


HMSUB, PLEASE MONITOR FOR
REPOSITION SPARE FROM HMSUB TO
LMSUB
CAN'T PERFOR, DT SPARE NOT AVAIL AT BDO,
PLEASE ARRANGE SPARE AFCS COMP TO
CONTINUE TS

ON PROGRESS ENGINE REPLACEMENT

NVESTIGATE
MAINTENANCE ACTION

FOR REMAKSURE, DO POWER CHECK AT PIN A CONNECTOR


PLUG 5CTA FOUND 28VDC
-PERFORM CONTINUITY CHECK PIN C AT ELECT CONNECTOR
5CTA TO GROUND FOUND CONNECT
-PERFORM CONTINUITY CHECK PIN B AT ELECT CONNECTOR
5CTA TO PIN 15 AT DIODE 35VD FOUND NOT CONNECT
-CAN'T CONTINUE TS DT LACK OF MAN POWER, EIC HANDLE
ANOTHER 2 AIRCRAFT

PERFORM XCHANGE FIBER OPTIC HF COUPLER AND


TRANCEIVER WITH SPARE, PLEASE MONITOR
WO
STATUS
CLOSED

OPEN

OPEN
OPEN

AOG
STATUS

OPEN

MONITOR
REMARK STA RON

SUB
MONITOR BY CREW RESULT NORMAL CHECK
MSG ON ADU RESULT NFF,CONTINUE
MONITOR NEXT FLIGHT
FLIGHT FAULT SUMMARY :
- SVO SWNG MON (A)
- SVO SWNG MON (B) BDO
OPT TEST OF AHRS FOUND GOOD.
FGC TEST FOUND PASS.
PLEASE ARRANGE SPARE AP COMPUTER 1CA
PN : 7003947-606
FOR TROUBLE SHOOT.

AFTER CHECK DIMENSION OF DEFECT FOUND


OUT OF LIMIT, WAITING MRB FOR NEXT PLAN
BSI REPORT OUT OF LIMIT AREA COMBUSTION
CHAMBER LP IMPELLER. BDJ
RECOVERY PLAN REPLACE ENG
AT BDJ
REMARK STA RON
AFTER REPLACE PROXIMITY 5CT PROBLEM
STILL EXIST.BACK TO ORIGINAL.
WIRING CHECK 28 VDC AT PLUG PROXIMITY
5CT PIN A TO C FOUND 28VDC, PIN B TO C
INTERMITEN
1. PERFORM REPLACE PROX SWITCH 5CT
PROBLEM STILL EXIST.SPARE BACK TO
ORIGINAL
2. CHK PWR BETWEEN PIN A TO GROUND
FOUND 27 VDC.
3. X-CHANGE DIODE 35VD WITH 25VD PKU
PROBLEM STILL EXIST ON LH SPOILER.BACK
TO ORIGINAL.
4. PERFORM CHK PWR PIN B TO GROUND HAS
24DC ON CONNECTOR 5CT
REFF ASM 27-65-00 SCH 01 P 101 FIG 1
5. PERFORM CHECK DIODE ON 35VD PIN 30
AND 15 RESULT CONDITION DIODE GOOD.
6. PERFORM CHECK DIODE ON 10VU
CONNECTOR 5VC PIN 30 AND 53 RESULT
CONDITION DIODE GOOD.
7. PERFORM X-CHANGE PANEL MODULE FOR
POSSIBILITY OPEN CIRCUIT ON CORY AND
MSG FOUND 1RE2
ASSOCIATED , REPOST
WIRING ANDMODULE.OPT
ON PANEL CLEAN OPT
TEST
TEST HF FOUNDSTILL
PROBLEM GOODEXIST.
CONTIUNUE MONITOR
INFO
PLEASEFROM EIC KRISNA
CONTINUE HF
NEXT HAS BEEN
TROUBLE GOOD
SHOOT BPN
AFTER REPOSITION 1RE. MONITOR STILL
EXIST
WO
NO REG ATA WO NO
ISSUED

1 PK-WGY 27 959898 2/10/2019

2 PK-WJI 52-31 962863 9/10/2019


3 PK-WFG 34-25 960939 4/10/2019

4 PK-WGH 26-12 963613 10/10/2019


5 PK-WFQ 34-25 963694 10/10/2019

6 PK-WJK 70 2/10/2019
7 PK-WFM 72 10/10/2019

DMI OPEN TS TAB


NO REG ATA
DATE/CAT ISSUED
4/10/2019
10 PK-WFJ 27-65-1 6/10/2019
"C"

4/10/2019
2 PK-WGG 23-11-1 6/10/2019
"D"

9/10/2019
3 PK-WFK 31-31 10/10/2019
"C"
HIGHLI
ALERT NO DISCREPANCIES

SP TRICK STICK PUSHER FAULT INFLIGHT

CARGO DOOR UNABLE


104427
ELECTRICAL OPEN
AHRS DATA INVALID DURING TAKE
104232
OFF MONITOR DO

LOOP A ENGINE #1 FAULT


SP TRICK
INTERMITTENT
EFIS COMP SOMETIMES
SP TRICK
ILLUMINATE

DURING W.A.C LP IMPELLER


FOUND DAMAGE ENG #1
ENG #2 CAN'T ACHIEVE TK OFF
POWER (ONLY ACHIEVE 81%) AT
BDO

DMI NO DISCREPANCIES
LH SPOILER INDICATOR NOT
008431
ILLUMINATE

0032080 HF FAIL

000006977 APM ALWAYS FAULT INFLIGHT


HIGHLIGHT ATR 7
RECOMMENDATION

CHECK MSG ON MCDU AND OPT


TEST OF STICK PUSHER

REPLACE CARGO DOOR ACTUATOR


CHK MSG ON ADU,OPT TEST AHRS
AS PER TSM 34-25-00 FIG 106 ,RPLC
COMP 1CA

REPLACE FIRE DETECTOR


34 WD
REPLACE AHRU #2

REPLACE ENGINE
CHECK PN FUEL PUMP ENG#2,
CHECK EEC CONNECTORE CARE
( IF NOT CONNECTORE CARE YET
PERFORM IT), TRIM EEC AND
PERFORM PAC (PLEASE SHARE THE
RESULT). SUSPECT PART EEC AND
FUEL PUMP ON REQUEST BY MCC

DMI INVESTIGA
RECOMMENDATION
REPLACE 5CT PROX SWITCH,
POWER CHECK,WIRING CHECK

REPLACE HF TRANSCEIVER DUE TO


LAST REPLACEMENT OF PART
STATUS "OVERHAULED"

OPT TEST APM, CHECK AFDAU FAIL,


CHECK ADC #1 AND ADC #2
REMARK
CONTINUE TS / INPROGRESS
A/C DOCK IN AT HM BTH
AOG
OPEN
CLOSED/REOPEN
ATR 72-500/600
MAINTENANCE ACTION

NO FEED BACK

NEED ACTUATOR P/N: 4170006310


PLEASE ARRANGE PART TO A/C RON STATION
PERFORM REPLACE AFCS COMPUTER, GROUND
MAINTENANCE TEST OF AUTOPILOT GOOD

NEED SENSING ELEMENT P/N : 51216-052


PLEASE ARRANGE PART TO A/C RON STATION
NEED AHRU P/N: 7003360-946
PLEASE ARRANGE PART TO A/C RON STATION

PERFORM REPLACEMENT OF ENG #1 AND


POWWER ASSURANCE CHECK FOUND
GOOD. A/C DECLARE SERVICEABLE
PERFORM PAC FOUND TQ ENG 2 85.9 % ONLY AT TO NOTCH,
WAITING SPARE EEC

VESTIGATE
MAINTENANCE ACTION
PERFORM POWER CHECK AT CONNECTOR PLUG 103VC PIN A
TO GROUND FOUND 28VDC
CONTINUITY CHECK AT ELECT PLUG 103VC PIN A WITH PIN B
AT ELECT PLUG 5CTA FOUND NOT CONNECT
AFTER CHECK FOUND CABLE CUTOFF, RECTIFICATION C/O.
OPERATIONAL TEST OF SPOILER INDICATION GOOD, DMI
CLOSED

EIC FOCUS TO ANNOTHER PROBLEM

PERFORM OPERATIONAL TEST OF APM FOUND GOOD, WAITING


CONFIRMATION OF RH AND LH TAT DURING FLIGHT
600
WO
STATUS
CLOSED

OPEN

OPEN
CLOSED 10/10/2019

OPEN
OPEN

SERVICEABLE 10/10/2019
OPEN

STATUS
CLOSED 10/10/2019

OPEN

MONITOR
REMARK STA RON

SUB
MONITOR BY CREW RESULT NORMAL CHECK
MSG ON ADU RESULT NFF,CONTINUE
MONITOR NEXT FLIGHT
FLIGHT FAULT SUMMARY :
- SVO SWNG MON (A)
- SVO SWNG MON (B) SUB
OPT TEST OF AHRS FOUND GOOD.
FGC TEST FOUND PASS.
PLEASE ARRANGE SPARE AP COMPUTER 1CA
PN : 7003947-606
FOR TROUBLE SHOOT.

UPG
UPG

AFTER CHECK DIMENSION OF DEFECT FOUND


OUT OF LIMIT, WAITING MRB FOR NEXT PLAN
BSI REPORT OUT OF LIMIT AREA COMBUSTION
CHAMBER LP IMPELLER. BDJ
RECOVERY PLAN REPLACE ENG
AT BDJ
BDO

REMARK STA RON


AFTER REPLACE PROXIMITY 5CT PROBLEM
STILL EXIST.BACK TO ORIGINAL.
WIRING CHECK 28 VDC AT PLUG PROXIMITY
5CT PIN A TO C FOUND 28VDC, PIN B TO C
INTERMITEN
1. PERFORM REPLACE PROX SWITCH 5CT
PROBLEM STILL EXIST.SPARE BACK TO
ORIGINAL
2. CHK PWR BETWEEN PIN A TO GROUND
FOUND 27 VDC.
3. X-CHANGE DIODE 35VD WITH 25VD PKU
PROBLEM STILL EXIST ON LH SPOILER.BACK
TO ORIGINAL.
4. PERFORM CHK PWR PIN B TO GROUND HAS
24DC ON CONNECTOR 5CT
REFF ASM 27-65-00 SCH 01 P 101 FIG 1
5. PERFORM CHECK DIODE ON 35VD PIN 30
AND 15 RESULT CONDITION DIODE GOOD.
6. PERFORM CHECK DIODE ON 10VU
CONNECTOR 5VC PIN 30 AND 53 RESULT
CONDITION DIODE GOOD.
7. PERFORM X-CHANGE PANEL MODULE FOR
MSG FOUND OPEN
POSSIBILITY 1RE2 ,CIRCUIT
REPOSTON AND CLEAN
CORY ANDOPT
TEST HF FOUND
ASSOCIATED GOOD
WIRING ONCONTIUNUE MONITOR
PANEL MODULE.OPT
INFO
TEST FROM EIC KRISNA
PROBLEM HF HAS BEEN GOOD
STILL EXIST.
AFTER
PLEASEREPOSITION 1RE. MONITOR
CONTINUE NEXT TROUBLE STILL
SHOOT UPG
EXIST
FOR REMAKSURE, DO POWER CHECK AT PIN A
PERFORM
CONNECTOR XCHANGE FIBER
PLUG 5CTA OPTIC
FOUND HF
28VDC
COUPLER
8. PERFORMAND TRANCEIVER
CONTINUITY WWITH
CHECK PINSPARE
C AT
ELECT CONNECTOR 5CTA TO GROUND FOUND
CONNECT
9. PERFORM CONTINUITY CHECK PIN B AT PKU
ELECT CONNECTOR 5CTA TO PIN 15 AT DIODE
35VD FOUND NOT CONNECT
WO
NO REG ATA WO NO
ISSUED

1 PK-WGY 27 959898 2/10/2019

2 PK-WJI 52-31 962863 9/10/2019

3 PK-WGH 26-12 963613 10/10/2019

4 PK-WFQ 34-25 963694 10/10/2019

5 PK-WGG 29 964119 11/10/2019

6 PK-WHK 21 964225 11/10/2019


960939 4/10/2019

7 PK-WFG 34-25

964289

8 PK-WFM 72 10/10/2019
DMI OPEN TS TAB
NO REG ATA
DATE/CAT ISSUED

4/10/2019
1 PK-WGG 23-11-1
"D"
6/10/2019

9/10/2019
2 PK-WFK 31-31
"C"
10/10/2019
HIGHLIG
ALERT NO DISCREPANCIES

SP TRICK STICK PUSHER FAULT INFLIGHT

CARGO DOOR UNABLE


104427
ELECTRICAL OPEN

LOOP A ENGINE #1 FAULT


SP TRICK
INTERMITTENT

EFIS COMP SOMETIMES


SP TRICK
ILLUMINATE

WHEN LANDING ROLLING


ALERT
SOMETIMES BRAKE LOSS FOR A
104544
SECOND THEN BRAKE NORMAL

ALERT CABIN DUCT TEMP ABOVE 50


104536 DEG
AHRS DATA INVALID DURING
104232
TAKE OFF MONITOR DO

ENG #2 CAN'T ACHIEVE TK OFF


POWER (ONLY ACHIEVE 81%) AT
BDO
D
DMI NO DISCREPANCIES

0032080 HF FAIL

000006977 APM ALWAYS FAULT INFLIGHT


HIGHLIGHT ATR 72
CHECK MSG ON MCDU AND OPT
TEST OF STICK PUSHER

REPLACE CARGO DOOR


ACTUATOR

REPLACE SENSINGELEMENT
34 WD

REPLACE AHRU #2

BLEEDING LOW PRESS

LEAK CHK,RPLC SERVICE


PRESSURE REGULATOR
( 6142HQ )
P/N.3214102-4
CHK MSG ON ADU,OPT TEST
AHRS AS PER TSM 34-25-00 FIG
106 ,RPLC COMP 1CA

X-CHANGE AFCS COMPUTER


1CA

CHECK PN FUEL PUMP ENG#2,


CHECK EEC CONNECTORE CARE
( IF NOT CONNECTORE CARE
YET PERFORM IT), TRIM EEC
AND PERFORM PAC (PLEASE
SHARE THE RESULT). SUSPECT
PART EEC AND FUEL PUMP ON
REQUEST BY MCC
DMI INVESTIGAT
RECOMMENDATION

REPLACE HF TRANSCEIVER DUE


TO LAST REPLACEMENT OF
PART STATUS "OVERHAULED"

OPT TEST APM, CHECK AFDAU


FAIL, CHECK ADC #1 AND ADC #2

REMARK
CONTINUE TS / INPROGRESS
A/C DOCK IN AT HM BTH
AOG
OPEN
CLOSED/REOPEN
ATR 72-500/600
MAINTENANCE ACTION

PERFORN OPT TEST FOUND NORMAL.CHECK


MSG FOUND NO MSG.
W/O CLOSED

SPARE ACTUATOR NOT AVAIL AT BDO

SPARE SENSING ELEMENT NOT AVAIL AT UPG

SPARE AHRU NOT AVAIL AT LOP

TOOL HAND PUMP NOT AVAIL AT BDJ

SPARE SPR NOT AVAIL SRG


AFTER MONITOR FOUND AP DISCONNECT
AND AHRS DATA INVALID STILL EXIST.
(FYI : STATUS SPARE AFCS COMP REPAIR)

CAN'T PERFORMED DUE O A/C RON JOG

PERFORM REPLACE EEC ENG #2 BUT CAN'T


CONTINUE ERU D/T NOT APPROVE FROM
AUTHORITY BDO
NVESTIGATE
MAINTENANCE ACTION

OPT TEST HF SYTEM RESULT NORMAL,


AND SPARE HF TX NOT AVAIL AT BDJ

OPT TEST APM ON GROUND RESULT


GOOD,CHECK MSG ON MCDU RESULT NFF
0/600
WO
STATUS
CLOSED

W/O 11/10/2019
CLOSED

OPEN

OPEN

OPEN

OPEN

OPEN
CLOSED 10/10/2019

OPEN

OPEN
STATUS

OPEN

MONITOR
REMARK STA RON

SOQ

NEED ACTUATOR
P/N: 4170006310 BDO
PLEASE ARRANGE PART TO A/C STA RON

NEED SENSING ELEMENT


P/N : 51216-052 UPG
PLEASE ARRANGE PART TO A/C STA RON

NEED AHRU
P/N: 7003360-946 LOP
PLEASE ARRANGE PART TO A/C STA RON

BDJ

NEED SERVICE PRESSURE REGULATOR.


PN :3214102-4 SRG
PLEASE ARRANGE PART TO A/C STA RON
MONITOR BY CREW RESULT NORMAL CHECK
MSG ON ADU RESULT NFF,CONTINUE
MONITOR NEXT FLIGHT
FLIGHT FAULT SUMMARY :
- SVO SWNG MON (A)
- SVO SWNG MON (B)
OPT TEST OF AHRS FOUND GOOD.
FGC TEST FOUND PASS.
PLEASE ARRANGE SPARE AP COMPUTER 1CA
PN : 7003947-606 JOG
FOR TROUBLE SHOOT.
PERFORM REPLACE AFCS COMP.GROUND
MAINTENANCE TEST OF AUTO PILOT GOOD

PERFORM PAC FOUND TQ ENG 2 85.9 % ONLY


BDO
AT TO NOTCH, WAITING SPARE EEC
REMARK STA RON

MSG FOUND 1RE2 , REPOST AND CLEAN OPT


TEST HF FOUND GOOD CONTIUNUE MONITOR
INFO FROM EIC KRISNA HF HAS BEEN GOOD
AFTER REPOSITION 1RE. MONITOR STILL BDJ
EXIST
PERFORM XCHANGE FIBER OPTIC HF
COUPLER AND TRANCEIVER WITH SPARE

PERFORM OPT TEST OF APM FOUND GOOD,


WAITING CONFIRMATION OF RH AND LH TAT PKU
DURING FLIGHT
WO
NO REG ATA WO NO
ISSUED

960939 4/10/2019

1 PK-WFG 34-25

964289

2 PK-WJI 52-31 962863 9/10/2019


3 PK-WGH 26-12 963613 10/10/2019

4 PK-WFQ 34-25 963694 10/10/2019

5 PK-WHK 21 964225 11/10/2019

6 PK-WGG 29 964119 11/10/2019

7 PK-WGZ 34-55 964531 12/10/2019


8 PK-WFM 72 10/10/2019

DMI OPEN TS TAB


NO REG ATA
DATE/CAT ISSUED

4/10/2019
1 PK-WGG 23-11-1
"D"
6/10/2019
11/10/2019
2 PK-WFL 33-48-1
"C"
12/10/2019

11/10/2019
3 PK-WFP 21-63-1
"C"
12/10/2019

11/10/2019
4 PK-WGJ 34-58-1
"C"
12/10/2019

9/10/2019
5 PK-WFK 31-31
"C"
10/10/2019
HIGHLIG
ALERT NO DISCREPANCIES

AHRS DATA INVALID DURING


104232
TAKE OFF MONITOR DO

CARGO DOOR UNABLE


104427
ELECTRICAL OPEN
LOOP A ENGINE #1 FAULT
SP TRICK
INTERMITTENT

EFIS COMP SOMETIMES


SP TRICK
ILLUMINATE

CABIN DUCT TEMP ABOVE 50


104536
DEG

WHEN LANDING ROLLING


104544 SOMETIMES BRAKE LOSS FOR A
SECOND THEN BRAKE NORMAL

VOR/DME #1 & #2 CAPT SIDE NOT


104598
WORKING
ENG #2 CAN'T ACHIEVE TK OFF
POWER (ONLY ACHIEVE 81%) AT
BDO

D
DMI NO DISCREPANCIES

0032080 HF FAIL
0000604 LOWER BEACON LT U/S

COMP TEMP INDICATOR NOT OK


0024708
(U/S)

00018696 GPS FAULT INFLIGHT

000006977 APM ALWAYS FAULT INFLIGHT


HIGHLIGHT ATR 72

CHK MSG ON ADU,OPT TEST


AHRS AS PER TSM 34-25-00 FIG
106 ,RPLC COMP 1CA

X-CHANGE AFCS COMPUTER


1CA

REPLACE CARGO DOOR


ACTUATOR
P/N :4170006310
RPLC SENSING ELEMENT
34WD
P/N : 51216-052

RPLC AHRU #2
P/N : 7003360-946

LEAK CHK,RPLC SERVICE


PRESSURE REGULATOR
( 6142HQ )
P/N : 214102-4

BLEEDING LOW PRESS

OPT VOR AND DME, CHECK MSG


FROM MCDU , REPLACED VOR
RECIVER
CHECK PN FUEL PUMP ENG#2,
CHECK EEC CONNECTORE CARE
( IF NOT CONNECTORE CARE
YET PERFORM IT), TRIM EEC
AND PERFORM PAC (PLEASE
SHARE THE RESULT). SUSPECT
PART EEC AND FUEL PUMP ON
REQUEST BY MCC

DMI INVESTIGAT
RECOMMENDATION

RPLC HF TRANSCEIVER DUE TO


LAST REPLACEMENT OF PART
STATUS "OVERHAULED"
RPLC BOTTOM ANTI COLL
LIGHT,RPLC BOTTOM ANTI COLL
POWER SUPPLY

OPT TEST COMP DUAL TEMP IND


( 2HK ) , RPLC COMP TEMP IND ,
RPLC SWITCH TOGGLE (3HK )

CHK MSG ,RPLC RECEIVER,


RPLC ANTENNA

OPT TEST APM, CHK AFDAU FAIL,


CHK ADC #1 AND ADC #2

REMARK
CONTINUE TS / INPROGRESS
A/C DOCK IN AT HM BTH
AOG
OPEN
CLOSED/REOPEN
ATR 72-500/600
MAINTENANCE ACTION

AFTER MONITOR FOUND AP DISCONNECT AND


AHRS DATA INVALID STILL EXIST.
(FYI : STATUS SPARE AFCS COMP REPAIR)

SPARE AFCS COMP NOT AVAIL AT SUB

SPARE CARGO DOOR ACTUATOR NOT AVAIL AT


BDO
PERFORMED REPLACE SENSING ELEMENT 34WD OPT
TEST RESULT NORMAL W/O CLOSED

SPARE AHRU NOT AVAIL AT KOE

CABIN DUCT TEMPT RAISE ONLY TAKE OFF,PLEASE


ARRANGE SPARE SPR

MONITOR TODAY BRAKE NORMAL

PERFORMED X CHANGE VOR TRANSCEIVER 1 TO 2


OPT TEST RESULT NORMAL,PLEASE MONITOR
PERFORM REPLACE EEC ENG #2 C/O.
ENGINE GROUND RUN TAKE OFF POWER FOUND ENG #2
TQ 99.7%

VESTIGATE
MAINTENANCE ACTION

P'SE ARRANGE SPARE HF TX


NO INFO FROM EIC

PERFORMED X CHANGE DUAL TEMPT INCATOR RESULT


PROBLEM STILL EXIST,SUSPECT ROM TOGLE SWITCH
3HK,PLEASE ARRANGE SPARE 3HK FOR T/S

PEFORMED CHECK MSG SHOW 2SN1 (GPS


ANTENNA).PLEASE ARRANGE SPARE ATNENNA
GPS FOR T/S
CAN'T CONTINUE TS DUE TO GPU NOT AVAIL AT
WNI

AFTER MONITOR INFLIGHT TAT WITH :


ADC #1 = 15*C
ADC #2 = 21*C
PLEASE ARRANGE SPARE R/H TAT PROBE
0/600
WO
STATUS
CLOSED

CLOSED 10/10/2019

OPEN

OPEN
MONITOR

OPEN

OPEN

MONITOR

MONITOR
CLOSED 12/10/2019

STATUS

OPEN
OPEN

OPEN

OPEN

MONITOR
REMARK STA RON

MONITOR BY CREW RESULT NORMAL CHECK


MSG ON ADU RESULT NFF,CONTINUE
MONITOR NEXT FLIGHT
FLIGHT FAULT SUMMARY :
- SVO SWNG MON (A)
- SVO SWNG MON (B)
OPT TEST OF AHRS FOUND GOOD.
FGC TEST FOUND PASS.
PLEASE ARRANGE SPARE AP COMPUTER 1CA
PN : 7003947-606 SUB
FOR TROUBLE SHOOT.
PERFORM REPLACE AFCS COMP.GROUND
MAINTENANCE TEST OF AUTO PILOT GOOD

NEED ACTUATOR
P/N: 4170006310 BDO
PLEASE ARRANGE PART TO A/C STA RON
NEED SENSING ELEMENT
P/N : 51216-052 UPG
PLEASE ARRANGE PART TO A/C STA RON

NEED AHRU
P/N: 7003360-946 KOE
PLEASE ARRANGE PART TO A/C STA RON

NEED SERVICE PRESSURE REGULATOR.


P/N :3214102-4 SRG
PLEASE ARRANGE PART TO A/C STA RON

UPG

BUW
PERFORM PAC FOUND TQ ENG 2 85.9 % ONLY
AT TO NOTCH, WAITING SPARE EEC BDO

REMARK STA RON

MSG FOUND 1RE2 , REPOST AND CLEAN OPT


TEST HF FOUND GOOD CONTIUNUE MONITOR
INFO FROM EIC KRISNA HF HAS BEEN GOOD
AFTER REPOSITION 1RE. MONITOR STILL
EXIST
PERFORM XCHANGE FIBER OPTIC HF UPG
COUPLER AND TRANCEIVER WITH SPARE
OPT TEST HF SYSTEM RESULT NORMAL.
PLEASE ARRANGE SPARE HF TRANSCEIVER
TO A/C STA RON
BDJ

WNI

PERFORM OPT TEST OF APM FOUND GOOD,


WAITING CONFIRMATION OF RH AND LH TAT
DURING FLIGHT

11/10/2019
OPT TEST APM ON GROUND RESULT
GOOD.CHECK MSG ON MCDU RESULT NFF
WO
NO REG ATA WO NO
ISSUED

960939 4/10/2019

1 PK-WFG 34-25

964289

2 PK-WJI 52-31 962863 9/10/2019


3 PK-WGH 26-12 963613 10/10/2019

4 PK-WFQ 34-25 963694 10/10/2019

5 PK-WHK 21 964225 11/10/2019

6 PK-WGG 29 964119 11/10/2019

7 PK-WGZ 34-55 964531 12/10/2019

8 PK-WFY 34 13/10/2019
9 PK-WJF 56 13/10/2019

10 PK-WHO 72 13/10/2019

DMI OPEN TS TAB


NO REG ATA
DATE/CAT ISSUED

4/10/2019
1 PK-WGG 23-11-1
"D"
6/10/2019
11/10/2019
2 PK-WFL 33-48-1
"C"
12/10/2019

11/10/2019
3 PK-WFP 21-63-1
"C"
12/10/2019

11/10/2019
4 PK-WGJ 34-58-1
"C"
12/10/2019

9/10/2019
5 PK-WFK 31-31
"C"
10/10/2019
11/10/2019
6 PK-WFO 32-61-1
"B"
13/10/2019

12/10/2019
7 PK-WFQ 22-18-1
"B"
13/10/2019

10/10/2019
8 PK-WFL 23-51-1
"C"
13/10/2019
HIGHLIG
ALERT NO DISCREPANCIES

AHRS DATA INVALID DURING


104232
TAKE OFF MONITOR DO

CARGO DOOR UNABLE


104427
ELECTRICAL OPEN
LOOP A ENGINE #1 FAULT
SP TRICK
INTERMITTENT

EFIS COMP SOMETIMES


SP TRICK
ILLUMINATE

CABIN DUCT TEMP ABOVE 50


104536 DEG (DUCT RISE AFTER TAKE
OFF)

WHEN LANDING ROLLING


104544 SOMETIMES BRAKE LOSS FOR A
SECOND THEN BRAKE NORMAL

VOR/DME #1 & #2 CAPT SIDE NOT


104598
WORKING

STBY ALTIMETER DIFF 90FT ON


GROUND AND 240FT
INFLIGHTWITH CAPT AND FO
ALTIMETER
LH WINDSHIELD CRACK

HOT START ENG #2 AND #1 ITT


RAPIDLY INCREASE AND MAIN
AND EMER BATTERY DROP

D
DMI NO DISCREPANCIES

0032080 HF FAIL
0000604 LOWER BEACON LT U/S

COMP TEMP INDICATOR NOT OK


0024708
(U/S)

00018696 GPS FAULT INFLIGHT

000006977 APM ALWAYS FAULT INFLIGHT


LH LANDING GEAR UNLOCK LT
0025822
ILLUMINATE BEFORE LANDING

013315 AUTO PILOT US

HEADSET CAPT SIDE CAN'T


000000603
TRANSMIT USING PTT
HIGHLIGHT ATR 72

CHK MSG ON ADU,OPT TEST


AHRS AS PER TSM 34-25-00 FIG
106 ,RPLC COMP 1CA

X-CHANGE AFCS COMPUTER


1CA

REPLACE CARGO DOOR


ACTUATOR
P/N :4170006310
RPLC SENSING ELEMENT
34WD
P/N : 51216-052

RPLC AHRU #2
P/N : 7003360-946

LEAK CHK,RPLC SERVICE


PRESSURE REGULATOR
( 6142HQ )
P/N : 3214102-4

BLEEDING LOW PRESS

OPT VOR AND DME, CHECK MSG


FROM MCDU , REPLACED VOR
RECIVER

BLOW LINE, REPLACE STBY ALT


INDICATOR, OPERATIONAL TEST
USING ADC TESTER
REPLACE WINDSHIELD

REPLACE MAIN AND EMER


BATTERY

DMI INVESTIGAT
RECOMMENDATION

RPLC HF TRANSCEIVER DUE TO


LAST REPLACEMENT OF PART
STATUS "OVERHAULED"
RPLC BOTTOM ANTI COLL
LIGHT,RPLC BOTTOM ANTI COLL
POWER SUPPLY

OPT TEST COMP DUAL TEMP IND


( 2HK ) , RPLC COMP TEMP IND ,
RPLC SWITCH TOGGLE (3HK )

CHK MSG ,RPLC RECEIVER,


RPLC ANTENNA

OPT TEST APM, CHK AFDAU FAIL,


CHK ADC #1 AND ADC #2
CHECK RESISTOR MODULE
920VR,921VR CLIP ASSY-
RETAINING (920VR1, 921VR1)
AND CONNECTOR-RECEPTACLE
(920VRA, 921VRA) FOR
CONDITION

CHECK FLIGHT FAULT SUMMARY


AND CONTINUE
TROUBLESHOOTING AS PER
FLIGHT FAULT SUMMARY CODE

OPERATIONAL TEST OF AUDIO


INTEGRATING

REMARK
CONTINUE TS / INPROGRESS
A/C DOCK IN AT HM BTH
AOG
OPEN
CLOSED/REOPEN
ATR 72-500/600
MAINTENANCE ACTION

AFTER MONITOR FOUND AP DISCONNECT AND


AHRS DATA INVALID STILL EXIST.
(FYI : STATUS SPARE AFCS COMP REPAIR)

X-CHANGE AFCS COMP WITH PK-WFO PLEASE


MONITOR

PLEASE ARRANGE PART TO A/C STA RON


AFTER MONITOR ONE DAYS FOUND GOOD

PLEASE ARRANGE PART TO A/C STA RON

NO INFO FROM EIC

EIC FOCUS ANOTHER PROBLEM

INFO FROM EIC VOR AND DME NORMAL

WAITING SPARE STBY ALTIMETER, ADC TESTER


AND IERA MAN POWER
WAITING SPARE AND MAN POWER

WAITING SPARE

VESTIGATE
MAINTENANCE ACTION

EIC FOCUS ANOTHER PROBLEM


REOPEN DMI D/T NEED POWER SUPPLY

EIC FOCUS ANOTHER PROBLEM

PLEASE ARRANGE SPARE ANTENA GPS

PLEASE ARRANGE SPARE R/H TAT PROBE


MSG 7GA PLEASE ARRANGE SPARE TO A/C RON

INFO FROM EIC AP NORMAL

NO INFO FROM EIC


0/600
WO
STATUS
CLOSED

CLOSED 10/10/2019

W/O 13/10/2019
CLOSED

OPEN
CLOSED 13/10/2019

OPEN

OPEN

MONITOR

MONITOR

AOG
AOG

FACING AOG

STATUS

OPEN
REOPEN 12/10/2019

OPEN

OPEN

MONITOR
OPEN

MONITOR

OPEN
REMARK STA RON

MONITOR BY CREW RESULT NORMAL CHECK


MSG ON ADU RESULT NFF,CONTINUE
MONITOR NEXT FLIGHT
FLIGHT FAULT SUMMARY :
- SVO SWNG MON (A)
- SVO SWNG MON (B)
OPT TEST OF AHRS FOUND GOOD.
FGC TEST FOUND PASS.
PLEASE ARRANGE SPARE AP COMPUTER 1CA
PN : 7003947-606 SUB
FOR TROUBLE SHOOT.
PERFORM REPLACE AFCS COMP.GROUND
MAINTENANCE TEST OF AUTO PILOT GOOD

NEED ACTUATOR
P/N: 4170006310 SOC
PLEASE ARRANGE PART TO A/C STA RON
NEED SENSING ELEMENT
P/N : 51216-052 BUW
PLEASE ARRANGE PART TO A/C STA RON

NEED AHRU
P/N: 7003360-946 KOE
PLEASE ARRANGE PART TO A/C STA RON

NEED SERVICE PRESSURE REGULATOR.


P/N :3214102-4
PLEASE ARRANGE PART TO A/C STA RON

BDJ

PERFORMED X CHANGE VOR


TRANSCEIVER 1 TO 2 OPT TEST RESULT BPN
NORMAL,PLEASE MONITOR

LOP
MDC

MOF

REMARK STA RON

MSG FOUND 1RE2 , REPOST AND CLEAN OPT


TEST HF FOUND GOOD CONTIUNUE MONITOR
INFO FROM EIC KRISNA HF HAS BEEN GOOD
AFTER REPOSITION 1RE. MONITOR STILL
EXIST
PERFORM XCHANGE FIBER OPTIC HF BDJ
COUPLER AND TRANCEIVER WITH SPARE
OPT TEST HF SYSTEM RESULT NORMAL.
PLEASE ARRANGE SPARE HF TRANSCEIVER
TO A/C STA RON
PERFORMED X CHANGE DUAL TEMPT
INCATOR RESULT PROBLEM STILL
EXIST,SUSPECT ROM TOGLE SWITCH BDJ
3HK,PLEASE ARRANGE SPARE 3HK FOR T/S

PEFORMED CHECK MSG SHOW 2SN1


(GPS ANTENNA).PLEASE ARRANGE
SPARE ATNENNA GPS FOR T/S UPG
CAN'T CONTINUE TS DUE TO GPU NOT
AVAIL AT WNI

PERFORM OPT TEST OF APM FOUND GOOD,


WAITING CONFIRMATION OF RH AND LH TAT
DURING FLIGHT

11/10/2019
OPT TEST APM ON GROUND RESULT
PKU
GOOD.CHECK MSG ON MCDU RESULT NFF
AFTER MONITOR INFLIGHT TAT WITH :
ADC #1 = 15*C
ADC #2 = 21*C
PLEASE ARRANGE SPARE R/H TAT PROBE
SUB

KOE
WO
NO REG ATA WO NO
ISSUED

1 PK-WJI 52-31 962863 9/10/2019

2 PK-WFQ 34-25 963694 10/10/2019

3 PK-WHK 21 964225 11/10/2019

4 PK-WGZ 34-55 964531 12/10/2019


5 PK-WJF 56 13/10/2019

6 PK-WGG 29 964119 11/10/2019

7 PK-WFY 34 13/10/2019

8 PK-WHO 72 13/10/2019

DMI OPEN TS TAB


NO REG ATA
DATE/CAT ISSUED
4/10/2019
1 PK-WGG 23-11-1
"D"
6/10/2019

12/10/2019
2 PK-WFQ 22-18-1
"B"
13/10/2019

10/10/2019
3 PK-WFL 23-51-1
"C"
13/10/2019
11/10/2019
4 PK-WFO 21-50-1
"C"
14/10/2019

11/10/2019
5 PK-WFP 21-63-1
"C"
12/10/2019

11/10/2019
6 PK-WGJ 34-58-1
"C"
12/10/2019
9/10/2019
7 PK-WFK 31-31
"C"
10/10/2019

11/10/2019
8 PK-WFO 32-61-1
"B"
13/10/2019

14/10/2019
9 PK-WFL 34-48-2 (4)
"A"
14/10/2019

11/10/2019
10 PK-WGZ 21-31-4 (2)
"A"
14/10/2019
HIGHLIG
ALERT NO DISCREPANCIES

CARGO DOOR UNABLE


104427
ELECTRICAL OPEN

EFIS COMP SOMETIMES


SP TRICK
ILLUMINATE

CABIN DUCT TEMP ABOVE 50


104536 DEG (DUCT RISE AFTER TAKE
OFF)

VOR/DME #1 & #2 CAPT SIDE NOT


104598
WORKING
LH WINDSHIELD CRACK

WHEN LANDING ROLLING


104544 SOMETIMES BRAKE LOSS FOR A
SECOND THEN BRAKE NORMAL

STBY ALTIMETER DIFF 90FT ON


GROUND AND 240FT
INFLIGHTWITH CAPT AND FO
ALTIMETER

HOT START ENG #2 AND #1 ITT


RAPIDLY INCREASE AND MAIN
AND EMER BATTERY DROP

D
DMI NO DISCREPANCIES
0032080 HF FAIL

013315 AUTO PILOT US

HEADSET CAPT SIDE CAN'T


000000603
TRANSMIT USING PTT
0025821 PASANGER CABIN HOT

COMP TEMP INDICATOR NOT OK


0024708
(U/S)

00018696 GPS FAULT INFLIGHT


000006977 APM ALWAYS FAULT INFLIGHT

LH LANDING GEAR UNLOCK LT


0025822
ILLUMINATE BEFORE LANDING

00000607 TERRAIN FAULT LT ILLUMINATE

CABIN RATE, LATE TO CATCHUP


0004339
TARGET CABIN ALTITUDE
HIGHLIGHT ATR 72
REPLACE CARGO DOOR
ACTUATOR
P/N :4170006310

RPLC AHRU #2
P/N : 7003360-946

LEAK CHK,RPLC SERVICE


PRESSURE REGULATOR
( 6142HQ )
P/N : 214102-4

OPT VOR AND DME, CHECK MSG


FROM MCDU , REPLACED VOR
RECIVER
REPLACE WINDSHIELD

BLEEDING LOW PRESS

BLOW LINE, REPLACE STBY ALT


INDICATOR, OPERATIONAL TEST
USING ADC TESTER

REPLACE MAIN AND EMER


BATTERY

DMI INVESTIGAT
RECOMMENDATION
RPLC HF TRANSCEIVER DUE TO
LAST REPLACEMENT OF PART
STATUS "OVERHAULED"

CHECK FLIGHT FAULT SUMMARY


AND CONTINUE
TROUBLESHOOTING AS PER
FLIGHT FAULT SUMMARY CODE

OPERATIONAL TEST OF AUDIO


INTEGRATING
COLLECT DATA DUCT TEMP AT
AUTO AND MANUAL MODE,
CONTINUE TROUBLESHOOTING
AS PER COLLECTED DATA

OPT TEST COMP DUAL TEMP IND


( 2HK ) , RPLC COMP TEMP IND ,
RPLC SWITCH TOGGLE (3HK )

CHK MSG ,RPLC RECEIVER,


RPLC ANTENNA
OPT TEST APM, CHK AFDAU FAIL,
CHK ADC #1 AND ADC #2

CHECK RESISTOR MODULE


920VR,921VR CLIP ASSY-
RETAINING (920VR1, 921VR1)
AND CONNECTOR-RECEPTACLE
(920VRA, 921VRA) FOR
CONDITION, REPLACE 7GA PROX
SWITCH

REFF TSM 34-48 TAWS


EXTENDED TEST,CONTINUE
TROUBLESHOOTING AS PER
MESSAGE

REPLACE DIGITAL CONTROLLER

REMARK
CONTINUE TS / INPROGRESS
A/C DOCK IN AT HM BTH
AOG
OPEN
CLOSED/REOPEN
ATR 72-500/600
MAINTENANCE ACTION

SPARE NOT AVAIL

SPARE NOT AVAIL

NOT APPROVED RUN ENGINE , SPARE SPR NOT


AVAIL

PERFORMED OPT OF VOR/DME , FOUND VOR #1


BLINKING ON CAPT SIDE AND DME 1 &2
SOMETIMES BLINKING ON CAPT & F/O SIDE

PLEASE ARRANG RECEIVER FOR T/S


PERFORM REPLACE LH WINDSHIELD, RESILENT
C/O, STILL WAITING FOR CURING SEAL AND PRESS
CHECK

PERFORMED BLEEDING LOW PRESS LINE

PERFORM BLOW LINE , REPLACE STBY ALTIMETER


INDICATOR, OPT AND LEAK CHECK BY ADC TESTER
FOUND GOOD. AIRCRAFT SERVICEABLE

PERFORM MAIN AND EMERGENCY BATTERY


REPLACEMENT, START ENG #1 AND #2 NORMAL,
AIRCRAFT SERVICEABLE

VESTIGATE
MAINTENANCE ACTION
PLEASE ARRANGE SPARE HF TRANSCEIVER

MSG : A/P INHIBIT


PERFORMED WIRING CHECK RESULT
PIN 4 AND PIN 5 ON CONNECTOR PLUG WAS
CUTTED
NEED MP IERA FOR RECTIFICATION

EIC FOCUS OTHER PROBLEM


COLLECT DATA BY ITT ENG #2

BLEED OFF PACK OFF : 398


BLEED ON PACK OFF : 411
BLEED ON PACK ON : 484
AUTO AND MAN MODE : WORKING
DUCT TEMP 15 DEG WITH RECIRC FAN OFF ( SET
ON FULL COLD )

WILL BE CONTINUE TS ON NEXT NIGHT A/C RON

PERFORMED REPLACEMENT TOGGLE SWITCH RESULT


GOOD, DMI CLOSED

REOPEN DMI WAITING SPARE GPS RECEIVER


REOPEN DMI WAITING SPARE R/H TAT

REOPEN DMI WAITING SPARE PROX SWT 7GA


( NEED A/C ON JACK FOR REPLACEMENT )

PERFORMED RERACT T2CAS COMP, RESULT GOOD


DMI CLOSED

REOPEN DMI WAITING SPARE DIGITAL


CONTROLLER
0/600
WO
STATUS
CLOSED

OPEN

OPEN

OPEN

OPEN
AOG

CLOSED 14/10/2019

SERVICEABLE 14/10/2019

SERVICEABLE 14/10/2019

STATUS
OPEN

OPEN

OPEN
OPEN

CLOSED 14/10/2019

REOPEN 14/10/2019
REOPEN 14/10/2019

REOPEN 14/10/2019

CLOSED 14/10/2019

REOPEN 14/10/2019
REMARK STA RON

NEED ACTUATOR
P/N: 4170006310 SOC
PLEASE ARRANGE PART TO A/C STA RON

NEED AHRU
P/N: 7003360-946 SRG
PLEASE ARRANGE PART TO A/C STA RON

NEED SERVICE PRESSURE REGULATOR.


P/N :3214102-4 KOE
PLEASE ARRANGE PART TO A/C STA RON

PERFORMED X CHANGE VOR


TRANSCEIVER 1 TO 2 OPT TEST RESULT UPG
NORMAL,PLEASE MONITOR
MDC

UPG

LOP

MOF

REMARK STA RON


MSG FOUND 1RE2 , REPOST AND CLEAN OPT
TEST HF FOUND GOOD CONTIUNUE MONITOR
INFO FROM EIC KRISNA HF HAS BEEN GOOD
AFTER REPOSITION 1RE. MONITOR STILL
EXIST UPG
PERFORM XCHANGE FIBER OPTIC HF
COUPLER AND TRANCEIVER WITH SPARE
OPT TEST HF SYSTEM RESULT NORMAL.

SRG

SUB
SUB

PERFORMED X CHANGE DUAL TEMPT


INCATOR RESULT PROBLEM STILL
EXIST,SUSPECT ROM TOGLE SWITCH BDJ
3HK,PLEASE ARRANGE SPARE 3HK FOR T/S

PEFORMED CHECK MSG SHOW 2SN1


(GPS ANTENNA).PLEASE ARRANGE
SPARE ATNENNA GPS FOR T/S UPG
CAN'T CONTINUE TS DUE TO GPU NOT
AVAIL AT WNI
PERFORM OPT TEST OF APM FOUND GOOD,
WAITING CONFIRMATION OF RH AND LH TAT
DURING FLIGHT

11/10/2019
OPT TEST APM ON GROUND RESULT
PKU
GOOD.CHECK MSG ON MCDU RESULT NFF
AFTER MONITOR INFLIGHT TAT WITH :
ADC #1 = 15*C
ADC #2 = 21*C
PLEASE ARRANGE SPARE R/H TAT PROBE

MSG 7GA PLEASE ARRANGE SPARE TO


A/C RON
SUB

SUB

UPG
NO REG ATA WO NO

1 PK-WJI 52-31 962863

2 PK-WFQ 34-25 963694

3 PK-WHK 21 964225

4 PK-WGZ 34-55 964531


5 PK-WHS 31 965890

6 PK-WGR 27

DMI OPEN
NO REG ATA
DATE/CAT
4/10/2019
1 PK-WGG 23-11-1
"D"

12/10/2019
2 PK-WFQ 22-18-1
"B"

10/10/2019
3 PK-WFL 23-51-1
"C"
11/10/2019
4 PK-WFO 21-50-1
"C"

14/10/2019
5 PK-WHY 31-21-1
"C"
H
WO
ALERT NO
ISSUED

9/10/2019 104427

10/10/2019 SP TRICK

11/10/2019 104536

12/10/2019 104598
15/10/2019

TS TAB
DMI NO
ISSUED
6/10/2019 0032080

13/10/2019 013315

13/10/2019 000000603
14/10/2019 0025821

15/10/2019 031513
HIGHLIGH
DISCREPANCIES

CARGO DOOR UNABLE ELECTRICAL


OPEN

EFIS COMP SOMETIMES ILLUMINATE

CABIN DUCT TEMP ABOVE 50 DEG (DUCT


RISE AFTER TAKE OFF)

VOR/DME #1 & #2 CAPT SIDE NOT


WORKING
KNOB 2 PWR MGT LOOSE

LEFT RUDDER PEDAL UNABLE FULL


MOVEMENT,AFTER CHECK ON VISUAL &
MCDU DEPLECTION OUT OF LIMIT

DMI
DISCREPANCIES
HF FAIL

AUTO PILOT US

HEADSET CAPT SIDE CAN'T TRANSMIT


USING PTT
PASANGER CABIN HOT

FO SIDE CLOCK U/S


IGHLIGHT ATR 72-5
REPLACE CARGO DOOR
ACTUATOR
P/N :4170006310

RPLC AHRU #2
P/N : 7003360-946

LEAK CHK,RPLC SERVICE


PRESSURE REGULATOR
( 6142HQ )
P/N : 214102-4

OPT VOR AND DME, CHECK MSG


FROM MCDU , REPLACED VOR
RECIVER
REPLACE KNOB NO 2

CHECK MECHANICAL RUDDER


PEDAL AT COCKPIT UNDER
FLOOR

DMI INVESTIGATE
RECOMMENDATION
RPLC HF TRANSCEIVER DUE TO
LAST REPLACEMENT OF PART
STATUS "OVERHAULED"

CHECK FLIGHT FAULT SUMMARY


AND CONTINUE
TROUBLESHOOTING AS PER
FLIGHT FAULT SUMMARY CODE

OPERATIONAL TEST OF AUDIO


INTEGRATING
COLLECT DATA DUCT TEMP AT
AUTO AND MANUAL MODE,
CONTINUE TROUBLESHOOTING
AS PER COLLECTED DATA

REPLACE FO CLOCK

REMARK
CONTINUE TS / INPROGRESS
A/C DOCK IN AT HM BTH
AOG
OPEN
CLOSED/REOPEN
TR 72-500/600
MAINTENANCE ACTION

NEED ACTUATOR
P/N: 4170006310
PLEASE ARRANGE PART TO A/C STA RON

NEED AHRU
P/N: 7003360-946
PLEASE ARRANGE PART TO A/C STA RON

NEED SERVICE PRESSURE REGULATOR.


P/N :3214102-4
PLEASE ARRANGE PART TO A/C STA RON

PLEASE ARRANG RECEIVER FOR T/S


SPARE KNOB PWR MGT AVAIL AT STA PNK , CAN'T
REPLACED D/T ELEN KEY SMALL INSTRUMENT NOT
AVAIL STA PNK AND EIC FOCUS T/S ANOTHER
PROBLEM

1. PERFORMED DVI CHECK ACTUAL PEDAL FOUND


GOOD
2. CHECK FROM ALPHA CALL UP YAWCP MAX LEFT
+007.7 OUT OF LIMIT . RANGE +12 +/- 2
3. PERFORMED RIGING RUDDER
AFTER RIGING CHECK VIA ALPHA CALL FOUND
YAWCP LEFT +11,2 RIGHT -11,4
4. PERFORMED OPRATIONAL TEST RCU FOUND
GOOD
5. PERFORMED OPRATIONAL TEST TLU FOUND
GOOD A/C SERVICEABLE

ESTIGATE
MAINTENANCE ACTION
AFTER XCHANGE FIBER OPTIC HF COUPLER AND
TRANCEIVER WITH SPARE
OPT TEST HF SYSTEM RESULT NORMAL. AND MONITOR 4
DAY FOUND GOOD DMI CLOSED

PERFORMED RECTIFICATION CABLE PIN 4AND PIN


5 ON TERMINAL 5024VC D/T BROKEN / CUT
OPRATIONAL TEST AUTO PILOT SYS ON GROUND
NORMAL . AND MONITOR 1 DAY FOUND GOOD DMI
CLOSED

PERFORMED CLEAND AND REPOST PTT SWITCH


CAPT SIDE OPRATION TEST FOUND GOOD DMI
CLOSED
CAN'T PERFORMED D/T OTORITY OPRATING HRS
AIRPORT BDO FOR RUNING ENGINE

PERFORMED X CHANGE CLOCK FO SIDE WITH


CAPT SIDE FOUND PROBLEM MOVE TO CAPT SIDE
BACK TO ORI . REOPEN DMI REQ PART CLOCK
600
WO
STATUS
CLOSED

OPEN

OPEN

OPEN

OPEN
OPEN

CLOSED 15/10/2019

STATUS
CLOSED 15/10/2019

CLOSED 15/10/2019

CLOSED 15/10/2019
OPEN

CLOSED 15/10/2019
REMARK STA RON

NEED ACTUATOR
P/N: 4170006310 PKY
PLEASE ARRANGE PART TO A/C STA RON

NEED AHRU
P/N: 7003360-946 SUB
PLEASE ARRANGE PART TO A/C STA RON

NEED SERVICE PRESSURE REGULATOR.


P/N :3214102-4 SWQ
PLEASE ARRANGE PART TO A/C STA RON

1. PERFORMED X CHANGE VOR


TRANSCEIVER 1 TO 2 OPT TEST RESULT
NORMAL,PLEASE MONITOR
2. PERFORMED OPT OF VOR/DME ,
FOUND VOR #1 BLINKING ON CAPT SIDE BUW
AND DME 1 &2 SOMETIMES BLINKING ON
CAPT & F/O SIDE

PLEASE ARRANG RECEIVER FOR T/S


PNK

KOE

REMARK STA RON


MSG FOUND 1RE2 , REPOST AND CLEAN OPT
TEST HF FOUND GOOD CONTIUNUE MONITOR
INFO FROM EIC KRISNA HF HAS BEEN GOOD
AFTER REPOSITION 1RE. MONITOR STILL
EXIST BDJ
PERFORM XCHANGE FIBER OPTIC HF
COUPLER AND TRANCEIVER WITH SPARE
OPT TEST HF SYSTEM RESULT NORMAL.

MSG : A/P INHIBIT


PERFORMED WIRING CHECK RESULT
PIN 4 AND PIN 5 ON CONNECTOR PLUG SUB
WAS CUTTED
NEED MP IERA FOR RECTIFICATION

JOG
COLLECT DATA BY ITT ENG #2

BLEED OFF PACK OFF : 398


BLEED ON PACK OFF : 411
BLEED ON PACK ON : 484
AUTO AND MAN MODE : WORKING
DUCT TEMP 15 DEG WITH RECIRC FAN
BDO
OFF ( SET ON FULL COLD )

WILL BE CONTINUE TS ON NEXT NIGHT


A/C RON

TTE
WO
NO REG ATA WO NO ALERT NO
ISSUED

1 PK-WJI 52-31 962863 9/10/2019 104427

2 PK-WFQ 34-25 963694 10/10/2019 SP TRICK

3 PK-WHK 21 964225 11/10/2019 104536


4 PK-WGZ 34-55 964531 12/10/2019 104598

5 PK-WFY 23 966201 16/10/2019

6 PK-WJK 34 966177 16/10/2019


7 PK-WHS 31 965890 15/10/2019

DMI OPEN TS TAB


NO REG ATA DMI NO
DATE/CAT ISSUED

11/10/2019
1 PK-WFO 21-50-1
"C"
14/10/2019 0025821
15/10/2019
2 PK-WJF 52-11-1
"B"
16/10/2019 0028265
HIGHLIGHT ATR 7
DISCREPANCIES

REPLACE CARGO DOOR


CARGO DOOR UNABLE ELECTRICAL ACTUATOR
OPEN
P/N :4170006310

RPLC AHRU #2
EFIS COMP SOMETIMES ILLUMINATE
P/N : 7003360-946

LEAK CHK,RPLC SERVICE


CABIN DUCT TEMP ABOVE 50 DEG (DUCT PRESSURE REGULATOR
RISE AFTER TAKE OFF) ( 6142HQ )
P/N : 214102-4
OPT VOR AND DME, CHECK MSG
VOR/DME #1 & #2 CAPT SIDE NOT
FROM MCDU , REPLACED VOR
WORKING
RECIVER

CHECK MESSAGE ON HF CTRL


HF UNABLE TO TRANSMIT
PANEL, FUNCT TEST

REPLACED RADAR TRANCEIVER


WX RADAR FAILED
7SQ
KNOB 2 PWR MGT LOOSE REPLACE KNOB NO 2

DMI INVESTIGA
DISCREPANCIES RECOMMENDATION

COLLECT DATA DUCT TEMP AT


AUTO AND MANUAL MODE,
PASANGER CABIN HOT
CONTINUE TROUBLESHOOTING
AS PER COLLECTED DATA
CABIN DOOR INDICATOR SYSTEM PAGE
AND OVERHEAD PANEL ILLUMINATE ALL WIRING CHECK
PHASE

REMARK
CONTINUE TS / INPROGRESS
A/C DOCK IN AT HM BTH
AOG
OPEN
CLOSED/REOPEN
ATR 72-500/600
MAINTENANCE ACTION STATUS

NEED ACTUATOR
P/N: 4170006310 OPEN
PLEASE ARRANGE PART TO A/C STA RON

NEED AHRU
P/N: 7003360-946 OPEN
PLEASE ARRANGE PART TO A/C STA RON

NEED SERVICE PRESSURE REGULATOR.


P/N :3214102-4 OPEN
PLEASE ARRANGE PART TO A/C STA RON
INFO FROM EIC BPN AFTER MONITOR 2 DAY
VOR/DME CAPT SIDE WORKING NORMAL P'SE MONITOR
CONTINU MONITOR

PERFORMED CHECK MESSAGE ON HF CTRL PANEL


FOUND NOT MSG . PERFORMED FUCTIONAL TEST
MONITOR
ON GROUND FOUND NORMAL WORKING . P'SE
MONITOR INFLIGHT

FTER CHECK FOUND MSG RAI 7SQ PLEASE


OPEN
ARRANGE PART TO A/C STA RON
PERFORMED REPLACED KNOB #2 PWRB MGT D/T
CLOSED
LOOSE . OPT FOUND GOOD W/O CLOSED

ESTIGATE
MAINTENANCE ACTION STATUS

CAN'T PERFORMED D/T OTORITY OPRATING HRS


OPEN
AIRPORT BDO FOR RUNING ENGINE
1. Cek continuity pin F microswitch 31WS to pin D
microswitch 7WS result good
2. Cek continuity pin F microswitch 7WS to pin D
microswitch 9Ws result good
3. Cek continuity pin F microswitch 9WS to pin D
microswitch 11WS Result good
4. Cek continuity pin Z relay 19WS to pin F microswitch
31WS result BAD OPEN
5. Cek pin Z relay 19WS to Ground result no grounding
6. Cek pin F microswitch 31WS to Ground result no
grounding
7. Cek 28vdc microswitch 31ws pin F result 0 volt
WO
REMARK STA RON
CLOSED

NEED ACTUATOR
P/N: 4170006310 PKY
PLEASE ARRANGE PART TO A/C STA RON

NEED AHRU
P/N: 7003360-946 BDO
PLEASE ARRANGE PART TO A/C STA RON

NEED SERVICE PRESSURE REGULATOR.


P/N :3214102-4 LOP
PLEASE ARRANGE PART TO A/C STA RON
1. PERFORMED X CHANGE VOR
TRANSCEIVER 1 TO 2 OPT TEST RESULT
NORMAL,PLEASE MONITOR
2. PERFORMED OPT OF VOR/DME ,
FOUND VOR #1 BLINKING ON CAPT SIDE BPN
AND DME 1 &2 SOMETIMES BLINKING ON
CAPT & F/O SIDE

PLEASE ARRANG RECEIVER FOR T/S

BDJ

UPG
SPARE KNOB PWR MGT AVAIL AT STA
PNK , CAN'T REPLACED D/T ELEN KEY
16/10/2019
SMALL INSTRUMENT NOT AVAIL STA PNK
PNK
AND EIC FOCUS T/S ANOTHER PROBLEM

REMARK STA RON


COLLECT DATA BY ITT ENG #2

BLEED OFF PACK OFF : 398


BLEED ON PACK OFF : 411
BLEED ON PACK ON : 484
AUTO AND MAN MODE : WORKING
DUCT TEMP 15 DEG WITH RECIRC FAN
BDO
OFF ( SET ON FULL COLD )

WILL BE CONTINUE TS ON NEXT NIGHT


A/C RON
MDC
NO REG ATA WO NO

1 PK-WJI 52-31 962863

2 PK-WFQ 34-25 963694

3 PK-WHK 21 964225
4 PK-WGZ 34-55 964531

5 PK-WFY 23 966201

6 PK-WJK 34 966177

7 PK-WGZ 21 966685
8 PK-WJK 22 966744

9 PK-WHM 22 966721

10 PK-WGZ 74 966780

11 PK-WGQ 72

DMI OPEN
NO REG ATA
DATE/CAT
11/10/2019
1 PK-WFO 21-50-1
"C"

15/10/2019
2 PK-WJF 52-11-1
"B"
16/10/2019
3 PK-WHT 61-51
''C''
HIGH
WO
ALERT NO
ISSUED

9/10/2019 104427

10/10/2019 SP TRICK

11/10/2019 104536
12/10/2019 104598

16/10/2019

16/10/2019

17/10/2019 SP TRICK
17/10/2019 SP TRICK

17/10/2019 SP TRICK

17/10/2019 104849

TS TAB
DMI NO
ISSUED
14/10/2019 0025821

16/10/2019 0028265
17/10/2019
HIGHLIGHT A
DISCREPANCIES

CARGO DOOR UNABLE ELECTRICAL


OPEN

EFIS COMP SOMETIMES ILLUMINATE

CABIN DUCT TEMP ABOVE 50 DEG (DUCT


RISE AFTER TAKE OFF)
VOR/DME #1 & #2 CAPT SIDE NOT
WORKING

HF UNABLE TO TRANSMIT

WX RADAR FAILED

AFTER T/O BLEED #2 DUCT TEMP


INCREASE TO 80-90 'C BOTH AUTO OR
MANUAL MODE
AUTO PILOT U/S

AP / YD DISCONNECT INFLT

IGNITER B ENG NO 1 NOT WORKING

ENG #1 FLAME OUT DURING DESCENT


THEN AUTO RELIGHT

DMI INV
DISCREPANCIES
PASANGER CABIN HOT

CABIN DOOR INDICATOR SYSTEM PAGE


AND OVERHEAD PANEL ILLUMINATE ALL
PHASE
UNABLE RELEASE PROPBRAKE ENG #2
HLIGHT ATR 72-500
RECOMMENDATION

REPLACE CARGO DOOR


ACTUATOR
P/N :4170006310

RPLC AHRU #2
P/N : 7003360-946

LEAK CHK,RPLC SERVICE


PRESSURE REGULATOR
( 6142HQ )
P/N : 3214102-4
OPT VOR AND DME, CHECK MSG
FROM MCDU , REPLACED VOR
RECIVER

CHECK MESSAGE ON HF CTRL


PANEL, FUNCT TEST

REPLACED RADAR TRANCEIVER


7SQ

REPLACE SERVICE PRESS


REGULATOR
OPT TEST OF AUTO PILOT

REPLACE AP YAW ACT ( 19 CA )

AURAL CHECK, VISUAL CHECK


IGNITER AND VISUAL CHECK
LEAD

WAITING FOR READING PCMCIA


CARD AND ATR OR PW
RECOMENDATION

DMI INVESTIGATE
RECOMMENDATION
COLLECT DATA DUCT TEMP AT
AUTO AND MANUAL MODE,
CONTINUE TROUBLESHOOTING
AS PER COLLECTED DATA, LEAK
CHECK, EXCHANGE TICV
COLLECT DATA BY INFARED
TOOL

WIRING CHECK
OPT TEST OF PROPBRAKE
CHCK MSG ON MCDU

REMARK
CONTINUE TS / INPROGRESS
A/C DOCK IN AT HM BTH
AOG
OPEN
CLOSED/REOPEN
TR 72-500/600
MAINTENANCE ACTION

NEED ACTUATOR
P/N: 4170006310
PLEASE ARRANGE PART TO A/C STA RON

NEED AHRU
P/N: 7003360-946
PLEASE ARRANGE PART TO A/C STA RON

NEED SERVICE PRESSURE REGULATOR.


P/N :3214102-4
PLEASE ARRANGE PART TO A/C STA RON
AFTER MONITOR 3 DAYS GOOD, OPT TEST ON GROUND
GOOD. WO CLOSED

OPT TEST ON GROUND FOUND NORMAL, PLEASE


CONTINUE MONITOR

AFTER CHECK FOUND MSG RAI 7SQ PLEASE ARRANGE


PART TO A/C STA RON

NEED SERVICE PRESSURE REGULATOR.


P/N :3214102-4
PLEASE ARRANGE PART TO A/C STA RON
CHECK AVS/LAST LEG REPORT NO MESSAGE,OPT TEST
ON GROUND FOUND NORMAL, PLEASE CONTINUE
MONITOR

MONITOR TODAY GOODS, READ ACMS/AVS/LAST LEG


REPORT NO MESSAGE RELATED TO AUTO PILOT

VISUAL CHECK OF IGNITER PLUG FOUND OUT OF LIMIT,


REPLACE IGNITER PLUG C/O, START ENG WITH IGN B
GOOD

CHECK EEC AND HMU CONNECTOR C/O, DO PAC C/O,


PLAN TO REPLACE EEC, WAITING SPARE EEC

ESTIGATE
MAINTENANCE ACTION
EIC FOCUS TO ANNOTHER PROBLEM

AFTER TROUBLESHOOTING, CHECK AT 31WS FOUND


BAD, REOPEN DMI DT WAITING SPARE MICROSWITCH
REMOVED PROP BRAKE D/T PROP BRAKE FAILURE AND
PERFORM DEACTIVATION OF PROP BRAKE, REOPEN DMI
DT WAITING SPARE PROP BRAKE
WO
STATUS
CLOSED

OPEN

OPEN

OPEN
CLOSED 16/10/2019

MONITOR

OPEN

MONITOR
MONITOR

MONITOR

CLOSED

AOG

STATUS
OPEN

REOPEN 17/10/2019
REOPEN 17/10/2019
REMARK STA RON

NEED ACTUATOR
P/N: 4170006310 PKY
PLEASE ARRANGE PART TO A/C STA RON

NEED AHRU
P/N: 7003360-946 BDO
PLEASE ARRANGE PART TO A/C STA RON

NEED SERVICE PRESSURE REGULATOR.


P/N :3214102-4 KOE
PLEASE ARRANGE PART TO A/C STA RON
1. PERFORMED X CHANGE VOR
TRANSCEIVER 1 TO 2 OPT TEST RESULT
NORMAL,PLEASE MONITOR
2. PERFORMED OPT OF VOR/DME , FOUND
BPN
VOR #1 BLINKING ON CAPT SIDE AND DME 1
&2 SOMETIMES BLINKING ON CAPT & F/O SIDE

PLEASE ARRANG RECEIVER FOR T/S

PERFORMED CHECK MESSAGE ON HF CTRL


PANEL FOUND NOT MSG . PERFORMED
UPG
FUCTIONAL TEST ON GROUND FOUND
NORMAL WORKING . P'SE MONITOR INFLIGHT

AFTER CHECK FOUND MSG RAI 7SQ PLEASE


BDJ
ARRANGE PART TO A/C STA RON

BPN
BDJ

PLM

BPN

EEC ON NO FAULT
EEC FAULT CODE NO FAOUND MESSAGE
KNO
TURN ALL BLADE FOUND NO NOISE

REMARK STA RON


COLLECT DATA BY ITT ENG #2

BLEED OFF PACK OFF : 398


BLEED ON PACK OFF : 411
BLEED ON PACK ON : 484
AUTO AND MAN MODE : WORKING
BDO
DUCT TEMP 15 DEG WITH RECIRC FAN OFF
( SET ON FULL COLD )

WILL BE CONTINUE TS ON NEXT NIGHT A/C


RON

1. Cek continuity pin F microswitch 31WS to pin D


microswitch 7WS result good
2. Cek continuity pin F microswitch 7WS to pin D
microswitch 9Ws result good
3. Cek continuity pin F microswitch 9WS to pin D
microswitch 11WS Result good
4. Cek continuity pin Z relay 19WS to pin F
microswitch 31WS result BAD
5. Cek pin Z relay 19WS to Ground result no MDC
grounding
6. Cek pin F microswitch 31WS to Ground result no
grounding
7. Cek 28vdc microswitch 31ws pin F result 0 volt
KOE
NO REG ATA WO NO

1 PK-WJI 52-31 962863

2 PK-WFQ 34-25 963694

3 PK-WHK 21 964225

4 PK-WFY 23 966201
5 PK-WJK 34 966177

6 PK-WGZ 21 966685

7 PK-WJK 22 966744

8 PK-WHM 22 966721

9 PK-WGQ 72
DMI OPEN
NO REG ATA
DATE/CAT

11/10/2019
1 PK-WFO 21-50-1
"C"

17/10/2019
2 PK-WFQ 24-22
"B"

17/10/2019
3 PK-WHG 30-11
"B"

16/10/2019
4 PK-WGR 22
"B"
17/10/2019
5 PK-WHR 30-11
"B"
HIGH
WO
ALERT NO
ISSUED

9/10/2019 104427

10/10/2019 SP TRICK

11/10/2019 104536

16/10/2019
16/10/2019

17/10/2019 SP TRICK

17/10/2019 SP TRICK

17/10/2019 SP TRICK
TS TAB
DMI NO
ISSUED

14/10/2019 0025821

18/10/2019 013316

18/10/2019 0032245

18/10/2019 007456
18/10/2019 0135760
HIGHLIGHT A
DISCREPANCIES

CARGO DOOR UNABLE ELECTRICAL


OPEN

EFIS COMP SOMETIMES ILLUMINATE

CABIN DUCT TEMP ABOVE 50 DEG (DUCT


RISE AFTER TAKE OFF)

HF UNABLE TO TRANSMIT
WX RADAR FAILED

AFTER T/O BLEED #2 DUCT TEMP


INCREASE TO 80-90 'C BOTH AUTO OR
MANUAL MODE

AUTO PILOT U/S

AP / YD DISCONNECT INFLT

ENG #1 FLAME OUT DURING DESCENT


THEN AUTO RELIGHT
DMI INV
DISCREPANCIES

PASANGER CABIN HOT

ACW BTC INLINE NOT ILLUMINATE

AIRFRAME DEICING FAULT

AFCS SOMETIMES NOT VALID IN APP


AIRFRAME DEICING FAULT
HLIGHT ATR 72-500
RECOMMENDATION

REPLACE CARGO DOOR


ACTUATOR
P/N :4170006310

RPLC AHRU #2
P/N : 7003360-946

LEAK CHK,RPLC SERVICE


PRESSURE REGULATOR
( 6142HQ )
P/N : 3214102-4

CHECK MESSAGE ON HF CTRL


PANEL, FUNCT TEST
REPLACED RADAR TRANCEIVER
7SQ

REPLACE SERVICE PRESS


REGULATOR

OPT TEST OF AUTO PILOT

REPLACE AP YAW ACT ( 19 CA )

WAITING FOR READING PCMCIA


CARD AND ATR OR PW
RECOMENDATION
REPLACE IGNITER PLUG A & B
ENG #1
REPLACE FUEL FILTER
REPLACE EEC
TQ#1 APPLY CONNECTOR CARE
DMI INVESTIGATE
RECOMMENDATION

COLLECT DATA DUCT TEMP AT


AUTO AND MANUAL MODE,
CONTINUE TROUBLESHOOTING
AS PER COLLECTED DATA, LEAK
CHECK, EXCHANGE TICV
COLLECT DATA BY INFARED
TOOL

ANN TEST AND REPLACE


CONTACTOR 7XU AND 8 XU
CHECK MESSAGE ON MCDU,
VISUAL CHECK AND LEAK CHECK
BOOTS

OPT TEST OF AFCS COMPUTER


CHECK MESSAGE ON MCDU,
VISUAL CHECK AND LEAK CHECK
BOOTS

REMARK
CONTINUE TS / INPROGRESS
A/C DOCK IN AT HM BTH
AOG
OPEN
CLOSED/REOPEN
TR 72-500/600
MAINTENANCE ACTION

NEED ACTUATOR
P/N: 4170006310
PLEASE ARRANGE PART TO A/C STA RON

NEED AHRU
P/N: 7003360-946
PLEASE ARRANGE PART TO A/C STA RON

NO FEED BACK

NO FEED BACK
OPT TEST OF WEATHER RADAR GOOD, CONTINUE
MONITOR

FOR TROUBLESHOOTING, PERFORM XCHANGE R/H AND


L/H SERVICE PRESSURE REGULATOR, OPT ON GROUND
FOUND NORMAL

MONITOR DURING FLIGHT FOUND GOOD, OPT TEST


GOOD, CONTINUE MONITOR

PLEASE ARRANGE SPARE AP YAW ACTUATOR 19CA TO


A/C RON STATION

PERFORM REPLACE BOTH IGN PLUG ENG #1, CHECK


AND REPLACE FUEL FILTER, REPLACE EEC ENG #1 ,
POWER ASSURANCE CHECK FOUND GOOD, A/C
DECLARE SERVICEABLE
ESTIGATE
MAINTENANCE ACTION

RETIGHTED CLAMP INBOARD TO HEAT EXCHANGER D/T


LOOSE OPT TEST WITH ENG RUN FOUND GOOD DMI
CLOSE

PERFORM OPT TEST WITH ENGINE RUNNING, FOUND


ACW BTC INLINE. DMI CLOSED

NO FEED BACK

AFTER CHECK AVS/LAST LEG REPORT FOUND MESSAGE


19CA, REPLACE SERVO 19CA AND OPT TEST OF AUTO
PILOT GOOD. DMI CLOSED
CHECK MFC MAINTENANCE MEMORY RELATED BOOTS,
FOUND LH EMPENAGE BOOTS B FAIL, REOPEN DMI
WAITING PATCH REPAIR KITS DT LEAK
WO
STATUS
CLOSED

OPEN

OPEN

OPEN

MONITOR
MONITOR

CLOSED 18/10/2019

MONITOR

OPEN

SERVICEABLE
STATUS

CLOSED 18/10/2019

CLOSED 18/10/2019

OPEN

CLOSED 18/10/2019
REOPEN 18/10/2019
REMARK STA RON

NEED ACTUATOR
P/N: 4170006310 BDO
PLEASE ARRANGE PART TO A/C STA RON

NEED AHRU
P/N: 7003360-946 BDO
PLEASE ARRANGE PART TO A/C STA RON

NEED SERVICE PRESSURE REGULATOR.


P/N :3214102-4
PLEASE ARRANGE PART TO A/C STA RON

PERFORMED CHECK MESSAGE ON HF CTRL


PANEL FOUND NOT MSG . PERFORMED
FUCTIONAL TEST ON GROUND FOUND
NORMAL WORKING . P'SE MONITOR INFLIGHT
AFTER CHECK FOUND MSG RAI 7SQ PLEASE
UPG
ARRANGE PART TO A/C STA RON

NEED SERVICE PRESSURE REGULATOR.


P/N :3214102-4 BUW
PLEASE ARRANGE PART TO A/C STA RON

CHECK AVS/LAST LEG REPORT NO


MESSAGE,OPT TEST ON GROUND FOUND UPG
NORMAL, PLEASE CONTINUE MONITOR

MONITOR TODAY GOODS, READ


ACMS/AVS/LAST LEG REPORT NO MESSAGE PKU
RELATED TO AUTO PILOT

EEC ON NO FAULT
EEC FAULT CODE NO FAOUND MESSAGE
TURN ALL BLADE FOUND NO NOISE
KNO
CHECK EEC AND HMU CONNECTOR C/O, DO
PAC C/O, PLAN TO REPLACE EEC, WAITING
SPARE EEC
REMARK STA RON

COLLECT DATA BY ITT ENG #2

BLEED OFF PACK OFF : 398


BLEED ON PACK OFF : 411
BLEED ON PACK ON : 484
AUTO AND MAN MODE : WORKING
BDO
DUCT TEMP 15 DEG WITH RECIRC FAN OFF
( SET ON FULL COLD )

WILL BE CONTINUE TS ON NEXT NIGHT A/C


RON

BDO

KOE
NBX
NO REG ATA WO NO

1 PK-WJI 52-31 962863

2 PK-WFQ 34-25 963694

3 PK-WHK 21 964225

4 PK-WHM 22 966721

5 PK-WFY 23 966201
6 PK-WJK 34 966177

7 PK-WJK 22 966744

DMI OPEN
NO REG ATA
DATE/CAT

17/10/2019
1 PK-WHG 30-11
"B"

2 PK-WFG 22-15-1 18/10/2019 "A"


3 PK-WFZ 36-11-1 18/10/2019 "C"

18/10/2019 "C"
4 PK-WFL 34-55-1 REPETITIVE
PROBLEM

5 PK-WFS 23-11-1 18/10/2019 "D"


6 PK-WGI 23-22-1 18/10/2019 "D"
H
WO
ALERT NO
ISSUED

9/10/2019 104427

10/10/2019 SP TRICK

11/10/2019 104536

17/10/2019 SP TRICK

16/10/2019 SP TRICK
16/10/2019 SP TRICK

17/10/2019 SP TRICK

TS TAB
DMI NO
ISSUED

18/10/2019 0032245

19/10/2019 032552
19/10/2019 012545

19/10/2019 00000608

19/10/2019 00018024
19/10/2019 001029
HIGHLIGH
DISCREPANCIES

CARGO DOOR UNABLE ELECTRICAL


OPEN

EFIS COMP SOMETIMES ILLUMINATE

CABIN DUCT TEMP ABOVE 50 DEG (DUCT


RISE AFTER TAKE OFF)

AP / YD DISCONNECT INFLT

HF UNABLE TO TRANSMIT
WX RADAR FAILED

AUTO PILOT U/S

DMI
DISCREPANCIES

AIRFRAME DEICING FAULT

DURING TAXI AHRS INVALID REPETITIVE


AND FGC JAMMED
COCKPIT DUCT TEMP /COMP TEMP
DURING AFTER T/O CRUISE . LANDING
INDICATE 40DEG /30 DEG

NAV 1 U/S NOT READING DME NORMAL

HF CANNOT TRANSMIT
SELCAL ALWAYS FLICKERING CAN'T BE
RESET
IGHLIGHT ATR 72-5
RECOMMENDATION

REPLACE CARGO DOOR


ACTUATOR
P/N :4170006310

RPLC AHRU #2
P/N : 7003360-946

LEAK CHK,RPLC SERVICE


PRESSURE REGULATOR
( 6142HQ )
P/N : 3214102-4

REPLACE AP YAW ACT ( 19 CA )

CHECK MESSAGE ON HF CTRL


PANEL, FUNCT TEST
REPLACED RADAR TRANCEIVER
7SQ

OPT TEST OF AUTO PILOT

DMI INVESTIGATE
RECOMMENDATION

CHECK MESSAGE ON MCDU,


VISUAL CHECK AND LEAK CHECK
BOOTS

CHK MSG ON ADU,OPT TEST


AHRS AS PER TSM 34-25-00 FIG
106 ,RPLC ADU, REPLACED FGC
OPT AIRCOND SYS ,CHECK LEAK
AND RETIGHTEN CLAMP
COLECT DATA .

CHECK MSG , REPLACED


ANTENNA

CHECK MESSAGE AT HF
CONTROL UNIT. REPLACED HF
TRANCEIVER
OPRATIONAL TEST SELCAL , X
CHANGE SELCAL SELECTION
PANEL 4RW WITH ANOTHER
A/C,REPLACED SELCAL
DECODER,

REMARK
CONTINUE TS / INPROGRESS
A/C DOCK IN AT HM BTH
AOG
OPEN
CLOSED/REOPEN
TR 72-500/600
MAINTENANCE ACTION

NEED ACTUATOR
P/N: 4170006310
PLEASE ARRANGE PART TO A/C STA RON

SPARE NOT AVAIL AT BDO

NEED SERVICE PRESSURE REGULATOR.


P/N :3214102-4
PLEASE ARRANGE PART TO A/C STA RON

PERFORMED CHK MSG SHOW 19CA,INSERT TO DMI DMI


WAITING SPARE SERVO 19CA

MONITOR 1 DAY FOUND GOOD


PROBLEM STILL APPEAR AND AFTER CHECK FOUND
MESSAGE 7SQ, INSERT TO DMI AND WAITING PART
RADAR TRANCEIVER 7SQ.

ESTIGATE
MAINTENANCE ACTION

PERF CHECK MSG ON MCDU FOUND L/H EMPNG BOOT A


FAIL ,L/H AND R/H WIG BOOT B FAIL . PERF LEAK CHECK
FOUND LEAK FROM WING BOOT . REOPEN DMI REQ
PATCH KIT

PERFORMED FGC AND AHRS TEST FOUND NORMAL


PLEASE MONITOR
COLLECT DATA AND TROUBLESHOOTING RELATED TO
ENG
ITT AND DUCT TEMPERATURE

RESULT
BLEED OFF: 425C
BLEED ON: 434C
PACK 1 ON : 470C
DUAL PACK ON : 472C

DUCT TEMP : 30C

TEMP SELECTOR:
AUTO : NOT SATISFIED
MANUAL: GOOD
FOR CONTINUE T/S PLEASE CREAT NEW TS TAB

RE OPEN DMI WAITNG SPARE VOR/MARKER/ILS/MKR


RECEIVER (1RE1)

PERFORMED OPRATIONAL TEST FOUND GOOD NOT


FAULT MSG . P'SE MONITOR INFLIGHT BEFOR CLOSED
DMI
PERFORMED CLEAND AND REPOST SELCAL DECODER ,
OPRATIONAL TEST SSELCAL FOUND GOOD DMI CLOSED
600
WO
STATUS
CLOSED

OPEN

OPEN

OPEN

CLOSED 19/10/2019

MONITOR
CLOSED 19/10/2019

MONITOR

STATUS

RE OPEN 19/10/2019

MONITOR
OPEN

CLOSED 19/10/2019

MONITOR
CLOSED 19/10/2019
REMARK STA RON

NEED ACTUATOR
P/N: 4170006310 BDO
PLEASE ARRANGE PART TO A/C STA RON

NEED AHRU
P/N: 7003360-946 BDO
PLEASE ARRANGE PART TO A/C STA RON

NEED SERVICE PRESSURE REGULATOR.


P/N :3214102-4 SWQ
PLEASE ARRANGE PART TO A/C STA RON

MONITOR TODAY GOODS, READ


ACMS/AVS/LAST LEG REPORT NO MESSAGE
RELATED TO AUTO PILOT PKU
PLEASE ARRANGE SPARE AP YAW ACTUATOR
19CA TO A/C RON STATION
PERFORMED CHECK MESSAGE ON HF CTRL
PANEL FOUND NOT MSG . PERFORMED
UPG
FUCTIONAL TEST ON GROUND FOUND
NORMAL WORKING . P'SE MONITOR INFLIGHT
AFTER CHECK FOUND MSG RAI 7SQ PLEASE
ARRANGE PART TO A/C STA RON
MDC
OPT TEST OF WEATHER RADAR GOOD,
CONTINUE MONITOR

CHECK AVS/LAST LEG REPORT NO


MESSAGE,OPT TEST ON GROUND FOUND MDC
NORMAL, PLEASE CONTINUE MONITOR

REMARK STA RON

WMX

BEJ
KOE

BDO

ROTE
BPN
NO REG ATA WO NO

1 PK-WJI 52-31 962863

2 PK-WFQ 34-25 963694

3 PK-WHK 21 964225

4 PK-WFY 23 966201

5 PK-WJK 22 966744
6 PK-WHT 27 LM

DMI OPEN
NO REG ATA
DATE/CAT

1 PK-WFZ 36-11-1 18/10/2019 "C"


4 PK-WGH 74-21-1 19/10/2019 "A"

3 PK-WHT 21-51-1 19/10/2019 "C"

4 PK-WFG 22-15-1 18/10/2019 "A"

5 PK-WFS 23-11-1 18/10/2019 "D"


H
WO
ALERT NO
ISSUED

9/10/2019 104427

10/10/2019 SP TRICK

11/10/2019 104536

16/10/2019 SP TRICK

17/10/2019 SP TRICK
20/10/2019 RTA

TS TAB
DMI NO
ISSUED

19/10/2019 012545
20/10/2019 00003109

20/10/2019 012193

19/10/2019 032552

19/10/2019 00018024
HIGHLIGH
DISCREPANCIES

CARGO DOOR UNABLE ELECTRICAL


OPEN

EFIS COMP SOMETIMES ILLUMINATE

CABIN DUCT TEMP ABOVE 50 DEG (DUCT


RISE AFTER TAKE OFF)

HF UNABLE TO TRANSMIT

AUTO PILOT U/S


PEC#2 FAULT

DMI
DISCREPANCIES

COCKPIT DUCT TEMP /COMP TEMP


DURING AFTER T/O CRUISE . LANDING
INDICATE 40DEG /30 DEG
START ENG 1A NO ITT

PACK #2 FAULT

DURING TAXI AHRS INVALID REPETITIVE


AND FGC JAMMED

HF CANNOT TRANSMIT
IGHLIGHT ATR 72-5
RECOMMENDATION

REPLACE CARGO DOOR


ACTUATOR
P/N :4170006310

RPLC AHRU #2
P/N : 7003360-946

LEAK CHK,RPLC SERVICE


PRESSURE REGULATOR
( 6142HQ )
P/N : 3214102-4

CHECK MESSAGE ON HF CTRL


PANEL, FUNCT TEST

OPT TEST OF AUTO PILOT


CHECK MSG , DVI DUAL COIL
SPEED PICK UP AND
CONNECTOR P2 PEC

DMI INVESTIGATE
RECOMMENDATION

CHECK OR REPLACE AUTO


TEMP CONTROLLER 9HH, FLT
COMP SENSOR 11 HH, DUCT
TEMP SENSOR 13HH, SKIN
SENSOR 15HH, COLECT DATA
.WITH INFRA RED FLUKE 561
REPLACED IGNITER PLUG, REPL
IGNITER EXCITER

CHECK ALL DUCT CONNECTION,


CLAMP PROPERLY AND
CHECK OF PACK
LEAKAGE...REPLACED PACK
VALVE #2

CHK MSG ON ADU,OPT TEST


AHRS AS PER TSM 34-25-00 FIG
106 ,RPLC ADU, REPLACED FGC

CHECK MESSAGE AT HF
CONTROL UNIT. REPLACED HF
TRANCEIVER

REMARK
CONTINUE TS / INPROGRESS
A/C DOCK IN AT HM BTH
AOG
OPEN
CLOSED/REOPEN
TR 72-500/600
MAINTENANCE ACTION

REPLACE CARGO DOOR ACTUATOR


P/N :4170006310

NEED AHRU
P/N: 7003360-946
PLEASE ARRANGE PART TO A/C STA RON

NEED SERVICE PRESSURE REGULATOR.


P/N :3214102-4
PLEASE ARRANGE PART TO A/C STA RON

MONITOR TODAY RESULT NORMAL

AFTER MONITOR INFLIGHT FOUND AUTO PILOT NORMAL


OPRATION . AND CHECK AVS/LAST LEG REPORT NO
MESSAGE.
REPLACED SPEED SENSOR ACT, PLATE ANTI ROTATION
AND ADJUSTMENT TARGET PICK UP C/O.
ENG GROUND RUN #2 FOUND GOOD,A/C SERVICEABLE

ESTIGATE
MAINTENANCE ACTION

FOR TROUBLE SHOOT PERFORMED X CHANGE FLT


COMPT CONTOLLER WITH CABIN CONTROLLER AND
CAN'T RUNNING ENG D/T NOT APPROVE FROM
AUTHORITY,PLEASE MONITOR TODAY,
REPLACED IGN PLUG "A" ENGINE #1 AND OPT TEST
GRND RUN ENGINE #1 START WITH IGN "A" FOUND
GOOD. DMI CLOSED

SWAP PACK VALVE #2 WITH #1, OPT TEST WITH GRND


RUN ENGINE BOTH PACK NO FOUND FAULT. CONT
MONITOR

CHECK MESSAGE ON ADU NO FOUND MESSAGE, AHRS


TEST NORMAL AND MONITOR 2 DAY FOUND GOOD.
DMI CLOSED

CHECK MESSAGE AT HF CTRL UNIT NO MESSAGE, TEST


FOUND OK.
PLEASE CONT MONITOR DURING FLIGHT
600
WO
STATUS
CLOSED

OPEN

OPEN

OPEN

MONITOR

CLOSED 20/10/2019
CLOSED 20/10/2019

STATUS

OPEN
CLOSED 20/10/2019

MONITOR

CLOSED 20/10/2019

MONITOR
REMARK STA RON

NEED ACTUATOR
P/N: 4170006310 PLM
PLEASE ARRANGE PART TO A/C STA RON

NEED AHRU
P/N: 7003360-946 BPN
PLEASE ARRANGE PART TO A/C STA RON

NEED SERVICE PRESSURE REGULATOR.


P/N :3214102-4 SWQ
PLEASE ARRANGE PART TO A/C STA RON

PERFORMED CHECK MESSAGE ON HF CTRL


PANEL FOUND NOT MSG . PERFORMED
SOC
FUCTIONAL TEST ON GROUND FOUND
NORMAL WORKING . P'SE MONITOR INFLIGHT

CHECK AVS/LAST LEG REPORT NO


MESSAGE,OPT TEST ON GROUND FOUND GTO
NORMAL, PLEASE CONTINUE MONITOR
AFTER CHECK FOUND TARGET SPEED
SENSOR BROKEN WAITING SPARE
1. TARGET SPEED SENSOR P/N. 817516-1 AVAIL
S1 DPS
2. PLATE ANTI ROTASION P/N 802391 AVAIL
K110
3. PLATE ANTI ROTASION P/N 810545-1 AVAIL
K110

REMARK STA RON

COLLECT DATA AND TROUBLESHOOTING


RELATED TO ENG
ITT AND DUCT TEMPERATURE

RESULT
BLEED OFF: 425C
BLEED ON: 434C
PACK 1 ON : 470C
DUAL PACK ON : 472C KOE

DUCT TEMP : 30C

TEMP SELECTOR:
AUTO : NOT SATISFIED
MANUAL: GOOD
FOR CONTINUE T/S PLEASE CREAT NEW TS
TAB
BDO

DPS

PERFORMED FGC AND AHRS TEST FOUND


BDJ
NORMAL PLEASE MONITOR

PERFORMED OPRATIONAL TEST FOUND


KOE
GOOD NOT FAULT MSG . P'SE MONITOR
NO REG ATA WO NO

1 PK-WJI 52-31 962863

2 PK-WFQ 34-25 963694

3 PK-WHK 21 964225

4 PK-WFY 23 966201

5 PK-WFI 34 967753
6 PK-WFS 72 967896

DMI OPEN
NO REG ATA
DATE/CAT

1 PK-WFZ 36-11-1 18/10/2019 "C"


2 PK-WHT 21-51-1 19/10/2019 "C"

3 PK-WFS 23-11-1 18/10/2019 "D"


H
WO
ALERT NO
ISSUED

9/10/2019 104427

10/10/2019 SP TRICK

11/10/2019 104536

16/10/2019 SP TRICK

21/10/2019 104985
21/10/2019 SP TRICK

TS TAB
DMI NO
ISSUED

19/10/2019 012545
20/10/2019 012193

19/10/2019 00018024
HIGHLIGH
DISCREPANCIES

CARGO DOOR UNABLE ELECTRICAL


OPEN

EFIS COMP SOMETIMES ILLUMINATE

CABIN DUCT TEMP ABOVE 50 DEG (DUCT


RISE AFTER TAKE OFF)

HF UNABLE TO TRANSMIT

GNSS DISPLAY INTERMITTENLY BLANK


ENG #1 SIGN OIL LEAK

DMI
DISCREPANCIES

COCKPIT DUCT TEMP /COMP TEMP


DURING AFTER T/O CRUISE . LANDING
INDICATE 40DEG /30 DEG
PACK #2 FAULT

HF CANNOT TRANSMIT
IGHLIGHT ATR 72-5
RECOMMENDATION

REPLACE CARGO DOOR


ACTUATOR
P/N :4170006310

RPLC AHRU #2
P/N : 7003360-946

LEAK CHK,RPLC SERVICE


PRESSURE REGULATOR
( 6142HQ )
P/N : 3214102-4

CHECK MESSAGE ON HF CTRL


PANEL, FUNCT TEST

REPLACE MCDU
TAPING ,DVI, TORQUE CHECK OF
FLANGE NUTS

DMI INVESTIGATE
RECOMMENDATION

RECONFIRM OF COLLECTING
DATA : OPT TEST OF AUTO AND
MANUAL CONTROL , COLLECT
DATA TEMPERATURE WITH
INFRARED THERMOMETER
CHECK ALL DUCT CONNECTION,
CLAMP PROPERLY AND
CHECK OF PACK
LEAKAGE...REPLACED PACK
VALVE #2

CHECK MESSAGE AT HF
CONTROL UNIT. REPLACED HF
TRANCEIVER

REMARK
CONTINUE TS / INPROGRESS
A/C DOCK IN AT HM BTH
AOG
OPEN
CLOSED/REOPEN
TR 72-500/600
MAINTENANCE ACTION

PLEASE ARRANGE SPARE

AFTER REPLACE AHRU FOUND GOOD CONTINUE


MONITOR

LEAK CHK NO FOUND LEAK PLEASE ARRANGE SPARE TO


A/C RON

CONTINUE MONITOR

NO INFO FROM EIC


VISUAL CHECK NO FOUND LEAK, AND CAN'T APPROVE
RUN ENG

ESTIGATE
MAINTENANCE ACTION

PLEASE ARRANGE TOOL INFRARED THERMOMETER


AFTER MONITOR ONE DAYS FOUND NORMAL

CONTINUE MONITOR
600
WO
STATUS
CLOSED

OPEN

MONITOR

OPEN

MONITOR

OPEN
OPEN

STATUS

OPEN
DMI CLOSED 21/10/2019

MONITOR
REMARK STA RON

NEED ACTUATOR
P/N: 4170006310 PKU
PLEASE ARRANGE PART TO A/C STA RON

NEED AHRU
P/N: 7003360-946 BPN
PLEASE ARRANGE PART TO A/C STA RON

NEED SERVICE PRESSURE REGULATOR.


P/N :3214102-4 KOE
PLEASE ARRANGE PART TO A/C STA RON

PERFORMED CHECK MESSAGE ON HF CTRL


PANEL FOUND NOT MSG . PERFORMED
SOC
FUCTIONAL TEST ON GROUND FOUND
NORMAL WORKING . P'SE MONITOR INFLIGHT
LBJ

REMARK STA RON

COLLECT DATA AND TROUBLESHOOTING


RELATED TO ENG
ITT AND DUCT TEMPERATURE

RESULT
BLEED OFF: 425C
BLEED ON: 434C
PACK 1 ON : 470C
DUAL PACK ON : 472C
SWQ
DUCT TEMP : 30C

TEMP SELECTOR:
AUTO : NOT SATISFIED
MANUAL: GOOD
FOR TROUBLE SHOOT PERFORMED X
CHANGE FLT COMPT CONTOLLER WITH CABIN
CONTROLLER
AUTO : NOT SATISFIED
MANUAL: GOOD
FOR TROUBLE SHOOT PERFORMED X
CHANGE FLT COMPT CONTOLLER WITH CABIN
CONTROLLER

SWAP PACK VALVE #2 WITH #1, OPT TEST


WITH GRND RUN ENGINE BOTH PACK NO SRG
FOUND FAULT. CONT MONITOR

CHECK MESSAGE AT HF CTRL UNIT NO


MESSAGE, PERFORMED OPRATIONAL TEST
SWQ
FOUND GOOD NOT FAULT MSG . P'SE
MONITOR
NO REG ATA WO NO

1 PK-WJI 52-31 962863

2 PK-WFQ 34-25 968581

3 PK-WHK 21 964225

4 PK-WFY 23 966201
5 PK-WFI 34 967753

6 PK-WFS 72 967896

7 PK-WFL 72 968398

8 PK-WGI

DMI OPEN
NO REG ATA
DATE/CAT
1 PK-WFZ 36-11-1 18/10/2019 "C"
2 PK-WFS 23-11-1 18/10/2019 "D"

3 PK-WGS AOG
HIG
WO
ALERT NO
ISSUED

9/10/2019 104427

22/10/2019 SP TRICK

11/10/2019 104536

16/10/2019 SP TRICK
21/10/2019 104985

21/10/2019 SP TRICK

22/10/2019 SP TRICK

TS TAB
DMI NO
ISSUED
19/10/2019 012545
19/10/2019 00018024
HIGHLIGHT
DISCREPANCIES

CARGO DOOR UNABLE ELECTRICAL OPEN

EFIS COMP SOMETIMES ILLUMINATE

CABIN DUCT TEMP ABOVE 50 DEG (DUCT


RISE AFTER TAKE OFF)

HF UNABLE TO TRANSMIT
GNSS DISPLAY INTERMITTENLY BLANK

ENG #1 SIGN OIL LEAK

ENG#2 NOT ACHIEVE TK OFF POWER


(INTERMITTEN)

DURINNG DAILY PERFORMED W/O COMP


WASH FOUND R/H ARROW BATT DISCHARGE
NOT ILL WHEN SELECT ENG START SW TO
OUT FROM OFF AND START ABORT

DMI I
DISCREPANCIES
COCKPIT DUCT TEMP /COMP TEMP DURING
AFTER T/O CRUISE . LANDING INDICATE
40DEG /30 DEG
HF CANNOT TRANSMIT

DC GEN FAULT ENG #1 AND ALSO START


FAULT AFTER NH RAISE 5%
HLIGHT ATR 72-500
RECOMMENDATION

REPLACE CARGO DOOR ACTUATOR


P/N :4170006310

D/T PREVIOUS PART INSTALLED WAS FROM


REPAIR SHOP, PLEASE EXCHANGE THE AHRU

EXCHANGE SERVICE PRESSURE REGULATOR


WITH FLIGHT COMPARTMENT

CHECK MESSAGE ON HF CTRL PANEL, FUNCT


TEST
REPLACE MCDU

TAPING ,DVI, TORQUE CHECK OF FLANGE NUTS


AND REPLACCE TQ SENSORS PACKING ENG#1 N1
(LEFT SIDE)

EXCHANGE EEC AND COLLECT PAC DATA AFTER


EXCHANGE

REPLACE CONTACTOR 3PA

DMI INVESTIGATE
RECOMMENDATION
EXCHANGE HP VLV AND RECONFIRM OF
COLLECTING DATA : OPT TEST OF AUTO AND
MANUAL CONTROL , COLLECT DATA
TEMPERATURE WITH INFRARED THERMOMETER
(TOOL ALREADY REQUEST TO MCC/ AVAILABLE S1
&K5)
CHECK MESSAGE AT HF CONTROL UNIT, CHECK
PTT SWITCH 14RN1 (14RN2) ON CTRL WHEEL, RAD
PTT SWITCH 13RN ON THE STEERING AND
INTH/RAD PTT SWITCH 15RN ON RACK 80VU,
REPLACED HF TRANCEIVER

IF PROBLEM STILL PERSIST, REPLACE STARGEN


AND WIRING CHECK

REMARK
CONTINUE TS / INPROGRESS
A/C DOCK IN AT HM BTH
AOG
OPEN
CLOSED/REOPEN
72-500/600
MAINTENANCE ACTION

AFTER MONITOR FOUND SATISFIED

EXCHANGE AHRU NO 2 WITH AHRU NO 1 PLEASE


CONTINUE MONITOR

NO INFO FROM EIC

NO REPORT ANYMORE
OPEN DMI WAITING SPARE MCDU

WAITING MP EBU AND BOROSCOPE, DEVELOPER

NO INFO FROM EIC

AFTER EXCHANGE CONTACTOR 3PA WITH 58PA


PROBLEM MOVE WAITING SPARE CONTACTOR 3PA

ATE
MAINTENANCE ACTION
EXCHANGE HP VALVE R/H TO L/H FOUND CABIN DUCT
TEMP 20'C WILL BE CONTINUE TO NIGHT
REOPEN DMI WAITING SPARE COAXIAL CABLE

SWAP GCU PROBLEM STILL, CHECK S/G BRUSH AND


TERMINAL IS GOOD, Replace HES 3PU and run problem still,
Ex 3PU install on 7PU problem still, Swap 7PU with 8PU and
Swap 12PU with 11PU STILL,progres swap dc gen #1 with dc
gen #2
WO
STATUS
CLOSED

CLOSED 22/10/2019

MONITOR

OPEN

CLOSED 22/10/2019
CLOSED 22/10/2019

AOG
OPEN

AOG

STATUS
OPEN
DMI CLOSED 22/10/2019

AOG
REMARK STA RON

NEED ACTUATOR
P/N: 4170006310 PKU
PLEASE ARRANGE PART TO A/C STA RON

AFTER REPLACE AHRU AND MONITOR STILL


RE-OCCUR WITH SYMPTOM EFIS COMP
BPN
ILLUMINATE INVOLVONG F/O EADI ROLL
MESSAGE APPEAR

NEED SERVICE PRESSURE REGULATOR.


P/N :3214102-4
PLEASE ARRANGE PART TO A/C STA RON

PERFORMED CHECK MESSAGE ON HF CTRL


PANEL FOUND NOT MSG . PERFORMED
SOC
FUCTIONAL TEST ON GROUND FOUND
NORMAL WORKING . P'SE MONITOR INFLIGHT
SRG

KOE

UPG

REMARK STA RON


COLLECT DATA AND TROUBLESHOOTING
RELATED TO ENG
ITT AND DUCT TEMPERATURE

RESULT
BLEED OFF: 425C
BLEED ON: 434C
PACK 1 ON : 470C
DUAL PACK ON : 472C
KOE
DUCT TEMP : 30C

TEMP SELECTOR:
AUTO : NOT SATISFIED
MANUAL: GOOD
FOR TROUBLE SHOOT PERFORMED X
CHANGE FLT COMPT CONTOLLER WITH CABIN
CONTROLLER
CHECK MESSAGE AT HF CTRL UNIT NO
MESSAGE, PERFORMED OPRATIONAL TEST
FOUND GOOD NOT FAULT MSG . P'SE SWQ
MONITOR , AFTER MONITOR FOUND HF CAN
RECEIVE BUT CAN'T TRANSMIT.

AMQ
WO
NO REG ATA WO NO
ISSUED

1 PK-WGV 28 969219 23/10/2019

2 PK-WGT 70 969359 23/10/2019

3 PK-WFL 72 968398 22/10/2019

4 PK-WHK 21 964225 11/10/2019


5 PK-WFQ 34-25 968581 22/10/2019

6 PK-WGI

7 PK-WFS 72 967896 21/10/2019

DMI OPEN TS TAB


NO REG ATA
DATE/CAT ISSUED
20/10/2019
1 PK--WGG 23-11-1 20/10/2019
"D"

22/10/2019
2 PK-WGH 22-18-1 22/10/2019
''B''

18/10/2019
3 PK-WFZ 36-11-1 19/10/2019
"C"
21/10/19
4 PK-WGJ 26/11/1 21/10/2019
''C''

20/10/2019
5 PK-WFL 33-43-1 20/10/2019
''D''

6 PK-WGS
HIGHLIG
ALERT NO DISCREPANCIES

FUEL QTY DIFFERENT BETWEEN RH


SP TRICK
AND LH

ENG #2 REPORTED HIGH CONSUMP

ENG #2 NOT ACHIEVE TK OFF


SP TRICK
POWER (INTERMITTEN)

CABIN DUCT TEMP ABOVE 50 DEG


104536
(DUCT RISE AFTER TAKE OFF)
EFIS COMP SOMETIMES
SP TRICK
ILLUMINATE

DURINNG DAILY PERFORMED W/O


COMP WASH FOUND R/H ARROW
BATT DISCHARGE NOT ILL WHEN
SELECT ENG START SW TO OUT
FROM OFF AND START ABORT

SP TRICK ENG #1 SIGN OIL LEAK

DMI NO DISCREPANCIES
0032084 HF CANNOT TRANSMIT

00003110 A/P U/S

COCKPIT DUCT TEMP /COMP TEMP


012545 DURING AFTER T/O CRUISE .
LANDING INDICATE 40DEG /30 DEG
00018699 LOOP 2A FAULT

R/H STROBE LIGHT NOT


00000610
ILLUMINATE

DC GEN FAULT ENG #1 AND ALSO


START FAULT AFTER NH RAISE 5%
HIGHLIGHT ATR 72
RECOMMENDATION

RPLC FUEL HARNESS 14QT

INSPECT BREATHER TUBE,EXHAUST


AND EXTERNAL AREA

X-CHANGE EEC AND COLLECT PAC


DATA AFTER X-CHANGE

X-CHANGE SERVICE PRESSURE


REGULATOR WITH FLIGHT
COMPARTMENT
D/T PREVIOUS PART INSTALLED WAS
FROM REPAIR SHOP, PLEASE
EXCHANGE THE AHRU

REPLACE CONTACTOR 3PA

TAPING ,DVI, TORQUE CHECK OF


FLANGE NUTS AND REPLACCE TQ
SENSORS PACKING ENG#1 N1 (LEFT
SIDE)

DMI INVESTIGATE
RECOMMENDATION
OPT TEST OF HF SYSTEM,CHK MSG
AND RPLC HF TX

CHK MSG,GRD MAINT TEST OF AFCS,

EXCHANGE HP VLV AND RECONFIRM


OF COLLECTING DATA : OPT TEST OF
AUTO AND MANUAL CONTROL ,
COLLECT DATA TEMPERATURE WITH
INFRARED THERMOMETER (TOOL
ALREADY REQUEST TO MCC/
AVAILABLE S1 &K5)
DVI AND RESISTANCE CHECK OF
SENSING ELEMENTS

RPLC STROBE LT,RPLC PWR SUPPLY


& WIRING CHK

IF PROBLEM STILL PERSIST, RPLC


STARGEN AND WIRING CHK

REMARK
CONTINUE TS / INPROGRESS
HM BTH
AOG
OPEN
CLOSED/REOPEN
ATR 72-500/600
MAINTENANCE ACTION

PROBLEM SOMETIMES STILL EXIST.


SPARE HARNESS 14QT NOT AVAIL AT MKW.
PN : 796-948-2
PLEASE ARRANGE SPARE TO A/C STA RON

CAN'T PERFORM D/T HEAVY RAIN AT PKU.


INFO EIC TODAY ENG #2 OIL ADDED 2 QRTS FOR 11
HOURS

1. PERFORMED CHECK EEC MSG FOUND CODE 87 , 86


2. PERFORMED CLEAN AND REPOST ELEC PLUG EEC
3. CHECK P3 AND PY TUBING
4. ERASE AND TRIMING EEC AND PEC
5. PERFORMED PAC

PERORM X-CHANGE SPR C/O.OPT TEST FOUND BOTH


DUCT TEMP 10*C.
W/O CLOSED
PLEASE MONITOR INFLIGHT
AFTER X-CHANGE AHRU #2 WITH AHRU #1 AND
MONITOR TODAY 8 LANDING EFIS COMP NOT
ILLUMINATE.
W/O CLOSED
CONTINUE MONITOR

PERFORMED REPLACE CONTACTOR 3PA OPT TEST


FOUND GOOD A/C.
SERVICEABLE

AFTER BSI FOUND OIL LEAK FROM FLANGE RGB.


PLAN AFTER MRB RAI ENGINE 0N OCT 25,2019

ESTIGATE
MAINTENANCE ACTION
PROBLEM SOMETIMES STILL EXIST.
GROUND OPT TEST PASS.
PLEASE ARRANGE SPARE HF TRANSCEIVER 1RE2.
PN : 822-0101-002
TO A/C STA RON

CHK MSG 18CA.PERFORM X-CHANGE 18CA WITH


19CA.GRD OPT TEST FOUND PASS.PLEASE
MONITOR INFLIGHT

PERFORM ISOLATE TCV COCKPIT C/O.


PLEASE MONITOR TOMORROW D/T OPERATING
HOUR LIMIT FOR ERU AT SWQ
AFTER DVI FOUND SENSING ELEMENT 30WD BOBBIN
WAS MISSING 1 EA.REOPEN DMI D/T WAITING
SPARE.
PN : ASNA2161-01
PLEASE ARRANGE SPARE TO A/C STA RON
AVAIL AT K104

RESISTANCE CHK :
SENSING ELEMENT 156WD2>>>36.4 OHM
SENSING ELEMENT 150WD2>>>14.8 OHM
SENSING ELEMENT 30WD>>>>>34 OHM
SENSING ELEMENT 31WD2>>>>9.9 OHM
SENSING ELEMENT 34WD2>>>>10 OHM

PERFORM REPLACE RH STROBE LIGHT BULB C/O.OPT


TEST FOUND GOOD.
DMI CLOSED

PERFORM REPLACE STARGEN #1 C/O.OPT TEST


FOUND GOOD
A/C SERVICEABLE
/600
WO
STATUS
CLOSED

OPEN

OPEN

OPEN

MONITOR
MONITOR

CLOSED 23/10/2019

AOG

STATUS
OPEN

MONITOR

MONITOR
REOPEN 23/10/2019

CLOSED 23/10/2019

CLOSED 23/10/2019
REMARK STA RON

MKW

PKU

SUB

NEED SERVICE PRESSURE REGULATOR.


P/N :3214102-4 KOE
PLEASE ARRANGE PART TO A/C STA RON
1.AFTER REPLACE AHRU AND MONITOR STILL
RE-OCCUR WITH SYMPTOM EFIS COMP
ILLUMINATE INVOLVONG F/O EADI ROLL
BPN
MESSAGE APPEAR
2. EXCHANGE AHRU NO 2 WITH AHRU NO 1
PLEASE CONTINUE MONITOR

AFTER EXCHANGE CONTACTOR 3PA WITH 58PA


PROBLEM MOVE WAITING SPARE CONTACTOR UPG
3PA

WAITING MP EBU AND BOROSCOPE, DEVELOPER KOE

REMARK STA RON


BDJ

SUB

1. COLLECT DATA AND TROUBLESHOOTING


RELATED TO ENG
ITT AND DUCT TEMPERATURE
RESULT
BLEED OFF: 425C
BLEED ON: 434C
PACK 1 ON : 470C
DUAL PACK ON : 472C
DUCT TEMP : 30C
SWQ
TEMP SELECTOR:
AUTO : NOT SATISFIED
MANUAL: GOOD
FOR TROUBLE SHOOT PERFORMED X CHANGE
FLT COMPT CONTOLLER WITH CABIN
CONTROLLER
2. EXCHANGE HP VALVE R/H TO L/H FOUND
CABIN DUCT TEMP 20'C WILL BE CONTINUE TO
NIGHT
UPG

SUB

SWAP GCU PROBLEM STILL,


CHECK S/G BRUSH AND TERMINAL IS GOOD,
Replace HES 3PU and run problem still,
Ex 3PU install on 7PU problem still,
Swap 7PU with 8PU and Swap 12PU with 11PU AMQ
STILL,
progress swap dc gen #1 with dc gen #2
AFTER X-CHANGE STARGEN PROBKEM
MOVE.WAITING SPARE STARGEN
NO REG ATA WO NO

1 PK-WGV 28 969219

2 PK-WGT 70 969359

3 PK-WHK 72 969895

4 PK-WHM 22 969883
5 PK-WFQ 34-25 968581

6 PK-WHK 21 964225

7 PK-WFS 72 967896
8 PK-WFL 72 968398

DMI OPEN
NO REG ATA
DATE/CAT

20/10/2019
1 PK--WGG 23-11-1
"D"

18/10/2019
2 PK-WFZ 36-11-1
"C"
18/10/2019
2 PK-WFZ 36-11-1
"C"

24/10/19
3 PK-WGQ 33-48-1
''C''

22/10/2019
4 PK-WGH 22-18-1
''B''
HI
WO
ALERT NO
ISSUED

23/10/2019 SP TRICK

23/10/2019

24/10/2019 SP TRICK

24/10/2019 105156
22/10/2019 SP TRICK

11/10/2019 104536

21/10/2019 SP TRICK
22/10/2019 SP TRICK

TS TAB
DMI NO
ISSUED

20/10/2019 0032084

19/10/2019 012545
19/10/2019 012545

24/10/2019 0024030

22/10/2019 00003110
HIGHLIGHT
DISCREPANCIES

FUEL QTY DIFFERENT BETWEEN


RH AND LH

ENG #2 REPORTED HIGH CONSUMP

ENG 2 FUEL TEMP HIGH

A/P DISCONNECTED INFLIGHT


SEVERAL TIMES
EFIS COMP SOMETIMES
ILLUMINATE

CABIN DUCT TEMP ABOVE 50 DEG


(DUCT RISE AFTER TAKE OFF)

ENG #1 SIGN OIL LEAK


ENG #2 NOT ACHIEVE TK OFF
POWER (INTERMITTEN)

DMI I
DISCREPANCIES

HF CANNOT TRANSMIT

COCKPIT DUCT TEMP /COMP TEMP


DURING AFTER T/O CRUISE .
LANDING INDICATE 40DEG /30 DEG
COCKPIT DUCT TEMP /COMP TEMP
DURING AFTER T/O CRUISE .
LANDING INDICATE 40DEG /30 DEG

BEACON LT CB POP OUT

A/P U/S
IGHLIGHT ATR 72-
RECOMMENDATION

REPLACE FUEL HARNESS 14QT

INSPECT BREATHER
TUBE,EXHAUST AND EXTERNAL
AREA

REPLACE THERMAL
ELEMENT/OPEN DMI

REPLACE SERVO 19 CA
D/T PREVIOUS PART INSTALLED
WAS FROM REPAIR SHOP,
PLEASE EXCHANGE THE AHRU

X-CHANGE SERVICE PRESSURE


REGULATOR WITH FLIGHT
COMPARTMENT

TAPING ,DVI, TORQUE CHECK OF


FLANGE NUTS AND REPLACCE TQ
SENSORS PACKING ENG#1 N1
(LEFT SIDE)
X-CHANGE EEC AND COLLECT
PAC DATA AFTER X-CHANGE

DMI INVESTIGATE
RECOMMENDATION

OPT TEST OF HF SYSTEM,CHK


MSG AND RPLC HF TX

EXCHANGE HP VLV AND


RECONFIRM OF COLLECTING
DATA : OPT TEST OF AUTO AND
MANUAL CONTROL , COLLECT
DATA TEMPERATURE WITH
INFRARED THERMOMETER (TOOL
EXCHANGE HP VLV AND
RECONFIRM OF COLLECTING
DATA : OPT TEST OF AUTO AND
MANUAL CONTROL , COLLECT
DATA TEMPERATURE WITH
INFRARED THERMOMETER (TOOL
ALREADY REQUEST TO MCC/
AVAILABLE S1 &K5)

WIRING CHECK

CHK MSG,GRD MAINT TEST OF


AFCS,
REMARK
CONTINUE TS / INPROGRESS
AOG
HM BTH
CLOSED/REOPEN
ATR 72-500/600
MAINTENANCE ACTION

WAITING SPARE 14QT.


PLEASE ARRANGE SPARE TO A/C STA RON

CAN'T PERFORM D/T A/C TOWING TO HANGGAR


FOR WEIGHT & BALANCE

AFTER MONITOR TODAY FUEL TEMP ENG #2


NORMAL.
PLEASE CONTINUE MONITOR INFLIGHT

INFO EIC A/P INFLIGHT FOUND GOOD.


GROUND OPT TEST FOUND GOOD.
PLEASE ARRANGE SPARE SERVO 19CA TO A/C STA
RON & CONTINUE MONITOR
AFTER MONITOR TODAY EFIS COMP WAS NOT
ILLUMINATE.
W/O CLOSED

AFTER MONITOR TODAY BOTH DUCT TEMPS WAS


GOOD.
W/O CLOSED

AFTER MAKESURE ROOT CAUSED LEAK FROM 2


SOURCES:
1. REPLACE LH TQ SENSOR PACKING
2.RETIGHTENED CONNECTION TUBING HOSE TO
FCOC.
ENG #1 RUN FOUND GOOD (NO SIGN OIL LEAK)
A/C SERVICEABLE
WAITING SPARE EEC & MPC FOR CONTINUE
TROUBLE SHOOT.
TROULE SHOOT STILL IN PROGRESS

ESTIGATE
MAINTENANCE ACTION

WAITING SPARE HF TRANSCEIVER.


PLEASE ARRANGE SPARE TO A/C STA RON

ITT
ENG #1 ENG #2
1. BLEED OFF PACK OFF 387 395
2. BLEED ON PACK OFF 398 405
3. BLEED ON PACK ON 435 479

DUCT TEMP FLT COMP CABIN COMP


22*C 10*C
PRIMARY H.E IN : 95*C
PRIMARY H.E OUT : 50*C
DELTA TEMP : 45*C
SECONDARY H.E IN : 85*C
SECONDARY H.E OUT : 44*C
DELTA TEMP : 41*C
ACM COMPRESSOR IN : 103*C
ACM COMPRESSOR OUT : 105*C
DELTA TEMP : 2*C
ACM TURBINE OUT : 28*C
CONDENSOR BLEED AIR IN (7.1) : 33*C
CONDENSOR BLEED AIR OUT (7.2 ) : 13*C
DELTA TEMP : 20*C
CONDENSOR COLD AIR OUT (7.3) : 13*C
WATER EXTRACTOR IN : 33*C
TICV OUT : 41*C

AFTER TROUBLE SHOOT FOUND LOWER BEACON


LIGHT ASSY & POWER SUPPLY UNIT WAS BAD.
REOPEN DMI D/T WAITING SPARE :
1. ANTI COLLOTION LIGHT
PN : R25-1M2CW
2. POWER SUPPLY UNIT
PN : APS40-1

AFTER MONITOR A/P INFLIGHT WAS GOOD.


DMI CLOSED
/600
WO
STATUS
CLOSED

OPEN

OPEN

OPEN

MONITOR
W/O 24/10/2019
CLOSED

W/O 24/10/2019
CLOSED

CLOSED 24/10/2019
AOG

STATUS

OPEN

MONITOR
MONITOR

REOPEN 24/10/2019

CLOSED 24/10/2019
REMARK STA RON

1. PROBLEM SOMETIMES STILL EXIST.


SPARE HARNESS 14QT NOT AVAIL AT MKW.
SOQ
PN : 796-948-2
PLEASE ARRANGE SPARE TO A/C STA RON

1. CAN'T PERFORM D/T HEAVY RAIN AT PKU.


INFO EIC TODAY ENG #2 OIL ADDED 2 QRTS BTH
FOR 11 HOURS

ENE

SUB
1.AFTER REPLACE AHRU AND MONITOR STILL
RE-OCCUR WITH SYMPTOM EFIS COMP
ILLUMINATE INVOLVONG F/O EADI ROLL
BPN
MESSAGE APPEAR
2. EXCHANGE AHRU NO 2 WITH AHRU NO 1
PLEASE CONTINUE MONITOR

1. NEED SERVICE PRESSURE REGULATOR.


P/N :3214102-4
PLEASE ARRANGE PART TO A/C STA RON
2. PERORM X-CHANGE SPR C/O.OPT TEST ENE
FOUND BOTH DUCT TEMP 10*C.
W/O CLOSED
PLEASE MONITOR INFLIGHT

AFTER BSI FOUND OIL LEAK FROM FLANGE


RGB. KOE
PLAN AFTER MRB RAI ENGINE 0N OCT 25,2019
1. PERFORMED CHECK EEC MSG FOUND
CODE 87 , 86
2. PERFORMED CLEAN AND REPOST ELEC
PLUG EEC
3. CHECK P3 AND PY TUBING SRG
4. ERASE AND TRIMING EEC AND PEC
5. PERFORMED PAC

REMARK STA RON


1. PROBLEM SOMETIMES STILL EXIST.
GROUND OPT TEST PASS.
PLEASE ARRANGE SPARE HF TRANSCEIVER
1RE2. BDJ
PN : 822-0101-002
TO A/C STA RON

1. COLLECT DATA AND TROUBLESHOOTING


RELATED TO ENG
ITT AND DUCT TEMPERATURE
RESULT
BLEED OFF: 425C
BLEED ON: 434C
PACK 1 ON : 470C
DUAL PACK ON : 472C
DUCT TEMP : 30C
TEMP SELECTOR:
AUTO : NOT SATISFIED KOE
MANUAL: GOOD
BLEED ON: 434C
PACK 1 ON : 470C
DUAL PACK ON : 472C
DUCT TEMP : 30C
TEMP SELECTOR:
AUTO : NOT SATISFIED KOE
MANUAL: GOOD
FOR TROUBLE SHOOT PERFORMED X
CHANGE FLT COMPT CONTOLLER WITH CABIN
CONTROLLER
2. EXCHANGE HP VALVE R/H TO L/H FOUND
CABIN DUCT TEMP 20'C WILL BE CONTINUE
TO NIGHT
3. PERFORM ISOLATE TCV COCKPIT C/O.
PLEASE MONITOR TOMORROW D/T
OPERATING HOUR LIMIT FOR ERU AT SWQ

KNO

1. CHK MSG 18CA.PERFORM X-CHANGE 18CA


WITH 19CA.GRD OPT TEST FOUND JOG
PASS.PLEASE MONITOR INFLIGHT
WO
NO REG ATA WO NO
ISSUED

1 PK-WGV 28 969219 23/10/2019

2 PK-WGT 70 969359 23/10/2019


3 PK-WHK 72 969895 24/10/2019

4 PK-WHM 22 969883 24/10/2019

5 PK-WFL 72 968398 22/10/2019


DMI OPEN TS TAB
NO REG ATA
DATE/CAT ISSUED

20/10/2019
1 PK--WGG 23-11-1 20/10/2019
"D"

18/10/2019
2 PK-WFZ 36-11-1 19/10/2019
"C"
18/10/2019
2 PK-WFZ 36-11-1 19/10/2019
"C"
HIGHLIGHT
ALERT NO DISCREPANCIES

FUEL QTY DIFFERENT BETWEEN


SP TRICK
RH AND LH

ENG #2 REPORTED HIGH CONSUMP


SP TRICK ENG 2 FUEL TEMP HIGH

A/P DISCONNECTED INFLIGHT


105156
SEVERAL TIMES

ENG #2 NOT ACHIEVE TK OFF


SP TRICK
POWER (INTERMITTEN)

DMI IN
DMI NO DISCREPANCIES

0032084 HF CANNOT TRANSMIT

COCKPIT DUCT TEMP /COMP TEMP


012545 DURING AFTER T/O CRUISE .
LANDING INDICATE 40DEG /30 DEG
COCKPIT DUCT TEMP /COMP TEMP
012545 DURING AFTER T/O CRUISE .
LANDING INDICATE 40DEG /30 DEG
HIGHLIGHT ATR 72-500
RECOMMENDATION

REPLACE FUEL HARNESS 14QT

INSPECT BREATHER
TUBE,EXHAUST AND EXTERNAL
AREA
REPLACE THERMAL
ELEMENT/OPEN DMI

REPLACE SERVO 19 CA

X-CHANGE EEC AND COLLECT


PAC DATA AFTER X-CHANGE

DMI INVESTIGATE
RECOMMENDATION

OPT TEST OF HF SYSTEM,CHK


MSG AND RPLC HF TX

EXCHANGE HP VLV AND


RECONFIRM OF COLLECTING
DATA : OPT TEST OF AUTO AND
MANUAL CONTROL , COLLECT
DATA TEMPERATURE WITH
INFRARED THERMOMETER (TOOL
ALREADY REQUEST TO MCC/
AVAILABLE S1 &K5)
MEASURE / REPLACE FLT COMP
SENSOR 11 HH. MEASURE /
REPLACE DUCT TEMP SENSOR
13HH, MEASURE / REPLACE SKIN
SENSOR 15HH

REMARK
CONTINUE TS / INPROGRESS
AOG
HM BTH
CLOSED/REOPEN
ATR 72-500/600
MAINTENANCE ACTION STATUS

OPEN DMI WAITING SPARE HARNESS 14QT CLOSED

A/C AT HMBTH FOR WEIGHT AND BALANCE OPEN


AFTER CHECK FOUND PROBLEM STILL EXIST,
TRANSFER TO DMI DT WAITING SPARE THERMAL CLOSED
ELEMENT

INFO EIC A/P INFLIGHT FOUND GOOD.


GROUND OPT TEST FOUND GOOD. MONITOR
PLEASE ARRANGE SPARE SERVO 19CA

PERFORM REPOST TRANSFER TUBE, POWER


ASSURANCE CHECK FOUND PARAMETER GOOD, SERVICEABLE
A/C DECLASE SS

VESTIGATE
MAINTENANCE ACTION STATUS

GROUND OPT TEST PASS.


PLEASE ARRANGE SPARE HF TRANSCEIVER 1RE2.
OPEN
PN : 822-0101-002
TO A/C STA RON

ITT
ENG #1 ENG #2
1. BLEED OFF PACK OFF 387 395
2. BLEED ON PACK OFF 398 405
3. BLEED ON PACK ON 435 479

DUCT TEMP FLT COMP CABIN COMP


22*C 10*C

MONITOR
MONITOR

CAN'T CONTINUE TROUBLESHOOTING D/T NOT


APPROVED ENGINE RUNNING AT ENE, PLEASE
LOCK RON A/C AT KOE FOR CONTINUE TS
WO
REMARK STA RON
CLOSED

1. PROBLEM SOMETIMES STILL EXIST.


SPARE HARNESS 14QT NOT AVAIL AT MKW.
PN : 796-948-2 FKQ
PLEASE ARRANGE SPARE TO A/C STA RON
2. WAITING SPARE 14QT

1. CAN'T PERFORM D/T HEAVY RAIN AT PKU.


INFO EIC TODAY ENG #2 OIL ADDED 2 QRTS HMBTH
FOR 11 HOURS
AFTER MONITOR TODAY FUEL TEMP ENG #2
NORMAL. KOE
PLEASE CONTINUE MONITOR INFLIGHT

INFO EIC A/P INFLIGHT FOUND GOOD.


GROUND OPT TEST FOUND GOOD. SUB
PLEASE ARRANGE SPARE SERVO 19CA

1. PERFORMED CHECK EEC MSG FOUND


CODE 87 , 86
2. PERFORMED CLEAN AND REPOST ELEC
PLUG EEC
3. CHECK P3 AND PY TUBING SRG
4. ERASE AND TRIMING EEC AND PEC
5. PERFORMED PAC
REMARK STA RON
1. PROBLEM SOMETIMES STILL EXIST.
GROUND OPT TEST PASS.
1. COLLECT
PLEASE DATA AND
ARRANGE TROUBLESHOOTING
SPARE HF TRANSCEIVER
RELATED
1RE2. TO ENG UPG
ITT
PNAND DUCT TEMPERATURE
: 822-0101-002
RESULT
TO A/C STA RON
BLEED OFF: 425C
BLEED ON: 434C
PACK 1 ON : 470C
DUAL PACK ON : 472C
DUCT TEMP : 30C
TEMP SELECTOR:
AUTO : NOT SATISFIED
MANUAL: GOOD
FOR TROUBLE SHOOT PERFORMED X
CHANGE FLT COMPT CONTOLLER WITH CABIN
CONTROLLER
2. EXCHANGE HP VALVE R/H TO L/H FOUND
CABIN DUCT TEMP 20'C WILL BE CONTINUE
TO NIGHT
3. PERFORM ISOLATE TCV COCKPIT C/O.
PLEASE MONITOR TOMORROW D/T
OPERATING HOUR LIMIT FOR ERU AT SWQ ENE
4. PRIMARY H.E IN : 95*C
PRIMARY H.E OUT : 50*C
CHANGE FLT COMPT CONTOLLER WITH CABIN
CONTROLLER
2. EXCHANGE HP VALVE R/H TO L/H FOUND
CABIN DUCT TEMP 20'C WILL BE CONTINUE
TO NIGHT
3. PERFORM ISOLATE TCV COCKPIT C/O.
PLEASE MONITOR TOMORROW D/T
OPERATING HOUR LIMIT FOR ERU AT SWQ ENE
4. PRIMARY H.E IN : 95*C
PRIMARY H.E OUT : 50*C
DELTA TEMP :
45*C
SECONDARY H.E IN : 85*C
SECONDARY H.E OUT : 44*C
DELTA TEMP :
41*C
ACM COMPRESSOR IN : 103*C
ACM COMPRESSOR OUT : 105*C
DELTA TEMP :
2*C
ACM TURBINE OUT : 28*C
CONDENSOR BLEED AIR IN (7.1) : 33*C
CONDENSOR BLEED AIR OUT (7.2 ) : 13*C
DELTA TEMP : 20*C
CONDENSOR COLD AIR OUT (7.3) : 13*C
WATER EXTRACTOR IN : 33*C
TICV OUT :
41*C
WO
NO REG ATA WO NO
ISSUED

1 PK-WGT 70 969359 23/10/2019

2 PK-WHM 22 969883 24/10/2019


3 PK-WGZ 21-31 970416 26/10/2019

4 PK-WFY 36 970431 26/10/2019

DMI OPEN TS TAB


NO REG ATA
DATE/CAT ISSUED

20/10/2019
1 PK--WGG 23-11-1 20/10/2019
"D"
18/10/2019
2 PK-WFZ 36-11-1 19/10/2019
"C"
18/10/2019
2 PK-WFZ 36-11-1 19/10/2019
"C"
3 PK-WFQ 34-12 26/10/2019
HIGHLIGHT
ALERT NO DISCREPANCIES

ENG #2 REPORTED HIGH CONSUMP

A/P DISCONNECTED INFLIGHT


105156
SEVERAL TIMES
DURING DESEND CABIN RATE LATE
TO DESEND CABIN RATE UP &
105275
DOWN TO LATE CATCH UP THE
TARGET CABIN ALT

BLEED LEAK ENG #1 SOMETIMES


APPEAR

DMI IN
DMI NO DISCREPANCIES

0032084 HF CANNOT TRANSMIT


COCKPIT DUCT TEMP /COMP TEMP
012545 DURING AFTER T/O CRUISE .
LANDING INDICATE 40DEG /30 DEG
COCKPIT DUCT TEMP /COMP TEMP
012545 DURING AFTER T/O CRUISE .
LANDING INDICATE 40DEG /30 DEG
ALTIMETER F/O SIDE INTERMITTEN
013318
LAGGING IN FLIGHT
HIGHLIGHT ATR 72-500
RECOMMENDATION

INSPECT BREATHER
TUBE,EXHAUST AND EXTERNAL
AREA

REPLACE SERVO 19 CA
REPLACE DIGITAL CONTROLLER
AND FUT TEST ON GROUND
CABIN PRESSURE CONTROL IN
AUTO MODE

REPLACE UNDER FLOOR DUCT


SEAL

DMI INVESTIGATE
RECOMMENDATION

OPT TEST OF HF SYSTEM,CHK


MSG AND RPLC HF TX
EXCHANGE HP VLV AND
RECONFIRM OF COLLECTING
DATA : OPT TEST OF AUTO AND
MANUAL CONTROL , COLLECT
DATA TEMPERATURE WITH
INFRARED THERMOMETER (TOOL
ALREADY REQUEST TO MCC/
AVAILABLE S1 &K5)
MEASURE / REPLACE FLT COMP
SENSOR 11 HH. MEASURE /
REPLACE DUCT TEMP SENSOR
13HH, MEASURE / REPLACE SKIN
SENSOR 15HH
OPT TEST OF AIR DATA SYSTEM,
VISUAL CHECK STATIC PROBES,
REPLACE ALTIMETER INDICATOR

REMARK
CONTINUE TS / INPROGRESS
AOG
HM BTH
CLOSED/REOPEN
ATR 72-500/600
MAINTENANCE ACTION STATUS

CAN'T PERFORM D/T HEAVY RAIN AT PKU OPEN

INFO EIC A/P INFLIGHT FOUND GOOD.


GROUND OPT TEST FOUND GOOD. MONITOR
PLEASE ARRANGE SPARE SERVO 19CA
NEED SPARE DIGITAL CONTROLLER, PLEASE
OPEN
ARANGE SPARE TO A/C RON STATION

WAITING SPARE UNDERFLOOR BLEED DUCT


AOG
SEAL,PLAN SPARE SEND VIA JT775

VESTIGATE
MAINTENANCE ACTION STATUS

1. PROBLEM SOMETIMES STILL EXIST.


GROUND OPT TEST PASS.
PLEASE ARRANGE SPARE HF TRANSCEIVER 1RE2. OPEN
PN : 822-0101-002
TO A/C STA RON
ITT
ENG #1 ENG #2
1. BLEED OFF PACK OFF 387 395
2. BLEED ON PACK OFF 398 405
3. BLEED ON PACK ON 435 479

DUCT TEMP FLT COMP CABIN COMP


22*C 10*C

CLOSED
CLOSED

AFTER MONITOR INFLIGHT FOUND COCKPIT DUCT


TEMEPERATURE 8 DEG CELCIUS, DMI CLOSED
AFTER CHECK FOUND FO ALT INDICATOR WAS
REOPEN
BAD, REOPEN D/T WAITING SPARE
WO
REMARK STA RON
CLOSED

1. CAN'T PERFORM D/T HEAVY RAIN AT PKU.


INFO EIC TODAY ENG #2 OIL ADDED 2 QRTS PKU
FOR 11 HOURS

INFO EIC A/P INFLIGHT FOUND GOOD.


GROUND OPT TEST FOUND GOOD. BDO
PLEASE ARRANGE SPARE SERVO 19CA
UPG

DPS

REMARK STA RON


1. PROBLEM SOMETIMES STILL EXIST.
GROUND OPT TEST PASS.
PLEASE ARRANGE SPARE HF TRANSCEIVER
1RE2. BUW
PN : 822-0101-002
TO A/C STA RON
1. COLLECT DATA AND TROUBLESHOOTING
RELATED TO ENG
ITT AND DUCT TEMPERATURE
RESULT
BLEED OFF: 425C
BLEED ON: 434C
PACK 1 ON : 470C
DUAL PACK ON : 472C
DUCT TEMP : 30C
TEMP SELECTOR:
AUTO : NOT SATISFIED
MANUAL: GOOD
FOR TROUBLE SHOOT PERFORMED X
CHANGE FLT COMPT CONTOLLER WITH CABIN
CONTROLLER
2. EXCHANGE HP VALVE R/H TO L/H FOUND
CABIN DUCT TEMP 20'C WILL BE CONTINUE
TO NIGHT
3. PERFORM ISOLATE TCV COCKPIT C/O.
PLEASE MONITOR TOMORROW D/T
OPERATING HOUR LIMIT FOR ERU AT SWQ KOE
4. PRIMARY H.E IN : 95*C
PRIMARY H.E OUT : 50*C
DELTA TEMP :
45*C
MANUAL: GOOD
FOR TROUBLE SHOOT PERFORMED X
CHANGE FLT COMPT CONTOLLER WITH CABIN
CONTROLLER
2. EXCHANGE HP VALVE R/H TO L/H FOUND
CABIN DUCT TEMP 20'C WILL BE CONTINUE
TO NIGHT
3. PERFORM ISOLATE TCV COCKPIT C/O.
PLEASE MONITOR TOMORROW D/T
OPERATING HOUR LIMIT FOR ERU AT SWQ KOE
4. PRIMARY H.E IN : 95*C
PRIMARY H.E OUT : 50*C
DELTA TEMP :
45*C
SECONDARY H.E IN : 85*C
SECONDARY H.E OUT : 44*C
DELTA TEMP :
41*C
ACM COMPRESSOR IN : 103*C
ACM COMPRESSOR OUT : 105*C
DELTA TEMP :
2*C
ACM TURBINE OUT : 28*C
CONDENSOR BLEED AIR IN (7.1) : 33*C
CONDENSOR BLEED AIR OUT (7.2 ) : 13*C
DELTA TEMP : 20*C
CONDENSOR COLD AIR OUT (7.3) : 13*C
WATER EXTRACTOR IN : 33*C
TICV OUT :
41*C
PKY
NO REG ATA WO NO

1 PK-WGT 70 969359

2 PK-WGZ 21-31 970416

3 PK-WHM 22 969883

4 PK-WHV
5 PK-WFY 36 970431

DMI OPEN
NO REG ATA
DATE/CAT

20/10/2019
1 PK--WGG 23-11-1
"D"

26/10/2019
2 PK-WJG 74-21-1
"A"
HIG
WO
ALERT NO
ISSUED

23/10/2019

26/10/2019 105275

24/10/2019 105156
26/10/2019

TS TAB
DMI NO
ISSUED

20/10/2019 0032084

27/10/2019 00018418
HIGHLIGHT
DISCREPANCIES

ENG #2 REPORTED HIGH CONSUMP

DURING DESEND CABIN RATE LATE


TO DESEND CABIN RATE UP & DOWN
TO LATE CATCH UP THE TARGET
CABIN ALT

A/P DISCONNECTED INFLIGHT


SEVERAL TIMES

MASTER CAUTION LIGHT F/O SIDE


CAN'T BE RESTTED
BLEED LEAK ENG #1 SOMETIMES
APPEAR

DMI INV
DISCREPANCIES

HF CANNOT TRANSMIT

START ENG #1 WITH "A" NO ITT


GHLIGHT ATR 72-50
RECOMMENDATION

INSPECT BREATHER
TUBE,EXHAUST AND EXTERNAL
AREA

REPLACE DIGITAL CONTROLLER


AND FUT TEST ON GROUND
CABIN PRESSURE CONTROL IN
AUTO MODE

REPLACE SERVO 19 CA

REPLACE MASTER CAUTION


PUSH BUTTON SWITCH.
PN : 720-9200-21
REPLACE UNDER FLOOR DUCT
SEAL

DMI INVESTIGATE
RECOMMENDATION

OPT TEST OF HF SYSTEM,CHK


MSG AND RPLC HF TX

RPLC RLY 153JH,RPLC IGN


PLUG,RPLC IGN EXCITER,RPLC
IGN LEAD CABLE

REMARK
CONTINUE TS / INPROGRESS
AOG
HM BTH
CLOSED/REOPEN
R 72-500/600
MAINTENANCE ACTION STATUS

SPARE O-RING AS3209-138


OPEN
O-RING AS3209-325 NOT AVAIL AT TKG

OPEN DMI NO 004342 NEED SPARE DIGITAL


CONTROLLER FOR TS
RQ #422185 FROM K110 CLOSED
MP RII REQ FROM UPG
ADC TESTER FROM KOE

AFTER MONITOR TODAY PROBLEM STILL


EXIST,CHECK MSG STILL 19CA,PLEASE MONITOR
ARRANGE SPARE SERVO ACTUATOR 19CA

PERFORMED REPLACE FO SIDE MASTER


CAUTION PUSG BUTTON,OPT TEST RESULT CLOSED
GOOD
PEMRFORMED REPLACE APAIRS SEAL ON
UNDER FLOOR,LEAK CHECK FOUND OK AND CLOSED
AIRCARFT SERVICEABLE

IGATE
MAINTENANCE ACTION STATUS

SPARE HF TXRX NOT AVAIL AT BPN


OPEN
P'SE ARRANGE SPARE TO A/C RON

PERFORMED REPLACE IGNITER PLUG ENG 1


CLOSED
A,ENG START 1 A RESULT GOOD
WO
REMARK
CLOSED

1. CAN'T PERFORM D/T HEAVY RAIN AT


PKU.
INFO EIC TODAY ENG #2 OIL ADDED 2
QRTS FOR 11 HOURS

NEED SPARE DIGITAL CONTROLLER,


27/10/2019 PLEASE ARANGE SPARE TO A/C RON
STATION

INFO EIC A/P INFLIGHT FOUND GOOD.


GROUND OPT TEST FOUND GOOD.
PLEASE ARRANGE SPARE SERVO 19CA

27/10/2019
WAITING SPARE UNDER FLOOR BLEED
27/10/2019 DUCT SEAL,PLAN SPARE SEND VIA
JT775

REMARK

1. PROBLEM SOMETIMES STILL EXIST.


GROUND OPT TEST PASS.
PLEASE ARRANGE SPARE HF
TRANSCEIVER 1RE2.
PN : 822-0101-002
TO A/C STA RON

27/10/2019
STA RON

TKG

UPG

BDO

AMQ
DPS

STA RON

BPN

LAH

Вам также может понравиться