Академический Документы
Профессиональный Документы
Культура Документы
17BCRY49-A S12XNG
Agenda
1 S12X NG characteristics
2 S12X NG Qualification list
3 Difference between old and new products
2 / 43
1 S12X NG characteristic
1.1 Main presentation
Summary
• S128 :
• 4 TCK acquisition board,
• 1 Relay I/O board,
• 1 Communication board (RS485 or Ethernet).
• S129 :
• 4 TCK or Pt100 or 4/20 mA acquisition board,
• 1 Relay I/O board,
• 1 Communication board (RS485 or Ethernet)..
• Setup by front
4 / 43
14ASN001-MTW_R&D 1/7
1.2 Main presentation
Front view
5 / 43
1.3 Main Characteristic
S128/S129
6 / 43
1.4 Main Characteristic
S128/S129
• Measurement accuracy:
• 1% of the measuring range across the entire ambient
operating temperature range
• Measurement range:
• Thermocouple "K" : 0 à 1000°C
• Probe PT100 : -50°C à +200°C
• operating ambient temperature:
• 5 à 55°C
7 / 43
1.5 TCK acquisition card
TCK 1/2
9 / 43
1.7 PT100 acquisition card
10 / 43
1.8 Power supply Card
11 / 43
1.9 Relay Input / Output Card
12 / 43
1.10 4/20 mA Input card
13 / 43
1.11 Communication card
RS485
14 / 43
1.12 Communication card
Ethernet
15 / 43
1.13 Main function
S129
16 / 43
1.14 Main function
S129
17 / 43
1.15 Main function
S129
18 / 43
1.16 Over view
19 / 43
1.17 Internal Wiring
S129
20 / 43
2 S12X NG Qualification
2 Qualification List
Réf: NAC425-0000000071
6.1 Initial and Reference Tests
6.1.1 Visual and mechanical inspection
6.1.2 Controls of degrees of protection provided by envelopes
6.1.3 50 Hz dielectric strength ("td")
6.1.4 Isolation resistance ("Ri")
6.1.5 Measurement of consumption
6.1.6 Overload and short-circuit resistance (NF EN 61131-2 standard)
6.2 Functional Tests
6.3 Measurement of Reduced Functional Characteristics ("vr")
6.4 Operational Validation Tests
6.5 Assessment of Non-Aggression: Electromagnetic Disturbances Emitted
6.6 Tests for Functional Limits
6.6.1 Influence of the ambient temperature (NF EN 61131-2)
6.6.2 Influence of moisture (NF EN 61131-2)
6.6.3 Influence of the supply voltage (NF EN 61131-2)
6.6.4 Influence of a brief cut (NF EN 61131-2)
6.6.5 Influence of electromagnetic disturbances
22 / 43
2 Qualification List
Réf: NAC425-0000000071
23 / 43
3 Difference between Old and new
product
3.1 Monitor : dimensions comparison
► New model dimension are egal or smaller
Previous New
► Drilling cut is the same. (mm)
model model
Depth 124 96
Height 98 98
Panel
186x92 185x89
Cut
25 /43
3.2 Monitor : Front panel comparison
► Same function, differently located
► Same alarms and displays
26 /43
3.3 Monitor : Rear connections comparison
► New connectors: SUB-D Type
27 /43
3.4 Difference between Old and new Product
Fixation
Old New
28 /43
3.5 TC Terminal : dimensions comparison
► New model dimension are egal or smaller
► Mounting way is the same
Length 101 90
Width 77 77
Height 63 63
29 /43
3.6 TC Terminal : wiring comparison
► Same number of input, differently located
► Explicit position of each input written on pcb
30 /43
3.7 PT100 Terminal : dimensions comparison
► New model dimension are egal or smaller
► Mounting way is the same
Length 101 90
Width 77 77
Height 63 63
31 /43
3.8 PT100 Terminal : wiring comparison
► Same number of input, differently located
► Explicit position of each input written on pcb
32 /43
3.9 4-20mA Terminal : dimensions comparison
► New model dimension are egal or smaller
► Mounting way is the same
Length 101 90
Width 77 77
Height 63 63
33 /43
3.10 4-20mA Terminal : wiring
► Same number of input, differently located
► Explicit position of each input written on pcb
34 /43
3.11 Alarm Terminal : dimensions comparison
► New model dimension are egal or smaller
► A metal frame replace the plastic frame, still for DIN mount
Width 77 77
Height 63 63
35 /43
3.12 Alarm Terminal : wiring comparison
► Same number of input/output, differently located
► Explicit position of each input/output written on pcb
37 /43