Project Name : 1000 LITRE RO (PJT ver. 1.0)
Projected By ER. SAMBIT DE (project2@heecpl.com) / HI-TECH ENVIRO ENGINEERS AND CONSULTANT PVT.LTD
File Name: Printed on 13-11-2019
Tag 1 2 3 4 5 6 7 8 9
Flow(m3/hr) 2.0 2.0 2.0 0.5 1.5 0.5 1.0 1.0 1.0
Press(Bar) 0.0 0.0 8.6 0.0 8.2 0.0 7.7 0.0 0.0
TDS(mg/l) 1,000.0 1,000.0 1,000.0 9.6 1,361.3 16.0 1,987.5 12.6 12.6
System Configuration
<Pass 1>
Designated Product Flow 1.00 m3/hr No. of Pressure Vessel 2
Membrane Type and Model RE4040-BLR No. of Element 4
Array Configuration 2 Array, 1-1 , 2 elements/pressure vessel
Recover Ratio 50 % Average Permeate Flux 31.66 lmh
Project Note
NO GUARANTEE of system performance is expressed or implied.Any final design should be reviewed PAGE: 1 OF 3
by an appropriate application engineer.These calculations are based on a feed water of acceptable quality.
Toray Chemical Korea Inc.
http://www.csmfilter.com
CSMPRO v5.02
Project Name : 1000 LITRE RO (PJT ver. 1.0)
Projected By ER. SAMBIT DE (project2@heecpl.com) / HI-TECH ENVIRO ENGINEERS AND CONSULTANT PVT.LTD
File Name: Printed on 13-11-2019
<Pass 1>
Feed flow into RO system 2.00 m3/hr Membrane Age 2.00 year(s)
Permeate Flow 1.00 m3/hr Flux decline rate 7.00 %/year
Pass Recovery 50.00 % Salt passage increase 10.00 %/year
Feed TDS 1000 mg/L Average permeate flux 31.66 lmh
Permeate TDS 12.55 mg/L Feed Osmotic Pressure 0.83 Bar
Concentrate TDS 1,987.5 mg/L Concentrate Osmotic Pressure 1.64 Bar
Salt rejection 98.75 % Chfem. dose 0.00 mg/L
Feed Pressure 8.58 Bar Permeate Blending 0.00 m3/hr
Temperature 25.00 C Softener No
Feed water type Well Water SDI<3
Array Recycle No
Array 1 2
Element Model RE4040-BLR RE4040-BLR
No. of Pressure Vessel 1 1
Elements per PV 2 2
Boost pump pressure (Bar) 0.00 0.00
Permeate back pressure (Bar) 0.00 0.00
NO GUARANTEE of system performance is expressed or implied.Any final design should be reviewed PAGE: 2 OF 3
by an appropriate application engineer.These calculations are based on a feed water of acceptable quality.
Toray Chemical Korea Inc.
http://www.csmfilter.com
CSMPRO v5.02
Project Name : 1000 LITRE RO (PJT ver. 1.0)
Projected By ER. SAMBIT DE (project2@heecpl.com) / HI-TECH ENVIRO ENGINEERS AND CONSULTANT PVT.LTD
File Name: Printed on 13-11-2019
COST ANALYSIS :
No recommendation.
NO GUARANTEE of system performance is expressed or implied.Any final design should be reviewed PAGE: 3 OF 3
by an appropriate application engineer.These calculations are based on a feed water of acceptable quality.
Toray Chemical Korea Inc.