TTM-i4N SERIES USER'S MANUAL OUTER DIMENSION WIRING

48 4 59
Thank you for purchasing model TTM-i4N SERIES Digital Temperature Controller. ※OUT2 / EV2 is not available when Option-B is not specified.
Please go through this Instruction Manual carefully and use the unit in proper manner. ( 2)
If the unit is used in a manner not specified by the manufacturer,the protection provided the unit may be impaired. OUT2/EV2
WARNING
NOTICE/WARNING BEFORE OPERATION USE NO ① ⑥C ※Terminal ⑥
Relay Output AC250V 1A (Load resistance) Exactly same potential wires for EV1 and EV2
The meaning of the symbols indicated on the label found at the side of the unit is as follows. circuits can be connected.
: Cautions,Danger,Refer to a manual : Alternating current

48
OUT1 ① ⑥ EV1
: Cautions,Danger of Electric Shock : Reinforced/dual insulation
NO ② ③C ② ⑦ NO ⑦ ⑥C
When having the purchased controller at hand,please be sure that its correct model. Relay Output AC250V 3A (Load resistance)
③ Relay Output AC250V 1A (Load resistance)
See the following “Model Configuration” . ⑧
② + - ③ ④
The following symbol marks provide to prevent incident or damage.Kindly refer to the details Watertight packing ⑨
※This packing is not attached
SSR Driving Voltage Output DC12V
of the WARNING/CAUTION when using for the first time. ⑤ ⑩ Temp. INPUT
※Clean the unit by well squeezed cloth with water. when Option-B is not specified.

WARNING POWER SUPPLY


⑧b
⑨B
⑧-
⑨+
Due to mishandling,the serious damages may occur to the operator,such as death, PANEL CUTOUT & INSTALLATION 100 to 240V AC 50/60HZ 6VA ④ ⑩A ⑩
electrocution or skin burn. (NO polarity) ⑤ RTD TC
45 +0.6

CAUTION
Owing to mishandling,the operator may be inflicted with slight injury,or may cause some Single Unit Istallation
WARNING

+0.6

damage to the unit.

45
・Use specified size (M3.5 width 7.3 mm or less) crimped terminals for wiring and

60(or more)
CAUTION Multiple Unit Installation machines & tools.
For prevention of its malfanction,do not push the front key with sharp points. ・A conformity wire : copper / AWG18-24 / Temp.rating 80℃
Spare terminal must not be used for other purposes. ・Tightening torqe : 0.5 Nm ( 5 kgfm, 4.43 lb.fin)
・Make sure the wiring is done correctly for any wires with polarity ( + and - ).
WARNING ・For relay contact output, “C : common” and “NO : normal open” .
(48×n−3)
+0.6
Installation Attachment
Make sure the correct wiring connection before turning on electricity. 0

・Temp.INPUT and OUT1 in case of SSR Output,only the secondary circuits


Mis-wiring may cause malfunction of the unit and fire. ・Install the unit in either horizontal or vertical ( upward ) direction. with reinforced/dual insulation from the primary side can be connected.
Never modify the unit to prevent damage or incident such as malfunction and fire etc. ・When fitting the product,give more than 12 mm space between the upper / lower / left & right
・Please put this user's manual aside for your reference,when operating the unit. & backface portion to the product and the peripheral device or plates.
・Copy or reprint of this manual,wholly or partially,is not allowed.
・The contents of this manual may change without notice in future. CAUTION CAUTION
・When you use compressed lead wire to install multiple units,please be careful sufficiently ・Do not touch the terminal part while the power is on.
INSTALLATION CONDITIONS not to touch the other lead wires.
・Indoor use ・Altitude up to 2000m ・Pollution Degree 2
PARTS INDICATION ・This Controller is not equipped with overcurrent protection device ( Fuse ).
ACCESSORY & CONFIGURATION Please prepare semi-time lag fuse ( rated voltage : 250V, rated current : 1A )
M KEY For change of display when making power source wiring. A Fuse is connected to the live side.
1) Please be sure that the unit enclosed in packing carton is a right model before using.
F KEY For action of function setting
2) Kindly check the following accessory being contained in that carton box.
・Installation Attachment ( For installation,please see “PANEL CUTOUT & INSTALLATION” on the right.) ▲▼KEY Up down key for change of setting value. ・The use of Noise Filter close to the Power Supply terminal is recommended.
・This user's manual : 1 copy Holding the U/D keys changes value at a rapid rate. Recommended Noise Filter:RSEL-2002W/A(available from TDK Lambda)
3) Model Configuration PV Measured value indication,Charactor indication Noise filter's terminal 3 and 4 should be connected to the unit.
OUT1 Option SV Set value indication,Operation quantity indication Noise filter's body may or may not to be connected to frame ground. Both are acceptable.
TTM-i4N- -A OUT Output monitor(appears when OUT1 is ON)
Code Option
AL1 Alarm1 monitor(appears when EV1 is ON)
B OUT2/EV2 Relay Contact Output
AL2 Alarm2 monitor(appears when EV2 is ON)
Code OUT1
R Relay Contact Output
It also lights when OUT2 is ON in Heating/Cooling Control mode.
CAUTION BEFORE CONTROL
P SSR Driving Voltage Output RDY RDY lamp(It appears in Ready condition)
℃ It lights-up when the set value in the Temp. data is Celsius. ・Setting program is stored after power OFF,as non-volatile memory is equipped with
・This product is intended for use with industrial machineries,machine tools and measurement TTM-i4N SERIES controllers for setting storage.
℉ It lights-up when the set value in the Temp. data is Fahrenheit.
instruments.(It is not to be used with medical equipment which involves human lives). ・Either thermocouple or R.T.D ( Pt100 / JPt100 ) is selectable input type.
For suitable apprication,please select most appropriate input type and adjust input setup.
SPECIFICATIONS ・PID or ON/OFF control is selective for the optimal performance and each detail of features is
specified in the table as bellow.
Input Power Requirments AC100 to 240V, 50/60Hz Event1 Relay Contact Output AC250V 1A MAX
Operating Voltage Range 85% to 110% of the rated voltage OUT2 / EV2 ( Option ) Relay Contact Output AC250V 1A MAX
PID Control
Power Consumption 6VA MAX Operation Environment 0 to 50℃, 20 to 90%RH ( Avoid making of dew ) Merit Better control result is achieved as opposed to that of ON/OFF control.
Memory Element EEPROM Storage Environment -25 to 75℃, 5 to 95%RH ( Avoid making of dew ) Demerit Life span of relay is shorter,as output exists freduently with relay contact.
Input of Sensor a) Thermocouple Input ( type:K,J,R,T,N,S,B ) Weight Less than 100 gms.
b) 3-wire Resistance Temperature Detector Input ( type:Pt100,JPt100 ) Installation Environment Overvoltage Category Ⅱ
(Changeable by input type selection) ON/OFF Control
Location of the Unit Setting Keep away from the following: Merit Life span of relay is generally longer,as it is ON when temperature is below SV
Control Method 3 kinds of PID,ON/OFF ・Gas of corrosion,dust and oily smoke.
・The electrical noise of the generator.
and it is OFF when temperature is over SV ( For heating control ).
OUT1 (Control Output ) a) Relay Contact Output AC250V 3A MAX
b) SSR Driving Voltage Output DC12V 600Ω( or more )
CAUTION ・The influence of electromagnetic field.
・Mechanical vibration and shock.
Demerit Control value is worse in comparison with that of PID control.
( Output type depends on the model. ) ・The direct sunlight.
OPERATION FLOW AND SETTING MENU
●POWER ON ●Setting mode
<SET0 : Priority screen setting mode> <SET1 : Input setting mode> <SET2 : Key function setting mode> <SET3 : Control setting mode> <SET4 : EV1 setting mode> <SET5 : EV2 setting mode>*12*13 <SET6 : Timer setting mode> <SET7 : LCD setting mode>
“Input type setting screen” appears for 4seconds, 1. Setting item selection screen 1. Setting item selection screen 1. Setting item selection screen 1.Setting item selection screen 1.Setting item selection screen 1.Setting item selection screen 1.Setting item selection screen 1. Setting item selection screen
▲KEY ▲KEY ▲KEY ▲KEY ▲KEY ▲KEY ▲KEY
then it will oriceed to “Run mode” . SET0 Setting for priority screen SET1 Setting related to input SET2 Setting related to Setting related to control
SET3 SET4 EV1 output function setting SET5 EV2 output function setting SET6 Setting concerned with SET7 Setting related to LCD
PR1 (Refer to Ex.1.) ▼KEY INP ▼KEY KEY key functions ▼KEY CNT ▼KEY AL1 ▼KEY AL2 ▼KEY TIME timer parameters ▼KEY LCD
M key M key M key M key M key M key M key M key
M key 2. Priority screen 1 setting 2. Input type setting 2. Function key function setting 2. SV limiter upper limit 2. EV1 setting mode 2. EV2 setting mode *12 2. Timer output setting 2. Brightness setting
●RUN mode Press for
PRI1 Select 1st screen on INP Select input type FU SLH‘ Setting range : Low to high limit A1F1 EV1 alarm function 1 setting A2F1 EV2 alarm function 1 setting TMO LLV Setting range : 5 ~ 100
A. Primary screen 2 seconds OFF Run mode B 00 00++ 1200  ※Keep the difference of more than 5 degrees(℃ or ℉) 000++ 000++ 0 Setting unit : %
100
between Low and high limit of the SV limiter.
Measured value Set the temperature M key 00 K Thermocouple ① Function setting ①Function 0 Non-use timer function M key
Set value required Setting unit : ℃ or ℉ ①Function

3. Priority screen 2 setting 01 J " 0 : None ③ 0 : None 0 : None ‘1 Control 3. Dimming function setting
M key ② 1 : Digit shift M key ② 1 : Deviation upper and lower limits ② 1 : Deviation upper and lower limits ‘2 EV1 output
PRI2 Select 2nd screen on 02 R " ① ① ① LRFT Setting range : 0 ~ 9999
B. Priority screens (1 ~ 9)  OFF Run mode B 03 T 2 : RUN/READY 3. SV limiter lower limit 2 : Deviation upper limit 2 : Deviation upper limit ‘3 EV2 output 0 Setting unit : seconds
"
M key 04 N
3 : AT start/stop
SLL‘ Setting range : Low to high limit 3 : Deviation lower limit 3 : Deviation lower limit
※“3” is not selectable when Option-B is not specified.  ※No dimming function when set to “0” .
Priority displays by setting " 4 : Timer start/stop 4 : Deviation range 4 : Deviation range
05 S 0  ※Keep the difference of more than 5 degrees(℃ or ℉) M key
and shows max.9 screens by setting. 4. Priority screen 3 setting " 5 : Alarm reset between Low and high limit of the SV limiter. 5 : Absolute value upper and lower limits 5 : Absolute value upper and lower limits M key
06 4. Dimming Brightness setting
Setting unit : ℃ or ℉
B " 6 : ENTER 6 : Absolute value upper limit 6 : Absolute value upper limit
PRI3 Select 3rd screen on 3. Function setting *18
10 Pt100 7 : Absolute value lower limit 7 : Absolute value lower limit
OFF Run mode B ② Pressing time setting M key TMF LRLV Setting range : 0 ~ 100
M key 11 JPt100 8 : Absolute value range 8 : Absolute value range Setting unit : %
M key 0 : None 1 5
(Press for 4 seconds) M key 1 : Pressing time 1 second
4. Control mode setting ②Add-on function ②Add-on function M key , return to 1
M key 5. Priority screen 4 setting Setting for control mode 1 Auto start ( ON delay )
(Press for 2 seconds) 3. PV compensation gain setting 2 : Pressing time 2 seconds MD 0 : None 0 : None
PRI4 Select 4th screen on 3 : Pressing time 3 seconds RUM 1 : Hold 1 : Hold 2 Manual start ( ON delay )
OFF Run mode B PVG Setting range : 0.50 ~ 2.00 4 : Pressing time 4 seconds 2 : Standby 2 : Standby 3 EV1 start ( ON delay )
●Protect setting mode M key 100 Setting unit : times RUN Control start
3 : Delay ( OFF delay )
5 : Pressing time 5 seconds 3 : Delay 4 Auto start
M key RDY Control stop 4 : Hold+Standby 4 : Hold+Standby
Setting screen 6. Priority screen 5 setting 5 Manual start ( OFF delay )
M key MAN Manual 5 : Hold+Delay 5 : Hold+Delay
PTLV Mode to set the protection level PRI5 Select 5th screen on 4. PV compensation zero setting 6 EV1 start ( OFF delay )
3. Key-lock setting M key 6 : Standby+delay 6 : Standby+delay
( OFF delay )
0 OFF Run mode B PVS‘ Setting range : -199 ~ 999 7 : Hold+standby+delay 7 : Hold+standby+delay
7 SV start
0 -199.9 ~ 999.9 LOC 5. Control type setting 8 EV2 start ( ON delay )
0 Non-Protect M key
Setting unit : ℃ or ℉ 0
CNT ①Function ③Control mode interlocking function ③Control mode interlocking function 9 EV2 start ( OFF delay )
1 ・Setting change for SV/Priority Screen is Possible 7. Priority screen 6 setting 0 Lock OFF ‘020++ 0 : All modes 0 : All modes
M key 0 : TypeA ※“8” and “9” are not selectable
・The Setting Mode Parameter blinds PRI6 Select 6th screen on ‘1 Lock all 1 : RUN/ MANUAL mode only 1 : RUN/ MANUAL mode only
5. PV Filter setting 1 : TypeB when Option-B is not specified.
parameters except for the following: OFF Run mode B 2 : RUN mode only 2 : RUN mode onl
‘2 Lock run mode ① 2 : Fuzzy
PV compasation zero setting M key PDF Setting range : 0.0 ~ 99.9
‘3 Lock except run mode ② M key M key
M key
00 Setting unit : seconds ②Coutrol type of OUT1
Alarm reset 8. Priority screen 7 setting ③ *12*14 4. Unit setting *18
M key
※Protect Level Setting is not subjected to 1 : PID control 3. EV1 alarm upper limit setting *8 *9 3. EV2 alarm upper limit setting
AT start/reset Key-Lock Setting. *15 H/M
Proportional band setting for OUT1/OUT2
PRI7 Select 7th screen on
6. Decimal point setting
2 : ON/OFF control
A1H Setting range : -1999 ~ 3276 or -199.9 ~ 999.9 A2H Setting range : -1999 ~ 3276 or -199.9 ~ 999.9
1
OFF Run mode B M key 0  ※In case of thermocouple R/S/B : -1999 ~ 3276 0  ※In case of thermocouple R/S/B : -1999 ~ 3276
Integral time setting DP 0:Not required ③Control type of OUT2
Setting unit : ℃ or ℉
M key 4. Alarm reset 0 : None Setting unit : ℃ or ℉ 1 Hour / Minute
Deviative time setting 0 0.1:Required 2 Minute / second
9. Priority screen 8 setting 1 : PID control M key M key
Control sensitivity setting for OUT1/OUT2 (Except R/S/B Thermocouple) ALRS 2 : ON/OFF control M key
Upper limit setting for EV1/EV2 PRI8 Select 8th display on 0 0 4. EV1 alarm lower limit setting *8 *10 4. EV2 alarm lower limit setting *12*14
OFF Run mode B M key 3 : EV2 output *16 5. Start SV permissible range setting *18*19
Lower limit setting for EV1/EV2
7. Temperature unit setting
Screen for Alarm reset of EV1/EV2
※When Option B is not specified,Control type of
A1L Setting range : -1999 ~ 3276 or -199.9 ~ 999.9 A2L Setting range : -1999 ~ 3276 or -199.9 ~ 999.9
M key ※Press F key for 1 second to reset the alarm. 0  ※In case of thermocouple R/S/B : -1999 ~ 3276 0  ※In case of thermocouple R/S/B : -1999 ~ 3276 TSV Setting range : 0 ~ 999 or 0.0 ~ 999.9
2 ・Setting change is possible with SV only. C/F ℃: Celsius  (The indication momentarily disappears as OUT2 shall be fixed at “None” . Setting unit : ℃ or ℉ Setting unit : ℃ or ℉ 0 Setting unit : ℃ or ℉
・The priority screen is with indication/ 10. Priority screen 9 setting
*C ℉: Fahrenheit  the Alarm reset is executed). M key M key M key M key
Setting Change not possible. PRI9 Select 9th screen on
M key , return to 1 6. Forward/reverse operation setting
・All setting mode parameters will be blinded. OFF Run mode B 0 0 No alarm occurrence 5. EV1 alarm sensitivity setting *8 5. EV2 alarm sensitivity setting *12*14 6. Time setting *18
3 ・SV is with indication / setting change not possible. M key , return to 1 0 1 Only EV1 is occurring DIR‘ 0 : Reverse operation A1C Setting range : 0 ~ 999 or 0.0 ~ 999.9 A2C Setting range : 0 ~ 999 or 0.0 ~ 999.9 TIM Setting range : 00 : 00 ~ 99 : 59 (Hour/Minute)
・Priority Screen is with indication / setting change 1 0 Only EV2 is occurring 0 1 : Forward operation 0 Setting unit : ℃ or ℉ 0 Setting unit : ℃ or ℉ 00:00 00 : 00 ~ 99 : 59 (Minute/second))
not possible. 1 1 Both EV1/EV2 are occurring M key M key M key M key
・All setting mode parameters will be blinded. 7. Operating amount for OUT1
M key , return to 1 6. EV1 alarm delay timer setting *11 6. EV2 alarm delay timer setting *12*17 7. Remaining time monitor *18
MV1‘ Displays operating amount for OUT1
A1T Setting range : 0 ∼ 9999 A2T Setting range : 0 ∼ 9999 TIA Screen for remaining time monitor
00 and set the amount on manual control. Setting unit : seconds
●EX1. Priority screens & its setting 0 Setting unit : seconds 0 00:00 ※Timer start and stop are alternately
Display amount : 0.0 ~ 100.0(%) switched by F key.
M key M key
This function enables the selection of the most necessary screen indication Setting amount : MLL1 ~ MLH1(%)
from all the screen indication found in the setting mode,and assign it to 7. EV1 alarm function 2 setting 7. EV2 alarm function 2 setting *12 M key , return to 1
M key
the RUN mode on priority basis. A1F2 EV1 alarm function 2 setting A2F2 EV2 alarm function 2 setting
Please select priority screen indication through the priority screen setting mode. <When select PID control> <When select ON/OFF control> 000++ for PV error 000++ for PV error *1 No indication when the type of control OUT1 is ON/OFF Control.
31. Sensitivity setting for OUT2 *4 *6
*2 No indication when the type of control OUT1 is PID Control.
Setting range : 0 ∼ 999 or 0.0 ∼ 999.9
eg:Basic screen →  OUT1 manipulated value → Setting high limit for EV1 *2 ①Function ①Function
8. Tuning type setting *1 19. Sensitivity setting for OUT1 C2 ③ ③
*Screen is shifted when pressing M key each time. Setting range : 0 ∼ 999 or 0.0 ∼ 999.9 1 Setting unit : ℃ or ℉ 0 : None 0 : None *3 No indication when the OUT1 loop error determination time is “0” .
TUN C1 ② 1 : PV error ② 1 : PV error
1 1 Setting unit : ℃ or ℉ M key ① ① *4 No indication when the type of control OUT2 is either “None” or “EV2” .
②Add-on function ②Add-on function *5 No indication when the type of control OUT2 is ON/OFF Control.
M key 32. OFF point position setting for OUT2 *4 *6
●EX2. Function key works 1 Auto-tuning : OUT1
*2
0 : None 0 : None *6 No indication when the type of control OUT2 is PID Control.
2 Self -tuning : OUT1 20. OFF point position setting for OUT1 CP2 Setting range : -199 ~ 999 or -199.9 ~ 999.9 1 : Hold 1 : Hold
This function is to enable F key to use as a specific key,for the following actions Auto-tuning 0 Setting unit : ℃ or ℉ *7 No indication when the OUT2 loop error determination time is “0” .
3 : OUT2 CP1 Setting range : -199 ~ 999 or -199.9 ~ 999.9 2 : Delay 2 : Delay
selected in F key setting belonging to setting mode. Self -tuning Setting unit : ℃ or ℉ 3 : Hold+Delay *8 No indication when the EV1 Function is set at “No Function” .
4 : OUT2 0 M key 3 : Hold+Delay
Function 5 Auto-tuning : OUT1/OUT2 M key 33.Loop anormaly time setting for OUT2 *4 ③Control mode interlocking function ③Control mode interlocking function *9 No indication when the EV1 Function is not used in the Upper Limit Alarm.
M key 21. Loop anormaly time setting for OUT1 LOP2 Setting range : 0 ~ 9999 0 : All modes 0 : All modes *10 No indication when the EV1 Function is not used in the Lower Limit Alarm.
1. Digit shift Setting unit : seconds 1 : RUN/ MANUAL mode only
0 1 : RUN/ MANUAL mode only *11 No indication when the EV1 & 2 Functions to “No Function” .
Setting digit shift is enabled when setting value is changed. Effective 9. AT coefficient setting *1 LOP1 Setting range : 0 ~ 9999
 ※At “0” setting,there is no loop error determination. 2 : RUN mode only 2 : RUN mode only
Digit under selection will blink. in all modes Setting range : 0.1 ~ 10.0 0 Setting unit : seconds *12 No indication when Option-B is not specified.
ATG  ※At “0” setting,there is no loop error determination. M key
10 Setting unit : times M key M key *13 No indication when the type of Control OUT2 is set to anything other than “EV2” .
2. RUN/READY
Control stop(READY) and control performance(RUN) are M key M key 34. Loop anormaly PV change threshold for OUT2 *4 *7 8. EV1 alarm function 3 setting 8. EV2 alarm function 3 setting *12 *14 No indication when EV2 Function is set at “No Function” .
alternately switched by F key. 10. AT sensitivity setting 22. Loop anormaly PV change threshold for OUT1 *3 PS2 Setting range : 0 ∼ 999 or 0.0 ∼ 999.9 *15 No indication when the EV2 Function is not used in the Upper Limit Alarm.
*1
Setting unit : ℃ or ℉
A1F3 EV1 alarm function 3 setting A2F3 EV2 alarm function 3 setting
Setting range : 0 ∼ 999 or 0.0 ∼ 999.9 PS1 Setting range : 0 ∼ 999 or 0.0 ∼ 999.9 0 00++ for loop anormaly 00++ for loop anormaly *16 No indication when the EV2 Function is not used in the Lower Limit Alarm.
3. AT Start / Reset ATC Setting unit : ℃ or ℉  ※At “0” setting,there is no loop error
AT(Auto -Tuning) starts instantly after pressing F key. Effective only 2 Setting unit : ℃ or ℉ 0 PV change determination. ①Function ①Function *17 No indication when the EV 1 & 2 Functions to “No Function” .
 ※At “0” setting,there is no loop error
Start and Reset are alternately switched by F key. in Operating mode M key PV change determination. M key 0 : None 0 : None *18 No indication when the Timer Output is set to “Timer Not Used” .
② 1 : Loop error ② 1 : Loop error
4. Timer Start / Reset  11. AT start/stop *1 M key 35. Loop anormaly PV threshold for OUT2 *4 *7 ① ① *19 No indication when the Timer Function is set to other than “SV Start” .
Start and Reset are alternately switched by F key. AT 23. Loop anormaly PV threshold for OUT1 *3 TS2 Setting range : 0 ∼ 999 or 0.0 ∼ 999.9 ②Add-on function ②Add-on function
OFF Setting range : 0 ∼ 999 or 0.0 ∼ 999.9 0 Setting unit : ℃ or ℉ 0 : None 0 : None
5. Alarm Reset TS1 Other Display Indication
Press once for function. OFF AT stop 0 Setting unit : ℃ or ℉  ※At “0” setting,there is no loop error 1 : Hold 1 : Hold
PV threshold determination.
ON AT start  ※At “0” setting,there is no loop error M key M key ~~~~ Displays whenever input value exceeds the high limit of display range.
6. Enter  Effective PV threshold determination. M key
※AT start and ATstop are alternately switched Also displays when the wire is snapped off thermocouple and that of R.T.D.
Press once for function. in all modes by F key. M key 36. Protection OFF timer time setting for OUT2 *6 *4 9. EV1 alarm polarity setting 9. EV2 alarm polarity setting *12
M key 24. Protection OFF timer time setting for OUT1 FDT2 Setting range : 0 ~ 99 A1P A2P ____ Displays whenever input value exceeds the low limit of display range.
*2 0 0
12. Proportional band setting for OUT1 *1 0 Setting unit : Minuites
●EX3. To select PID FDT1 Setting range : 0 ~ 99
0 Normal open 0 Normal open ERR0cvDisplays at memory error.
P1 Setting range : 0.1 ~ 200.0 0 Setting unit : Minuites M key
Setting unit : % per SLL ∼ SLH 1 Normal close 1 Normal close
Features of type A,B,FUZZY 30 M key 37. Protection ON timer time setting for OUT2 *6 *4
M key , return to 1 M key , return to 1 ERR1cvDisplays at input circuit error.
TypeA Basic PID M key 25. Protection ON timer time setting for OUT1 *2 NDT2 Setting range : 0 ~ 99
13. Integral time setting *1 0 Setting unit : Minuites
TypeB Over shoot protection PID NDT1 Setting range : 0 ~ 99
I Setting range : 0 ~ 3600 0 Setting unit : Minuites M key ERR2cvDisplays when auto-tuning does not end after 3 hrs.,
FUZZY Effectively control the over shoot in the beginning of PID control. Shift to Blind setting mode or when error occurs during the auto-tuning.
0 Setting unit : seconds M key 38. Balance less / Bump less
If control is unstable under self-tuning, M key 26. Operating amount for OUT2 BMP ●POWER ON
*4 Displays when the parameter change is attempted during key lock mode.
please change to type A ,B or FUZZY and also ON/OFF control. 1
14. Deviative time setting *1 MV2‘ Displays operating amount for OUT2 LOC
and set the amount on manual control. 0 No Balance less / Bump less function “Input type setting screen” appears for 4 seconds,
D Setting range : 0 ~ 3600 00
then it will procceed to “Run mode” . Displays during auto-tuning.
●EX4. ARW (Anti-Reset-Windup) 0 Setting unit : seconds Display amount : 0.0 ~ 100.0(%) 1 With Balance less / Bump less function AT
M key Setting amount : MLL2 ~ MLH2(%) M key ●RUN mode
ARW take effect for overshooting by over-integral of PID action. Displays when the control mode change is attempted
15. Proportional cycle setting for OUT1 *1 M key <When select ON/OFF control> 39. Manual reset setting *1 M key (Press for 10 seconds) FUNC during which function keys are allocated to RUN/READY.
・ARW controls integral action (PV accords with SV). Setting range : 1 ∼ 120
T1 <When select PID control> PBB Setting range : 0.0 ~ 100.0% Indication disappears momentarily
・If integral value goes down,it takes effects. 20 Setting unit : seconds 00  -100.0 ~ 100.0% (Heat / Cool) Displays when the control mode change is attempted
27. Proportional band setting for OUT2 *4 *5 F key (Press for once) TIME during which the timer is in use..
If integral value is set “0” ,it stops integral action. M key M key
P2 Setting range : 0.10~10.00 M key (Press for once)
16. ARW setting (see Ex.4) *1 40. Dead band setting *4
100 Setting unit : Magnification to MV1 Blind setting mode
Table1. To select input sensors and setting range. unit : ℃ ARW Setting range : 0.0 ~ 110.0
M key DB Setting range : -100 ~ 100
Please select parameters to be blinded **** **** : Selected parameter is indicated.
1100 Setting unit : % 0 -100.0 ~ 100.0   ON
through the Blind setting mode.
M key 28. Proportional cycle setting for OUT2 *4 *5 Setting unit : ℃ or ℉
Symbol Low limit ~ High limit 0.0 Setting ON Value is indicated.
17. Operating amout limiter upper limit for OUT1 *1 T2 Setting range : 1 ∼ 120 M key ●RUN mode
K Thermocouple -200 ~ 1372 -199.9 ~  999.9 20 Setting unit : seconds OFF No indication
MLH1 Setting range : MLL1 ~ 100.0 41. Ramp time setting ※ ON/OFF is changed by F key.
J -200 ~  850 -199.9 ~  850.0 M key M key (Press for 2 seconds)
Setting range : 0.0 ∼ 999.9
TOHO ELECTRONICS INC.
" Setting unit : %
1000 RMP
R " 0 ~ 1700 -
M key 29. Operating amout limiter upper limit for OUT2 *4 *5 00 Setting unit : ℃/min. or ℉/min. SET0 ▲ SET1 ▲ SET2 ▲ SET3 ▲ SET4 ▲ SET5 ▲ SET6 ▲ SET7 ▲ to SET0
T " -200 ~  400 -199.9 ~  400.0 MLH2 Setting range : MLL2 ~ 100.0 ※Ramp function OFF at 0.0 ON ▼ ON ▼ ON ▼ ON\ ▼ ON ▼ ON ▼ ON ▼ ON ▼
18. Operating amout limiter lower limit for OUT1 *1
N " -200 ~ 1300 -199.9 ~  999.9 1000 Setting unit : % M key M key M key M key M key M key M key M key M key Head office: 2-4-3 NISHIHASHIMOTO MIDORI-KU SAGAMIHARA KANAGAWA
MLL1 Setting range : 0.0 ~ MLH1
M key 42. Control back up function setting 252-0131 JAPAN
S "    0 ~ 1700 - 00 Setting unit : % PRI1 INP FU SLH A1F1 A2F1 TMO LLV
B " 0 ~ 1800 - M key (Go to 21) 30. Operating amout limiter lower limit for OUT2 *4 *5 PWZ Setting range : 0.0 ~ 10.0 ON ON ON ON\ ON ON ON ON Phone: +81-50-3535-9960 Fax: +81-42-700-2118
Pt100 -200 ~  500 -199.9 ~  500.0 MLL2 Setting range : 0.0 ~ MLH2 00 Setting unit : ℃ or ℉
00 Setting unit : % ※Control back up function OFF at 0.0 Reset the power for Blind setting mode OFF. E-Mail: overseas@toho-inc.co.jp
JPt100 -200 ~  500 -199.9 ~  500.0
M key (Go to 33) M key , return to 1 URL: http://www.toho-inc.com